• Title/Summary/Keyword: Pulse wave

Search Result 1,037, Processing Time 0.027 seconds

Determination of Plane-wave Reflection Coefficient in Underwater Acoustic Pulse Tube Using Two-dimensional Fourier Filtering (이차원 푸리에 필터링을 이용한 수중음향 펄스 튜브에서의 평면파 반사계수 결정)

  • Kim, Wan-Gu;Kang, Hwi Suk;Yoon, Suk Wang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.6
    • /
    • pp.493-498
    • /
    • 2015
  • Complex acoustic signals can be formed in a water-filled acoustic pulse tube under some exciting conditions. It makes difficult to measure plane-wave reflection coefficient with the pulse tube for low frequency bands. In this study, using COMSOL Multiphysics we show that the tube wall excitation generates complex acoustic field of nonplanar mode as well as planar one. From such field incident or reflected planar mode can be decomposed respectively with a modal decomposition method, two-dimensional Fourier filtering. It makes possible to more accurately determine the plane-wave reflection coefficient of acoustic specimen with time gating.

Change of Heart Rate Variability on Menstruation in Women at College (여대생 월경(月經)의 심박변이도 변화에 대한 연구)

  • Kim, Gyeong Cheol;Kim, Yi Soon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.26 no.5
    • /
    • pp.745-752
    • /
    • 2012
  • This study aims to show the change of Heart Rate Variability(HRV) and Pulse wave velocity(PWV) on menstruation in women at college. Heart Rate Variability(HRV) and Pulse wave velocity(PWV) of 122 women at college were measured at their menstruation and ordinary period. SDNN, RMSSD, SDSD, HRV Index(%), stress resistance and cardiac activity were significantly higher at their menstruation than ordinary period, but Total Power and pNN50(%) were opposite. The automatic nervous system balance and physical stress were decreased in groups without dysmenorrhea than with one. PWV(E-R) and PWV(E-L) were much higher at menstruation than ordinary period. PTT(F-R) and PTT(F-L) were decreased in groups without dysmenorrhea than with severe one. We demonstrated that menstruation can effect on Heart Rate Variability and Pulse wave velocity and dysmenorrhea can cause the imbalance of autonomic nervous system.

Peak Detection of Pulse Wave Based on Fuzzy Inference and Multi Sub-Band Filters for U-Healthcare (U-헬스케어를 위한 퍼지추론과 다중 하위대역 필터를 기반한 맥파 최대치 검출)

  • Lee, Ju-Won;Lee, Byeong-Ro
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.12
    • /
    • pp.2159-2164
    • /
    • 2008
  • Ubiquitous healthcare system is system that monitors and manages user's health information, and most important in the healthcare system is accuracy of the measured health data. But, the accuracy changes remarkably according to user's motion artifacts in real life. To elevate accuracy of health data, we proposed new algorithm to detect maximum point of pulse wave for heart rate extraction. and the proposed algorithm is to detect maximum points detect of pulse wave in photo-plethysmography signal included motion artifacts by fuzzy inference and multi sub-band filters. In results of experiment to evaluate the performance of the proposed algorithm, we could verify the proposed algorithm extracted maximum point of pulse wave in complex motion artifacts.

Simulation of Pattern Formation and Solitions in Three-Wave Interactions (세 파동의 상호작용에 의한 패턴 형성 및 솔리톤의 전산모사)

  • Lee Hae Jun;Kim Jin Cheol;Kim Gwang Hun;Kim Jong Uk;Kim Chang Beom;Seok Hui Yong
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.42-43
    • /
    • 2003
  • The nonlinear three-wave interaction is an interesting topic having various applications in nonlinear optics, hydrodynamics, acoustic waves, and plasma physics. The resonant interaction between two laser pulses and a plasma wave plays important roles in plasma heating, laser reflection in the inertial confinement fusion (ICF), plasma wakefield generation, and ultra-intense laser pulse amplification and pulse compression using stimulated Raman backscattering (RBS). (omitted)

  • PDF

Development of Airborne High Density High Voltage Power Supply for Traveling Wave Tubes

  • Park Young-Ju
    • Journal of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.257-263
    • /
    • 2005
  • This paper describes the development and testing results of a high density High Voltage Power Supply (HVPS) that drives microwave Traveling Wave Tubes (TWTs) of phased array transmitters for airborne EW systems. The HVPS is designed to consist of a number of modules connected in series. Among them, especially, the high-density pulse transformer module including the resonant circuit is newly designed to make the HVPS much more reliable. In addition, this paper describes the development of high voltage solid-state modulation using fast switching devices (FETs) and also represents the test results of a modulator module.

Characteristic of the pulse wave in hypertension using pulse analyzer with array piezoresistive sensor (어레이 압저항 센서 장착 맥진기의 고혈압 맥파 특성)

  • Choi, Yong-Seok;Kim, Kyung-Yo;Hwang, Seung-Yeon;Kim, Jong-Yeol;Lee, Si-Woo;Kim, Hyun-Hee;Joo, Jong-Cheon
    • Korean Journal of Acupuncture
    • /
    • v.24 no.3
    • /
    • pp.105-116
    • /
    • 2007
  • Objectives : This study was performed to determine whether a pulse analyzer using array piezoresistive sensor was useful to characterize the variables of pulse wave of hypertentive patients (HT) , compared with those of healthy subjects. Methods : One hundred twenty two subjects participated in this study. Sixty nine subjects had hypertension and fifty three subjects had no specific history or disease associated with hypertension. We used automatic pulse analyzer with array piezoreslstive sensor. Results : Calibrated in Chon, no specific differences was between HT group and the healthy group. Calibrated in Gwan. sum of pulse pressure (SPP) of HT group was higher than that of the healthy group. Calibrated in Cheek, mean of height of main peak (Mm) and height of main peak (h1) of HT group were higher than those of the healthy group. Conclusions : Pulse analyzer was useful to determine the risk degree or development possibility of hypertension.

  • PDF

Effect of Heart Rate Variability, Pulse Wave Velocity in Women of Breast Cancer Patients Care by Mountain Cultivated Ginseng Pharmacopuncture (산양삼(山養蔘) 약침(藥鍼)이 유방암절제술 여성의 심박변이도, 맥파전달속도에 미치는 영향)

  • Kim, Gyeong-Cheol;Park, Sang-Wook;Kim, Yi-Soon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.15 no.3
    • /
    • pp.245-260
    • /
    • 2011
  • Objectives: The aim of this experiment is to know the effect of Mountain Cultivated Ginseng Pharmacopuncture on Heart Rate Variability (HRV), Pulse wave velocity (PWV) in Middle Aged Women. Methods: We investigated on 40 women of breast cancer patients. First, we measured their Heart Rate Variability(HRV), Pulse wave velocity (PWV) and then Mountain Cultivated Ginseng Pharmacopuncture $20m{\ell}$ were injected on them. After 30 minutes, we measured Heart Rate Variability(HRV), Pulse wave velocity(PWV) again. As a result, method of non-equivalent control group non-synchronized design were used for evaluation. Results: In HRV, Mean HRV is significantly decreased from 69.15 to 63.34 after injection. Mean RR is significantly increased from 877.20 to 962.10 after injection. SDNN is significantly increased from 32.56 to 41.34 after injection. PNN50 is significantly decreased after injection. RNSSD, SDSD, TP, VLF is significantly increased after injection. Stress Resistance ability is significantly increased from 37.55 to 44.60 after injection. And In PWV, E-R, E-L, H-R, H-L is significantly decreased after injection. Conclusions: Effect of Mountain Cultivated Ginseng Pharmacopuncture on Heart Rate Variability (HRV) increased adaptability of autonomic nervous system and on Pulse wave velocity (PWV) decreased arterial stiffness.

Spectral Analysis of Heart Rate Variability in ECG and Pulse-wave using autoregressive model (AR모델을 이용한 심전도와 맥파의 심박변동 스펙트럼 해석)

  • Kim NagHwan;Lee EunSil;Min HongKi;Lee EungHyuk;Hong SeungHong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.1 no.1
    • /
    • pp.15-22
    • /
    • 2000
  • The analysis of power spectrum based on linear AR model is applied widely to quantize the response of autonomic nerve noninvasively, In this paper, we estimate the power spectrum density for heartrate variability of the electrocadiogram and pulse wave for short term data(less than two minute), The time series of heart rate variability is obtained from the time interval(RRI, PPI) between the feature point of the electrocadiogram and pulse wave for normal person, The generated time series reconstructed into new time series through polynomial interpolation to apply to the AR mode. The power spectrum density for AR model is calculated by Burg algorithm, After applying AR model, the power spectrum density for heart rate variability of the electrocadiogram and the pulse wave is shown smooth spectrum power at the region of low frequence and high frequence, and that the power spectrum density of electrocadiogram and pulse wave has similar form for same subject.

  • PDF

Property of Wireless Clip-type Pulsimeter by Using a Hall Device and a Permanent Magnet (영구자석과 홀소자를 이용한 무선 집게형 맥진기 특성 연구)

  • Yoon, Woo-Sung;Ji, Jong-Ok;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.6
    • /
    • pp.179-185
    • /
    • 2014
  • The existing USB connection type of the clip-type pulsmeter equipped with a Hall sensor and a permanent magnet does not have any error or malfunction to measure the pulse wave. The property of the wireless networking system communicating the pulse wave data through the wireless LAN communication by combination USB with Ethernet and Ethernet to Wi-Fi converting system instead of existing USB connection method was investigated. There are exited that the patient needs to stay at close site of the desktop PC without USB connector and the wireless transfer and receiver networking system has pulse wave measurement SW to receive the pulse wave data. Thus it is expected that the study becomes helpful to measure and transfer the exact pulse wave of the patient in a comfortable pose at close range.

A Study on Arterial Characterization using Finger-Toe Index (FTI) (지첨-족지 지수에 의한 동맥 혈관 특성화 연구)

  • Byeon, M.K.;Han, S.W.;Huh, W.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.777-785
    • /
    • 2007
  • In this paper, Finger-Toe Index (FTI) is proposed as an analytic parameter for the characterization of arterial vessel. Different from the currently being employed pulse wave velocity (PWV) information of the volume pulse wave measured from 4 arterial channels, the proposed FTI uses the ratio of the shorter of the two up-stroke time of PPG from fingers ($UT_{finger}$) and that of PPG (Photoplethysmography) from toes ($UT_{toe}$). To verify the usefulness of the proposed method, Finger-Toe Indexes were derived from the volume pulse waves acquired from 50 people under examination aged from 12 to 81 years old, and they were then compared with blood pressure ankle-brachial index (ABI). It was successfully demonstrated that the arterial stiffness can be estimated with respect to age and FTI is more strongly correlated with the pulse transit time than ABI. From the regression analysis, we also found that FTI has significant correlation PWV for a quantitative index of arterial stiffness and provides more accurate information than ABI for the characterization of arterial vessel.