• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.03 seconds

A Correlation Study of Pattern Identification Instrument and Biomarkers for Polycystic Ovary Syndrome (다낭성난소증후군 변증도구와 생체지표 간의 상관성 연구)

  • Park, Eun-Ji;Baek, Seon-Eun;Kang, Byoung-Kab;Yoo, Jeong-Eun;Jung, In-Chul
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.31 no.3
    • /
    • pp.33-49
    • /
    • 2018
  • Objectives: The purpose of this study was to investigate the correlation between Pattern identification instrument and biomarkers in polycystic ovary syndrome patients. Methods: Pattern identification instrument questionnaire, Sasang constitutional test, body composition test, pulse analyzing test, laboratory test were performed and the results were analyzed. Correlation analysis was performed between pattern identification and laboratory test results. Results: Testosterone, SHBG, $17{\alpha}$-OH-progesterone, AMH were highest in the Kidney-Yang Deficiency (腎陽虛) group. LH, FSH, LH/FSH ratio were the highest in the Endogenous Heat due to Yin Deficiency (陰虛內熱) group. DHEA-S was the highest in the Dampness-Heat in Liver Meridian (肝經濕熱) group. E2, Prolactin, Cholesterol, Triglyceride, HDL-Cholesterol, LDL-Cholesterol, Glucose (FBS), Insulin, HOMA-IR ratio, HbA1c were the highest in the Phlegm-Dampness (痰濕) group. Conclusions: In this study, we obtained basic data analyzing the correlation between pattern identification instrument and biomarkers in polycystic ovary syndrome patients. If further studies are performed, we expect to be able to obtain clues to study the mechanism of polycystic ovary syndrome.

Indirect Detection of Internal Defects in Wooden Rafter with Ultrasound

  • Lee, Sang-Joon;Lee, Sangdae;Pang, Sung-Jun;Kim, Chul-Ki;Kim, Kwang-Mo;Kim, Ki-Bok;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.164-172
    • /
    • 2013
  • The purpose of this research was development of quantitative ultrasonic test methodology for detecting internal defects in members of ancient wooden building. Connection part between wooden members and/or contacted or hidden part by wall of ceiling or other construction materials make it hard to apply direct way of ultrasonic test. So indirect way of ultrasonic test needed to be applied. Test methodology with newly developed prototype of ultrasonic system was proposed. Homogeneous material with polypropylene was also tested for establishing the criterion. Results showed that TOF(time of flight)-energy and pulse length were found out to be proper ultrasonic parameters for predicting depth of defect in wood different from polypropylene. It was not possible to directly apply prediction equation derived from polypropylene. Newly established prediction equation shows coefficient of determination of 0.73 for wood. Finally, defect of replaced rafter members was predicted with the coefficient of determination of 0.32. Various aspects of ultrasound propagation in wood including anisotropy need to be carefully considered to raise up the prediction accuracy.

Effect of Foot Reflexology on Vital Signs, Fatigue and Mood in Cancer Patients receiving Chemotherapy (발마사지가 항암화학요법을 받는 암환자의 활력징후, 피로 및 기분상태에 미치는 효과)

  • Won Jong-Soon;Jeong Ihn-Sook;Kim Ji-Soo;Kim Keum-Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.9 no.1
    • /
    • pp.16-26
    • /
    • 2002
  • Purpose: This study was done to investigate the effect of foot reflexology on vital signs, general fatigue, mood and foot fatigue in cancer patients receiving chemotherapy. Method: Data were collected from a convenience sample of 11 patients who were admitted at S and E University Hospital. Changes in systolic blood pressure (SBP), diastolic blood pressure(DBP), pulse rate(PR), general fatigue, mood status, and foot fatigue between pre and post foot reflexology were analyzed using Wilcoxon signed rank test and Friedman test at 0.05 level of significance. Results: There were significant differences in the SBP(p= .009), DBP(p=.014), PR(p=.015), general fatigue (p=.015) mood status(p=.007), and foot fatigue(p= .007) between pre and post foot reflexology. Conclusion: Foot reflexology can improve vital signs, general/foot fatigue and mood status, therefore we recommend to use foot reflexology as an effective nursing intervention in cancer patients receiving chemotherapy.

  • PDF

A Study on the Estimation of Strength Nondestructive Test of the Admixture Concrete (혼화콘크리트의 비파괴 강도 추정에 관한 연구)

  • Kim, Jeong-Sup;Shin, Yong-Seok;Kim, Pan-Sun;Cho, Cheol-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.4
    • /
    • pp.217-226
    • /
    • 2005
  • This study made member specimen for taking specimen, core with the concrete mixing normal concrete, admixture and conducted the same air curing as field conditions. After performing destructive and nondestructive test by age, estimate expression was suggested by analyzing correlations between compressive strength, rebound number and ultrasonic pulse velocity and the results are as follows. As a result of comparing error rate of existing expressions and this estimation expression, error rate of this estimation is reduced compared to existing expressions and has higher reliability. When conventional concrete expression is applied to admixture concrete, error rate occurs and then this study suggests the estimation expressions depending on types of admixture concrete.

Experimental study on strengthening of R.C beam using glass fibre reinforced composite

  • Mini, K.M.;Alapatt, Rini John;David, Anjana Elizabeth;Radhakrishnan, Aswathy;Cyriac, Minu Maria;Ramakrishnan, R.
    • Structural Engineering and Mechanics
    • /
    • v.50 no.3
    • /
    • pp.275-286
    • /
    • 2014
  • This paper reports the influence of number of layers and length of GFRP sheets wrapped onto RCC beams for strengthening. Twelve beams of size $700mm{\times}150mm{\times}150mm$ were cast and tested. Two beams without GFRP and ten beams wrapped in different lay-up patterns with one and two layers of GFRP sheets was subjected to three point loading test and ultrasonic pulse velocity test. Initial crack load, ultimate failure load and types of failure have been observed and noted. Experimental results indicate a significant increase in initial and ultimate load carrying capacity of GFRP wrapped beams compared to unwrapped beams. The failed control specimen was retrofitted using U wrap scheme and tested under three point loading.

Free-fatty-acid-regulating effects of fermented red ginseng are mediated by hormones and by the autonomic nervous system

  • Lee, Kwang Jo;Ji, Geun Eog
    • Journal of Ginseng Research
    • /
    • v.38 no.2
    • /
    • pp.97-105
    • /
    • 2014
  • Background: Understanding what causes changes in the flux of free fatty acids (FFA) is important to elucidate the etiology of metabolic syndrome. The first aim of this study was to test whether or not hormones and the autonomic nervous system influence blood FFA levels. A secondary aim was to test by means of a multiple group path analysis whether the consumption of fermented red ginseng (FRG; Panax ginseng) would influence those causal relationships. Methods: Ninety-three postmenopausal women (age 50e73 yr) were randomly divided into two groups. One group (44 women; age, $58.4{\pm}5.9yr$; body mass index, $3.6{\pm}2.5kg/m^2$) was supplied place capsules and the other group (49 women, age $58.4{\pm}5.5yr$; body mass index, $22.9{\pm}2.4kg/m^2$) was supplied FRG capsules. Both prior to and after the study (2 wk), blood samples were collected from the participants and several blood variables were measured and analyzed. Results: Squared multiple correlations of FFA were 0.699 in the placebo group and 0.707 in the FRG group. The unstandardized estimate of estradiol (E2) for FFA was 0.824 in both groups. Conclusion: The path coefficients of cortisol and the branchial pulse for FFA were significantly different between the FRG group and the placebo group.

Effects of Hand Massage and Hand Holding on the Anxiety in Patients with Local Infiltration Anesthesia (손마사지와 손잡아주기가 국소마취 수술환자의 불안에 미치는 영향)

  • Oh Hyun-Jung;Park Jeong-Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.34 no.6
    • /
    • pp.924-933
    • /
    • 2004
  • Purpose: This study was to examine the effects of hand massage and hand holding as nursing interventions on the anxiety in patients with local infiltration anesthesia. Method: The design of this study was a nonequivalent, control group, non- synchronized design. The subjects of this study consisted of 15 patients for the hand massage group, 15 patients for the hand holding group and 17 patients for the control group awaiting surgery in the operation room of a general hospitalin Daegu. As an experimental treatment, hand massage was carried out by the Hand Massage Protocol developed by Snyder(1995) and interpreted by Cho(1998) and hand holding developed by Cho(1998). The data were analyzed by SPSS/WIN, T-test, ANOVA, Cronbach's a, and the Scheffe test. Results: The hand massage group and hand holding group were more effective than the control group in reducing anxiety, VAS score, systolic blood pressure and pulse rate. Conclusion: Hand massage and hand holding are effective nursing interventions that alleviates the psychological and physiological anxiety of patients with local infiltration anesthesia. In particular, the simple contact of hand holding is regarded as an effective and easily accessible nursing intervention in the operating room.

A New Directional Coupler Type Partial Discharge Sensor Installed on the Power Lead of Rotating Machine

  • Yi, Sang-Hwa;Hwang, Don-Ha;Park, Wee Sang
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1769-1776
    • /
    • 2016
  • For on-line partial discharge (PD) monitoring of rotating machines, a novel sensor is proposed, which can be installed on the power lead inside the terminal box of the machine. The sensor has been designed to have high capacitance, and minimal reflection of measured pulses. As a sensitivity of the sensor, transfer impedance $Z_t$ has been measured and compared to conventional coupler-type sensors. A simple method is presented for measuring $Z_t$ of coupler sensors, using a vector network analyzer and a practical lead-cable of rotating machine. Through this method, it became possible to measure the $Z_t$ of coupler sensors including the installation environment of them. The $Z_t$ of the proposed sensor is higher than that of same sized other conventional couplers at frequencies between 30 and 92 MHz. Another sensitivity test has been performed using a PD calibrator as a test pulse source. The proposed sensor has higher measured peak voltage than the conventional coupler type sensors when the same charges were input.

Effect of Exercises on the Cerebral Blood Flow (운동이 뇌 혈류 변화에 미치는 영향)

  • Song, Myung-Soo;Choi, Su-Hee
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.1 no.2
    • /
    • pp.1-9
    • /
    • 2003
  • The purpose of this study was to analyze the effect given to the variable details which disturb the flow of blood in brain artery disease through Aerobic exercises. It chose the subjects of study : 5 persons in an exercise group and 5 persons in a non-exercise group. Peak brain blood velocity, mean velocity, and resistance & artery stricture ratio were measured with TCD, measure machine for brain artery blood flow. The conclusion of the study was as follows: 1. At pre-test of an exercises group and a non-exercise group, PBV, MBV, BRI, ASI of a non-exercise group were showed much lower in the variation of left common carotid artery(LCCA). 2. At post-test of an aerobic exercises group and a non-exercise group, PBV, MBV, BRI, ASI of a non-exercise group were showed just a little decrease ratio but were not significant different in the variation of left common carotid artery(LCCA). Viewing on the base of these result, continuing exercises promote the functional improvement of the heart blood system and were showed the positive variation of artery stricture ratio according to brain blood flow velocity, the pulse and resistance or blood velocity. Therefore programs for prescriptions through aerobic exercises must be developed in many ways.

  • PDF

Ultrasonic Characteristics of Internal Planar Defects of a Hot Forged Al-Si Alloy Part (Al-Si 합금 열간단조품 내부의 판상 결함의 초음파 특성)

  • Lee, Seok-Won;Joun, Man-Soo;Lee, Joon-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.6
    • /
    • pp.612-617
    • /
    • 2001
  • A nondestructive evaluation technique for detecting internal defects of an hot forged Al-Si alloy part is established in this study. Ultrasonic characteristics of various internal planar defects are investigated by experiments for establishing a reliable test procedure. The effect of the angle between ultrasonic energy propagation directions and planar defects on the ultrasonic signal configuration is evaluated in the pulse-echo technique. A characteristic of ultrasonic signal for the internal planar defect located near the edge is also evaluated. The applicability of the through-transmission technique is also discussed. Reliability of the presented approach is validated by the destructive testing for more than 500 specimens.

  • PDF