• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.029 seconds

Neonatal isoerythrolysis in Thoroughbred foals

  • Kwon, Do Yeon;Choi, Seong Kyoon;Cho, Young Jae;Cho, Gil Jae
    • Korean Journal of Veterinary Research
    • /
    • v.51 no.1
    • /
    • pp.55-58
    • /
    • 2011
  • Two 4-day-old Thoroughbred foals with acute clinical signs of depression, elevated pulse and respiratory rates, anemia, and jaundice were referred to the equine hospital of Korea Racing Authority. The foals were seemingly normal at birth, but showed clinical signs such as abnormal behavior, jaundice and anemia suddenly after ingestion of the mare's colostrum, followed by death at 4 days after birth. According to the results of the hematology, serum chemistry analysis, jaundice foal agglutination test, and blood groups test, the foals were diagnosed as neonatal isoerythrolysis (NI) caused by the mare's antibodies. These results suggested that the pregnant mares have a potential for NI.

The Thermal Diffusivity of Standard Pieces for Spark Test (불꽃試驗용 標準試片 의 熱擴散 係數)

  • 차경옥;이관수;이흥주
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.7 no.3
    • /
    • pp.319-327
    • /
    • 1983
  • The thermal diffusivity one of the series of standard pieces for spark test are determined by the flash method. The standard pieces are composed with carbon steels, structural carbon steels, alloy steels and high speed tool steels. In order to compute the thermal conductivity of the standard pieces, their specific heats are measured by a differential scanning calorimeter. The thermal conductivities are calculated from the data of specific heat, density and thermal diffusivity. To increase the accuracy of data for the thermal diffusivity by data reduction excursion method in the flash method, the governing heat diffusion equation, which is closely described experimental conditions with the finite pulse and the heat loss from the sample surfaces, is solved. In this analysis an integral transform is used.

Effects of the Vestibular Caloric Stimulation with Ice Water on the Autonomic Nervous System

  • Kim, Chungyoo;Kang, Jongho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.4 no.3
    • /
    • pp.27-30
    • /
    • 2016
  • PURPOSE : The effect of the vestibular caloric stimulation with ice water on the autonomic nervous system was investigated using pulse oximetry. METHOD : Thirty-four healthy men and women were subject to a 2-minute vestibular caloric stimulation with ice water, and autonomic nervous activities (low frequency, high frequency, and total power) were measured before and after the vestibular caloric stimulation. Data were analyzed separately for men and women. RESULT : Low frequency, high frequency, and total power in the men and low frequency in the women were statistically significantly higher after vestibular caloric stimulation. High frequency and total power in the women were higher but not significantly different after vestibular caloric stimulation. CONCLUSION : Vestibular caloric stimulation with ice water increases autonomic nervous activities, with the variation being within the normal range. The test can be considered safe for use.

Hot Firing Performances of 1 lbf-Liquid Monopropellant Rocket Engine under the Environment of High Altitude Simulated (고공모사 환경에서의 1 Ibf급 단일액체추진제 로켓엔진 연소성능시험)

  • 김정수;한조영;이균호;황도순;장기원;이재원;강주성;정종록;조대기
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.189-192
    • /
    • 2003
  • This paper summarizes a satellite program-specific performance requirements and test results for the verification of standard mono-propellant hydrazine thruster (MRE-1) producing 0.95 lbf (4.2 Newtons) nominal steady-state thrust at an inlet pressure of 350 psia (2.41 Mpa). Performance characteristics are shown in terms of thrust behavior at steady state and pulse mode firing. Hot firing test philosophy is briefly introduced, too.

  • PDF

Detection and Location of Partial Discharge in Transformers (변압기내 부분방전 탐지 및 위치검출)

  • 곽희노;김재철;황선주;권태원;윤용범
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.4
    • /
    • pp.53-59
    • /
    • 1992
  • This paper describes an instrument for the detection and geometric location of partial discharge (PD) source in transformers. This instrument measures electric current pulses and ultrasonic pulses simultaneously, counts the number of electrical pulses and determines the geometric location of PD in transformers. It was found that there is a relationship between partial discharge magnitude and pulse repetition rate when the applied test voltage and oil temperature were varied. Through the laboratory test using model transformer, it was clarified that this detector could be used for detecting and locating PD in the transformer.

  • PDF

An Improved Phase-Shifted Carrier PWM for Modular Multilevel Converters with Redundancy Sub-Modules

  • Choi, Jong-Yun;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.473-479
    • /
    • 2016
  • In this paper, the PSC PWM method is chosen as the optimal modulation method for a 20MW VSC HVDC, with consideration of the harmonic distortion of the output voltage, the switching frequency, and the control implementation difficulty. In addition, a new PSC PWM method is proposed in order to achieve an easy application and to solve the redundant control problems encountered in the previous PSC PWM method. To verify the proposed PSC PWM method, PSCAD/EMTDC simulations for an 11-level MMC RTDS HILS test and an 11-level MMC prototype converter test were performed. As can be seen from the results of these tests, the proposed PSC PWM method shows good results in an 11-level MMC with redundant sub-modules.

Experiments on Steel Specimen for Concrete Crack Measurements (콘크리트 균열 탐사를 위한 철제시편 비교 실험)

  • Kim, Dae-You;Rhim, Hong-Chul;Cho, youn-jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.124-125
    • /
    • 2016
  • The various size and shape of cracks in concrete induce deterioration of reinforced concrete structures including nuclear power plants. The wider and deeper the crack is, the concrete structures are more vulnerable to carbonization. Thus, it is essential to develop a reliable measurement technique of cracks inside concrete. In this study, an ultrasonic test method is applied to the crack measurements. The results can be used for evaluation of existing reinforced concrete structures.

  • PDF

Study on Evaluation of High Temperature Degradation of Concrete using Ultrasonic Velocity Method (초음파 속도법을 이용한 콘크리트의 고온열화 평가에 대한 연구)

  • Hwang, Eui-Chul;Kim, Gyu-Yong;Choe, Gyeong-Cheol;Yoon, Min-Ho;Kim, Hong-Seop;Lee, Bo-Kyeong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.146-147
    • /
    • 2016
  • Concrete has been recognized as a material which is resistant to high temperatures, but chemicophysical property of concrete is changed by the high temperature. So, mechanical properties of concrete may be reduced. So, concrete at high temperature is evaluated mechanical properties for safety inspection. However, research of ultrasonic method is not much. Therefore, the purpose of this study is to NDT(non-destructive test) of 30, 70, 110MPa concrete exposed high temperature using ultrasonic pulse velocity.

  • PDF

A Study on the Development of a Single-Chamber Cardiac Pacemaker Tester (Single-Chamber 페이스메이커 테스터의 개발에 관한 연구)

  • Kang, B.Y.;Shin, J.W.;Yoon, Y.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.119-120
    • /
    • 1998
  • In this study, the design of the single-chamber pacemaker tester is presented. It is important to test the functions of the pacemaker before it is implanted into the patient. A pacemaker tester, that is presented in this study, is able to examine pacemaker parameters such as sensing threshold and refractory period. We need to make artificial intracardiac electrogram in order to test the pacemaker parameters. We know from the previous practical examples that a triangle pulse is similar to the physiologic intracardiac electrogram. The tester generates the simplified electrograms and PC software examines the output pulses of the pacemaker which is VVIR mode in closed-loop simulation.

  • PDF

NDT of Concrete Exposed High Temperature Using Ultrasonic Method (초음파법을 이용한 고온가열 콘크리트의 비파괴 평가)

  • Hwang, Eui-Chul;Kim, Gyu-Yong;Choe, Gyeong-Cheol;Yoon, Min-Ho;Kim, Hong-Seop;Lee, Bo-Kyeong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.24-25
    • /
    • 2016
  • Concrete has been recognized as a material which is resistant to high temperatures, but chemicophysical property of concrete is changed by the high temperature. So, mechanical properties of concrete may be reduced. So, concrete at high temperature is evaluated mechanical properties for safety inspection. However, research of ultrasonic method is not much. Therefore, the purpose of this study is to NDT(non-destructive test) of 30, 70, 110MPa concrete exposed high temperature using ultrasonic pulse velocity and amplitude.

  • PDF