• 제목/요약/키워드: Pulse test

검색결과 1,181건 처리시간 0.025초

맥박산소측정기(pulse oximetry)를 이용한 치수 생활력 측정과 기존 방법과의 비교 (Pulp Vitality Evaluation and Comparison with Old Methods Using Pulse Oximetry)

  • 권익재;서광석;김정욱;장주혜;공현중
    • 대한치과마취과학회지
    • /
    • 제12권1호
    • /
    • pp.17-23
    • /
    • 2012
  • Background: This study evaluated pulp vitality of anterior permanent teeth using pulse oximetry (PO), which is already used for monitoring of patient's $SpO_2$ and pulse rates (PR). Also we compared with ice tests and electric pulp test (EPT). Methods: 9 teeth, endodontic treated, were selected as non-vital teeth group. 17 vital teeth were selected as control group. Our aim is to compare sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of ice test, electric pulp test and pulse oximetry, respectively. Pulse oximetry has two test results, $SpO_2$ and pulse rates. Also we calculated correlation and statistical significances by Pearson's test between EPT and pulse oximetry. Results: Sensitivity, specificity, PPV, NPV were calculated on each tests. Ice test has results of 1.00, 0.89, 0.94 and 1.00, respectively. EPT has results of 0.94, 0.78, 0.89 and 0.88 respectively. $SpO_2$ has results of 0.94, 1.00, 1.00 and 0.90, respectively. PR has results of all 1.00. Conclusions: PO showed relatively accurate, stable and objective results on both $SpO_2$ and PR. Percentage of ability of accurate diagnosis for vital teeth is 94% for ice test, 89% for EPT, 100% for $SpO_2$ and PR. Percentage of ability of accurate diagnosis for non-vital teeth is 100% for ice test, 88% for EPT, 90% for $SpO_2$ and 100% for PR. In additions, PR could be more accurate and significant tests than $SpO_2$.

콘크리트의 초음파속도 시험식 제안 (A New Strength Equations of Concrete by Ultrasonic Pulse Velocity Test)

  • 유재은;박송철;김민수;권영웅
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.619-622
    • /
    • 2005
  • This study concerns the new strength equation of concrete by ultrasonic pulse velocity test. There are not only few estimate strength equations of concrete by ultrasonic pulse velocity test, but also many problems to apply them because of time,. cost, easiness, structural damage, reliability and so on. For this study, there performed a series of test and proposed equations as follows; Linear: ${\Large f}_{ck}=-193.15+60.97Vp\;r^2=77.9\%$ Quadratic : ${\Large f}_{ck}=276.85-189.64Vp+33.22Vp^2\;r^2=80.3\%$ here, $f_{ck}$ : Estimated compressive strength of concrete by MPa Vp : Ultrasonic Pulse Velocity of concrete by km/sec

  • PDF

이중충격파형 충격시험장비를 이용한 충격시험 결과 및 분석 (The Shock-Test Result and Analysis Using Dual-Pulse Shock Testing Machine)

  • 배종수
    • 한국군사과학기술학회지
    • /
    • 제21권3호
    • /
    • pp.342-348
    • /
    • 2018
  • The important issue of equipment installed in maritime weapon system is shock survivability against underwater explosion(UNDEX). If the shock survivability of equipment should not be guaranteed, the successful mission also could not be achieved. For that reason, the shock-resistance of each equipment under UNDEX environment should be demonstrated before deployment at combat field. However, the actual UNDEX test on the ocean is too expensive to conduct. Also, it has diverse dangerous factors. The main characteristic of UNDEX is a dual-pulse shock. The vertical shock test machine able to simulate dual pulse shock signal on the ground will be introduced in this paper. The dual-pulse shock signal presented in certain shock standard was achieved with this shock-test machine on the ground. The analytical procedure to set a test condition was verified by comparing simulation result with experiment result.

초음파시험법에 의한 콘크리트의 강도 추정 (A New Strength Equation of Concrete by Ultrasonic Pulse Velocity Test)

  • 유재은;박송철;김민수;권영웅
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.129-132
    • /
    • 2004
  • This study concerns the new strength equation of concrete by ultrasonic pulse velocity test. There are not only few estimate strength equations of concrete by ultrasonic pulse velocity test, but also many problems to apply them because of time, cost, easiness, structural damage, reliability and so on. For this study, there performed a series of test and proposed equations as follows; $$Linear\;:\;f_{kc}=65.43Vp-207.18\;r^2=80.8\%$$ $$Quadratic\;:\;f_{ck}=42.35Vp^2-250.71Vp+378.8\;r^2=83.7\%$$ here, fck : Estimated compressive strength of concrete by MPa Vp: Ultrasonic Pulse Velocity of concrete by km/sec.

  • PDF

월경장애를 가진 여고생의 맥진분석 (Analysis of Blood Pressure Pulse in Female High School Students with Menstrual Disorders)

  • 김수현;조혜숙;이인선
    • 대한한방부인과학회지
    • /
    • 제26권1호
    • /
    • pp.82-91
    • /
    • 2013
  • Objectives: The purpose of this study is to find out the patterns of teenage girls who is easy to suffer from Menstrual Disorders. Methods: The data from the 1681 participants were collected using a structured menstrual history questionnaire. Based on the survey responses, we had 97 adolescents with menstrual disorder as the test group and 97 adolescents without menstrual disorder as the control group. The clinical trials subjects were asked to respond to another questionnaire for identifying Blood Pressure Pulse Analyzer tests. We identified significant variables for dysmenorrhea from comparison between the test and control group; a binary response variable from the test group's responses for ever experiencing dysmenorrhea and explanatory variables from Blood Pressure Pulse Analyzer. Results: The reselts of Blood Pressure Pulse Analyzer test showed that the score of Energ_R, EIX_R were lower in dysmenorrhea group than the control group. The reselts of Blood Pressure Pulse Analyzer test showed that the score of Energ_R, EIX_R were lower, and T4_R were higher in hypomenorrhea group than the control group. The reselts of Blood Pressure Pulse Analyzer test showed that the score of Energ_R, EIX_R were lower in Irregular Menstruation group than the control group. Conclusions: Blood Pressure Pulse Analyzer test showed that the score of Energ_R, EIX_R were lower in the test group than the control group.

고출력 마그네트론 구동용 3.6 MW, $4\;{\mu}s$, 200 pps 펄스 모듈레이터 개발 (Development of a 3.6 MW, $4\;{\mu}s$, 200 pps Pulse Modulator for a High Power Magnetron)

  • 장성덕;권세진;배영순;오종석;조무현;남궁원;손윤규
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권3호
    • /
    • pp.120-126
    • /
    • 2005
  • The Korean Superconducting Tokamak Advanced Research (KSTAR) tokamak device is being constructed to perform long-pulse, high-beta, advanced tokamak fusion physics experiments. The long-pulse operation requires the non-inductive current drive system such as the Lower-Hybrid Current Drive (LHCD) system. The LHCD system drives the non-inductive plasma current by means of C-band RF with 2-MW CW power and 5-GHz frequency. For the LHCD test experiments, an RF test system is developed. It is composed of a 5-GHz, 1.5-MW pulsed magnetron and a compact pulse modulator with $4\;{\mu}s$ of pulse width. The pulse modulator provides the maximum output voltage of 45 kV and the maximum current of 90 A. It is composed of 7 stages of Pulse Forming Network (PFN), a thyratron tube (E2V, CX1191D), and a pulse transformer with 1:4 step-up ratio. In this paper, the detailed design and the performance test of the pulse modulator are presented.

Mechanical and Tribological Properties of Pulse and Direct Current Electrodeposited Ni-TiO2 Nano Composite Coatings

  • Gyawali, Gobinda;Woo, Dong-Jin;Lee, Soo-Wohn
    • 한국표면공학회지
    • /
    • 제43권6호
    • /
    • pp.283-288
    • /
    • 2010
  • Ni-$TiO_2$ nano composite coatings were fabricated using pulse current electrodeposition technique at 100 Hz pulse frequency with a constant 50% pulse duty cycles and reference was taken with respect to the direct current (dc) electrodeposition. The properties of the composite coatings were investigated by using SEM, XRD, Wear test and Vicker's microhardness test. Pulse electrodeposited composite has exhibited enhancement of (111), (220), and (311) diffraction lines with an attenuation of (200) line. The results demonstrated that the microhardness of composite coatings under pulse condition was significantly improved than that of pure nickel coating as well as dc electrodeposited Ni-$TiO_2$ composite coatings. Wear tracks have shown the less plastic deformation in pulse plated composite. Coefficient of friction was also found to be lower in pulse plated composite coatings as compared to dc plated composite coatings.

후방 충돌 펄스와 NCAP 펄스 차이로 인한 목상해 특성 비교 (Compare Characteristics of Neck Injuries between Rear Impact Pulse and NCAP Pulse)

  • 김종곤;박종호
    • 자동차안전학회지
    • /
    • 제9권3호
    • /
    • pp.7-12
    • /
    • 2017
  • The whiplash is the most important issue of low speed rear-impact. So auto makers are committed to developing a seat to improve whiplash injury. Most NCAP tests have been used by same pulse (Mid Velocity 16kph). Only Euro NCAP uses different pulse that consists of Low, Mid, High velocity. But Euro NCAP also uses same pulse in Mid velocity as other NCAP test. That Mid velocity NCAP pulse was made by rear impact that has 90's vehicle structure properties. That pulse was used until now days. However these days, auto maker use more high tensile steel than 90's as customer and society demand more fuel efficiency and light vehicle with good safety structure. So modern vehicles have different pulse patterns of rear impact than NCAP pulse and 90's vehicle crash properties. In this paper, the test was conducted by following condition. Target car was impacted by the rigid barrier with certain velocity. Finally target vehicle gained delta V 16kph which was same velocity as NCAP Mid Velocity pulse. It is critical velocity which occur long period neck injury. It is very different pulse that was gained by real car impact from NCAP pulse. And it has higher peak G with high fluctuation and short duration than NCAP pulse.

10% 리도카인 분무와 아로마 손 마사지가 혈액투석 동정맥루 천자 시의 통증, 불안, 혈압 및 맥박에 미치는 효과 (Effects of 10 % Lidocaine Spray and Aroma Hand Massage on Pain, Anxiety, Blood Pressure, and Pulse During Arteriovenous Fistula Needling in Hemodialysis Patients)

  • 송지미;박혜자
    • 재활간호학회지
    • /
    • 제19권1호
    • /
    • pp.1-11
    • /
    • 2016
  • Purpose: To determine the effects of 10 % lidocaine spray and aroma hand massage on pain, anxiety, blood pressure, and pulse during arteriovenous (AV) fistula needling in hemodialysis (HD) patients. Methods: This study used a quasi-experimental design. Forty HD patients were assigned to either 10 % lidocaine spray group (n=21) or aroma massage group (n=19). 10 % lidocaine was sprayed 3 times around AV fistula 10 minutes before. Aroma hand massage was performed for 5 minutes with fluids containing 2 % of lavender, peppermint, and geranium concentrate mixture. Pain, anxiety, blood pressure, and pulse were measured during AV fistula needling without any intervention on the first week and during interventions on the second week. Data were analyzed with ${\chi}^2$ test, Fisher's exact test, t-test, paired t-test and MANCOVA. Results: Pain and anxiety were significantly decreased in both the lidocaine spray group and aroma massage group. Aroma hand massage was more effective to reduce pulse during AV fistula needling. Conclusion: The results suggest that 10% lidocaine spray and aroma hand massage may be effective to reduce pain, anxiety, and pulse during AV fistula needling in HD patients.

결정질 암반의 투수량계수 도출을 위한 펄스시험의 적용성 연구 (Applicability of Pulse Tests to Estimate Transmissivity in Crystalline Rock)

  • 박경우;박병학;고낙열;지성훈
    • 지질공학
    • /
    • 제30권3호
    • /
    • pp.223-235
    • /
    • 2020
  • 본 논문에서는 결정질 암반에 건설된 지하연구시설에서 암반의 수리지질특성을 도출하기 위해 수행할 수 있는 현장수리시험의 방법으로 펄스시험을 소개하였다. 아울러 지하연구시설에서 수행한 슬러그시험과 펄스시험의 결과를 비교하여 결정질 암반의 수리지질특성 도출에 대한 펄스시험의 적용 가능성을 평가하였다. 펄스시험과 슬러그시험의 결과를 비교해 볼 때, 매질의 투수성이 낮은 시험구간에서는 그 결과가 매우 유사하게 도출되었지만 투수량계수가 1 × 10-8 ㎡/s 이상인 구간에서는 약간의 차이를 확인할 수 있었다. 이러한 투수성의 차이는 수리시험 시 적용되는 수리 영향 반경의 차이에서 기인한 것으로 판단된다. 또한 시험결과를 통하여 펄스시험을 투수량계수가 1 × 10-7 ㎡/s 이상인 시험구간에서 수행할 때, 시험 중 빠른 수두회복 때문에 정확한 시험결과를 도출하기 어렵다는 것을 알 수 있었다. 펄스시험은 비록 투수성이 큰 구간에서 수리지질특성을 도출하기 어렵지만, 저투수성 매질의 암반에서의 수리지질특성을 도출할 때 비교적 빠른 시간에 수리지질특성을 파악할 수 있는 경제적인 시험 방법이라고 제안할 수 있다.