• Title/Summary/Keyword: Pulse rate

Search Result 1,696, Processing Time 0.032 seconds

Method of a Multi-mode Low Rate Speech Coder Using a Transient Coding at the Rate of 2.4 kbit/s (전이구간 부호화를 이용한 2.4 kbit/s 다중모드 음성 부호화 방법)

  • Ahn Yeong-uk;Kim Jong-hak;Lee Insung;Kwon Oh-ju;Bae Mun-Kwan
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.2 s.302
    • /
    • pp.131-142
    • /
    • 2005
  • The low rate speech coders under 4 kbit/s are based on sinusoidal transform coding (STC) or multiband excitation (MBE). Since the harmonic coders are not efficient to reconstruct the transient segments of speech signals such as onsets, offsets, non-periodic signals, etc, the coders do not provide a natural speech quality. This paper proposes method of a efficient transient model :d a multi-mode low rate coder at 2.4 kbit/s that uses harmonic model for the voiced speech, stochastic model for the unvoiced speech and a model using aperiodic pulse location tracking (APPT) for the transient segments, respectively. The APPT utilizes the harmonic model. The proposed method uses different models depending on the characteristics of LPC residual signals. In addition, it can combine synthesized excitation in CELP coding at time domain with that in harmonic coding at frequency domain efficiently. The proposed coder shows a better speech quality than 2.4 kbit/s version of the mixed excitation linear prediction (MELP) coder that is a U.S. Federal Standard for speech coder.

Comparison of Motor Fitness of Cerebral Palsy Chidren with normal throug Phyisical Fitness Diagnosis Evaluation (체력진단 평가를 통한 뇌성마비 아동과 정상아동의 운동능력 비교연구)

  • Lee Kang-Jun;Park Rae-Joon;Kim Jong-Yul
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.1
    • /
    • pp.101-112
    • /
    • 2000
  • The aim of this study is to compared the cerebral palsy children with normal children in the exercise and cardio vascular ability after this study as the fundamental data fer mating programs for the cerebral palsy children. The test of this study is about twenty girls, the control group of the normal children(n=10) and the experiment group of cerebral palsy children(n=10). They were studied in four aspects which were the anthropometry, the medical check in the rest, the physical fitness or exercise roads test and the change of the target heart rate during exercise. The result were as follows : 1. The characteristic of the physical type : The control group is higher than the experiment group in the standing height and the body weight but their's little difference between them (p<0.05). The control group is lower than the experiment group in the body fat. 2. The characteristic of the medical check in the rest : The control group is higher than the experiment group in the vital capacity and flood expiratoryvolume one second. The control group is higher that the experiment group in the blood pressure of systolic and Diastolic. There's little difference between them(p<0.01). The control is lower than the experiment group in the heart pulse rate. There's little difference between them(p<0.005). 3. The characteristic of basic physical strength evaluation : The experiment group is the lowest dynamic muscular endurance, balance, agility and endurance which need to move the body with weight. The control group is much higher than the experiment group in the flexibility and muscle strength(Back strength). There's no difference between them(p<0.05). 4. The characteristics of the exercise stress last : The control group is higher than the experiment group in the endurance, the maximum of oxygen intake, endurance level and the out take of calory. There's little difference between them(p<0.01). 5. The characteristic of the change of the target heart rate during exercise : The control group is lower than the experiment group exchange of target heart rate, There's no difference them.

  • PDF

The Effect of Acupuncture Treated by Tonification and Sedation Manipulation at LI4 and KI7 on Lacking of Sweating in Cold Environment(II) (합곡(合谷) 복류(復溜) 보사(補瀉) 시술(施術)이 소한(少汗)에 미치는 영향(影響)(II))

  • Na, Chang-Su;Choi, Chan-Hun;Kim, Young-Sun;Kim, Wang-In;Youn, Dae-Hwan
    • Korean Journal of Acupuncture
    • /
    • v.27 no.2
    • /
    • pp.203-216
    • /
    • 2010
  • Objectives : The purpose of this study is to identify the effect of tonifying or sedative manipulation on LI4 and KI7 for sweet deficiency under cold environment. Methods : The participants were divided into 4 groups; intact group without acupuncture(Intact), acupuncture group inserting straightly with LI4 & KI7 method((LI4-straight KI7-straight), acupuncture group inserting twisting with LI4 tonificaton & KI7 tonificaton method(LI4-tonify KI7-tonify) and acupuncture group inserting twisting with LI4 sedation & KI7 sedation method(LI4-purge KI7-purge). We obtained the baseline data under cold condition with the temperature $14{\pm}1^{\circ}C$. After making the participant staying under cold condition for 10 minute, we measured sweating rate on skin surface and biological responses such as body temperature, oxygen saturation, pulse rate, systolic blood pressure, diastolic blood pressure, deoxy-Hb and oxy-Hb in subcutaneous. Results : The sweating rate on skin surface was not different in all treatment groups compared to the intact group. The body temperature was significantly increased in LI4-straight KI7-straight group compared to the intact group. The oxygen saturation significantly increased in LI4-purge KI7-purge group compared to the intact group. The systolic blood pressure was significantly increased in LI4-purge KI7-purge group compared to the intact group. The deoxy-Hb was significantly decreased in LI4-purge KI7-purge group compared to the intact group. Conclusions : The above results, the effect of LI4, KI7 acupuncture due to the tonifying or sedative manipulation on sweating control could be observed. However, other biological responses with the acupuncture of tonifying or sedative manipulation were giving different expressions. We suggest that continued research of tonifying or sedative manipulation is of importance order to find these expressions.

Performance analysis of SNR and BER for radiation pattern reconfigurable antenna (인체 부착용 방사패턴 재구성 안테나의 SNR 및 BER 성능 분석)

  • Lee, Chang Min;Jung, Chang Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4125-4130
    • /
    • 2015
  • This paper presents the communication performance for the radiation pattern reconfigurable antenna in the wearable device measuring bio signal (temperature, blood pressure, pulse etc.) of human body. The operational frequency is 2.4 - 2.5 GHz, which covers Bluetooth communication bandwidth. The maximum gain of the antennas is 1.96 dBi. The proposed antenna is efficiently transmitting and receiving signal by generating two opposite beam directions using two RF switches (PIN diode). Also, we investigated how radiation pattern changes according to three angles ($30^{\circ}$, $90^{\circ}$, $150^{\circ}$) of Top Loading. In this paper, we measured and compared the SNR (Signal-to-Noise Ratio) and BER (Bit Error Rate) performances of the proposed antennas in the condition between an ideal environment of anechoic chamber and smart house existing practical electromagnetic interferences (Universal Software Radio Peripheral, USRP). Throughout the comparing the results of the measurement of two cases, we found that the SNR is degraded over 5dB in average and BER is increased over ten times in maximum, therefore, it is confirmed that the error rate of receiving signal is increased. The measured results of SNR and BER value in this paper able to expect the performance degrading by the interference from the electromagnetic devices.

Effect of Virtual Reality Distraction on Pain and Anxiety in Children during Local Anesthesia (소아환자의 국소마취 시 Virtual Reality 주의분산이 통증 및 두려움에 미치는 효과)

  • Kim, Doosoo;Lee, Sangho;Lee, Nanyoung;Jih, Myeongkwan;Ahn, Jihye
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.95-104
    • /
    • 2021
  • The purpose of this study was to evaluate the effect of virtual reality distraction on pain and anxiety in children during local anesthesia. Local anesthesia was administered to 3 groups: a control group without distraction, a group watching TV, and a group using a virtual reality device. The pulse rate and oxygen saturation rate were measured before and at the time of local anesthesia to assess the patients' pain and anxiety, and the Wong-Baker Faces Pain Rating Scale was completed after local anesthesia. The group using the virtual reality device had a significantly lower heart rate change and lower Wong-Baker Faces Pain Rating Scale score than those in the control group and the group watching TV (p < 0.05). The greatest difference in heart rate change and Wong-Baker Faces Pain Rating Scale score, between the control and virtual reality distraction groups, was seen in 5 - 7-year-olds and a Frankl's behavior rating scale grade of 3. The virtual reality device alleviated pain and reduced anxiety in children during local anesthesia.

3D Printing-Based Ultrafast Mixing and Injecting Systems for Time-Resolved Serial Femtosecond Crystallography (시간 분해 직렬 펨토초 결정학을 위한 3차원 프린팅 기반의 초고속 믹싱 및 인젝팅 시스템)

  • Ji, Inseo;Kang, Jeon-Woong;Kim, Taeyung;Kang, Min Seo;Kwon, Sun Beom;Hong, Jiwoo
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.300-307
    • /
    • 2022
  • Time-resolved serial femtosecond crystallography (TR-SFX) is a powerful technique for determining temporal variations in the structural properties of biomacromolecules on ultra-short time scales without causing structure damage by employing femtosecond X-ray laser pulses generated by an X-ray free electron laser (XFEL). The mixing rate of reactants and biomolecule samples, as well as the hit rate between crystal samples and x-ray pulses, are critical factors determining TR-SFX performance, such as accurate image acquisition and efficient sample consumption. We here develop two distinct sample delivery systems that enable ultra-fast mixing and on-demand droplet injecting via pneumatic application with a square pulse signal. The first strategy relies on inertial mixing, which is caused by the high-speed collision and subsequent coalescence of droplets ejected through a double nozzle, while the second relies on on-demand pneumatic jetting embedded with a 3D-printed micromixer. First, the colliding behaviors of the droplets ejected through the double nozzle, as well as the inertial mixing within the coalesced droplets, are investigated experimentally and numerically. The mixing performance of the pneumatic jetting system with an integrated micromixer is then evaluated by using similar approaches. The sample delivery system devised in this work is very valuable for three-dimensional biomolecular structure analysis, which is critical for elucidating the mechanisms by which certain proteins cause disease, as well as searching for antibody drugs and new drug candidates.

Analysis of Basic Life Support Performance According to Video simulation training of EMT Students (응급구조과 학생의 동영상 시뮬레이션 교육에 따른 기본소생술 수행능력 분석)

  • Won, Young-Duck
    • The Korean Journal of Emergency Medical Services
    • /
    • v.15 no.3
    • /
    • pp.5-17
    • /
    • 2011
  • purpose : The purpose of this study was to analyze the effect of basic life support performance by video simulation training. Methods : The subjects in this study consisted of 24 persons of experimental group and 24 persons of control group in freshmen and sophomore EMT students. The data were collected from September 1 to 30, 2010. Results : 1. Hypothesis one: experimental group is meaningful higher than control group at the operation point (p<0.05) of adult/infant's basic life support for one person. In subcategory that identifying breath, artificial respiration, pulse rate, 30 compressions, Ability to perform all the processes, the experimental group showed statistically higher score (p<0.05) than control group, and sequence from checking reaction to keeping airway management isn't statistically significant difference between experimental group and control. 2. Hypothesis two: In the hypothesis, the experimental group's point of adult basic life support by two persons and use of Automated External Defibrillator is good in experimental group than control group's point(p<0.05). As the result of researching 11 contents of check list about adult basic life support by two persons and Automated External Defibrillator(AED), by dividing into 7 subcategories, every subcategory shows that the experimental group is significant higher than control group(p<0.05). 3. Hypothesis three: In the hypothesis, the experimental group gets higher point of infant basic life support by one or two persons than the control group (p<0.05). As the results of researching 15 contents of check list about infant basic life support by one or two persons, by dividing into 8 subcategories, the experimental group is statistically meaningful higher (p<0.05) than the control group in process of keeping airway, indentifying breathing, identifying pulse, 30 compressions, Ability to perform all the processes. There isn't statistically significant difference between the groups in process of checking reaction, reporting 119, and artificial respiration by giving 2 breaths(p<0.05). Conclusion : As summarizing the results, the group, receiving using video, gets higher points of knowledge of basic life support and operating skill than the general educated group. It is found that the Video simulation training could be effective, because of these positive effects to improve clinical working performance of students, who participate in the department of Emergency Medical Technology.

The Effect of the Exercise Performance of Yoga and Pilates on the Autonomic Nervous System (Yoga와 Pilates 운동 수행이 자율신경계에 미치는 영향)

  • Kim, Ji-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4450-4458
    • /
    • 2015
  • The purpose of this study was to examine the influence of the exercise performance of yoga and pilates on the autonomic nervous system in an effort to provide some clinical information on exercise prescription. The subjects were 20 selected college students who majored in P.E. A yoga group and a pilates group were organized with 10 students respectively, the autonomic nervous system of the students was measured before the exercise, immediately after that and 30 minutes after recovery. The findings of the study were as follows: First, there were significant differences in the yoga group's stress index and average pulse according to the main effect of the time and interaction effect between the time and group. Second, there were significant differences in the yoga group's sympathetic nervous system activity and autonomic nerve balance according to all the main effect of the time, interaction effect between the time and group and the main effect of group. Third, there were significant differences in HRV(Heart Rate Variability), parasympathetic nervous system activity, SDNN, and RMSSD according to the main effect of the time, and interaction effect between the time and group and the main effect of group produced no statistically significant differences. In conclusion, yoga seemed to be effective at lowering stress index and average pulse. Specifically, yoga exercise seemed to exert a more positive influence on the decrease of sympathetic nervous system activity and autonomic nerve balance than pilates exercise.

Design and operational characteristics of cw and KLM Ti : sapphire lasers with a symmetric Z-type cavity configuration (Z-형태의 대칭형 레이저 공진기 구조를 갖는 연속 발진 및 Kerr-렌즈 모드-록킹되는 티타늄 사파이어 레이저의 설계와 동작 특성)

  • Choo, Han-Tae;Ahn, Bum-Soo;Kim, Gyu-Ug;Lee, Tae-Dong;Yoon, Byoung-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.4
    • /
    • pp.347-355
    • /
    • 2002
  • We have constructed a high efficiency and broad tunable cw Ti:sapphire laser with a four-mirror symmetric Z-type laser cavity to increase the laser usability. From theoretical analyses and experimental data for a symmetric Z-type laser cavity containing a Kerr medium, the cavity mode size and the Kerr-lens mode-locking (KLM) strength for KLM lasers can be confirmed as function of the position in the cavity, the intracavity laser power, and the stability parameter. As a result, the slope efficiency and the maximum average output power of cw Ti:sapphire laser at 5 W pumping power of Ar-ion laser were 31.3% and 1420 ㎽ respectively. The tunablility was ranged from 730 ㎚ to 908 ㎚ with average output power above 700 ㎽. We obtained the KLM operation easily by self-aperturing effect in the Kerr medium and the slope efficiency and the maximum average output power of KLM Ti:sapphire laser was 16% and 550 ㎽ respectively. The spectral bandwidth was 33 ㎚ at the center wavelength of 807 ㎚ and the pulse width was 27 fs with a repetition rate of 82 ㎒.

Preparation of Porous K2Ti6O13 Whisker Preform by Spark Plasma Sintering (방전 플라즈마 소결법에 의한 다공성 육티탄산 칼륨 휘스커 프리폼의 제조)

  • Lee, Chang-Hun;Cho, Dong-Choul;Cho, Won-Seung;Lee, Chi-Hwan
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.12
    • /
    • pp.1197-1202
    • /
    • 2002
  • In order to develope the porous $K_2Ti_6O_13$ whisker preform with good strength, the pore characteristics and compressive strength were investigated as a function of spark plasma sintering temperature. As a result, high porous whisker preform were successfully fabricated by sintering at 900∼950${\circ}C$ for 10 min under a pressure of 40 MPa, heating rate of 50${\circ}C$/min and on-off pulse type of 12:2. The whisker preform prepared under above optimum condition showed relatively high compressive strength of 174∼266 MPa, despite of high porosity ranging from 15% to 37%. This improvement in strength was considered to be mainly due to the spark-plasma discharges and the self-heating action between whiskers. The compressive strength of whisker preform, fabricated at sintering temperature less than 900${\circ}C$, showed 80∼100 MPa. This is low strength level less than one half times compared with whisker preform fabricated at 900∼950${\circ}C$. The whisker preform fabricated at 1000${\circ}C$ showed the highest compressive strength of 523 MPa, but resulted in low porosity of ∼5%. Based on above results, it was considered that spark plasma sintering was an effective method for developing high strength and porosity of whisker preform.