• Title/Summary/Keyword: Pulse magnetic field

Search Result 151, Processing Time 0.028 seconds

Fast MR Imaging Technique by Using Locally-Linear Gradient Field (부분적인 경사자계를 이용한 고속 자기공명 영상촬영기법)

  • 양윤정;이종권
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.93-98
    • /
    • 1996
  • The purpose of this paper is to propose a new localized imaging method of reduced imaging time luting a locally-linear gradient. Since most fast MR(Magnetic Resonance) imaging methods need the whole $\kappa$-space(Spatial frequency space) data corresponding to the whole imaging area, there are limitstions in reducing the minimum imaging time. The imaging method proposed in this paper uses a specially-made gradient coil generating a local ramp-shape field and uniform field outside of the imaging areal Conventional imaging sequences can be used without any RF/gradient pulse sequence modifiestions except the change in the number of encoding steps and the field of view.

  • PDF

Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System (3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming)

  • Kim, P.K.;Lim, J.W.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.95-102
    • /
    • 2007
  • Purpose: To acquire high-resolution spiral-scan images at higher magnetic field, high homogeneous magnetic field is needed. Field inhomogeneity mapping and in-vivo shimming are important for rapid imaging such as spiral-scan imaging. The rapid scanning sequences are very susceptible to inhomogeneity. In this paper, we proposed a higher-order shimming method to obtain homogeneous magnetic field. Materials and Methods: To reduce measurement time for field inhomogeneity mapping, simultaneous axial/ sagittal, and coronal acquisitions are done using multi-slice based Fast Spin echo sequence. Acquired field inhomogeneity map is analyzed using the spherical harmonic functions, and shim currents are obtained by the multiplication of the pseudo-inverse of the field pattern with the inhomogeneity map. Results: Since the field inhomogeneity is increasing in proportion to the magnetic field, higher order shimming to reduce the inhomogeneity becomes more important in high field imaging. The shimming technique in which axial, sagittal, and coronal section inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the imhomogenity map is applied. The proposed technique is applicable to a localized shimming as well. High resolution spiral-scan imaging was successfully obtained with the proposed higher order shimming. Conclusion: Proposed pulse sequence for rapid measurement of inhomogeneity map and higher order shimming based on the inhomogeneity map work very well at 3 Tesla MRI system. With the proposed higher order shimming and localized higher order shimming techniques, high resolution spiral-scan images are successfully obtained at 3 T MRI system.

  • PDF

Mouse Somatosensory Cortex Stimulation Using Pulse Modulated Transcranial Magnetic Stimulation (구형파 변조된 경두개 자기자극을 이용한 쥐의 감각피질 자극실험)

  • Sun, Sukkyu;Seo, Taeyoon;Huh, Yeowool;Cho, Jeiwon;Kwon, Youngwoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.5
    • /
    • pp.482-485
    • /
    • 2016
  • In this work, a transcranial magnetic stimulation(TMS) experiment on animals is performed to stimulate the brain cortex of the mouse using modulated signals. The proposed TMS system is composed of the inverter, transformer, capacitor, variable inductor, and stimulation coil to generate 1.5 mT magnetic field in the brain cortex of the mouse. The stimulation signal is modulated to square wave where the carrier frequency is swept from 85 to 91 kHz to investigate the stimulation effect. The experimental result shows that when the carrier frequency of the stimulation signal is lower than 89 kHz, the reaction of the mouse does not change while the stimulation signal which has the carrier frequency higher than 89 kHz results in decreasing the threshold of the stimulus for the pressure.

Magnetron Sputter Coating of Inner Surface of 1-inch Diameter Tube

  • Han, Seung-Hee;An, Se-Hoon;Song, In-Seol;Lee, Keun-Hyuk;Jang, Seong-Woo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.135-135
    • /
    • 2015
  • Tubes are of extreme importance in industries as for fluid channels or wave guides. Furthermore, some weapon systems such as cannons use the tubes as gun barrels. To increase the service life of such tubes, a protective coating must be applied to the tubes' inner surface. However, the coating methods applicable to the inner surface of the tubes are very limited due to the geometrical restriction. A small-diameter cylindrical magnetron sputtering gun can be used to deposit coating layers on the inner surface of the large-bore tubes. However, for small-bore tubes with the inner diameter of one inch (~25 mm), the magnetron sputtering method can hardly be accommodated due to the space limitation for permanent magnet assembly. In this study, a new approach to coat the inner surface of small-bore tubes with the inside diameter of one inch was developed. Instead of using permanent magnets for magnetron operation, an external electro-magnet assembly was adopted around the tube to confine the plasma and to sustain the discharge. The electro-magnet was operated in pulse mode to provide the strong axial magnetic field for the magnetron operation, which was synchronized with the negative high-voltage pulse applied to the water-cooled coaxial sputtering target installed inside the tube. By moving the electro-magnet assembly along the tube's axial direction, the inner surface of the tube could be uniformly coated. The inner-surface coating system in this study used the tube itself as the vacuum chamber. The SS-304 tube's inner diameter was 22 mm and the length was ~1 m. A water-cooled Cu tube (sputtering target) of the outer diameter of 12 mm was installed inside of the SS tube (substrate) at the axial position. The 50 mm-long electro-magnet assembly was fed by a current pulse of 250 A at the frequency and pulse width of 100 Hz and 100 usec, respectively. The calculated axial magnetic field strength at the center was ~0.6 Tesla. The central Cu tube was synchronously driven by a HiPIMS power supply at the same frequency of 100 Hz as the electro-magnet and the applied pulse voltage was -1200 V with a pulse width of 500 usec. At 150 mTorr of Ar pressure, the Cu deposition rate of ~10 nm/min could be obtained. In this talk, a new method to sputter coat the inner surface of small-bore tubes would be presented and discussed, which might have broad industrial and military application areas.

  • PDF

NMR Study of larger proteins using isotope labeling

  • Park, Sung Jean
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.18 no.2
    • /
    • pp.47-51
    • /
    • 2014
  • Larger proteins (above molecular weight 50 kDa) usually show slow motional tumbling in solution, which facilitates the decay of NMR signal, resulting in poor signal-to-noise. In the past twenty years, researchers have tried to overcome this problem with higher molecular weight by improvement of hardware (higher magnetic field and cryoprobe), optimization of pulse sequences for lager molecules, and development of isotope-labeling techniques. Actually, GroEL/ES complex (${\approx}$ 900 kDa) was successfully studied using combination of above techniques. Among the techniques used in large molecular studies, the impact of isotope-labeling for large molecules study is summarized and discussed here.

Removal of NOx by Pulsed Streamer discharge (펄스 스트리머 방전을 이용한 NOx 제거)

  • 고희석;박재윤;김건호
    • Electrical & Electronic Materials
    • /
    • v.10 no.8
    • /
    • pp.807-811
    • /
    • 1997
  • In this paper we have investigated the removal characteristics of NOx by pulsed corona discharge with a multi-pointplane electrode where a magnetic field is applied in the discharge region. The efficiency of NOx removal was measured and analyzed as a function of pulse frequency gas flow rate NOx initial concentration magnetic flux density. In this result the highest removal efficiency of NOx was obtained at the following operating conditions; the frequency =400[Hz] gas flow =1[$\ell$/min] initial concentration= 400[ppm] and magnetic flux density=0.36[T].

  • PDF

Magnetic Design of the KT-2 Tokamak for "Advanced Tokamak" Studies

  • Lee, Kwang-Won;B. G. Hong;S. R. In;J. M. Han;B. J. Yoon;Kim, S. K.;Lee, Jae-Koo;Kim, Dong-Eon;Y. K. Ra
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.1033-1039
    • /
    • 1995
  • The magnetic system design of the KT-2 tokamak has been performed at KAERI. Design goal has been set to facilitate the so-called "advanced tokamak" studies, which is essential to secure the economy of the tokamak fusion reactors. Design features include a large-aspect-ratio machine configuration, long-pulse operation capability with heavy plasma shaping, hybrid magnetic field control and machine/in-vacuum structures for MHD stability.

  • PDF

Development of Prediction Algorithm for Replete Pulse and Vacuous Pulse by using Clip-type Pulsimeter with Hall Device Measuring a Magnetic Field (자기장 측정 홀소자 집게형 맥진기를 이용한 허맥과 실맥 예측 알고리즘 개발)

  • Lee, Nam-Kyu;Kim, Keun-Ho;Lee, Sang-Suk;Yu, Ji-Hye;Yu, Jun-Sang;Sun, Seung-Ho;Chang, Sei Jin;Hong, Yu-Sik
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.3
    • /
    • pp.104-109
    • /
    • 2013
  • Clip-type pulsimeter equipped with Hall device and a minute permanent magnet as sensing the minute movement of a radial artery was developed. The clinical data of the 120 number of subject acquisited through the clip-type pulsimeter did treated with a typical statistical logistic regression analysis. The prediction algorithm for the replete pulse and vacuous pulse was studied. The reflective peak time and the notch peak time were major parameters to discern the replete pulse and vacuous pulse. The discrimination rate was 65%. It suggests that the logistic regression equations are possible to use the diagnosis index to predict and discern the oriental pulse wave.

Determining plasma boundary in Alvand-U tokamak

  • Yahya Sadeghi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3485-3492
    • /
    • 2023
  • One of the major topic of tokamak research is the determination of the magnetic profile due to magnetic coil fields and plasma current by mean of data from magnetic probes. The most practical approach is to use the current filament method, which models the plasma column with multiple current carrying filaments and the total current of these filaments is equal to the plasma current. Determining the plasma boundary in Alvand-U tokamak is the main purpose of this paper. In order to determine the magnetic field profile and plasma boundary, information concerning the magnetic coils, their position, and current is required in the computing code. Then, the plasma shape is determined and finally the plasma boundary is extracted by the code. In the conducted research, we discuss how to determine the plasma boundary and the performance of the computing code for extraction of the plasma boundary. The developed algorithm shows to be effective by running it in the regular pc machine with characteristics of Intel (R) core (TM) i3-10100 CPU @3.60 GHz and 8.00 GB of RAM. Finally, we present results of a test run for computing code using a typical experimental pulse.

Design of RF Coil for Low Magnetic-Field Osteoblast Reformation System (저 자기장 조골세포 재형성 시스템용 RF 코일 설계)

  • Mun, Sung Hyuk;Cho, Choon Sik;Kim, Young-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.11
    • /
    • pp.821-827
    • /
    • 2018
  • In devices used for re-forming osteoblasts to treat osteoporosis, a magnetic field is applied from the outside of the bone, and the minerals contained in the bone are aligned in a certain direction and undergo precessional motion. When a $90^{\circ}$ RF pulse is applied by using an RF coil, protons of minerals are brought to an excited state, and phosphorus activity promoting the deposition of osteoblasts in the bone is increased, thereby reshaping the bone. Miniaturizing the RF coil that generates a signal corresponding to the harmonic of the precessional motional frequency by means of the $90^{\circ}$ RF pulse can drastically reduce the overall size of the bone reshaping system. In this study, we propose a methodology for the miniaturization of the RF coil that can be used for osteoblast re-formation using a bone reshaping system. The capacitance of the designed RF coil is 25 pF, the inductance is approximately 100 nH, and the resonance frequency is 96 MHz. The radius of the end ring of the designed RF coil is 18 cm, and the total length of the leg is $2{\times}11.6cm$. The performance of the coil is verified through post-design measurement.