• Title/Summary/Keyword: Pulse injection

Search Result 245, Processing Time 0.024 seconds

A Study on Home Nursing Care Requirement and Activities of Daily Life Among the Elderly at Home (재가노인의 가정간호요구도 및 일상생활능력에 관한 연구)

  • 조선화;김병성;김공현;박형종
    • Korean Journal of Health Education and Promotion
    • /
    • v.11 no.2
    • /
    • pp.125-145
    • /
    • 1994
  • The objectives of this study were to characterize the health status, the requirement of home nursing care, and dependency of daily life of the elderly so that the result could be used to provide basic data necessary for establishing home nursing care practices. The study subjects were 249 elders over 65 years old who resided at home in low income areas of three districts in Pusan. The field survey was conducted from December 27, 1993 through January 27, 1994, with a structured questionnaire. Statistical analysis was done by X²-test and Student's T-test using SPSS/PC/sup +/ program. The result were as follows; 1. Alcohol drinking rate was 50.0% for men and 27.7% for women, and cigarette smoking rate was 77.8% for men and 27.1% for women. 92.9% of elders aged 65-75 exercised regularly as compared to 81.9% of elders aged 75 and over(p<0.05). 2. 63.9% of male and 85.9% of female elders had chronic diseases showing singnificant differences(p<0.01), and both sexes had 1.7 kinds of chronic diseases in average; musculoskeletal diseases were the most common in 25.7%, while 6.8% of the elderly had cardiovascular diseases. 3. Partially movable elderly was 6.9% for men and 6.8% for woman, showing 47.1% of causes being cerebrovascular accidents. 4. The home nursing requirement was the highest for medication(66.3%), intramuscular injection(53.8%), and measurement of blood pressure·body·temperature·pulse rate(47.0%). 5. Among Physical Activities of Daily Life, bathing(10.4%) and movement(4.0%) showed high dependency rates, and among Instrumental Activities of Daily Life, phone calling(25.3%), shopping(24.5%), going out by bus(22.5%) showed high dependency rates. 6. For five categories of home nursing showing high requirements such as physical health examination, blood pressure·temperature·pulas rate measurements, medication, and intravascular injection, the requirements were different by age groups, education, and marital status(p<0.05).

  • PDF

Involvement of spinal muscarinic and serotonergic receptors in the anti-allodynic effect of electroacupuncture in rats with oxaliplatin-induced neuropathic pain

  • Lee, Ji Hwan;Go, Donghyun;Kim, Woojin;Lee, Giseog;Bae, Hyojeong;Quan, Fu Shi;Kim, Sun Kwang
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.20 no.4
    • /
    • pp.407-414
    • /
    • 2016
  • This study was performed to investigate whether the spinal cholinergic and serotonergic analgesic systems mediate the relieving effect of electroacupuncture (EA) on oxaliplatin-induced neuropathic cold allodynia in rats. The cold allodynia induced by an oxaliplatin injection (6 mg/kg, i.p.) was evaluated by immersing the rat's tail into cold water ($4^{\circ}C$) and measuring the withdrawal latency. EA stimulation (2 Hz, 0.3-ms pulse duration, 0.2~0.3 mA) at the acupoint ST36, GV3, or LI11 all showed a significant anti-allodynic effect, which was stronger at ST36. The analgesic effect of EA at ST36 was blocked by intraperitoneal injection of muscarinic acetylcholine receptor antagonist (atropine, 1 mg/kg), but not by nicotinic (mecamylamine, 2 mg/kg) receptor antagonist. Furthermore, intrathecal administration of $M_2$ (methoctramine, $10{\mu}g$) and $M_3$ (4-DAMP, $10{\mu}g$) receptor antagonist, but not $M_1$ (pirenzepine, $10{\mu}g$) receptor antagonist, blocked the effect. Also, spinal administration of $5-HT_3$ (MDL-72222, $12{\mu}g$) receptor antagonist, but not $5-HT_{1A}$ (NAN-190, $15{\mu}g$) or $5-HT_{2A}$ (ketanserin, $30{\mu}g$) receptor antagonist, prevented the anti-allodynic effect of EA. These results suggest that EA may have a significant analgesic action against oxaliplatin-induced neuropathic pain, which is mediated by spinal cholinergic ($M_2$, $M_3$) and serotonergic ($5-HT_3$) receptors.

Suppression of stray electrons in the negative ion accelerator of CRAFT NNBI test facility

  • Yuwen Yang ;Jianglong Wei ;Junwei Xie ;Yuming Gu;Yahong Xie ;Chundong Hu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.939-946
    • /
    • 2023
  • Comprehensive Research Facility for Fusion Technology (CRAFT) is an integration of different demonstrating or testing facilities, which aim to develop the critical technology or composition system towards the fusion reactor. Due to the importance and challenge of the negative ion based neutral beam injection (NNBI), a NNBI test facility is included in the framework of CRAFT. The initial object of CRAFT NNBI test facility is to obtain a H0 beam power of 2 MW at the energy of 200-400 keV for the pulse duration of 100 s. Inside the negative ion accelerator of NNBI system, the interactions of the negative ions with the background gas and electrodes can generate abundant stray electrons. The stray electrons can be further accelerated and dumped on the electrodes or eject from the accelerator. The stray electrons, including the ejecting electrons, cause the unwanted particle and heat flux onto the electrodes and the inner components of beamline (especially the temperature sensitive cryopump). The suppression of the stray electrons from the CRAFT accelerator is carried out via a series of design and simulation works. The paper focuses the influence of different magnetic field configurations on the stray electrons and the character of the ejecting electrons.

Controlled Surface Functionalities of metals using Femtosecond Laser-induced Nano- and Micro-scale Surface Structures (펨토초 레이저 유도 나노 및 마이크로 구조물을 활용한 금속 표면 기능성 제어)

  • Taehoon Park;Hyo Soo Lee;Hai Joong Lee;Taek Yong Hwang
    • Design & Manufacturing
    • /
    • v.17 no.2
    • /
    • pp.55-61
    • /
    • 2023
  • With femtosecond (fs) laser pulse irradiation on metals, various types of nano- and micro-scale structures can be naturally induced at the surface through laser-matter interaction. Two notable structures are laser-induced periodic surface structures (LIPSSs) and cone/spike structures, which are known to significantly modify the optical and physical properties of metal surfaces. In this work, we irradiate fs laser pulses onto various types of metals, cold-rolled steel, pickled & oiled steel, Fe-18Cr-8Ni alloy, Zn-Mg-Al alloy coated steel, and pure Cu which can be useful for precise molding and imprinting processes, and adjust the morphological profiles of LIPSSs and cone/spike structures for clear structural coloration and a larger range of surface wettability control, respectively, by changing the fluence of laser and the speed of raster scan. The periods of LIPSSs on metals used in our experiments are nearly independent of laser fluence. Accordingly, the structural coloration of the surface with LIPSSs can be optimized with the morphological profile of LIPSSs, controlled only by the speed of the raster scan once the laser fluence is determined for each metal sample. However, different from LIPSSs, we demonstrate that the morphological profiles of the cone/spike structures, including their size, shape, and density, can be manipulated with both the laser fluence and the raster scan speed to increase a change in the contact angle. By injection molding and imprinting processes, it is expected that fs laser-induced surface structures on metals can be replicated to the plastic surfaces and potentially beneficial to control the optical and wetting properties of the surface of injection molded and imprinted products.

Simultaneous Removal Characteristics of NOx, SOx from Combustion Gases using Pulse Corona induced Plasma Chemical Processing (PPCP에 의한 연소가스 중 NOx, SOx 동시제거 특성)

  • Park, Jae-Yoon;Koh, Yong-Sul;Jung, Jang-Gun;Kim, Jung-Dal
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.211-216
    • /
    • 2000
  • In this paper, experimental investigations were carried out to remove NOx, SOx simultaneously from a simulated combustion flue gas [$NO(0.02%)-SO_2(0.08%)-CO_2-Air-N_2$] by using a pulse corona induced plasma chemical processing. Discharge domain of wire-cylindrical plasma reactor was separated from a gas flow duct to avoid unstable discharge by aerosol particle deposited on discharge electrode and grounded electrode. The NOx, SOx removal was experimentally investigated by a reaction induced to ammonium nitrate, ammonium sulfate using a low price of aqueous NaOH solution and a small quantity of ammonia. Volume percentage of aqueous NaOH solution used was 20% and $N_2$ flow rate was $2.5{\ell}/min$ for bubbling aqueous NaOH solution. Ammonia gas(l4.82%) balanced by argon was diluted by air and was introduced to a main simulated flue gas duct through $NH_3$ injection system which was in downstream of reactor. The $NH_3$ molecular ratio(MR) was determined based on [$NH_3$] and [$NO+SO_2$]. MR is 1.5. The NOx removal rates increased in the order of DC, AC and pulse, but SOx removal rates was not significantly effected by source of electricity. The NOx removal rate slightly decreased with increasing initial concentration. but SOx removal rate was not significantly affected by initial concentration. The NOx, SOx removal rates decreased with increasing gas flow rate.

  • PDF

Blood Pressure, Pulse Rate and Temperature Changes of the Ipsilateral Upper Extremity after Unilateral Stellate Ganglion Block (편측 성상신경절 차단에 의한 혈압 맥박 및 상지 피부온도의 변화)

  • Goh, Joon-Seock;Min, Byung-Woo;Kim, Heung-Dae
    • The Korean Journal of Pain
    • /
    • v.3 no.1
    • /
    • pp.27-33
    • /
    • 1990
  • In the past decades there has been a growth of interest in the use of stellate ganglion block (SGB) as part of the diagnosis and therapy for the disease of the head, neck and upper extremities. For the evaluation of changes in hemodynamics and temperature of the affected extremity after the SGB, unilateral SGB (either right or left) was performed by local injection of 10 ml of 1% lidocaine without epinephrine in 45 patients (right side SGB: 25, left side SGB: 20) with various diseases. Systolic and diastolic blood pressure, pulse rate and skin temperature of the ipsilateral hand were studied before and 1, 2, 3, 4, 5, 10, 15, 30 and 60 minutes after the block. The results were as follows: 1) Changes of blood pressure: Systolic and distolic blood pressure after either right or left side SGB showed no statistically significant change. 2) Changes of pulse rate: While the left side SGB showed a mild decrease without statistical significance, the right side SGB showed a statistically significant decrease at 30 and 60 minutes after the block (p<0.05). 3) Changes of skin temperature of the blocked hand: Either side SGB produced a gradual increase in temperature with time and showed statistical significance from 10 minutes in the left side block (p<0.01), and a from 10 minutes after the block in the right side (p<0.01). Both sides SGB showed a maximal increase at 30 minutes after the block and a small decrease at 60 minutes after the block compared to the 30 minutes value. 4) Despite the successful SGB. 4 of 45 patients failed to produce a significant increase in skin temperature on the affected upper extremity. In conclusion, unilateral SGB with 1% lidocaine at the 6th cervical vertebral level is a safe method for use on an outpatient basis, and an increase in skin temperature in the affected upper extremity is necessary to confirm the successful therapeutic effect on disease of the upper extremity.

  • PDF

MICRO INJECTOR BASED ON DIGITAL DRIVE AND CONTROL FOR BIOMEDICAL ENGINEERING

  • Hou, Liya;Zhang, Weiyi;Mu, Lili;Zhu, Li
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2349-2351
    • /
    • 2003
  • This paper reports a novel microfluidic system, by which microfluidic delivery, transport and control can be digitally realized in femtoliter scale. Microelectronic grade $N_2$ from a pressurized canister was passed through HPLC tubing into a micro injector. The micro injector was driven and controlled digitally by the control system that can apply various control parameters such as pulse frequencies. A front-end of micro nozzle was inserted the dyed oil to collect droplets injected. The diameter of a droplet was measured by a microscope and a CCD camera, and then its volume can be calculated on the assumption that the droplet is spherical. The micro nozzles were simply pulled in glass capillary tubes by the micro puller self-made, and the geometry parameters of the micro nozzles can be adjusted easily. Experiments have successfully been carried out, and the results demonstrated that the proposed digital micro injector possesses three significant advantages : precise ultra-small liquid volume in femtoliter scale, digital microfluidic control and micro devices fabricated by simple glass process, not based on IC process.

  • PDF

Electrochemical Behaviors and Square Wave Voltammetric Determinations of Cefotaxime Sodium and Ceftriaxone Sodium (세포탁심나트륨과 세프트리악손나트륨의 전기화학 거동 및 네모파 전압전류법 정량)

  • Kim, Min-Kyung;Hahn, Young-Hee
    • YAKHAK HOEJI
    • /
    • v.50 no.1
    • /
    • pp.40-46
    • /
    • 2006
  • Square wave voltammetric (SWV) and cyclic voltammetric (CV) behaviors of cefotaxime sodium and ceftriaxone sodium have been investigated in the potential range between -0.10 V and -1.30 V using the phosphate buffers of various pH values ($2.00{\sim}9.10$). Two main peaks observed were irreversible and protons were involved in their electrochemical reductions. The first peaks of these cephalosporin antibiotics are due to the reduction of the azomethine double bond in the methoxyimino group of the side chain at position 7. The second peaks of cefotaxime sodium and ceftriaxone sodium are related to the reductions of the ${\Delta}^3$ double bond and the dioxo moiety of the side chain at position 3, respectively. The calibration curve of cefotaxime sodium in the concentration range between $1.0{\times}10^{-7}M$ and $1.0{\times}10^{-5}M$ yielded the linearity with the correlation coefficient of 0.9998 when the first peak of the antibiotic in a phosphate buffer of pH 3.02 was measured at the conditions of frequency of 120 Hz and pulse height of 50 mV by SWV. The present fast, simple and accurate SWV assay method was applied to determine cefotaxime sodium in the commercial antibiotic powder of injection.

A Voltage Control Technique of Line-Interactive DVR Using 7-Level H-Bridge Inverter (7-레벨 H-Bridge 인버터를 이용한 Line-Interactive DVR의 전압제어)

  • Kang, Dae-Wook;Hyun, Dong-Seok;Lee, Woo-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.705-715
    • /
    • 2007
  • Recently, the interest on power quality has been hot issue because the equipments cause voltage disturbance and have become more sensitive to the voltage disturbance. Additionally, the reseach on power electronic equipments applying to the high power has been increased. This paper deals with Line-Interactive Dynamic Voltage Restorer(LIDVR) system using 7-Level H-Bridge inverter, which is one of the solutions to compensate the voltage disturbance and to increase the power of equipments. The LIDVR has the following advantages comparing to the DVR with the series injection transformer. It has the power factor near to unity under the condition of normal source voltage, can compensate the harmonic current of the load and the instant interruption, and has the fast response. First, the construction, the operation mode and algebraic modeling of LIDVR are reviewed. And then the voltage control algorithm is proposed to get the sinusoidal load voltage with constant amplitude. Finally, simulation and experiment results verify the proposed LIDVR system.

NO Oxidation using Non-Thermal Plasma and NOx removal by NaOH-Water Solution Shower (비열플라즈마에 의한 NO의 산화와 NaOH 샤워해 의한 NOx의 제거특성)

  • Park, Jae-Yoon;Koh, Yong-Sul;Kim, Ick-Kewn;Park, Sang-Hyun;Koh, Hee-Seok;Lee, Duck-Chool
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.947-949
    • /
    • 1998
  • In this paper, the NO was oxidized $NO_2$ by using the non-thermal plasma and NOx removal characteristics were measured by showering NaOH water-solution to $NO_2$. The NO oxidation increased in the order of DC, AC, and Pulse. NOx oxidation for two stage with applied voltage was better than that for one stage with applied voltage. NO oxidation didn't depend on applied voltage. While NO oxidation was going on, NOx removal efficiency was 20-25%, however, significantly depended on the injection method of air and $H_2O$ + air. When NaOH water-solution density of 20% was showered to flue gases, NOx removal efficiency increased to 64%.

  • PDF