• Title/Summary/Keyword: Pulse imaging analysis

Search Result 65, Processing Time 0.028 seconds

Statistical Approach of Measurement of Signal to Noise Ratio in According to Change Pulse Sequence on Brain MRI Meningioma and Cyst Images (뇌 수막종 및 낭종에서 자기공명영상 펄스 시퀀스 변화에 따른 신호대잡음비의 통계적 접근)

  • Lee, Eul-Kyu;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Kim, Ki-Won;Son, Soon-Yong;Min, Jung-Whan;Son, Jin-Hyun
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.345-352
    • /
    • 2016
  • The purpose of this study was to needed basis of measure MRI CAD development for signal to noise ratio (SNR) by pulse sequence analysis from region of interest (ROI) in brain magnetic resonance imaging (MRI) contrast. We examined images of brain MRI contrast enhancement of 117 patients, from January 2005 to December 2015 in a University-affiliated hospital, Seoul, Korea. Diagnosed as one of two brain diseases such as meningioma and cysts SNR for each patient's image of brain MRI were calculated by using Image J. Differences of SNR among two brain diseases were tested by SPSS Statistics21 ANOVA test for there was statistical significance (p < 0.05). We have analysis socio-demographical variables, SNR according to sequence disease, 95% confidence according to SNR of sequence and difference in a mean of SNR. Meningioma results, with the quality of distributions in the order of T1CE, T2 and T1, FLAIR. Cysts results, with the quality of distributions in the order of T2 and T1, T1CE and FLAIR. SNR of MRI sequences of the brain would be useful to classify disease. Therefore, this study will contribute to evaluate brain diseases, and be a fundamental to enhancing the accuracy of CAD development.

Ultrasound Harmonic Imaging Method based on Harmonic Quadrature Demodulation (하모닉 직교 방식의 초음파 고조파 영상화 기법)

  • Kim, Sang-Min;Song, Jae-Hee;Song, Tai-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.79-88
    • /
    • 2009
  • A harmonic quadrature demodulation method to extract the second harmonic component from focused ultrasound signals after a single transmit-receive event is proposed. In the proposed method, the focused ultrasound signal is converted into baseband inphase and quadrature components by multiplying with sine and cosine signals both having twice the center frequency of the transmitted signal and filtering the two modulated signals. The quadrature component is then passed through a Hilbert filter to be added to the inphase component, which leaves only the envelope of the second harmonic component. A novel phase estimation technique is employed in the proposed method to avoid the phase mismatch between the focused signal and the two modulating signals. The proposed method is verified through both theoretical analysis and computer simulations. It is shown that compared to the pulse inversion scheme the proposed method provides almost the same results for stationary targets and significantly improved harmonic to fundamental ratio for moving targets.

Analysis of SAR Processing Performances with FJB Waveforms (FJB 파형을 이용한 SAR 영상 생성 기법 분석)

  • Kim, Eun-Hee;Roh, Ji-Eun;Park, Joon-Yong;Kim, Soo-Bum
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.3
    • /
    • pp.195-207
    • /
    • 2017
  • Recently, the SAR-GMTI mode is becoming increasingly essential in airborne radar systems. While SAR requires wideband waveforms for high resolution imaging, GMTI requires narrowband waveforms for doppler processing, which makes general LFM waveforms difficult to use for SAR-GMTI. This paper analyses the FJB(Frequency Jump Burst) waveform, which is studied for the SAR-GMTI waveform, and presents the method for the pulse compression and SAR image formation using FJB waveforms. Simulation results show that there is little difference in performances between the FJB waveform and the LFM waveform.

The Study of Lipid Proton Composition Change in a Rat Model of High Fat Diet Induced Fatty Liver by Magnetic Resonance Spectroscopy Analysis (고지방식이 유도성 지방간 쥐 모델에서 간의 자기공명분광 분석을 이용한 지질 양성자 조성 변화 연구)

  • Kim, Sang-Hyeok;Yu, Seung-Man
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.315-325
    • /
    • 2021
  • The purpose of this study is to investigate the changes in lipid proton (LP) composition according to the induced obese fatty liver and to use it as basic data for treatment and diagnosis of fatty liver in the future. The phantom study was conducted to identify differences between STEAM and PRESS Pulse sequences in LP concentration. A high-fat diet (60%) was administered to eight Sprague-Dawley rats to induce obesity and fatty liver disease. Baseline magnetic resonance imaging /spectroscopy data were obtained prior to the introduction of high-fat diet, and data acquisition experiments were performed after eight weeks using procedures identical to those used for baseline studies. The six lipid proton metabolites were calculated using LCModel software. The correlation between the fat percentage and each LP, revealed that the methylene protons at 1.3 ppm showed the highest positive correlation. The α-methylene protons to carboxyl and diallylic protons showed negative correlation with fat percentage. The methylene proton showed the highest increase in the LP; however, it constituted only 71.86% of the total LP concentration. The methylene proton plays a leading role in fat accumulation in liver parenchyma.

Wireless Triggering Pulse Generation for Digital X-ray Imaging System (디지털 x-ray 영상시스템을 위한 무선 트리거 발생기)

  • Ko, Dae-Sik;Lee, Jae-Cheol;Lee, Joo-Shin
    • Journal of Advanced Navigation Technology
    • /
    • v.11 no.2
    • /
    • pp.163-169
    • /
    • 2007
  • In this paper, we propose a method of trigger pulse generation to capture the image on time by making a synchronization between the x-ray generator and digital x-ray image acquisition system. we designed a wireless trigger pulse generation circuit to make a synchronization between x-ray generator and digital image acquisition system and analysis its performance. When it starts to detect a certain level of x-ray radiation or above from the air, this method starts to generate a ACQ_START signal to indicate the timing for image acquisition starting from digital image acquisition system. Hence, when it starts to detect under certain level of x-ray signal from the air, this method starts to generate a ACC_END signal to indicate the timing for image acquisition stop from digital image acquisition system. Image acquisition is activated only this time between ACQ_START and ACQ_END signal. By doing this wireless detecting of x-ray signal from remote, we can get more accurate timing for capturing the x-ray image and any type of x-ray generator can be connected to digital image acquisition system, regards of wired protocol. This makes easy installation. We could get 3.5 line pair / mm resolution at 20 mAs of x-ray level with resolution chart. This is same or better image comparing to conventional wired result.

  • PDF

Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System (3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming)

  • Kim, P.K.;Lim, J.W.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.95-102
    • /
    • 2007
  • Purpose: To acquire high-resolution spiral-scan images at higher magnetic field, high homogeneous magnetic field is needed. Field inhomogeneity mapping and in-vivo shimming are important for rapid imaging such as spiral-scan imaging. The rapid scanning sequences are very susceptible to inhomogeneity. In this paper, we proposed a higher-order shimming method to obtain homogeneous magnetic field. Materials and Methods: To reduce measurement time for field inhomogeneity mapping, simultaneous axial/ sagittal, and coronal acquisitions are done using multi-slice based Fast Spin echo sequence. Acquired field inhomogeneity map is analyzed using the spherical harmonic functions, and shim currents are obtained by the multiplication of the pseudo-inverse of the field pattern with the inhomogeneity map. Results: Since the field inhomogeneity is increasing in proportion to the magnetic field, higher order shimming to reduce the inhomogeneity becomes more important in high field imaging. The shimming technique in which axial, sagittal, and coronal section inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the imhomogenity map is applied. The proposed technique is applicable to a localized shimming as well. High resolution spiral-scan imaging was successfully obtained with the proposed higher order shimming. Conclusion: Proposed pulse sequence for rapid measurement of inhomogeneity map and higher order shimming based on the inhomogeneity map work very well at 3 Tesla MRI system. With the proposed higher order shimming and localized higher order shimming techniques, high resolution spiral-scan images are successfully obtained at 3 T MRI system.

  • PDF

An E-mail survey for expanding the basic benefit package of Korean medicine in Korean national health insurance (한의 의료행위 급여 항목 확대 방안 모색을 위한 전자우편 설문조사)

  • Kim, Mikyung;Kim, Ga-hee;Han, Chang-ho
    • The Journal of Korean Medicine
    • /
    • v.39 no.3
    • /
    • pp.51-60
    • /
    • 2018
  • Objectives: This study aimed to investigate the opinions of Korean medical doctors on how to elucidate possible remedial measures for expanding the health insurance benefits coverage item of Korean medicine (KM). Methods: An online survey was conducted to all members who had registered e-mail address in the association of Korean medicine from 1 to 17 November, 2016. Statistical analysis was performed and odds ratio with 95% confidence interval were calculated by each subgroup. Results: A total of 743 members answered the questions and the response rate was 4.1%. The priorities for expanding health insurance benefits were as follows: thermographic imaging, Sasang constitution typing test, and pulse wave among examinations; pharamacopuncture, embedding acupuncture, and acupotomy among procedures; Chuna manual therapy, manual therapy for meridian muscle, and Daoyin exercise therapy among manual therapies; low-frequency electrical therapy, traction, paraffin bath, and light therapy among physical therapies; and aromatherapy, enema therapy, and color therapy among activities of KM. Conclusions: It should be covered by the national health insurance (NHI) of KM that thermographic imaging, pharmacoacupuncture, Chuna manual therapy, low-frequency electrical therapy, aromatherapy as a top priority. We also suggest that basic medical tests, such as blood, urine, or imaging, should be included in the coverage of the NHI of KM. It is necessary to review the expertise and public opinions about the plans and priorities for the conversion of the desired medical services to be covered by the NHI.

A Study on Comparative Analysis of Diffusion Weighted Image Examination before and after Contrast Injection (조영제 사용 전 후 확산강조영상 검사의 비교 분석에 대한 연구)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.51-57
    • /
    • 2009
  • The purpose of this study would evaluate if having clinical effects on diffusion image with quantitative analysis through ADC values of brain's normal tissue and lesions before and after contrast injections using a 3.0T. From November in 2007 until December in 2008, a total of 32 patient was performed on 3.0T(Signa Excite, GE Medical System, USA) with the normal or lesions in the patient who requests diffusion weighted image with 8channel head coil. The pulse sequence was used with spin echo EPI(TR: 10000msec, TE: 72.2 msec, Matrix: 128*128, FOV: 240 mm, NEX: 1, diffusion direction: 3, b-value: 1000). Measurement results of ADC values on lesions, CSF, white matter, gray matter, lesions after contrast injection were measured less 75% than before contrast injection, infarction: 100%, CSF: 78%(high), white matter: 71.4%(low), gray matter: 50%(high, low). The results of paired t-test on the deference of ADC values which statically is significant in three(lesions, CSF, white matter)regions except for white matter(p<0.05). Quantitative analysis of lesions, CSF, white matter, gray matter have difference on all regions. ADC values were low in lesions and white matter, normal CSF after contrast injection commonly is high than before contrast injection, ADC values which white matter were high and low (50:50) after contrast injection. 3.0T diffusion weighted image clinically supposed that performing DWI examination after contrast injection was not desirable because of having effects on brain tissue.

  • PDF

a-Si:H Image Sensor for PC Scanner

  • Hur, Chang-Wu
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.2
    • /
    • pp.116-120
    • /
    • 2007
  • In this paper, the image sensor using the a-Si:H TFT is proposed. The optimum amorphous silicon thin film is deposited using plasma enhanced chemical vapor deposition (PECVD). TFT and photodiode both with the thin film are fabricated and form image sensor. The photodiode shows that $I_{dark}\;is\;{\sim}10^{-13}\;A,\;I_{photo}\;is\;{\sim}10^{-9}\;A\;and\;I_{photo}/I_{dark}\;is\;{\sim}10^4$, respectively. In the case of a-Si:H TFT, it indicates that $I_{on}/I_{off}\;is\;10^6$, the drain current is a few ${\mu}A\;and\;V_{th}\;is\;2{\sim}4$ volts. For the analysis on the fabricated image sensor, the reverse bias of -5 volts in ITO of photodiode and $70 {\mu}sec$ pulse in the gate of TFT are applied. The image sensor with good property was conformed through the measured photo/dark current.

A study on the debelopment of the Ultrasonic imaging system for tissue characterization (조직의 정량화를 위한 초음파 영상시스템의 개발에 관한 연구)

  • Choe, Jong-Ho;Choe, Jong-Su
    • The Journal of the Acoustical Society of Korea
    • /
    • v.6 no.3
    • /
    • pp.31-42
    • /
    • 1987
  • An ultrasonic pulse-echo diagnostic system for tissue characterization with the estimation of attenuation coefficients is developed and its performance has been examined by system implementation. The system divided into the ultrasonic generator, A/D converter, data communication, computer for signal processing. The methods for estimating the spatial distribution of acoustic attenuation coefficients using the moment analysis are proposed. The experimental results indicate the potential of the methods for tissue characterization.

  • PDF