• Title/Summary/Keyword: Pulse duration

Search Result 511, Processing Time 0.025 seconds

Generation of a High Voltage Pulse of 50 ns Pulse Duration using a Helical Blumlein Pulse Forming Line (나선형 블룸라인 PFL을 이용한 50 ns 펄스폭의 고전압 펄스 발생)

  • Roh, Youngsu;Jin, Yun-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.786-791
    • /
    • 2013
  • A high voltage pulse generator based on the Blumlein pulse forming line (PFL) was fabricated to produce a voltage pulse whose peak value is ~300 kV and pulse duration is ~50 ns. Three cylindrical electrodes, such as inner, middle, and outer electrodes, are concentrically placed to make a compact PFL. To increase the pulse duration of the output pulse without any change of the size of the generator, the middle electrode is replaced by a helical strip electrode. To determine the radius of the helical electrode, the impedance of the helical Blumlein PFL is calculated using an approximate formula where the dispersive property of the helical Blumlein PFL is not considered. The dependence of the impedance on the frequency is computed by a commercial program. The number of turns in the helical electrode is decided to provide a demanded pulse duration. The experimental result shows that the helical Blumlein PFL is capable of making a high voltage pulse of ~50 ns pulse duration.

Influence on Metal Removal Rate by Material and Size Difference of the Electrode (전극의 재료와 크기가 방전가공량에 미치는 영향)

  • 김희중
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.809-815
    • /
    • 1998
  • This study has been performed to investigate MRR(metal removal rate) surface roughness with various pulse-on duration using the copper and graphite electrode according to the electrode size on the heat treated STD 11 which is extensively used for metallic molding steel in the EDM. The results obtained are as follow ;a)MRR increases a lot when pulse-on duration is 100 $\mu{s}$ or less but MRR has little difference with pulse-on duration of 100 $\mu{s}$ or more b) According to the increase of Pulse-on duration the large the electrode size the more MRR c) Safe discharge is needed to make maximum of MRR and the metallic organization must be complicated for discharge induction. d) Actual machining time is longer than theoretical machining time at the short pulse-on duration because of skin effect of current. e) Graphite electrode needs the larger electric discharge energy than copper electrode to remove remained chips completely.

  • PDF

Muscle Force Potentiation During Constant Electrical Stimulation - Dependence on Pulse-Amplitude and Pulse-Duration of Electrical Stimulation (일정 전기자극하의 근력 상승 - 전기 자극 파형의 펄스 진폭과 펄스폭에 대한 의존성)

  • Kim, Ji-Won;Kwang, Min-Young;Eom, Gwang-Moon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.10
    • /
    • pp.458-463
    • /
    • 2006
  • The purpose of this work is to investigate the fundamental properties of the gradual muscle force potentiation. We investigated the dependence of force potentiation on both the pulse-amplitude and the pulse-duration with different ramp-up time. The experimental results showed that the force increment ratio (FIR) during constant electrical stimulation decreased with pulse-amplitude and also with pulse-duration. The FIR was greater with short ramp-up time in both the pulse-amplitude and pulse-width modulation. The feasible mechanism might be that the myosin light chain phosphorylation induces the force potentiation and it occurs only in the fast type muscle fibers which are recruited first. These observations indicate that muscle potentiation must be understood well for the accurate control of muscle force.

Muscle force potentiation during constant electrical stimulation - Dependence on pulse-amplitude and pulse-duration of electrical stimulation (일정 전기자극하의 근력 상승 - 전기 자극 파형의 펄스 진폭과 펄스폭에 대한 의존성)

  • Kim, Ji-Won;Kang, Min-Young;Kong, Se-Jin;Eom, Gwang-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2155-2156
    • /
    • 2006
  • The purpose of this work is to investigate the fundamental properties of the gradual muscle force potentiation for the prediction of muscle force and body movement from the stimulation input with musculo-skeletal model. We investigated the dependence of force potentiation on both the pulse-amplitude and the pulse-duration. The experimental result showed that the force increment ratio during electrical stimulation decreased with pulse-amplitude. The force increment ratio decreased with short pulse-duration and was maintained to be constant with pulse-duration longer than $500{\mu}s$. A new model of the muscle potentiation based on these results is desired in the future.

  • PDF

Production of Cloned Embryos by Nuclei Transfer and Electronic Cell Fusion from Bovine Fetal Fibroblasts (Bovine Fetal Fibroblasts를 이용한 핵이식 및 세포융합에 관한 연구)

  • 이병천;박종임;조종기;김기연;신수정;용환율;황우석
    • Journal of Embryo Transfer
    • /
    • v.14 no.2
    • /
    • pp.107-111
    • /
    • 1999
  • The present study was performed to evaluate the best electric fusion condition in nuclear transfer, Korean Native Cattle fibroblasts were used as nucleic donors. Oocytes from slaughterhouse were matured in vitro for 22 h and enucleated. Each individual cells were transferred into enucleated ocytes and reconstructed embryo were placed into the fusion chamber. In experiment 1, pulse were performed by altering pulse duration at 1. 75kv/cm, 1 time. When pulse duration is 30$mutextrm{s}$, fusion and development rates is higher than other conditions. In experiment 2, the effect of different pulse number were studied at the pulse duration 30$mutextrm{s}$ and the same pulse intensity. When pulse number was one, fusion rates were higher than other conditions. The fused embryos were moved to culture medium and assessed their development to blastocyst. These results showed that best fusion condition was 30$mutextrm{s}$ and one time. And the fibroblasts derived from Han Woo can be reprogrammed by nuclear transplantation and develop subsequently in vitro.

  • PDF

Biphasic Electrical Nerve Stimulator for Medical Applications Generating a Wide Range of Pulse Specifications Without Microcontroller

  • Jun Sang Yu;Dong Rim Kim;Su Bin Kang;Jung Suk Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.45 no.4
    • /
    • pp.173-178
    • /
    • 2024
  • We present an improved biphasic electrical nerve stimulator designed to overcome limitations. Traditional electrical nerve stimulators lacking a microcontroller unit (MCU) have restrictions in terms of frequency, pulse duration, and amplitude control, making them insufficient for medical applications requiring a broader range of pulse specifications. To address this, we developed a stimulator with enhanced capabilities. By not using an MCU, the design reduces power consumption and the required area, simplifying the overall design and increasing efficiency. In addition, our approach optimizes oscillator parameters to achieve wide frequency and pulse duration ranges. Specifically, we expanded the frequency range of the stimulator up to from 1 mHz to 100 kHz and the pulse duration up to from 5 ㎲ to 500 s. Improved amplitude control mechanisms were implemented for adjustable and high biphasic amplitudes. Furthermore, we added a balancing circuit to ensure proper discharging for tissue safety when biphasic pulses do not occur. The improved stimulator demonstrated an increase in operational range compared to traditional MCU-less designs, producing consistent biphasic pulses with adjustable amplitude and duration. The balancing circuit effectively managed discharging, reducing the risk of tissue damage and ensuring safety and efficacy.

Characteristics of Die Sinking Electical Discharge Machining for Pulse Duration (펄스지속시간에 따른 형상방전가공 특성)

  • 우정윤;왕덕현;윤존도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.827-831
    • /
    • 1997
  • Conductive veramic matrix composite(CMC) workpiece of TiC 33%/Al /sab 2/O /sab 3/ 66% Y /sab 2/ O /sab 3/ was machined by die sinking electrical discharge machining(EDM) according to different pulse duration and suty factor for reverse polarity of electrode. Material removal rate(MRR) was examined by process under various operating conditions. The surface morphology was evaluated by surface roughness values and scanning electron microscopy(SEM) research. The more MRR was obtained according to increase pulse duration and duty factor. Also the maximum surface roughness(Rmax) of EDMed surface was slightly changed with increased pulse duration and duty factor. The SEM photographs of EDMed surface showed wide recast wide recast distribution region of melting materials in purse duration 0.130(ms) than 0.048(ms).

  • PDF

Influence on EDM Surface with the Copper and Graphite Electrode According to the Discharge Energy (방전에너지에 따라 동전극과 흑연전극이 방전가공면에 미치는 영향)

  • Choi, Jae-Yong;Jeon, Eon-Chan;Jeong, Jae-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.5
    • /
    • pp.53-59
    • /
    • 1997
  • This study has been performed to inmvestigate MRR(metal removal rate), REW(relative electrode wear), surface roughness, heat transumutation layer and microhardness distribution in cross-section of the machined surface with various pulse-on duration and peak pulse current, using the copper and graphite electrode on the heat treated STD11 which is extensively used for metallic molding steel with the EDM. The results obtained are as follows; a) There exists critical pulse-on duration(If Ip equals 5A, .tau. on is 50 .mu. s) which shows the the maximum MRR in accordance with peak oulse current and the MRR decreases when the pulse-on duration exceeds the critical pulse-on during because of the abnormal electric discharge. b) Safe discharge is needed to make maximum of MRR and the metalic organization must be complicated for discharge induction. c) Graphite has much more benefits than copper electrode when rapid machining is done without electrode wear. d) The most external surface has the highest microhardness because of car- burizing from heat analysis of the dielectric fluid and the lower layar of the white covered layer has lower microhar dness than base matal because of softening.

  • PDF

A study of machining chracteristics effecting on laser focusing position in the ceramics microhole machining (세리믹 미세 구멍가공에서의 레이저 초점위치가 미치는 가공특성 연구)

  • Kim, Byoung-Yong;Lee, Kun-Sang
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.513-518
    • /
    • 2001
  • [ $Al_[2}O_{3}$ ] ceramics are generally used as components in processing equipment, devices or machinery. But it's difficult to machining as being machanical because $Al_[2}O_{3}$ ceramics are brittle materials. This study described a basic study of the input parameters effect on the dimension of the microhole at the $Al_[2}O_{3}$ ceramics using Nd:YAG laser. Major input parameters are peak power, pulse frequency and pulse duration in the laser microhole machining of $Al_[2}O_{3}$ ceramics. We will get a smaller microhole and diameter rate by an appropriate peak power, pulse duration.

  • PDF

Effect of Laser Acupuncture on Arterial Pulse

  • Cho, Jaekyong;Kang, Dong Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.191-197
    • /
    • 2015
  • Laser acupuncture is defined as the stimulation of traditional acupuncture points with low-intensity, nonthermal laser irradiation. Possible advantages in using laser acupuncture are the noninvasive, painless and low risks of infection treatment. The purpose of this study is to assess the effect of laser acupuncture on the quality and waveform of arterial pulses. Ten acupuncture points were stimulated repeatedly three times in 30 individuals by laser with emission in the near infrared spectral region (808 nm) using an out power and power density of 45 mW and $143W/cm^2$. The analysis of pulse quality and waveform was performed based on the measurement of arterial pressure of the left and right wrist, using a 3-dimensional blood pressure pulse analyzer. Excess-like pulse quality of subjects before laser acupuncture changed significantly to balanced pulse quality after 10, 20, and 30 minutes of laser acupuncture; coefficient of deficient or excess, $C_{DE}$, decreased significantly from 0.68 before acupuncture to 0.61, 0.55, and 0.55 after 10, 20, 30 minutes of laser acupuncture ($$p{\leq_-}0.006$$), respectively. Other pulse qualities, floating or sinking, slow or rapid, choppy or slippery did not change significantly by laser acupuncture (p > 0.05). Pulse waveform analysis showed that amplitude of main peak (systolic function or aortic compliance, $h_1$) of left and right artery pulse waves decreased significantly after 10, 20, and 30 minutes of laser acupuncture (p < 0.05). Other parameters, duration of one cardiac cycle (T), duration of rapid systolic ejection ($T_1$), duration of the systolic phase ($T_4$), and duration of the diastolic phase ($T_5$) of left and right artery pulses did not change significantly after laser acupuncture (p > 0.05).