• Title/Summary/Keyword: Pulse control

Search Result 2,244, Processing Time 0.026 seconds

Numerical and Experimental Verification of Stress Wave Control Effect in SHPB Experiment using Pulse Shaper (Pulse Shaper를 이용한 SHPB 실험 응력파 제어 효과의 해석 및 실험적 검증)

  • Kim, Y.H.;Woo, M.A.;Kang, B.S.;Kim, J.
    • Transactions of Materials Processing
    • /
    • v.26 no.5
    • /
    • pp.314-322
    • /
    • 2017
  • In the high-speed forming analysis, dynamic material properties considering a high strain rate are required. The split Hopkinson pressure bar (SHPB) experiment was performed for measuring dynamic material properties under high strain rate. The pulse shaping method was used to improve the accuracy of the SHPB experiment. A pulse shaper attached to the front of the incident bar was used for specimen dynamic stress equilibrium through stress wave control. Numerical analysis and SHPB test were performed to verify whether the pulse shaper affects the dynamic stress equilibrium in copper and Al6061 specimens. The results of SHPB test and numerical analysis show that the pulse shaper contributes to the dynamic stress equilibrium. Based on the improved stress equilibrium using a pulse shaper, the flow stress curves for copper and Al6061 materials were obtained at strain rates of 1344.4/sec and 1291.6/sec, respectively.

A Study on Pulse Diagnosis in Women with Polycystic Ovary Syndrome (PCOS) (Polycystic Ovary Syndrome(PCOS) 환자의 맥 분석 연구)

  • Park, Kyung-Dug;Bae, Ju-Eun;Yoon, Young-Jin
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.30 no.4
    • /
    • pp.77-88
    • /
    • 2017
  • Objectives: The purpose of this study is to analyze the characteristics of the pulse energy in women with PCOS (Polycystic ovary syndrome) compared with women who have a regular menstrual cycle. Methods: We analyzed the values of pulse energy on 20 patients with PCOS as an experimental group and 40 patients with regular menstrual cycle as a control group. Control group was divided into 20 women with follicular phase and 20 women with luteal phase respectively. Statistical analysis was performed using SPSS/Win 18.0, one way ANOVA and Tukey HSD. Results: The results were as follows. 1. The mean pulse energy of the Right Chon was significantly increased compared with those of the Left Kwan and the Right Kwan among PCOS group. 2. There were no statistically significant pulse energy among control groups. Conclusions: The pulse energy of Lung is bigger than that of Spleen and Liver in PCOS patients compared with women who have a regular menstrual cycle.

Predictive Current Control of 12-Pulse Parallel Connected Dual Converter System (12펄스 병렬 연결 듀얼 컨버터 시스템의 예측전류제어)

  • 이창원;송인호;최창호
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.405-408
    • /
    • 1998
  • In this paper, a predictive current control of 12-pulse parallel connected dual converter system with interphase transfromer(IPT) is presented. Firstly, 12-pulse parallel connected dual converter system and the predictive current control of this system is discussed. And the validity of the presented system and the excellence of the predictive current control response is proved through the simyulation and experiment result.

  • PDF

The Effect of Sa-Am Stomach Tonifying Acupuncture on Radial Pulse in Healthy Human Subjects (위정격(胃正格) 자침이 정상 성인의 맥파(脈波)에 미치는 영향)

  • Choi, Joo Young;Kang, Jae Hui;Yim, Yun Kyong;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.29 no.6
    • /
    • pp.57-71
    • /
    • 2012
  • Objectives : The purpose of this study is to find the effects of Sa-Am stomach tonifying acupuncture on radial pulse through the parameters difference. Methods : Forty healthy subjects participated in this study, acupuncture group and control group were divided. Radial pulse were measured using 3 dimensional pulse imaging system(DMP-3000). 19 parameters that significantly changed were selected after comparing between acupuncture group and control group. Then, 19 parameters were analyzed before, immediately after, 30 minutes after and 60 minutes after acupuncture in acupucture group. Results : 1. Heart rate, pulse period, T/T1, T2/T, T4/T, T5/T, T-T4, (T-T4)/T and T4/(T-T4) significantly changed after acupuncture. 2. H1 Amplitude, H2 Amplitude, H4 Amplitude and H5 Amplitude significantly changed after acupuncture. 3. Area of Pulse Wave, Systolic Pulse Area, Diastolic Pulse Area and Area of W significantly changed after acupuncture. 4. AIx/HR significantly changed after acupuncture. Conclusion : Stomach Tonifying Acupuncture exerts an influence on radial pulse parameters. Further radial pulse change study on various acupuncture treatment is required.

Improved performance of a linear pulse motor with repetitive positioning control

  • Sawaki, Jun;Matsuse, Kouki;Yamamoto, Shu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.389-392
    • /
    • 1996
  • We propose a method to improve repeatability positioning precision of a linear pulse motor. By using this method the systematic error which may make the precision worse can be suppressed easily. And also we show that Power OP-Amp drive system enables the accidental error to be suppressed in comparison with PWM control drive system using IGBT inverter. As a result of the suppression of systematic and accidental error, improved performance of a linear pulse motor with repetitive positioning control is shown by experimental results.

  • PDF

Implementation of automatic gain control circuit for the gain control of receiving stage in pulse doppler radar (펄스 도플러 레이다의 수신단 이득 제어를 위한 자동 이득 조절 장치의 구현)

  • 김세영;양진모;김선주;전병태
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.2
    • /
    • pp.10-20
    • /
    • 1997
  • This paper describes the design, the manufacture and the development of th eautomatic gain control unit which ajdusts the gain of IF processor in the high sensitive & multifunctional receiver unit (HMR) for pulse doppler radar system. Accodording to the effective distnce of target, radar cross section, and a lot of external environments (such as clutter), the receiving stage of RADAR system often deviates from dynamic range. To solve this kind o fproblem, continuous/pulse wave AGC are realized, make it possible to control the gain characteristics of receiver stably, and can increase dynamic range linearly by adjusting the gain slope of receiver which is limited by 1-dB gain compression point. In this study, AGC unit is designed to regulate the total gain of receiver by using te analog feedback theory. It also has rapid enough response to process pulse signal. This study presents the gain control method of IF, the real manufacture technique (the package-type components) and the measurement performance of AGC.

  • PDF

A Study on the Mode Conversion of Control in the Single Phase Switched Reluctance Motor (단상 SRM의 제어 모드 변환에 관한 연구)

  • Go, Sung-Chul;Ahn, Joon-Seon;Kim, Sol;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.635-636
    • /
    • 2006
  • A pulse with modulation(PWM) that keeps a constant angle of dwell and adjust duty ratio is a good method to control a speed of SRM. And a method of one pulse control is proper a operation on range of high speed in SRM for a good energy efficiency. Because PWM method is more safety than one pulse method, conversion of those is best choice according the speed range. So, some algorithm is need for smooth conversion of the mode of control. This paper presents a factor of conversion that proper the conversion of control mode between PWM and one pulse method This factor is from estimation of torque and proper at the variable range of conversion and show the better conversion characteristic than constant factor of conversion.

  • PDF

6펄스 콘버어터로 제어되는 초전도 에너지 저장장치에 의한 전력계통 안정화

  • 차귀수;한송엽;원종수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.8
    • /
    • pp.353-362
    • /
    • 1986
  • This paper shows that 6 pulse converter instead of 12 pulse converter can be used for the control of Superconducting Magnet Energy Storage(SMES) to improve the stability and to suppress the voltage fluctuation of power system. In order to prevent the commutation failure, when 6 pulse converter used for simultaneous control of real power and reactive power is asymmetrically controlled, stable control region has been presented by analyzing the commutation phenomena at critical points which distinguish the stable control region from the unstrol control region. Harmonic components of line current and output voltage have been calculated. Finally, computer simulation of power system stabilization has been presented to show the effectiveness of the proposed method. According to the computation results, SMES controlled by the 6 pulse converter is an effective measure in reducing the oscillation and the transient instability of the power system.

  • PDF

Current waveform Control of Pulse MAG Welding Power Source for High Speed Welding of Thin Plates (박판의 고속용접을 위한 펄스MAG 용접전원의 파형제어에 관한 연구)

  • Gu, Heon-Hoe;Kim, Tae-Jin;Kim, Jun-Hong;Lee, Hyeon-U;Jo, Sang-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.10
    • /
    • pp.571-578
    • /
    • 1999
  • Current waveform control of pulse MAG welding power source is studied so that welding of thin plates may obtain high speed and improved performance. In this paper, waveform control method is proposed, digital controller using DSP is able to control the current waveform precisely. High speed welding of thin plates using pulse MAG welding method is made possible. Performance test for 1.2mm thin plates is carried out, output waveform and welding performance is analyzed.

  • PDF

A Study on The PWM Control of Resonant Inverters (공진형 인버터의 PWM 제어에 관한 연구)

  • Shin, Jae-Hwa;Cho, Kyu-Min;Kim, Young-Seok
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.1
    • /
    • pp.53-60
    • /
    • 2001
  • In many applications of power electronics, high frequency resonant inverters are used, and the PAM(Pulse Amplitude Modulation), PFM(Pulse Frequency Modulation) or PWM(Pulse Width Modulation) techniques are used to control the output power of resonant inverters. And the resonant inverters have to control the output frequency for the reliable operation under the variable load conditions. In this paper, a new switching scheme is proposed as a PWM control of resonant inverters. With the proposed method, it can be obtained that optimum resonant frequency and unity output displacement factor under the variable resonant frequency adaptively. The detail algorithm or the proposed PWM switching scheme and its output characteristics are discussed. And the veridity of the proposed method is confirmed with the experimental results.

  • PDF