• Title/Summary/Keyword: Pulse compression technique

Search Result 22, Processing Time 0.022 seconds

Implementation of automatic gain control circuit for the gain control of receiving stage in pulse doppler radar (펄스 도플러 레이다의 수신단 이득 제어를 위한 자동 이득 조절 장치의 구현)

  • 김세영;양진모;김선주;전병태
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.2
    • /
    • pp.10-20
    • /
    • 1997
  • This paper describes the design, the manufacture and the development of th eautomatic gain control unit which ajdusts the gain of IF processor in the high sensitive & multifunctional receiver unit (HMR) for pulse doppler radar system. Accodording to the effective distnce of target, radar cross section, and a lot of external environments (such as clutter), the receiving stage of RADAR system often deviates from dynamic range. To solve this kind o fproblem, continuous/pulse wave AGC are realized, make it possible to control the gain characteristics of receiver stably, and can increase dynamic range linearly by adjusting the gain slope of receiver which is limited by 1-dB gain compression point. In this study, AGC unit is designed to regulate the total gain of receiver by using te analog feedback theory. It also has rapid enough response to process pulse signal. This study presents the gain control method of IF, the real manufacture technique (the package-type components) and the measurement performance of AGC.

  • PDF

An implementation of 60W X-band Cascade SSPA for Marine Radar System (선박 레이다용 60W X-band Cascade SSPA 구현)

  • Kim, Min-Soo;Jang, Yeon-Gil;Rhee, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • In this paper, An X-band solid state power amplifier(SSPA) for pulse compressed microwave signal with 60Watt power and power added efficiency(PAE) above 30% is described. Designed 60Watt high power amplifier(HPA) was implemented by cascade coupled amplifiers, and it is consisted on three stage drive amplifiers with internally matched GaAs FET and one stage main power amplifier with an internally matched GaN HEMT. The designed SSPA has performance with more than total power gain 37dB and output power 48dBm(60-W) in condition of frequency range $9.41{\pm}0.03GHz$, pulse period width under 1ms and duty cycle under 10%. The implemented SSPA can apply to high quality digital marine radar applications with pulse compression technique.

Discrimination of Air PD Sources Using Time-Frequency Distributions of PD Pulse Waveform (부분방전 펄스파형의 시간-주파수분포를 이용한 기중부분방전원의 식별)

  • Lee Kang-Won;Kang Seong-Hwa;Lim Ki-Joe
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.7
    • /
    • pp.332-338
    • /
    • 2005
  • PD(Partial Discharge) signal emitted from PD sources has their intrinsic features in the region of time and frequency STFT(Short Time Fourier Transform) shows time-frequency distribution at the same time. 2-Dimensional matrices(33$\times$77) from STFT for PD pulse signals are a good feature vectors and can be decreased in dimension by wavelet 2D data compression technique. Decreased feature vectors(13$\times$24) were used as inputs of Back-propagation ANN(Artificial Neural Network) for discrimination of Multi-PD sources(air discharge sources(3), surface discharge(1)). They are a good feature vectors for discriminating Multi-PD sources in the air.

Periodic Mixed Waveform Measurement Techniques for Compact Radar Transmitter with Phase-Continuous Signal (소형 레이더 송신기의 연속 위상을 갖는 주기성 혼합 파형 측정 기법)

  • Kim, So-Su;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.6
    • /
    • pp.661-670
    • /
    • 2013
  • In this paper, we propose the measurement techniques of mixed waveform. Mixed waveform has phase-continuous periodic waveform with fixed frequency signal and Linear Frequency Modulation(LFM) signal. This waveform is generated from a compact radar transmitter with frequency synthesizer and high power amplifier. Frequency synthesizer generates various signal waveform with continuos phase and high power amplifier amplify transmitting signal. First, we describe a compact radar transmitter with the phase-continuos signal and then verify the distortion characteristic of pulse compression by the mismatch of LFM waveform. Second, we describe three kinds of measurement techniques for measuring LFM waveform. These techniques include methods using signal analyzer, signal source analyzer and new methods using RF mixer and phase shifter. Finally, we verify the accuracy of the measurement technique from the pulse compression result of receiving signal.

가중 쳐프 신호를 사용한 초음파 고조파 영상 기법

  • 김동열;이종철;권성재;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.61-72
    • /
    • 2002
  • In this parer, a new harmonic imaging technique is Proposed and evaluated experimentally. In the Proposed method. a weighted chirp signal with a hanning window is transmitted. The RF samples obtained on each array element are individually compressed by correlating with the reference signal defined as the 2nd harmonic component($2f_0$) of a transmitted chirp signal generated in a square-law system. The correlator output will then consist of the compressed version of the $2f_0$ component generated in tissue and the crosscorrelation sequence of the fundamental($f_0$) and 2f$_{0}$components. The Proposed method uses the compressed $2f_0$ component to form an image. for which the crosscorrelation term should be suppressed below at least -50dB. The Proposed method has two process, 2f$_{0}$-correlation and $2f_0$-correlation(PI) . $2f_0$-correlation can successfully eliminate the $f_0$ component with a single transmit-receive events and therefore is more efficient than the conventional Pulse inversion method in terms of the frame rate. 2i)-correlation(Pl) Performs pulse compression after applying pulse inversion method for the 2nd harmonic image with high resolution and SNR. Another advantage of the proposed method is that the SNR of 2nd harmonic imaging can be improved without limitation by increasing the duration of the chirp signal. The proposed method was verified through both the computer simulations and actual experiments .ts .

A Voice Coding Technique for Application to the IEEE 802.15.4 Standard (IEEE 802.15.4 표준에 적용을 위한 음성부호화 기술)

  • Chen, Zhenxing;Kang, Seog-Geun
    • Journal of Broadcast Engineering
    • /
    • v.13 no.5
    • /
    • pp.612-621
    • /
    • 2008
  • Due to the various constraints such as feasible size of data payload and low transmission power, no technical specifications on the voice communication are included in the Zigbee standard. In this paper, a voice coding technique for application to the IEEE 802.15.4 standard, which is the basis of Zigbee communication, is presented. Here, both high compression and good waveform recovery are essential. To meet those requirements, a multi-stage discrete wavelet transform (DWT) block and a binary coding block consisting of two different pulse-code modulations are exploited. Theoretical analysis and simulation results in an indoor wireless channel show that the voice coder with 2-stage DWT is most appropriate from the viewpoint of compression and waveform recovery. When the line-of-sight component is dominant, the voice coding scheme has good recovery capability even in the moderate signal-to-noise power ratios. Hence, it is considered that the presented scheme will be a technical reference for the future recommendation of voice communication exploiting Zigbee.

Wideband Chirp Waveform Simulation and Performance Analysis for High Range Resolution Radar Imaging (고해상도 영상 레이다의 광대역 첩 신호 파형 발생 시뮬레이션과 성능 분석)

  • Kwag, Young Kil
    • Journal of Advanced Navigation Technology
    • /
    • v.6 no.2
    • /
    • pp.97-103
    • /
    • 2002
  • A recent technology trends in synthetic aperture radar(SAR) requires the ultra high resolution performance in detecting and precisely identifying the targets. In this paper, as a technique for enhancing the radar range resolution, the wide band chirp connection algorithm is presented by stitching the several chirp modules with unit bandwidth based on the linear frequency modulated chirp signal waveform. The principles of the digital chirp signal generation and its architecture for implementation is described with the wide band chirp signal generator, modulator, and demodulator. The performance analysis for the presented algorithm is given with the simulation results.

  • PDF

An Implement of Fixed Obstacle Detecting RADAR Algorithm for Smart Highway (스마트하이웨이에 적합한 장애물 탐지용 레이더 알고리즘 구현)

  • Lee, Jae-Kyun;Park, Jae-Hyoung
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.2
    • /
    • pp.106-112
    • /
    • 2012
  • Smart Highway is the intelligent highway that improves a traffic safety, reduces incidence of traffic accidents, and supports intelligent and convenient driving environment so that drivers can drive at high speeds in safety[1]. In order to implement the highway, it is required to gather a dangerous data such as obstacle, wild animal, disabled car, etc. To provide the situation information of the highway, it has been gathered traffic information using various sensors. However, this technique has problems such as the problems of various information gathering, lack of accuracy depending on weather conditions and limitation of maintenance. Therefore, in order to provide safe driving information to driver by gathering dangerous condition, radar system is needed. In this paper, we used a developing 34.5GHz RWR(Road Watch Radar) radar for gathering dangerous information and we verified performance of obstacle detecting and resolution through field test.

Block-Based Transform-Domain Measurement Coding for Compressive Sensing of Images (영상 압축센싱을 위한 블록기반 변환영역 측정 부호화)

  • Nguyen, Quang Hong;Nguyen, Viet Anh;Trinh, Chien Van;Dinh, Khanh Quoc;Park, Younghyeon;Jeon, Byeungwoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.12
    • /
    • pp.746-755
    • /
    • 2014
  • Compressive sensing (CS) has drawn much interest as a new sampling technique that enables signals to be sampled at a much lower than the Nyquist rate. By noting that the block-based compressive sensing can still keep spatial correlation in measurement domain, in this paper, we propose a novel encoding technique for measurement data obtained in the block-based CS of natural image. We apply discrete wavelet transform (DWT) to decorrelate CS measurements and then assign a proper quantization scheme to those DWT coefficients. Thus, redundancy of CS measurements and bitrate of system are reduced remarkably. Experimental results show improvements in rate-distortion performance by the proposed method against two existing methods of scalar quantization (SQ) and differential pulse-code modulation (DPCM). In the best case, the proposed method gains up to 4 dB, 0.9 dB, and 2.5 dB compared with the Block-based CS-Smoothed Projected Landweber plus SQ, Block-based CS-Smoothed Projected Landweber plus DPCM, and Multihypothesis Block-based CS-Smoothed Projected Landweber plus DPCM, respectively.

Multiple Transmit Focusing Method With Modified Orthogonal Golay Codes for Ultrasound Imaging (초음파 영상에서 변형된 직교 골레이 코드를 이용한 동시 다중 송신 집속 기법)

  • 김배형;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.217-231
    • /
    • 2003
  • Coded excitation with complementary Golay sequences is an effective means to increase the SNR and penetration of ultrasound imaging. in which the two complementary binary codes are transmitted successively along each scan-line, reducing the imaging frame rate by half. This method suffers from low frame rate particularly when multiple transmit focusing is employed, since the frame rate will be further reduced in proportion to the number of focal zones. In this paper. a new ultrasound imaging technique based on simultaneous multiple transmit focusing using modified orthogonal Golay codes is proposed to improve lateral resolution with no accompanying decrease in the imaging frame rate, in which a pair of orthogonal Golay codes focused at two different focal depths are transmitted simultaneously. On receive, these modified orthogonal Golay codes are separately compressed into two short pulses and individually focused. These two focused beams are combined to form a frame of image with improved lateral resolution. The Golay codes were modified to improve the transmit power efficiency (TPE) for practical imaging. Computer simulations and experimental results show that the proposed method improves significantly the lateral resolution and penetration of ultrasound imaging compared with the conventional method.