• 제목/요약/키워드: Pulse To Pulse Stability

검색결과 230건 처리시간 0.033초

Pulse-width Adjustment Strategy for Improving the Dynamic Inductor Current Response Performance of a Novel Bidirectional DC-DC Boost Converter

  • Li, Mingyue;Yan, Peimin
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.34-44
    • /
    • 2018
  • This paper presents a pulse-width adjustment (PWA) strategy for a novel bidirectional DC-DC boost converter to improve the performance of the dynamic inductor current response. This novel converter consists of three main components: a full-bridge converter (FBC), a high-frequency isolated transformer with large leakage inductance, and a three-level voltage-doubler rectifier (VDR). A number of scholars have analyzed the principles, such as the soft-switching performance and high-efficiency characteristic, of this converter based on pulse-width modulation plus phase-shift (PPS) control. It turns out that this converter is suitable for energy storage applications and exhibits good performance. However, the dynamic inductor current response processes of control variable adjustment is not analyzed in this converter. In fact, dc component may occur in the inductor current during its dynamic response process, which can influence the stability and reliability of the converter system. The dynamic responses under different operating modes of a conventional feedforward control are discussed in this paper. And a PWA strategy is proposed to enhance the dynamic inductor current response performance of the converter. This paper gives a detailed design and implementation of the PWA strategy. The proposed strategy is verified through a series of simulation and experimental results.

The effect of laser energy on the preparation of iron oxide by a pulsed laser ablation in ethanol

  • Maneeratanasarn, P.;Khai, T.V.;Choi, B.G.;Shim, K.B.
    • 한국결정성장학회지
    • /
    • 제22권3호
    • /
    • pp.134-138
    • /
    • 2012
  • Recently the preparation magnetic nanoparticles by a pulsed laser ablation in liquid has gained much attention because it is easy to control experimental parameters. Iron oxide magnetic nanoparticles have been prepared by a pulsed laser ablation of ${\alpha}-Fe_2O_3$ target in ethanol at different magnitude of laser energy of 1, 20, 40 and 80 mJ/pulse. It revealed that particle size increases with increasing laser energy. It could be concluded that 40 mJ/pulse is an optimum laser energy for the preparation of iron oxide nanoparticles with uniform size distribution. The nanoparticles are homogeneously dispersed in ethanol and their stability maintained for several months.

SS-OCT용 정현파 및 트리거 펄스 발생기 (Sine-wave and Trigger Pulse Generator for SS-OCT)

  • 엄진섭
    • 센서학회지
    • /
    • 제24권6호
    • /
    • pp.398-403
    • /
    • 2015
  • In this paper, the sine-wave and trigger pulse generator with capability of frequency high-resolution and time-variable trigger edge has implemented. It fulfills well the requirements for SS-OCT with frequency resolution of 1 Hz, frequency stability of ${\leq}{\pm}0.03Hz$ and time-variable trigger edge. Through its performance test applied to the wavelength swept laser, 90 nm, sweeping range and 10mW average optical power were obtained. This showes that the realized generator can replace the commercial high cost and high performance signal generators employed by current SS-OCT systems.

Optimization of Wave Forms for Pulsed Amperometric Detection of Cyanide and Sulfide with Silver-Working Electrode

  • 박성우;홍성욱;유재훈
    • Bulletin of the Korean Chemical Society
    • /
    • 제17권2호
    • /
    • pp.143-146
    • /
    • 1996
  • A continuous potential pulse is applied to a silver-working electrode on a pulsed amperometric detector (PAD) for detection of free cyanide and sulfide. The moving phase is 0.1 M sodium hydroxide, 0.5 M sodium acetate and 5% (v/v) ethylenediamine mixture, and the flow rate is 0.7 mL/min. Optimized pulse conditions include a -200 mV (vs. Ag/AgCl reference electrode) detection potential(Ed) for 60 msec and 50 mV cleaning potential (Ec) for 120 msec. The silver working electrode surface is not poisoned by cyanide or sulfide, and the PAD maintains long-term stability without loss of sensitivity and reproducibility at these pulse conditions. The detection limit of cyanide and sulfide separated by ion chromatography using an anion exchange column is 0.1 ppm and 0.05 ppm, respectively.

XFEL용 인버터 고전압 전원공급장치를 이용한 펄스전원공급장치 연구 (Study On the Pulse Power Supply using Inverter Power Supply for XFEL)

  • 박성수;김상희;김성철;한영진;황정연;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.198-200
    • /
    • 2005
  • The 2.5 GeV linac of the Pohang Light Source(PLS) is planed to be converted to a XFEL. The PAL XFEL requires a new 1.2-GeV linac that will be combined to the existing linac to increase a beam energy upto 3.7 GeV. The RF stability of 0.02 % is required for both RF phase and amplitude to get the XFEL output. This stability is mainly determined by a low level RF drive system and klystron-modulators. The stability level of the modulator has to be improved 10 times better to meet the pulse stability of 0.02 %. The regulation methods such as traditional de-Qing and precision inverter charging technology are reviewed to find out suitable upgrade scheme of the modulators.

  • PDF

프레임 장성이 차량의 조종안정서에 미치는 영향 (Effects of Chassis Frame Stiffness on Vehicle Handling Characteristics)

  • 이병림
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.100-105
    • /
    • 2002
  • In order to investigate how the chassis frame stiffness including body structure affects vehicle handling characteristics, in this paper, objective test evaluations such as steady state circle maneuvering test and pulse input transient test are performed. The basic steer characteristics can be obtained from stability factor and 4 parameter method is used to evaluate vehicle handling characteristics between original vehicle and the other with reinforced chassis. The result shows that vehicle with reinforced chassis has advantages in handling characteristics.

Determination of Stability Constants Using Electrochemical Methods for the Complex Formation of Platinum and Palladium with Polyelectrolytes

  • Park, Joon Seo;Chung, Koo Soon
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.691-698
    • /
    • 1995
  • The complexation of platinum and palladium with synthetic polyelectrolytes was studied. The successive and overall stability constants of Pd(II) with PEI and 2PVP were obtained by potentiometric titration. Because of the slow equilibrium time, the potentiometric titrations were performed using the home-made automatic titrator in order to analyze the complexations according to the modified Bjerrum method. The complex formation constant of Pt(IV) with 2PVP, measured by differential pulse polarography, was calculated from the peak currents that were obtained in non-complexing media and in solution containing 2PVP.

  • PDF

연소 안정성 평가 시험을 통한 배플 길이의 안정성 여분 평가

  • 김홍집;이광진;서성현;김승한;한영민;설우석
    • 항공우주기술
    • /
    • 제3권1호
    • /
    • pp.188-196
    • /
    • 2004
  • 수동제어기구로서 사용되는 배플의 축방향 길이의 최적화 및 한계를 평가하기 위하여, 축방향 길이를 작동인자로 하여 연소 안정성 여분을 평가하였다. 외부 교란 발생 장치로서 2번의 기폭이 가능한 펄스건을 사용하였다. 외부 교란에 대한 연소실에서의 응답 특성을, 감쇠 시간과 진폭비와 같은 인자를 도입하여 정량화하였다. 설계점과 탈설계점에서 시험을 수행하였으며, 분사기의 충돌점으로 생각할 수 있는 화염 영역을 감싸지 못하는 경우에는 배플의 충분한 감쇠 능력을 보장할 수 없음을 확인하였다. 따라서 연소 안정성의 여분의 경계는 50mm 정도의 배플인 것으로 판단되었다.

  • PDF

Investigation on stability characteristics of 2G HTS coated conductor tapes with various stabilizer thickness

  • Quach, Huu Luong;Kim, Ji Hyung;Hyeon, Chang Ju;Chae, Yoon Seok;Moon, Jae Hyung;Kim, Ho Min
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권1호
    • /
    • pp.19-22
    • /
    • 2018
  • The thermal and electrical properties of the conductor are critical parametersfor the design and optimization of the superconducting magnet. This paper presents simulation code to analyze electrical and thermal stability characteristics of the second generation (2G) high-temperature superconductor (HTS) by varying copper stabilizer thickness. Two types of commercial 2G HTS coated conductor tapes, YBCO and GdBCO were used in this study. These samples were cooled by Liquid Nitrogen ($LN_2$) having boiling at 77.3 K and an equivalent electrical circuit model for them is choosen and analysed in details. Also, an over-current pulse test in which a current exceeding a critical current was performed. From the simulation results, the influences of the copper stabilizer thickness on the stability characteristics of these samples are presented.

반능동형 레이저 유도 추적에 적합한 레이저 펄스 반복 주파수 검출을 위한 디지털 신호처리 보드 구현 및 표적 좌표 최적화 (Implementation of Digital Signal Processing Board Suitable for a Semi-active Laser Tracking to Detect a Laser Pulse Repetition Frequency and Optimization of a Target Coordinates)

  • 이영주;김용평
    • 전기학회논문지
    • /
    • 제64권4호
    • /
    • pp.573-577
    • /
    • 2015
  • In this paper, we propose a signal processing board suitable for a semi-active laser tracking to detect an optical signal generated from the laser target designator by applying an analog trigger signal, the quadrant photodetector and a high speed ADC(analog-digital converter) sampling technique. We improved the stability by applying the averaging method to minimize the measurement error of a gaussian pulse. To evaluate the performances of the proposed methods, we implemented a prototype board and performed experiments. As a result, we implemented a frequency counter with an error 14.9ns in 50ms. PRF error code has a stability of less than 1.5% compared to the NATO standard. Applying the three point averaging method to ADC sampling, the stability of 28% in X-axis and 22% in Y-axis than one point sampling was improved.