• Title/Summary/Keyword: Pulse Pressure

Search Result 1,215, Processing Time 0.027 seconds

A study on the pulse boiling occurring inside the liquid pool of a closed two-phase thermosyphon (밀폐형 2상 열사이폰의 Pool 내부 Pulse Boiling에 관한 연구)

  • Kim, Cheol-Ju;Mun, Seok-Hwan;Gang, Hwan-Guk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1254-1261
    • /
    • 1997
  • Pulse boiling, the unsteady periodic boiling phenomenon appearing in the evaporator of thermosyphons was investigated by many researchers. In the present study investigations were conducted to examine the evolution of flow patterns at the evaporator, and changes in thermodynamic state that each of liquid pool and vapor experiences through 1 cycle of pulse boiling process. For wall and liquid pool the degree of superheat for the onset of nucleation was examined. It revealed that the degree of superheat increased with the increase of pulse period, reaching to 16.5 deg.C and 23 deg.C for liquid pool and evaporator wall respectively at .tau.=80 sec. The data on flow patterns obtained through series of operation tests were plotted in the coordinates of heat flux and vapor pressure to get a regime map. Further this map could be used to figure out the conditions of pulse boiling for a thermosyphon.

The Ablation Effect of Fabric/EPDM Rubber with Manufacturing process (Fabric/EPDM계 고무의 제작 공정에 따른 삭마 특성)

  • Kim, Jin-Yong;Rho, Tae-Ho;Lee, Won-Bok;Cho, Won-Man;Rhee, Young-Woo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.92-95
    • /
    • 2012
  • The dual pulse rocket motor is a pressure vessel containing two pulse grains separated by a pulse separation device such as a fragile bulkhead. One of the important things in this systems is case insulation design using the excellent materials in the 1st stage pulse motor. We investigated manufacturing process of fabric/EPDM chamber insulations in order to protect the 1st stage pulse motor case with high intensity gas flow. Simulation motor connected with extension tube having FRP disc was designed to study ablation characteristics of insulation.

  • PDF

Finite Element Analysis of Pressure Distribution by Ultrasound in Human Thigh Model (대퇴부 모델에서의 초음파 압력분포에 관한 유한요소 해석)

  • Choi, Ho-Seon
    • The Journal of Information Technology
    • /
    • v.8 no.1
    • /
    • pp.43-50
    • /
    • 2005
  • Quantitative analysis for distribution of penetrating ultrasound in vivo is very important to determine the treatment region and method. In this paper, we constructed a simplified 2-D femoral region model that consists of skin-fat-muscle-bone layered system, and simulated the pressure distribution in the model in case of applying ultrasound using Finite Element Method(FEM). The ultrasound used in the simulation was assumed to be pulse wave and the pressure distribution was analyzed during only one period of pulse wave. In order to find the penetration depth, amplitude of pressure and sphere that ultrasound reaches in the model, we performed the simulation with varying the applied frequency, transducer size and amplitude of transducer's output. The result showed that applied frequency is inversely proportional to the penetration depth and amplitude of pressure but the amplitude of transducer's output is proportional to the amplitude of pressure in the model. Also, the sphere that ultrasound reaches was widened and the amplitude of pressure became larger as the transducer size became larger. This results were similar to that obtained from the previous model consisting of fat-muscle-bone layered system, but we observed that the pressure of ultrasound is decreased due to the decrements of pressure by the absorption coefficient of skin and the interference that depends on the reflection of ultrasound caused by the difference of acoustic impedance of skin and fat. Finally, we can infer that the model proposed in this study is closer to the realistic model than the previous ones. It shows that the results obtained from this study can be useful in designing the ultrasound treatment instrument or in setting up the treatment plan.

  • PDF

The quantitative study on the Renying·Qi mouth comparison pulse diagnosis (인영(人迎)·기구비교맥법(氣口比較脈法)의 정량화(定量化)에 관(關)한 연구(硏究))

  • Cho, Myung-Rae;Kim, Moo-Shin;Ryu, Choong-Ryul;Choi, Chan-Hun;Jang, Kyeong-Seon;So, Cheol-Ho;Park, Young-Dae
    • Journal of Acupuncture Research
    • /
    • v.19 no.2
    • /
    • pp.149-163
    • /
    • 2002
  • Objective : We have studied literatures of Renying Qi mouth comparison pulse diagnosis theory and distinguished the excess, deficiency and quick-temper of pulse as the measurement parameter of Renying Qi mouth pulse diagnosis. Methods : We have acquired pulse signals of Renying Qi mouth by using diagnostic equipment of Renying Qi mouth pulsation and estimated reappearance of pulse signals. Results : 1. The measurement parameter of Renying Qi mouth pulse diagnosis distinguishes the excess, deficiency and quick-temper of pulse through relative comparison of Renying Qi mouth. 2. When we acquired the pulse singals of Renying Qi mouth by using diagnostic equipment, the property, measuring area, bias pressure, contact or adhesion state of the sensor are considered. 3. As getting the pulse signal of Renying Qi mouth, the sensor of a sound detective mode is effective. 4. The diagnostic equipment of Renying Qi mouth pulse is assessed as being significant reappearance.

  • PDF

A Study on the Estimation of Blood Pressure Based on the Magneto-Plethysmography for Smart Healthcare (스마트 헬스케어를 위한 자계용적맥파 기반 혈압 추정에 관한 연구)

  • Lee, Seong-Su;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Hyeok-Jae;Lee, Byoung-Hun;Kim, Kyeoung-Seop;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.917-927
    • /
    • 2018
  • High blood pressure causes various cardiovascular diseases and is associated with mortality. Periodic self-monitoring and recording of blood pressure is very helpful in preventing the occurrence of secondary diseases caused by hypertension. However, existing cuff-type blood pressure monitors have many limitations. As an alternative of that, a method of estimating the blood pressure by measuring the velocity change of the blood flow using the photo plethysmography is widely known. However, photo plethysmography have a low correlation with blood flow. So, we will propose an algorithm for estimating blood pressure using the relationship between velocity change of blood flow measured by magnetic field instead of photo plethysmography and electrocardiogram. For this purpose, First, we analyzed the correlation between photo plethysmography and magneto plethysmography. the correlation between MPG and PPG was r = 0.9449. Second, we compared estimated blood pressure and measured blood pressure. In the four experiment each result was r = 0.5737, r = 0.7863, r = 0.5669, and r = 0.7445.

Reliability Estimation and Dynamic Deformation of Polymeric Material Using SHPB Technique and Probability Theory (SHPB 기법과 확률이론을 이용한 고분자재료의 동적거동특성 및 건전성 평가)

  • Lee, Ouk-Sub;Kim, Dong-Hyeok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.9
    • /
    • pp.740-753
    • /
    • 2008
  • The conventional Split Hopkinson Pressure Bar (C-SHPB) technique with aluminum pressure bars to achieve a closer impedance match between the pressure bars and the specimen materials such as hot temperature degraded POM (Poly Oxy Methylene) and PP (Poly Propylene) to obtain more distinguishable experimental signals is used to obtain a dynamic behavior of material deformation under a high strain rate loading condition. An experimental modification with Pulse shaper is introduced to reduce the nonequilibrium on the dynamic material response during a short test period to increase the rise time of the incident pulse for two polymeric materials. For the dynamic stress strain curve obtained from SHPB experiment under high strain rate, the Johnson-Cook model is applied as a constitutive equation, and we verify the applicability of this constitutive equation to the probabilistic reliability estimation method. The methodology to estimate the reliability using the probabilistic method such as the FORM and the SORM has been proposed, after compose the limit state function using Johnson-Cook model. It is found that the failure probability estimated by using the SORM is more reliable than those of the FORM, and the failure probability increases with the increase of applied stress. Moreover, it is noted that the parameters of Johnson-Cook model such as A and n, and applied stress affect the failure probability more than the other random variables according to the sensitivity analysis.

Effects of Aromatherapy on Changes in the Autonomic Nervous System, Aortic Pulse Wave Velocity and Aortic Augmentation Index in Patients with Essential Hypertension (아로마 요법이 본태성 고혈압 환자의 자율신경계 변화, 대동맥 맥파 전달속도 및 대동맥 파형증폭에 미치는 효과)

  • Cha, Jung-Hee;Lee, Sun-Hee;Yoo, Yang-Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.5
    • /
    • pp.705-713
    • /
    • 2010
  • Purpose: To investigate the effectiveness of aromatherapy on blood pressure, heart rate variability, aortic pulse wave velocity and the aortic augmentation index of essential hypertensive patients. Methods: Using a coin toss, 22 participants were assigned to the experimental group and 20 to the control. The experimental group was given a blend of oils of lemon (Citrus limonum), lavender (Lavandula angustifolia), and ylang ylang (Cananga odorata) which were prepared in the ratio of 2:2:1, respectively. The control group was given an artificial lemon fragrance of Limonene (35 cc) and Citral (15 cc) mixture. The experiment, inhalation, was conducted for 3 weeks (2 min per inhalation, 2 times per day) to both groups. Results: There was a noticeable difference in systolic blood pressure between the groups (p=.001), however the difference in diastolic blood pressure between the two groups was not significant. There was a notable difference in sympathetic nerve system activity of heart rate variability (p=.047). However, the differences in aortic pulse wave velocity or the aortic augmentation index were not significant. Conclusion: Aromatherapy is effective in lowering systolic blood pressure and sympathetic nerve system activity.

Compensation of the Error Rate for the Non-invasive Sphygmomanometer System Using a Tactile Sensor

  • Jeong, In-Cheol;Choi, Yoo-Nah;Yoon, Hyung-Ro
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.136-141
    • /
    • 2007
  • The Purpose Of This Paper Is To Use A Tactile Sensor To Compensate The Error Rate. Most Automated Sphygmomanometers Use The Oscillometric Method And Characteristic Ratio To Estimate Systolic And Diastolic Blood Pressure. However, Based On The Fact That Maximum Amplitude Of The Oscillometric Waveform And Characteristic Ratio Are Affected By Compliance Of The Aorta And Large Arteries, A Method To Measure The Artery Stiffness By Using A Tactile Sensor Was Chosen In Order To Integrate It With The Sphygmomanometer In The Future Instead Of Using Photoplethysmography. Since Tactile Sensors Have Very Weak Movements, Efforts Were Made To Maintain The Subject's Arm In A Fixed Position, And A 40hz Low Pass Filter Was Used To Eliminate Noise From The Power Source As Well As High Frequency Noise. An Analyzing Program Was Made To Get Time Delay Between The First And Second Peak Of The Averaged Digital Volume Pulse(${\Delta}t_{dvp}$), And The Subject's Height Was Divided By ${\Delta}t_{dvp}$ To Calculate The Stiffness Index Of The Arteries($Si_{dvp}$). Regression Equations Of Systolic And Diastolic Pressure Using $Si_{dvp}$ And Mean Arterial Pressure(Map) Were Computed From The Test Group (60 Subjects) Among A Total Of 121 Subjects(Age: $44.9{\pm}16.5$, Male: Female=40:81) And Were Tested In 61 Subjects To Compensate The Error Rate. Error Rates Considering All Subjects Were Systolic $4.62{\pm}9.39mmhg$, And Diastolic $14.40{\pm}9.62mmhg$, And Those In The Test Set Were $3.48{\pm}9.32mmhg,\;And\;14.34{\pm}9.67mmhg$ Each. Consequently, Error Rates Were Compensated Especially In Diastolic Pressure Using $Si_{dvp}$, Various Slopes From Digital Volume Pulse And Map To Systolic-$1.91{\pm}7.57mmhg$ And Diastolic $0.05{\pm}7.49mmhg$.