• Title/Summary/Keyword: Pulse Pressure

Search Result 1,215, Processing Time 0.031 seconds

A Study on the Performance of Pulse Jet Cleaning in High Temperature Filter (고온 세라믹필터의 펄스젯 탈진 성능에 관한 연구)

  • Kim Byong Ryol;Park Seung Chul;Park Byoung Chul;Cho Hynu Joon;Oh Hyoung Mo;Hwang Tae Won;Shin Sang Woon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.1
    • /
    • pp.9-16
    • /
    • 2005
  • To evaluate parameters influencing on the dust removal of the High Temperature Filter(HTF) system, a computer simulation of fluid dynamics inside the system had been performed. The results showed that the optimum pulse jet periods were 50ms and 90ms for the 1000mm and 1500mm long filter elements respectively. Dust removal effect was very excellent under the pulse jet pressure of 3 bar. But the distance between the pulse jet nozzle and the venturi of a filter element had no meaningful effect on the performance with the variation from 5mm to 10mm. Compared to the dispersion mode of pulse jet, the collective mode of pulse jet flow was preferable in maintaining the pressure inside the system stable.

  • PDF

Optimal Characteristics of a Long-pulse $CO_2$Laser by Controlling SCR Firing Angle in AC Power Line

  • Noh, Ki-Kyung;Kim, Geun-Yong;Chung, Hyun-Ju;Min, Byoung-Dae;Song, Keun-Ju;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.6
    • /
    • pp.304-308
    • /
    • 2002
  • We demonstrate a simple pulsed $CO_2$ laser with millisecond long pulse duration in a tube at a low pressure of less than 30 Torr. The novel power supply for our laser system switches the voltage of the AC power line (60Hz) directly. The power supply doesn't need elements such as a rectifier bridge, energy-storage capacitors, or a current-limiting resistor in the discharge circuit. To control the laser output power, the pulse repetition rate is adjusted up to 60Hz and the firing angle of SCR(Silicon Controlled Rectifier) gate is varied from 30。 to 150。. A ZCS (Zero Crossing Switch) circuit and a PIC one-chip microprocessor are used to control precisely the gate signal of the SCR. The maximum laser output of 35 W is obtained at a total pressure of 18 Torr, a pulse repetition rate of 60 Hz, and a SCR gate firing angle of 90。 . In addition, the resulting laser pulse width is approximately 3㎳(FWHM). This is a relatively long pulse width, compared with other repetitively pulsed $CO_2$ lasers.

Performance Analysis of a Pulse Separation Device for a F-type Multi-Pulse Rocket Motor (F형 다중펄스 로켓모타 적용 펄스분리장치 특성 분석)

  • Lee, Dong-Won;Lee, Won-Bok;Kim, In-Sik;Lee, Bang-Eop
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.24-27
    • /
    • 2012
  • In this study, the full scale flight type Dual-Pulse Rocket Motor(DPRM) with the bulkhead type Pulse Separation Device(PSD) was designed, manufactured, and fire-tested. The bursting time and pressure of PSD were analyzed by the pressure, thrust and vibration results of static fire tests and ablation of PSD was measured with 3-D coordinate measuring machine. As a result, PSD requirements, bursting conditions and thermal safety, were satisfied.

  • PDF

An Experimental Study on the Heat Exchangers in the Pulse Tube Refrigerator (맥동관 냉동기 열교환기에 관한 실험적 연구)

  • 남관우;정상권;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.284-291
    • /
    • 2000
  • A basic pulse tube refrigerator has been constructed with extensive instrumentation to study the characteristics of the heat exchanger experimentally under the oscillating pressure and the oscillating flow. This paper describes the sequential experiments with the basic pulse tube refrigerator. The experiments were performed for various cycle frequencies under the square pressure wave forms. First, the heat flux was measured through the cycle at the both cold and warm end heat exchangers without the regenerator. In order to enhance the thermal communication capability of the heat exchanger with the gas at low operating frequencies, a unique design of the triangular shape radial fin concept was applied to the heat exchangers. For the fin heat exchanger, the measured heat flux and the calculated heat flux from the two well-known oscillating heat transfer correlations were compared and discussed. Second, the regenerator was added to the pulse tube to make a basic pulse tube refrigerator configuration. The experiment showed the great impact of the regenerator on the temperature and the heat flux profiles. At the warm-end, the cyclic averaged heat flux had its maximum value at the specific operating frequency. The paper presents the explanation of the surface heat pumping effect as well as the experimental data.

  • PDF

Characteristics of Disinfection and Removal of 2-MIB Using Pulse UV Lamp (펄스 UV 램프를 이용한 미생물 소독 및 2-MIB 제거 특성)

  • Ahn, Young-Seog;Yang, Dong-Jin;Chae, Seon-Ha;Lim, Jae-Lim;Lee, Kyung-Hyuk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.69-75
    • /
    • 2009
  • The characteristics of disinfection and organic removal were investigated with pulse UV lamp in this study. The intensity and emission wavelength of pulse UV Lamp were compared with low pressure UV lamp. The emission spectrum range of pulse UV lamp was between 200 and 400 nm while the emission spectrum of low pressure UV lamp was only single wavelength of 254nm. 3 Log inactivation rate of B. subtilis spore by pulse UV and low pressure UV irradiation was determined as $44.71mJ/cm^2$ and $57.7mJ/cm^2$, respectively. This results implied that wide range of emission spectrum is more effective compared to single wavelength emission at 254nm. 500ng/L of initial 2-MIB concentration was investigated on the removal efficiency by UV only and $UV/H_2O_2$ process. The removal efficiency of UV only process achieved approximately 80% at $8,600mJ/cm^2$ dose. 2-MIB removal rate of $UV/H_2O_2$ (5 mg/L $H_2O_2$) process was 25 times increased compared to UV only process. DOC removal efficiency for the water treatment plant effluent was examined. The removal efficiency of DOC by UV and $UV/H_2O_2$ was no more than 20%. Removal efficiency of THMFP(Trihalomethane Formation Potential), one of the chlorination disinfection by-products, is determined on the UV irradiation and $UV/H_2O_2$ process. Maximum removal efficiency of THMFP was approximately 23%. This result indicates that more stable chemical structures of NOM(Natural Organic Matter) than low molecule compounds such as 2-MIB, hydrogen peroxide and other pollutants affect low removal efficiency for UV photolysis. Consequently, pulse UV lamp is more efficient compared to low pressure lamp in terms of disinfection due to it's broad wavelength emission of UV. Additional effect of pulse UV is to take place the reactions of both direct photolysis to remove micro organics and disinfection simultaneously. It is also expected that hydrogen peroxide enable to enhance the oxidation efficiency on the pulse UV irradiation due to formation of OH radical.

The Development of pulse Diagnostic Apparatus enable to gain multi-information and it's Clinical Significance (다정보(多情報) 획득(獲得)을 위한 맥진기 개발과 임상적 의의)

  • Park, Y.B.;Lee, H.J.;Huh, W
    • The Journal of Korean Medicine
    • /
    • v.16 no.1 s.29
    • /
    • pp.499-504
    • /
    • 1995
  • Recently, there are deep and much concerns about the objective assessment of diagnosis in Oriental Medicine. Among them, pulse diagnostics is used for the quantitative device of diagnosis. The objective research of pulse diagnosis were mainly conducted by pulse wave. So it is important to gain multi-information for the quantification of pulse diagnosis. We report the development of pulse diagnostic apparatus enable to gain the multi-information, detect the pressure pulse wave in conku(寸口) area and obtain the gradient curve and original pulse wave simultaneously, and consider the pulse wave with the traditional pulse diagnosis at the same time.

  • PDF

Infrared Multiphoton Dissociation of $CHCl_2F$: Reaction Mechanisms and Product Ratio Dependence on Pressure and Laser Pulse Energy

  • Song, Nam-Woong;Lee, Won-Chul;Kim, Hyong-Ha
    • Journal of Photoscience
    • /
    • v.12 no.2
    • /
    • pp.101-107
    • /
    • 2005
  • Infrared multiphoton dissociation of $CHCl_2F$ was studied using $CO_2$ laser excitation. Three products, $C_2Cl_2F_2$, $C_2ClF_3$, and $C_2HClF_2$, were identified by the analysis of the gas mixture from the photoreaction of $CHCl_2F$. The dependence of the reaction probability on added Ar gas pressure and excitation laser pulse energy was investigated. At low pressure (< 10 torr), the reaction probability increased as Ar pressure increased due to the rotational hole-filling effect, while it diminished with the increase of Ar pressure at high pressure (> > 20 torr) due to the collisional deactivation. The ratio of two products $(C_2ClF_3/C_2Cl_2F_2)$ decreased at low pressure (< 10 torr) and increased at high pressure (> 20 torr) with the increase of Ar pressure. The log-log plot of the reaction probability vs. laser pulse energy (${\\phi}$) was found to have a linear relationship, and its slope decreased as the added Ar pressure was increased. The reaction mechanisms for product formation have been suggested and validated by experimental evidences and considering the energetics. Fluorine-chlorine exchange reaction in the intermediate complex has been suggested to explain the formation of $C_2ClF_3$.

  • PDF

A Study on the Changes of Blood Pressure Measurement Factors Before and After Heart Treatment (심장 치료 전후의 혈압 측정 인자의 변화에 관한 연구)

  • Choi, Wonsuk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.51-56
    • /
    • 2021
  • The brachial systolic blood pressure and pulse pressure are the predictors of cardiovascular disease in individuals over 50 years of age. As the stiffness increases, the reflex amplitude and pressure in the late systole increase, resulting in an increase in left ventricular load and myocardial oxygen demand. Therefore, it is necessary to study how stiffness affects blood pressure. In this study, the blood pressure pulse waves were measured before and after taking the drug, and the blood pressure pulse wave was measured before and after myocardial heart transplantation in patients with heart failure. The correlation between R, L, and C components of the Windkessel model was estimated by increasing blood pressure. As a result of modeling the parameters of the Windkessel model using the curve fitting method, the increase in blood pressure and decrease in systolic rise time were due to the increase in the L component in the RLC Windkessel model. Among the various mechanical characteristics of blood vessels, the most important parameter affecting high BP waveform is the inertance.

A Study on the Pulse-mode Thrust Behavior of Liquid-monopropellant Hydrazine Thruster (단일액체추진제 하이드라진 추력기의 펄스모드 추력 거동 연구)

  • Kim Jeong Soo;Park Jeong;Choi Jongwook;Kim Sungcho;Jang Ki Won
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.194-197
    • /
    • 2005
  • Pulse-mode performance evaluation is made for a set of monopropellant hydrazine thrusters producing $0.95 lb_{f}$ of nominal steady-state thrust at an inlet pressure of 350 psia. With a brief description on the hot-firing test matrix, a typical data obtained from pulse-mode firing is given directly showing the variational behavior of propellant supply pressure, vacuum condition, and thrust, in addition to the thermal response of the thruster. The performance features are successfully compared to the reference criteria of 1-lbf standard monopropellant rocket engine.

  • PDF

Development of Blood Pressure Measuring System using piezoelectric and photo sensor (광센서와 압력센서를 이용한 맥박측정시스템 개발)

  • Choi, Young-Suk;Kim, Kyung-Jae;Hong, Woo-Heon;Ryu, Jeong-Tak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.5
    • /
    • pp.149-154
    • /
    • 2009
  • By increasing people's average life span, interest for health is highly growing. According to hoping to check their body condition, people have a medical checkup periodically to check their condition. But, they can prevent disease or are able to make a health care through checking people's pulse or blood pressure. In this paper, two different pulse measurement systems were developed, one system using a photosensor which is able to measure transmissivity's change through blood volume and another system using a piezo-electric sensor which can measure pulse when it measures radial artery's pressure in the wrist are realized. We compared two systems each other.