• 제목/요약/키워드: Pulse Oximeter

검색결과 81건 처리시간 0.026초

Comparative efficacy of three topical anesthetics on 7-11-year-old children: a randomized clinical study

  • Dasarraju, Rupak Kumar;SVSG, Nirmala
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권1호
    • /
    • pp.29-37
    • /
    • 2020
  • Background: This study evaluated the efficacy of three intraoral topical anesthetics in reducing the injection needle prick pain from local anesthetic among children aged 7-11 years old. Methods: It is a prospective, Interventional, parallel design, single-blind, randomized clinical trial in which subjects (n=90) aged 7-11 years were included in the study based on an inclusion criteria. Subjects were divided into three groups based on computer-generated randomization with an allocation ratio of 1:1:1. Groups A, B, and C received benzocaine 20% jelly (Mucopain gel, ICPA health products Ltd, Ankleshwar, India), cetacaine anesthetic liquid (Cetylite Industries, Inc, Pennsauken, NJ), and EMLA cream (2% AstraZeneca UK Ltd, Luton, UK), respectively, according to manufacturer's instructions, for 1 minute prior to local anesthetic injection. After application of topical anesthetic agent, for all the groups, baseline pre-operative (prior to topical anesthetic administration) and post-operative scores (after local anesthetic administration) of pulse rate was recorded using Pulse oximeter (Gibson, Fingertip Pulse Oximeter, MD300C29, Beijing Choice Electronic). Peri-operative (i.e., during the administration of local anesthesia) scores were recorded using Face, Legs, Activity, Cry, Consolability (FLACC) Scale, Modified Children hospital of Eastern Ontario Pain Scale (CPS) behavior rating scale, and Faces Pain Scale (FPS-R) - Revised (For self-reported pain). Direct self-reported and physiological measures were ascertained using FPS-R - Revised and Pulse oximeter, respectively, whereas CPS and FLACC scales assessed behavioral measures. To test the mean difference between the three groups, a one way ANOVA with post hoc tests was used. For statistical significance, a two-tailed probability value of P < 0.05 was considered as significant. Results: The Cetacaine group had significantly lower pain scores for self-report (P < 0.001), behavioral, and physiological measures (P < 0.001) than the other two groups. However, there was no significant difference between the Benzocaine group and EMLA group during palatal injection prick. Conclusion: Cetacaine can be considered as an effective topical anesthetic agent compared to benzocaine 20% jelly (Mucopain gel) and EMLA cream.

소아 치과치료시 심박동과 동맥혈 산소포화도의 변화 (PULSE RATE AND OXYGEN SATURATION IN CHILDREN DURING ROUTINE RESTORATIVE DENTISTRY)

  • 김하나;백병주;김재곤;양연미;박정렬
    • 대한소아치과학회지
    • /
    • 제35권1호
    • /
    • pp.65-72
    • /
    • 2008
  • 소아환자의 진정법시 사용되는 환자감시 기구 중 하나인 pulse oximeter는 산소포화도를 감시하여 조기에 저산소혈증을 발견하는데 유용하게 이용된다. 이 연구의 목적은 진정법을 시행하지 않은 소아환자에서 pulse oximeter(pulse oximeter7845, Kontron Instrument Ltd., England)를 이용하여 일상적인 수복치료시 치료단계에 따른 심박동과 동맥혈 산소포화도의 양상이 어떻게 나타나는지 알아보고자 한다. 전북대학교병원 소아치과에 내원한 53명의 어린이를 대상으로 치료전 3분과 치료후 3분을 포함하여 수복치료 단계별로 심박동과 동맥혈 산소포화도가 기록되었고, 기록된 수치를 바탕으로 다음의 결과를 얻었다. 1. 비마취군에서 상, 하악 치료군 간 심박동 변화를 비교시 상악의 경우 러버댐 장착시 심박동이 급격히 증가한데 비해 하악치료군에서는 와동 형성시 심박동이 크게 증가하였다. 2. 마취군에서 상, 하악 심박동 변화를 비교시 상악치료군에서는 러버댐 장착을 기점으로 심박동이 감소되는 양상을 보인 반면, 하악 치료군은 와동형성시점부터 심박동이 감소되었다. 3. 비마취군에서 상, 하악 치료군 간 동맥혈 산소포화도를 비교하였을 때 상악 치료군은 치료 전부터 치료 후까지 비교적 일정한 값을 나타내며 모든 단계에서 하악보다 약간 높은 값을 보인 반면, 하악 치료군은 러버댐 장착시 증가하여 유지되다가 치료 후 다시 치료 전 수준과 유사하게 감소하는 양상을 보였다. 4. 마취군에서는 모든 단계에서 동맥혈 산소포화도 값이 99% 수준에 머물고 있으며, 상악과 하악 치료군 사이에 유의한 차이는 존재하지 않았다(p>0.05).

  • PDF

펄스옥시미터 시스템의 광조절 알고리즘 구성 방법 (A Light Control Algorithm for Pulse Oximeter)

  • 강민수;이정환
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2012년도 제46차 하계학술발표논문집 20권2호
    • /
    • pp.229-231
    • /
    • 2012
  • 본 논문에서는 펄스옥시미터 시스템의 측정 신뢰성 향상을 위해 Perfusion Index값을 이용한 광량조절의 방법을 제시한다. 본 방법은 펄스옥시미터의 광출력 값의 조정을 미약한 신호 상황에 대한 적응 가능한 광출력을 줄 수 있으며, 산소포화도 측정값의 변화율에 직접적으로 영향을 주는 광량을 보다 정확하게 조절하여 안정적인 측정이 가능하다. 또한 미약한 신호의 측정을 일괄적으로 조절 가능한 기능을 통해 다양한 사람들에게 사용되는 펄스옥시미터의 특성상 보다 정확한 값을 제공할 수 있다.

  • PDF

반사형 Pulse Oximeter를 통한 스마트 손목시계 (Smart watch with reflective Pulse Oximeter)

  • 이후석;탑타른;문찬기;남윤영;이진석
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2015년도 춘계학술발표대회
    • /
    • pp.1046-1048
    • /
    • 2015
  • 본 논문은 웨어러블 디바이스의 한 종류로써의 스마트와치에 적용할 수 있는 헬스케어 기술에 대한 제안이다. RED LED와 IR LED를 통해 얻어진 신호로부터 아날로그 필터 증폭을 통해 얻어진 PPG신호를 이용하여 생체신호인 심박수와 $SpO_2$를 측정하여 보았다. 이 신호를 블루투스 통신을 통해 PC에서 데이터를 받아 보았고, 추후에 스마트폰과 연동하여 실용적으로 사용 될 수 있다.

On a Reading Aloud to Relieve the Decrease in Blood Oxygen Saturation when Jogging

  • Tian, Zhixing;Bae, MyungJin
    • International Journal of Advanced Culture Technology
    • /
    • 제8권4호
    • /
    • pp.95-100
    • /
    • 2020
  • Recently, the problem of hypoxia caused by jogging is attracting attention. To solve this problem, this paper proposed a new solution. This paper proved that as a vocalization method of reading aloud, it is possible to increase air intake and activate lung function to exchange more air and obtain more oxygen. Then, blood oxygen saturation was used as an evaluation index for the body's oxygen content level to prove its effectiveness. A photoelectric pulse oximeter developed on the basis of different light absorption principles in blood was used to test blood oxygen saturation. Experimental results show that a certain degree of hypoxia is induced when a lot of oxygen is required due to jogging. Therefore, it was proved that the new vocal breathing method by reading books can increase the blood oxygen saturation of the body and improve the hypoxia of the body. Reading vocal breathing is a simple and efficient oxygen saturation recovery breathing method.

u-Health 서비스 지원을 위한 착용형 옥시미터를 이용한 맥파 분석 시스템 (Pulse wave analysis system using wrist type oximeter for u-Health service)

  • 정상중;서용수;정완영
    • 센서학회지
    • /
    • 제19권1호
    • /
    • pp.17-24
    • /
    • 2010
  • This paper describes a real time reliable monitoring method and analysis system using wrist type oximeter for ubiquitous healthcare service based on IEEE 802.15.4 standard. Photoplethysmograph(PPG) is simple and cost effective technique to measure blood volume change. In order to obtain and monitor physiological body signals continuously, a small size and low power consumption wrist type oximeter is designed for the measurement of oxygen saturation of a patient unobtrusively. The measured data is transferred to a central PC or server computer by using wireless sensor nodes in wireless sensor network for storage and analysis purposes. LabVIEW server program is designed to monitor stress indicator from heart rate variability(HRV) and process the measured PPG to accelerated plethysmograph(APG) by appling second order derivatives in server PC. These experimental results demonstrate that APG can precisely describe the features of an individual's PPG and be used as estimation of vascular elasticity for blood circulation.

소아 환자의 치수 혈류 평가를 위한 광용적맥파 파형 분석 (Analysis of Photoplethysmographic Waveform for Assessment of Pulpal Blood Flow in Children)

  • 김효은;신터전;공현중;김필종;현홍근;김영재;김정욱;장기택;김종철;이상훈
    • 대한소아치과학회지
    • /
    • 제43권2호
    • /
    • pp.158-165
    • /
    • 2016
  • 본 연구는 맥박산소측정기를 이용하여 광용적맥파 파형의 원데이터를 기록하고 분석함으로써 치수 생활력 측정에 이 원데이터 분석의 적용가능성을 살펴보고 정상 치수 생활력을 갖는 소아환자의 상악 중절치에 대한 광용적맥파 파형의 파라미터에 대한 기초 자료를 마련할 목적으로 시행되었다. 상악 중절치에 대해 정상 치수 생활력을 갖고 전신질환이 없는 30명의 환아(남 16명, 여 14명, 평균연령 11.4세)를 연구대상으로 선정하였다. 맞춤형 센서와 맥박산소측정기를 이용하여 측정하였으며 측정결과는 적색 파장과 적외선 파장의 원데이터 형태로 기록되었고 LabChart(v.7.3, ADInstruments, Germany)를 이용하여 분석하였다. 본 연구를 통해 소아에서 정상 치수생활력을 갖는 상악 중절치에 대한 광용적맥파 파형의 파라미터의 기준값을 제시할 수 있었으며 소아의 치수혈류측정에 이러한 광용적맥파 파형 분석이 활용될 수 있음을 확인하였다.

독립 성분 분석과 비선형 자기상관을 이용한 동잡음이 포함된 PPG 신호에서의 맥박 검출 (Pulse Detection from PPG Signal with Motion Artifact using Independent Component Analysis and Nonlinear Auto-correlation)

  • 전학재;김정도;임승주
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.71-78
    • /
    • 2016
  • PPG signal measured by pulse oximeter can measure pulse and the oxygen saturation of arterial blood. But the PPG signal is distorted by finger movement or other movement in the body. To detect pulse from the PPG signal with motion artifact, we use band pass filter(BPF), Independent component analysis(ICA) and nonlinear autocorrelation(NAC). BPF is used to remove DC component and high frequency noise in the PPG signal with motion artifacts. ICA is used to separate pulse signal and motion artifact. However, pulse signal separated by ICA have no choice but to accompany signal distortion because pulse signal and motion artifact are not completely independent. So, we use nonlinear autocorrelation to emphasize the pure pulse signal from the distorted signal.

동잡음을 가진 PPG 센서에서의 산소포화도 측정 알고리즘 (SpO2 Measurement Algorithm for PPG Signal with Motion Artifacts)

  • 장성진;최규락;박근혜;김정도
    • 센서학회지
    • /
    • 제27권3호
    • /
    • pp.192-198
    • /
    • 2018
  • Pulse oximetry is a non-invasive method for monitoring how much oxygenated hemoglobin is present in the blood. The principle of pulse oximetry is based on the red infrared light adsorption characteristics of oxygenated and deoxygenated hemoglobin. Even through the convenience of a pulse oximeter, its weak signal-to-noise ratio against motion artifacts and low perfusion makes it difficult to be accepted by execs devices. Several researchers have suggested the use of an adaptive noise cancellation (ANC) algorithm. They have demonstrated that ANC is feasible for reducing the effects of motion artifacts. Masimo Corporation developed a discrete saturation transformation (DST) algorithm that uses a reference signal and ANC. In commercial devices, it is very hard to escape it because Masimo's patents are very powerful and a better method is yet to be developed. This study proposes a new method that can measure noise saturation as well as accurate oxygen saturation from signals with high motion artifacts without using ANC and DST. The proposed algorithm can extract a normal signal without noise from a signal with motion artifacts. The reference signal from a pulse oximeter simulator was used for the evaluation of our proposed algorithm and achieved good results.

컴팩트 플래쉬 방식의 휴대용 산소포화도 측정 시스템 구현 (Implementation of a portable pulse oximeter for SpO2 using Compact Flash Interface)

  • 이한;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 춘계종합학술대회
    • /
    • pp.678-681
    • /
    • 2003
  • 컴팩트 플래쉬방식의 휴대용산소포화도와 ECG감시 시스템을 구현하는데 목적이 있다. 먼저 휴대용 산소포화도의 측정은 산소포화도와 맥박을 동시에 측정해서 2채널을 기록하도록 설계했다. 다른 장치없이 환자의 상태를 감지할 수 있고 소형화되고 휴대 가능하게 했다. 환자모니터링에 의해 발생하는 문제점을 해결하기 위해 기저선변동을 없애기 위해 2D 섹터 알고리즘을 적용시킨 아날로그 보정회로를 추가했다. 현재 SpO2모듈은 완성됐지만 컴팩트 플래쉬 방식을 사용하는데는 아직까지 많은 개선의 여지가 있다. ECG감시장치는 3극자 ECG시스템을 적용했다. 필터로는 2가지가 혼합된 방식이다. 하나는 전력선을 없애는 것이고 다른 하나는 기저선 변동을 없애는 것이다. 이것은 DC간섭을 줄이고 전력선의 주파수 간섭을 없애는 효과가 있다. 컴팩트플래쉬 방식으로 환자의 정보를 적은 비용으로 쉽게 기록하고 의료기관에 알릴수 있다.

  • PDF