• Title/Summary/Keyword: Pulse Method

Search Result 3,146, Processing Time 0.035 seconds

Pulse Diagnosis Algorithm and Digital Filter Design for Development of Digital Biomedical System (전자 맥진기 시스템 개발을 위한 맥파분석 알고리즘과 디지털 필터 설계)

  • Kim, Sang-Ho;Lim, Duk-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4473-4482
    • /
    • 2010
  • The examination of pulse, which is a typical palpation technique in the oriental medicine, has been used conventional analog system for discrimination of 28 pulses. However, the clipping phenomenon in the pulses, which used same feature extraction technique with ECG signals, has been occurred in analog system due to feature extraction method and over amplification from the input signals. It caused inaccurate to analyze the pulse signals. In this paper, we propose a digital filter design technique based on Prony's method for signal modeling and C-spline interpolation for feature extraction from pulse signal to compensate analog pulse detection system. In addition, we suggest a compensated electronic pulse detection system comprising new pulse analyzing algorithm and shape analysis technique for pulses, which were difficult to use in analog system. The feasibility for new proposed system has been confirmed comparing output signals between electronic pulse detection system having proposed filter design techniques with pulse analyzing algorithm and conventional analog system.

Enhanced Pulse Amplitude Estimation Method for Electronic Warfare Support (전자전 지원을 위한 향상된 펄스 세기 추정 기법)

  • Lee, Yu-Ri;Kim, Dong-Gyu;Kwak, Hyungyu;Kim, Hyoung-Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.3
    • /
    • pp.649-660
    • /
    • 2017
  • In electronic warfare, the pulse amplitude, one of information of a pulse signal emitted by an enemy, is used for estimating distance from the source and for deinterleaving mixed source signals. An estimate of pulse amplitude is conventionally determined as the maximum magnitude of a Fourier transformed signal within its pulse width which is estimated pre-step in an electronic warfare receiver. However, when frequency modulated signals are received, it is difficult to estimate their pulse amplitudes with this conventional method because the energy of signals is dispersed in frequency domain. In order to overcome this limitation, this paper proposes an enhanced pulse amplitude estimation method which calculates the average power of the received pulse signal in time domain and removes the noise power of the receiver. Simulation results show that even in case the frequency modulated signal is received, the proposed method has the same performance as estimating the pulse amplitude when unmodulated signal is received. In addition, the proposed method is shown to be more robust to an estimation error of pulse width, which affects the estimation performance of pulse amplitude, than the conventional method.

Delphi Study for Developing Consensus of Physical Attribute in Pressure Pulse Waveform (맥상파 물리량 속성 총의형성을 위한 델파이 연구)

  • Lee, Haebeom;Kim, Hyunho;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.18 no.3
    • /
    • pp.137-148
    • /
    • 2014
  • Objectives This study was conducted to derive consensus about physical attributes in pressure pulse waveform and pulse conditions by Delphi study. Methods Delphi research was conducted for 2 rounds via e-mail. 8 Professors who lecture on a diagnostics of K. M. from the society of Korean medicine diagnostics were participated in this survey. They were asked for answering about series of definition for a physical attribute in pressure pulse waveform and combination for physical attributes of pulse conditions. Results 4 survey items were decided to have high validity and 9 survey items were decided to come to consensus about a physical attribute in pressure pulse waveform. 6 pulse condition were decided to come to consensus. Conclusion Using Delphi method, physical attributes in pressure pulse waveform and combinations of physical attribute in pulse condition come to consensus.

Study of Discussion for Pulse Diagnosis of Meridian System seen by Research Assignment of the Small and Large Intestine in Wrist Pulse-taking Method (寸口脈의 小腸, 大腸 配屬 論議로 바라본 脈診의 經絡診斷 연구)

  • Hwang, Chi Hyuk;Kim, Myung Hyun;Kim, Byoung Soo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.29 no.3
    • /
    • pp.240-245
    • /
    • 2015
  • Pulse diagnosis, the most popular diagnostic tool in traditional Korean medicine, had had many forms but had been fixed on using wrist pulse and placing internal organs on Cun, Guan and Chi(寸 關 尺). Wang Shuhe(王叔和) suggested placing six viscera(六腑) on Cun, Guan and Chi based on relationship between external and internal meridian vessel, and Zhang Jiebin(張介賓) criticized his suggestion and insisted that pulse diagnosis should be based on the organ system. But the origin of pulse diagnosis which can be found in "(Huangdi's) Internal Classic(黃帝內經)" is a tool mainly for diagnosis of not internal organ system but meridian system. Most of material about pulse diagnosis after Ming dynasty(明代) reinterpreted pulse diagnosis in the aspect of organ system, So there has to be additional discussion about it.

Evaluation of pulse effect on frequency content of ground motions and definition of a new characteristic period

  • Yaghmaei-Sabegh, Saman
    • Earthquakes and Structures
    • /
    • v.20 no.4
    • /
    • pp.457-471
    • /
    • 2021
  • This study aims at providing a simple and effective methodology to define a meaningful characteristic period for special class of earthquake records named "pulse-like ground motions". In the proposed method, continuous wavelet transform is employed to extract the large pulse of ground motions. Then, Fourier amplitude spectra obtained from the original ground motion and the residual motion is simply compared. This comparison permits to define a threshold pulse-period (Tp∗) as the threshold period above which the pulse component has negligible contributions to the Fourier amplitude spectrum. The effect of pulse on frequency content of motions was discussed on the light of this definition. The advantage and superior features of the new definition were related to the inelastic displacement ratio (IDR) for single-degree-of-freedom systems with period equal to one half of the threshold period. Analyses performed for the proposed period at three ductility levels u=2,4,6 were compared with the results obtained at half of pulse period derived from wavelet analysis, peak-point method and the peak of product of the velocity and the displacement response spectra (Sv x Sd). According to the results, pulse effects on inelastic displacement ratio seem to be more important when $\frac{T_p^*}{T}=2$ (T is the fundamental vibration period of system). The results showed that utilizing of the proposed definition could facilitate an enhanced understanding of pulse-like records features.

New Algorithm of Determining the Floating and Sinking Pulse with a Pulse Diagnosis Instrument (맥진기를 이용한 새로운 부침맥 판단 방법)

  • Kim, Sung-Hun;Kim, Jae-Uk;Lee, Yu-Jung;Kim, Keun-Ho;Kim, Jong-Yoel
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.6
    • /
    • pp.1221-1225
    • /
    • 2009
  • The pulse diagnosis is an important and universally used method in Oriental Medicine. Since the traditional method of palpating the pulse relies on the subjective sense in the fingers of an Oriental Medical Doctor(OMD), there has been continued need for more objective method for pulse diagnosis. Recently, various pulse analyzers have been developed to meet such objective palpation and interpretation. However, most of these attempts were not successful to replace OMD's own palpation by fingers. To improve the performance of the pulse analyzers, one should develop machine-appropriate interpretations for the pulse images in the literature, in addition to the improvement in the repeatability and reproducibility. One of such widely-used pulse images to be interpreted is the floating and sinking pulse. The floating and sinking pulses are the two representative pulse images informing us how strong pressure one should apply to obtain the maximal pulse strength. A previous study suggested a convenient and unified measure for the floating and sinking pulses by defining the coefficient of the floating-sinking pulse(CFS). We found the original definition of the CFS could be erroneous under some situations. To improve the performance, we introduce new CFS algorithm for determining the floating and sinking pulse with a pulse analyzers(3-D MAC). To test the performance of the newly suggested algorithm, we conducted a clinical study comparing the agreement ratio with the floating and sinking pulse diagnosis by the OMDs. We found that, among the subjects who are diagnosed with having either the floating pulse or sinking pulse, the new CFS algorithm showed 55.3% diagnosis rate and 73.0% concordance rate, which are about 3% and 6% improvement in the diagnosis rate and agreement rate, respectively, compared to the original CFS algorithm.

Performance Analysis of Pulse Positioning Using Adaptive Threshold Detector (ATD)

  • Chang, Jae Won;Lee, Sang Jeong
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.7 no.1
    • /
    • pp.25-35
    • /
    • 2018
  • This paper describes the measurement of pulse positioning (input time) to calculate a time of arrival (TOA) that takes from transmitting a signal from the target of multilateration (MLAT) system to receiving the signal at the receiver. In this regard, this paper analyzes performances of simple threshold method and level adjust system (LAS) method, which is one of the adaptive threshold detector (ATD) methods, among many methods to calculate pulse positioning of signal received at the receiver. To this end, Cramer-rao lower bound (CRLB) with regard to pulse positioning, which was measured when signals transmitted from a transponder mounted at the target were received at the receiver, was induced and then deviation sizes with regard to pulse positioning, which was measured with simple threshold and LAS methods through MATLAB simulations, were compared. Next, problems occurring according to a difference in amplitude of signals inputted to each receiver are described when pulse positioning is measured at multiple receivers located at a different distance from the target as is the case in the MLAT system. Furthermore, LAS method to resolve the problems is explained. Lastly, this study analyzes whether a pulse positioning error occurring due to the signal noise satisfies the requirement (6 nsec. or lower) recommended for the MLAT system when using these two methods.

A Study on the Recognition of Human Pulse Using Wavelet Transform (웨이브렛 변환을 이용한 맥파의 인식에 관한 연구)

  • 길세기;김낙환;박승환;민홍기;흥승홍
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.08a
    • /
    • pp.269-272
    • /
    • 2000
  • It is need to develop and apply a human pulse diagnosis system providing a quantitative and automatic analysis in the the oriental medicine. In order to analyze quantitatively the characteristic of pulsation, each of points had to be recognized accurately notifying the existence and the position of feature point in the wave form. And getting the period of human pulse. Thus, in this paper, it is proposed the preprocessing method of human pulse and the detection method of period by Wavelet Transformation. The human pulse is seprated from each band through Wavelet Transformation and feature points can be recognized through over the fact, and then the parameter of proposed Mac-Jin parameter is measured. Commonly, Human pulse signal has often various noises which are baseline drift, high frequency noise and so on. So it is significant to remove that noises. Thus, in this paper, the one period of human pulse is deciede and the feature points are detected after doing the preprocessing by wavelet transformation. As a result, it could be confirmed that this method is effective as a real program for the auto-diagnosis of human pulse.

  • PDF

A Study of Applicability of PDT(Pulse Discharge Technology) Pile to Kyung-Geon Rail Road and the bedding Construction of a new port in Busan (경전선 복선전철 및 부산신항 노반건설공사 중 PDT말뚝 적용성 연구)

  • Hur, Eok-Jun;Park, Jae-Myung;Yun, Su-Dong;Kim, Tae-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1203-1208
    • /
    • 2007
  • In the past decades, complain about ground vibration and noise induced by pile driving has been quickly increased. Because of that, auger drilled piling methods have frequently used specially in urban area. However, the present auger drilled piling methods induce inevitable ground disturbance as well as a certain degree of vibration and noise due to the final hammering. For these reasons, a new auger drilled piling method is required to be developed. This paper introduces PDT(Pulse Discharge Technology) piling method and presents the characteristics of bearing capacity. The PDT piling method is to install in-situ piles using electric power so called Pulse. The pile installed by PDT appears to be able to develop shaft and end bearing capacity efficiently. This paper introduces PDT(Pulse Discharge Technology) piling method, which is the 512nd new construction technology. The PDT piling method is to install in-situ piles using electrical power so called Pulse power. The pulse power is physical value that indicates the energy change per unit time(dE/dt). Since the pulse power is to push ground, using the pulse power is enable a hole to be expanded as well as the ground to be improved by compaction. Therefore, The pile installed by PDT appears to be able to develop shaft and end bearing capacity efficiently. In this study, couples of pile loading tests were carried out to figure out whether or not the PDT piling method is applicable to constructions like rail road facility. As a result, it was concluded that the PDT piling technique meet the requirements for such a rail road related construction.

  • PDF

Error Analysis of Reaction Wheel Speed Detection Methods Due to Non-uniformity of Tacho Pulse Duration (타코 펄스 불균일성이 존재하는 반작용휠의 속도측정 방법 오차 분석)

  • Oh, Shi-Hwan;Yong, Ki-Lyuk
    • Aerospace Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.92-97
    • /
    • 2009
  • Two conventional speed detection methods (Elapsed-time method and Pulse-count method) are analyzed and compared for a high speed motor with digital tacho pulse with non-uniformity. In general, the elapsed-time method usually has better performance than a pulse-count method in case sufficiently high speed clock is used to measure the time difference. But if a tacho pulse non-uniformity exists in the reaction wheel - most of reaction wheel has a certain amount of non-uniformity - the accuracy of the elapsed-time method is degraded significantly. Thus the performance degradation is analyzed with respect to the level of non-uniformity of tacho pulse distribution and an allowable bound is suggested.

  • PDF