Study on Filter Drag Due to the Change of Operation Conditions in a Pulse Air Jet-type Bag Filter[I] (충격기류식 여과집진장치에서 운전조건 변화로 인한 여과저항에 관한 연구[I])

  • Ryu, Jae-Yong;Suh, Jeong-Min;Park, Jeong-Ho;Jeon, Bo-Kyung;Choi, Kum-Chan;Son, Yoyng-Il
    • Journal of Environmental Science International
    • /
    • v.16 no.4
    • /
    • pp.449-458
    • /
    • 2007
  • Research results for the pressure drop variance depending on operation conditions such as change of inlet concentration, pulse interval, and face velocity, etc., in a pulse air jet-type bag filter show that while at $3kg/cm^2$ whose pulse pressure is low, it is good to make an pulse interval longer in order to form the first layer, it may not be applicable to industry because of a rapid increase in pressure. In addition, the change of inlet concentration contributes more to the increase of pressure drop than the pulse interval does. In order to reduce operation costs by minimizing filter drag of a filter bag at pulse pressure $5kg/cm^2$, the dust concentration should be minimized, and when the inlet dust loading is a lower concentration, the pulse interval in the operation should be less than 70 sec, but when inlet dust loading is a higher concentration, the pulse interval should be below 30 sec. In particular, in the case that inlet dust loading is a higher concentration, a high-pressure distribution is observed regardless of pulse pressure. This is because dust is accumulated continuously in the filter bag and makes it thicker as filtration time increases, and thus the pulse interval should be set to below 30 sec. If the equipment is operated at 1m/min of face velocity, while pressure drop is low, the bag filter becomes larger and thus, its economics are very low due to a large initial investment. Therefore, a face velocity of around 1.5 m/min is considered to be the optimal operation condition. At 1.5 m/min considered to be the most economical face velocity, if the pulse interval increases, since the amount of variation in filter drag is large, depending on the amount of inlet dust loading, the operation may be possible at a lower concentration when the pulse interval is 70 sec. However, for a higher concentration, either face velocity or pulse interval should be reduced.

Tracking of Radar Pulse Train Using Kalman Filter (칼만 필터를 사용한 레이더 펄스열 추적)

  • 김용우;신욱현;이효섭;김홍필;양해원
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.176-176
    • /
    • 2000
  • Generally, discrete-time processing is applied to the uniformly-sampled signals. But, radars emit pulse trains with irregular time instances. In this paper, we formulate the radar pulse train as a stochastic discrete-time dynamic linear model. The estimation task can be done via linear signal processing using Kalman Filter and some considerations. As a result, we can estimate the pulse repetition interval of a pulse train and predict the time instances of the next pulses to be received.

  • PDF

Direct blast detection algorithm for asynchronous bistatic sonar systems (비동기 양상태 소나 시스템을 위한 직접파 탐지 기법)

  • Jeong, Euicheol;Ahn, Jae-Kyun;Kim, Juho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.3
    • /
    • pp.139-146
    • /
    • 2018
  • Monostatic sonar systems localize targets using the time information of pulse transmission and receipt. Whereas, in asynchronous bistatic sonar systems, receivers need to detect direct blast to localize targets, since a source doesn't share pulse information with receivers. In this paper, we propose a direct blast detection algorithm, which estimates PRI (Pulse Repetition Interval) of direct blast and adaptive thresholds. Experimental results show the proposed algorithm has robust direct blast detection performance in the environment where strong background noise and target signal exist.

Estimation of baroreflex sensitivity using pulse arrival time rather than systolic blood pressure measurement

  • Lee, Jong-Shill;Chee, Young-Joon
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.1
    • /
    • pp.14-19
    • /
    • 2010
  • Baroreflex sensitivity (BRS) is a parameter of the cardiovascular system that is reflected in changes in pulse interval (PD and systolic blood pressure (SBP). BRS contains information about how the autonomic nervous system regulates hemodynamic homeostasis. Normally the beat-to-beat SBP measurement and the pulse interval measured from the electrocardiogram (ECG) are required to estimate the BRS. We investigated the possibility of measuring BRS in the absence of a beat-to-beat SBP measurement device. Pulse arrival time (PAT), defined as the time between the R-peak of the ECG and a single characteristic point on the pulse wave recorded from any arterial location was measured by photoplethysmography. By comparing the BRS obtained from conventional measurements with our method during controlled breathing, we confirmed again that PAT and SBP are closely correlated, with a correlation coefficient of -0.82 to -0.95. The coherence between SBP and PI at a respiration frequency of 0.07-0.12 Hz was similar to the coherence between PAT and PI. Although the ranges and units of measurement are different (ms/mmHg vs. ms/ms) for BRS measured conventionally and by our method, the correlation is very strong. Following further investigation under various conditions, BRS can be reliably estimated without the inconvenient and expensive beat-to-beat SBP measurement.

The Properties of Na-Ca Exchange Current in Single Atrial Cells of ,The Rabbit (토끼 단일 심방근 세포에서 Na-Ca 교환전류의 특성에 관한 연구)

  • Youm, Wook;Ho, Won-Kyung;Suh, Kyung-Phill
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.548-561
    • /
    • 1989
  • In single atrial cells isolated from the rabbit the properties of inward current of Na-Ca exchange were investigated using the whole cell voltage clamp technique. The current was recorded during repolarization following brief 2 ms depolarizing pulse to +40 mV from a holding potential of * 70 mV. Followings are the results obtained: 1. When stimulated every 30 seconds, the inward currents were activated and reached peak values 6-12 ms after the beginning of depolarizing pulse. The mean current amplitude was 342 pA/cell. 2. The current decayed spontaneously from the peak activation and the time course of the relaxation showed two different phases fast and slow phase. The time constants were 10-18 ms and 60-140 ms, respectively. 3. The recovery of inward current was tested by paired pulse of various intervals. The peak current recovered exponentially with time constant of 140 ms and 1 p M isoprenaline accelerated the recovery process. 4. Relaxation time course was also affected by pulse interval and time constant of the fast phase was reduced almost linearly according to the decrease of pulse interval between 30 sec and 1 sec. 5. The peak activation was increased in magnitude by long prepulse stimulation, 5 p M Bay K, 1 p M isoprenaline or internal and external application of c-AMP. 6. The relaxation time constant of the fast phase was prolonged by 5 p M Bay K or c-AMP, and shortened by isoprenaline. However the time course of the slow relaxation phase was not so much changed. From the above results, it could be concluded that increase of the calcium current by Bay K or c-AMP results in the potentiation and prolongation of intracellular calcium transient, and the facilitation of Ca uptake by SR might be a mechanism of shortening the time constant of current relaxation by short interval stimulation or isoprenaline.

  • PDF

The Prediction of Optimal Pulse Pressure Drop by Empirical Static Model in a Pulsejet Bag Filter (경험모델을 이용한 충격기류식 여과집진기의 적정 탈진압력 예측)

  • Suh, Jeong-Min;Park, Jeong-Ho;Lim, Woo-Taik;Kang, Jum-Soon;Cho, Jae-Hwan
    • Journal of Environmental Science International
    • /
    • v.21 no.5
    • /
    • pp.613-622
    • /
    • 2012
  • A pilot-scale pulse-jet bagfilter was designed, built and tested for the effects of four operating conditions (filtration velocity, inlet dust concentration, pulse pressure, and pulse interval time) on the total system pressure drop, using coke dust from a steel mill factory. Two models were used to predict the total pressure drop according to the operating conditions. These model parameters were estimated from the 180 experimental data points. The empirical model (EM) with filtration velocity, areal density, inlet dust concentration, pulse interval time and pulse pressure shows the best correlation coefficient (R=0.971) between experimental data and model predictions. The empirical model was used as it showed higher correlation coefficient (R=0.971) compared to that of the Multivariate linear regression(MLR) (R=0.961). The minimum pulse pressure predicted by empirical model (EM) was 5kg/$cm^2$.

A Detection Algorithm for Pulse Repetition Interval Sequence of Radar Signals based on Finite State Machine (유한 상태 머신 기반 레이더 신호의 펄스 반복 주기 검출 알고리즘)

  • Park, Sang-Hwan;Ju, Young-Kwan;Kim, Kwan-Tae;Jeon, Joongnam
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.85-91
    • /
    • 2016
  • Typically, radar systems change the pulse repetition interval of their modulated signal in order to avoid detection. On the other hand the radar-signal detection system tries to detect the modulation pattern. The histogram or auto-correlation methods are usually used to detect the PRI pattern of the radar signal. However these methods tend to lost the sequence information of the PRI pulses. This paper proposes a PRI-sequence detection algorithm based on the finite-state machine that could detect not only the PRI pattern but also their sequence.

Effects of Bay K, cAMP and Isoprenaline on the Na-Ca Exchange Current of Single Rabbit Atrial Cells (토끼 심방근에서 Na-Ca 교환 전류에 대한 Bay K, cAMP, Isoprenaline 효과)

  • Ho, Won-Kyung;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.24 no.2
    • /
    • pp.377-388
    • /
    • 1990
  • Ca movements during the late plateau phase in rabbit atrium implicate Na-Ca exchange. In single atrial cells isolated from the rabbit the properties of the inward current of Na-Ca exchange were investigated using the whole cell voltage clamp technique. The inward currents were recorded during repolarization following brief 2 ms depolarizing pulse to +40 mV from a holding potential of -70 mV. Followings are the results obtained: 1) When stimulated every 30 sec, the inward currents were activated and reached peak values $6{\sim}12\;ms$ after the beginning of depolarizing pulse. The mean current amplitude was 342 pA/cell. 2) The current decayed spontaneously from the peak activation and the timecourse of the relaxation showed two different phases: fast and slow phase. 3) The recovery of the inward current was tested by paired pulse of various interval. The peak current recovered exponentialy with a time course similar to that of Ca current recovery. 4) Relaxation timecourse was also affected by pulse interval and time constant was reduced almost linearly according to the decrease of pulse interval between 30 sec and 1 sec. 5) The peak inward current was increased by long prepulse stimulation, Bay K, isoprenaline or c-AMP. 6) The relaxation time constant of the inward current was prolonged by Bay K or c-AMP, and shortened by isoprenaline. From the above results, it could be concluded that increase of the calcium current potentiates and prolongs intracellular calcium transients, while shortening of the timecourse by isoprenaline or short interval stimulations might be due to the facilitation of Ca uptake by SR.

  • PDF

Characteristics of the Electromagnetic Fields Radiated from Stepped Leaders Just Prior to Lightning Return Strokes (계단상 리더에 의해서 방사된 귀환뇌격 직전의 전장과 자장 파형의 특성)

  • 이복희;이동문;정동철;장근철;이승칠;정광희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.1
    • /
    • pp.35-41
    • /
    • 2003
  • In this paper statistics on the radiation field waveforms produced by stepped leaders just prior to lightning return strokes were described. As a parameter of stepped leader pulse characteristics, the time interval between the final leader pulse and return stroke peak, the pause time between stepped leaders, the ratio of the final leader peak to the return stroke peak and the stepped leader pulse width at half maximum were examined. The average time intervals between the final leader pulse and return stroke peak were about 16.2 and 14.8$mutextrm{s}$ for the positive and negative polarities, respectively. When the stepped leader approaches closely to ground, the time interval between leader steps was decreased and the mean value was about 17$mutextrm{s}$, and the present results were in reasonable agreement with the data observed in Florida and Japan. The large fraction of the ratios of the final stepped leader pulse to the lightning return stroke peak were distributed over the range from 5 to 35% and in average the ratio of the final leader pulse to the return stroke peak was 17.4$\pm$11.9% for the positive and 18.5$\pm$9.4% for the negative electric field waveforms. In addition, the mean pulse widths at half maximum of the stepped leaders are 1.4Us with a standard deviation of 0.9 for the positive Polarity and 2.2us with a standard deviation of 1.2 for the negative polarity, respectively.

A Study on the Relationship between Aging and Partial Discharge Characteristics of the Mica/Epoxy Composite Insulation Systems (l) (Mica/Epoxy 복합 절연계통의 부분방전 특성과 열화 관계에 관한 연구(I))

  • Kang, D.S.;Lee, W.Y.;Park, C.H.;Kwak, Y.S.;Kim, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.976-979
    • /
    • 1992
  • There are lots of problem which are delaminations and partial discharge of insulation materials in high-voltage rotating machines caused by mechanical, electrical and thermal aging. Several experiments have been aiming at finding the useful diagnostic parameters from the partial discharge characteristics by applying a new measurement techniques. This paper deals with the partial discharge characteristics (pulse height, pulse angle, pulse frequency spectrum and time interval), which may be a useful diagnostic concept in predicting insulation condition of mica/epoxy composite insulation materials, by using several measurement equipments (frequency spectrum analyzer. multichannel analyzer and time interval analyzer).