• 제목/요약/키워드: Pulse Heating

검색결과 162건 처리시간 0.031초

새로운 유도가열용 소프트 스위칭 고주파 인버터 (Soft Switching High Frequency Inverter for New Induction Heating)

  • 김칠용;문상필;김영문;김해재;류재엽;김수욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.119-124
    • /
    • 2007
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Pull)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

유도가열용 ZCS PWM SEPP 고주파 인버터 (Induction Heating ZCS PWM SEPP High Frequency Inverter)

  • 문상필;권순걸;이종걸;주석민;강신출
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.241-243
    • /
    • 2008
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Full)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

뉴로퍼지 제어기를 이용한 고주파 유도 가열기의 시변부하에 대한 정전력 제어 (The power regulation of a High-Frequency Induction Heating System with time variance load using a neural fuzzy controller)

  • 장종승;김승철;임영도
    • 한국정보통신학회논문지
    • /
    • 제2권2호
    • /
    • pp.223-230
    • /
    • 1998
  • 본 논문은 뉴랄퍼지를 이용한 디지탈식 제어기를 고주파 유도 가열기의 전력 조절을 위해 IGBT를 사용한 위상 전이(Phase-Shift) 펄스폭 변조(PWM)와 펄스 주파수 변조(PFM)가 조절되는 공진 고주파 인버터를 응용한 유도가열기를 설명한다. 이는 실제로 산업 현장에서 20KHz~500KHz 유도 가열 및 유도 용해 전원 장치용으로 쓰인다. 위상 전이(Phase-Shift) PWM 정전력 조절 기술을 바탕으로 한 적응 주파수 추종 기법은 스위칭 손실을 최소화하고 전력조절을 용이하게 하기 위해 소개되어졌다. IGBT를 사용하여 실험적으로 만들어진 실험장치는 성공적으로 논증과 토의가 되어졌다.

  • PDF

펄스포밍의 스위칭 제어기술을 적용한 경두개 자기자극장치 (Pulse forming's switching control adopted a Transcranial Magnetic Stimulation Biomedical engineering, Dongju College University)

  • 김휘영
    • 한국정보통신학회논문지
    • /
    • 제14권3호
    • /
    • pp.729-736
    • /
    • 2010
  • 본 연구에서는, 펄스포밍 제어기술과 펄스 성형을 가지는 자기 자극장치에 대해 언급 하고자 한다. 자기자극장치는 5-100초 사이에 펄스성형 기술적용과 순간적 방전코일 전류 6kA까지 상승되므로 스너버 회로를 가지는 IGBT 전력소자를 사용하였다. 57-67%의 열손실을 줄였고, 2-34%의 적은 에너지를 사용한 유도전계펄스로 전형적인 코사인 펄스와 매칭 되는것을 알수가 있었다. 자기자극장치는 펄스성형하는 기술 증가와 함께 한계 펄스진폭의 예측 되는 감소인 20-100초 사이에서 펄스성형 기술을 운동신경에 활발한 자극하기 위하여 사용된다. 자기 자극장치 프로트 타입에서 이용된 기초과학 기술에 의하여 기능을 확장할 수 있고, 전력소비를 줄일 수 있었고, 자기자극장치의 열손실에 대해서도 축소할 수가 있어, 더 나은 연구와 치료에 통해 응용할 수가 있다.

주파수 변조 기법을 이용한 전압 클램프 특성을 갖는 유도가열용 Class-E 인버터의 새로운 제어에 관한 연구 (A Study on the New Control Scheme of Class-I Inverter for IH-Jar Applications with Clamped Voltage Characteristics Using Pulse frequency Modulation)

  • 이동윤;최영덕;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권3호
    • /
    • pp.133-139
    • /
    • 2003
  • In this paper, a new control scheme of Class-E inverter for Induction Heating (IH) Jar applications with clamped voltage characteristics using Pulse-Frequency-Modulation (PFM) is introduced. To reduce the voltage stress of switch, the proposed PFM control scheme doesn't need any auxiliary circuit in comparison to a family of Active Clamped Class-E (ACCE) inverter. It can decrease voltage stress of switch through modulation of switching frequency. The Class-E inverter using the proposed control scheme has the advantage of not only the same output power when it is compared with a Hybrid-Active Clamped Class-E (Hybrid-ACCE) inverter but also Zero-Voltage-Switching (ZVS), which are characteristics of conventional Class-E and ACCE inverter. The control principles and analysis of proposed method are explained in detail and its validity is verified through simulation and experimental results.

구강 내부 맥파 계측을 위한 센서 시스템 연구 (A Study on the Arterial Pulse Wave Measuring System of an Oral Cavity)

  • 김경호
    • 반도체디스플레이기술학회지
    • /
    • 제6권4호
    • /
    • pp.43-47
    • /
    • 2007
  • In this paper, we propose a novel sensor system for measuring the arterial pulse in an oral cavity. In order to measure pulse wave in oral cavity, the proposed system is designed with reflection type arterial wave sensor, not by using transmission type arterial pulse wave sensor. Driving circuit through pulse current is designed for solving self-heating problem of LED. The effectiveness of the proposed sensor system is compared with pulse wave between pulse wave of oral cavity and other body parts as well as with characteristic measurements. The experiment shows that the proposed sensor system is adaptive to capturing consecutive and meaningful biometric signals through the variation of pulse wave changes in oral cavity when exercising. The study result expects to design and develop mobile sensors which could be adapted to healthcare devices.

  • PDF

고온을 받은 콘크리트의 공학적 특성 (The Engineering Properties of Concrete Exposed at High Temperature)

  • 권영진;김용로;장재봉;김무한
    • 한국화재소방학회논문지
    • /
    • 제18권1호
    • /
    • pp.31-36
    • /
    • 2004
  • 본 연구는 잔골재 및 혼화재 종류, W/C에 따른 콘크리트의 폭열성상 및 압축강도 초음파속도 등의 공학적 특성을 검토함으로서 폭열 방지 및 화재 피해를 입은 콘크리트 구조물의 재사용과 보수보강, 안전도평가 등에 기초적인 자료를 제시하고자 한다. 폭열성상을 살펴보면, 잔골재에 따라서는 바다모래를 사용한 경우 폭열이 발생하지 않았거나 약간의 폭열이 나타나는 정도이나 재생잔골재나 부순모래를 사용한 경우에는 폭열이 심하게 나타났다. 또한 혼화재 종류에 따라서는 대체로 유사한 폭열성상을 나타내었다. 한편, W/C 30.5%의 고강도 영역에서는 대부분 폭열하였으나 W/C 55%의 보통강도 영역에서는 대부분 폭열하지 않았다. 잔존 압축강도는 W/C 55%의 경우 평균 45%로 나타났으며, W/C 30.5%의 경우에는 평균 64%로 나타났다. 초음파속도는 잔골재 종류 및 W/C, 가열시간에 따라 다르게 나타났으며, 가열 후 3개월이 가열 후 1개월보다 약 1.3∼8.4%의 초음파속도 회복을 보였다.

Effects of Local Heating on Whole Body Skin Temperature - Centered on the Comparison of Old Women & Female Collegians -

  • Shim, Boo-Ja
    • 패션비즈니스
    • /
    • 제6권3호
    • /
    • pp.84-93
    • /
    • 2002
  • The purpose of this study was to design functional clothing based on the physical characteristics of old women. The subjects of this experiment were 5 healthy old women and 5 college women. While the subjects were exposed to the circumstances of $28{\pm}0.5^{\circ}C$ and local heating at 7 areas (chest, abdomen, back, loin, hand, thigh and instep), their skin temperature, physiological reaction and psychological reaction were determined. The conclusions about the effects of local heating are as follows : 1. Skin temperature before heating was in the order of head-neck> trunk> upper limbs> lower limbs (Group A: old subjects) and head-neck> trunk> lower limbs> upper limbs (Group B: young subjects). 2. The heating pad was attached and detached for 30 minutes each. The sharpest rise and fall were recorded at 5 minutes with the pad on and off. Both groups had great changes in the body parts near trunk. 3. With the pad on and off, both groups showed no change in body temperature, blood pressure, and pulse rate. 4. Concerning the pervasive effects of local heating on whole body skin temperature, loin heating greatly increased other body parts in Group A. In Group B, the effects were large in heating chest, abdomen, back, loin, and thigh. 5. The loin part of old women has the greatest pervasive effect of local body heating.

펄스화학기상침트법에 의한 탄소/탄소 복합재료의 치밀화에 있어서 가스유지시간 유무의 영향 (Densification of Carbon/Carbon Composites by Pulse CVI with and without Residence)

  • 이용근;류호진;박희동
    • 한국세라믹학회지
    • /
    • 제33권8호
    • /
    • pp.935-941
    • /
    • 1996
  • Two-dimensional carbon/carbon preforms made of PAN-based carbon yarn and phenolic resin were densified with pyrolysis of propane by pulse chemical vapor infiltration where repeated the cycle of gas introduction residence and evacuation. Maximim density increment was 14% when infiltration temperature and time were 100$0^{\circ}C$ and 21.25 hrs respectively. The distribution of deposits of pyrocarbon by this process has been occurred uniformly in the bottom middle and top of carbon/carbon composite preform Pulse CVI with residence is most effective in increasing density and shortening infiltration time among isothermal CVI and pulse CVI with and without residence.

  • PDF

유도가열기용 직.병렬 공진 고주파 인버터의 설계 (Design of High Frequency Inverter with Series-parallel Load-Resonant for Induction Heating application)

  • 홍순일;손의식
    • 조명전기설비학회논문지
    • /
    • 제14권6호
    • /
    • pp.12-17
    • /
    • 2000
  • IN induction heating system the high frequency operation allows a rapid response to current fluctuation in the inverter and result in improved welding quality. To work induction heating of nonferrous metals, a welding power supply is need high working frequency and high power. This paper is shown design technique for increasing working frequency in induction heating for welding coppers. A series-parallel resonate inverter consists of H-type bridges, each of whose arms is composed of a combination of two parallel IGBTs. Inverter operating with the fixed frequency is controlled by pulse width modulation (PWM). As switching adapted the Zero-Voltage Switching technique to reduce switching losses the system is high efficiency. The propose inverter has feature which is high efficiency for very wide load variations with a narrow range of duty cycle ratio control and load short circuit capability. Detailed experimental results obtained from a 48[V] output, 500[W] experimental inverter are presented to verify the concept.

  • PDF