• Title/Summary/Keyword: Pulse Analyzer

Search Result 152, Processing Time 0.029 seconds

A Comparative Study on the Pulse Wave Variables and Sasang Constitution in Hypertension Patients and Healthy Subjects (고혈압 환자와 건강인의 맥상과 사상체질에 관한 연구)

  • Choi, Yong-Seok;Kim, Kyung-Yo;Hwang, Seung-Yeon;Choi, Chul-Won;Kim, Hyun-Hee;Joo, Jong-Cheon
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.2
    • /
    • pp.127-142
    • /
    • 2007
  • 1. Objectives We studied the characteristics of pulse wave variables in hypertensive patients and healthy subjects and would develope the program diagnosing Sasang Constitution. 2. Methods Healthy subjects and hypertensive patients were measured with pulse analyzer. In each of healthy and hypertensive group, means of pulse analyzer variables were compared among Constitution. On these bases of these results, decision tree composed of several rules were developed. 3. Results and Conclusions Decision tree with 72.13% accuracy were developed. (1) if h5(Cheok) < 2.325 & Wm/t(Cheok) < 0.238281 then class = Soeumin (2) if h5(Cheok) < 2.325 & Wm/t(Cheok) ${\ge}$ 0.238281 then class = Taeumin (3) if h5(Cheok) ${\ge}$ 2.325 & t1(Chon) ${\ge}$ 0.143 then class = Soyangin (4) if h5(Cheok) ${\ge}$ 2.325 & t1(Chon) < 0.143 & h3/h1(Cheok) ${\ge}$ 0.963601 then class = Soyangin (5) if h5(Cheok) ${\ge}$ 2.325 & t1(Chon) < 0.143 & h3/h1(Cheok) < 0.963601 & sum of pulse pressure(SPP) of Gwan ${\ge}$ 618 then class = Taeumin (6) if h5(Cheok) ${\ge}$ 2.325 & t1(Chon) < 0.143 & h3/h1(Cheok) < 0.963601 & sum of pulse pressure(SPP) of Gwan < 618 & t3(Chon) < 0.209 then class = Soeumin (7) if h5(Cheok) ${\ge}$ 2.325 & t1(Chon) < 0.143 & h3/h1(Cheok) < 0.936601 & sum of pulse pressure(SPP) of Gwan < 618 & t3(Chon) ${\ge}$ then class = Taeumin From above results, we concluded that pulse analyzer is useful instrument to decide Sasang Constitution.

  • PDF

Analysing of the recent trends on the constitution diagnosis and treatment device patents (체질진단 및 치료기기 최신 특허동향 분석)

  • Lee, Yu-Jung;Lee, Jeon;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.2 s.20
    • /
    • pp.91-100
    • /
    • 2007
  • In this paper, We tried to analyze the patent trend on constitution diagnosis and treatment related technologies. For this, constitution diagnosis and treatment related technologies divided into 16 sub-technology by the advisory committee. And we analyzed patents applied in Korea, Japan, U.S.A., China, and Europe. The 16 sub-technology consist of pulse analyzer, skin diagnosis, tongue analyzer, face and body detector, face analyzer, voice analyzer, intelligence ontology, meridian diagnosis, infrared thermography, electric stimulation, laser, high and low frequency, physical, magnetic, and ultrasound therapy. As a result we found that patents of constitution diagnosis and treatment in Korea has been growing steadily in both quality and quantity since 1980s. The number of patent the pulse analyzer and low frequency therapy are larger than others. But applied relevant international patents, marketability of the patent and Cites per Patent (CPP) index are shown to be very low. In conclusion, to occupy key original technologies of the Oriental medical device, we need to apply more patent of the whole related technology and international patents.

  • PDF

Effect of Laser Acupuncture on Arterial Pulse

  • Cho, Jaekyong;Kang, Dong Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.191-197
    • /
    • 2015
  • Laser acupuncture is defined as the stimulation of traditional acupuncture points with low-intensity, nonthermal laser irradiation. Possible advantages in using laser acupuncture are the noninvasive, painless and low risks of infection treatment. The purpose of this study is to assess the effect of laser acupuncture on the quality and waveform of arterial pulses. Ten acupuncture points were stimulated repeatedly three times in 30 individuals by laser with emission in the near infrared spectral region (808 nm) using an out power and power density of 45 mW and $143W/cm^2$. The analysis of pulse quality and waveform was performed based on the measurement of arterial pressure of the left and right wrist, using a 3-dimensional blood pressure pulse analyzer. Excess-like pulse quality of subjects before laser acupuncture changed significantly to balanced pulse quality after 10, 20, and 30 minutes of laser acupuncture; coefficient of deficient or excess, $C_{DE}$, decreased significantly from 0.68 before acupuncture to 0.61, 0.55, and 0.55 after 10, 20, 30 minutes of laser acupuncture ($$p{\leq_-}0.006$$), respectively. Other pulse qualities, floating or sinking, slow or rapid, choppy or slippery did not change significantly by laser acupuncture (p > 0.05). Pulse waveform analysis showed that amplitude of main peak (systolic function or aortic compliance, $h_1$) of left and right artery pulse waves decreased significantly after 10, 20, and 30 minutes of laser acupuncture (p < 0.05). Other parameters, duration of one cardiac cycle (T), duration of rapid systolic ejection ($T_1$), duration of the systolic phase ($T_4$), and duration of the diastolic phase ($T_5$) of left and right artery pulses did not change significantly after laser acupuncture (p > 0.05).

A Study on Electronic Circuit for Liwe-Time Correction in Multi-Channel Analyzer : Survey and Analysis (방사선 스펙트럼 계측기 (Multi-Channel Analyzer)의 Live-Time 보상회로에 관한 연구)

  • Hwang, I.K.;Kwon, K.H.;Song, S.J.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.784-791
    • /
    • 1995
  • This paper describes the counting-loss problem for radiation measurement Multi-channel analyzers and spectrometers adopt various techniques for compensation for counting-losses in process-ing the radiation pulses from a detector. Researchers hate tried to seek the best solution for the problem. However, any absolute solution has not been reached and vendors of radiation instruments use their own algorithms individually. This survey explains the various compensation algorithms with electronic implementation approach. Shortcomings and merits of each algorithm are also reviewed and a direction is suggested of the recommendable development strategy for counting-loss compensation.

  • PDF

Proposal of pulse parameter useful for pulse wave analysis in oriental medicine: Preliminary study on floating and sinking pulses (통계분석을 통한 한의 맥진에 유용한 파라미터 도출: 부침맥을 중심으로 한 예비연구)

  • Lee, Jeon;Lee, Yu-Jung;Lee, Hae-Jung;Choi, Eun-Ji;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.244-246
    • /
    • 2006
  • In this study, we search some parameters well-related to floating-sinking pulse by statistical analysis, because these pulses are frequently used in clinic. Pulse signals were acquired by 3D pulse analyzer and 30 subjects consist of 15 people diagnosed as floating pulse and 15 people diagnosed as sinking pulse by oriental doctors who have over 5 years clinical experience. Then, we made a representative beat template for each subject and, through a peak detection algorithm, we calculated several pulse parameters. To find the parameters related to floating-sinking pulse, we performed statistical testing with 17 parameters through the independence sampling, t-test. As a result, there is the biggest difference between pressure, the maximum pulse pressure, diastolic area(Ad) and float-sink data. (p < .05).

  • PDF

Design and Fabrication of a LabView Based Partial Discharge Analyzer (LabView 기반 부분방전 분석장치의 설계 및 제작)

  • Cha, Hyeon-Kyu;Lee, Jung-Yoon;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.3
    • /
    • pp.229-235
    • /
    • 2012
  • This paper dealt with the fabrication of a partial discharge (PD) analyzer for insulation diagnosis of power facilities like transformers, cables and gas-insulated switchgears. An analytic algorithm for the phase (${\phi}$), the magnitude (q), and the pulse count (n) of PD pulse was designed and a time-frequency (TF) map algorithm was applied in the system to eliminate noises by analyzing the time and the frequency component of signals. All the algorithms were operated by a LabView graphical program. The detection circuit consists of a coupling capacitor, a detection impedance, and a low noise amplifier. A plane-plane and a point-plane electrode system were fabricated to simulate different types of insulation defects. In the experiment, we could easily understand the characteristics of PD pulses using the prototype PD analyzer.

Characteristics of Pulse Waves in Various Age Categories and Applicability of Pulse Wave to Metabolic Syndrome Using Pen-type Piezoresistive Sensor (펜타입 압저항 센서를 활용한 연령별 맥파 특성 및 맥파의 대사증후군에의 적용 가능성 평가)

  • Ha, Ye-Jin;Cho, Mun-Young;Yun, Jong-Min;Jun, Kyu-Sang;Park, Soo-Jung;Shin, Sun-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.33 no.3
    • /
    • pp.257-271
    • /
    • 2012
  • Objectives : The purpose of this study was to confirm that the pulse analyzer is useful for analyzing characteristics of variables of pulse waves in age categories, evaluating pulse waves of the metabolic syndrome group, compared with those of the non-metabolic syndrome group in Korean adults. Methods : The pulse wave variables were measured in Guan of all 1,056 subjects by the pulse analyzer, using a pen-type piezoresistive sensor. The physical measurement, blood test and survey were also performed by each subject. Results : In the age categories, height of pre-incisura (h2), height of tidal wave (h3), area of percussion wave (Aw), and width of percussion wave (w) increased in accordance with increase in age. While ratio of systolic period area (As) went up according to the increase of age, ratio of diastolic period area (Ad) went down. Radial augmentation index (R-AI), h2/h1, h3/h1, w/t and angle of percussion wave went up by aging, generally. Aw rate (Aw/At) also increased. Among the metabolic syndrome group, in the ages of 19 and 44, ratio of systolic period area (As) was higher and ratio of diastolic period area (Ad) was lower than in the non-metabolic group. w/t, Aw/At, and angle of percussion wave were higher than in the non-metabolic syndrome group. Among the metabolic syndrome group over the age of 60, height of pre-incisura (h2), height of tidal wave (h3), total area (At), area of percussion wave (Aw), radial augmentation index (R-AI), h2/h1 and h3/h1 were higher than in the non-metabolic syndrome group. Conclusions : The pulse analyzer is useful to analyze arterial stiffness in the age categories and in the metabolic syndrome group by some measures.

Multi-channel analyzer based on a novel pulse fitting analysis method

  • Wang, Qingshan;Zhang, Xiongjie;Meng, Xiangting;Wang, Bao;Wang, Dongyang;Zhou, Pengfei;Wang, Renbo;Tang, Bin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2023-2030
    • /
    • 2022
  • A novel pulse fitting analysis (PFA) method is presented for the acquisition of nuclear spectra. The charging process of the feedback capacitor in the resistive feedback charge-sensitive preamplifier is equivalent to the impulsive pulse, and its impulse response function (IRF) can be obtained by non-linear fitting of the falling edge of the nuclear pulse. The integral of the IRF excluding the baseline represents the energy deposition of the particles in the detector. In addition, since the non-linear fitting process in PFA method is difficult to achieve in the conventional architecture of spectroscopy system, a new multi-channel analyzer (MCA) based on Zynq SoC is proposed, which transmits all the data of nuclear pulses from the programmable logic (PL) to the processing system (PS) by high-speed AXI-Stream in order to implement PFA method with precision. The linearity of new MCA has been tested. The spectrum of 137Cs was obtained using LaBr3(Ce) scintillator detector, and was compared with commercial MCA by ORTEC. The results of tests indicate that the MCA based on PFA method has the same performance as the commercial MCA based on pulse height analysis (PHA) method and excellent linearity for γ-rays with different energies, which infers that PFA method is an effective and promising method for the acquisition of spectra. Furthermore, it provides a new solution for nuclear pulse processing algorithms involving regression and iterative processes.

Propagation characteristic analysis and measurement of gaussian pulse signals on the microstrip line (마이크로스트립 선로상 가우시안 펄스신호의 전파특성 해석 및 측정)

  • Rhee, Seoung-Yeop;Shin, Ho-Sub;Kim, Nam;Kwan, Weon-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.6
    • /
    • pp.1425-1432
    • /
    • 1998
  • The propagation properties of Gaussian pulse signals on the microstrip line are investigated by the Kirschning & Jansen's approximated equation to meet the frequency range of a pulse, accuracy, and geometrical requiremtns of the microstrip line. The dispersion of pulse signals is analyzed regarding to the relative permittivity .epsilon.$_{r}$, substrate height h and strip width w of the microstrip line. To verify theoretical results, several samples of 50.OMEGA. microstrip lines are fabricated. And the characteristics of pulse propagation along these lines are simple measured using VNA(Vector Network Analyzer) with time-domain analysis function. A fairly good agreement has been found between the measured pulse waveforms and computer simulations.

  • PDF