• 제목/요약/키워드: Pulsation Characteristics

검색결과 184건 처리시간 0.021초

Numerical simulation and experimental study of non-stationary downburst outflow based on wall jet model

  • Yongli Zhong;Yichen Liu;Hua Zhang;Zhitao Yan;Xinpeng Liu;Jun Luo;Kaihong Bai;Feng Li
    • Wind and Structures
    • /
    • 제38권2호
    • /
    • pp.129-146
    • /
    • 2024
  • Aiming at the problem of non-stationary wind field simulation of downbursts, a non-stationary down-burst generation system was designed by adding a nozzle and program control valve to the inlet of the original wall jet model. The computational fluid dynamics (CFD) method was used to simulate the downburst. Firstly, the two-dimensional (2D) model was used to study the outflow situation, and the database of working conditions was formed. Then the combined superposition of working conditions was carried out to simulate the full-scale measured downburst. The three-dimensional (3D) large eddy simulation (LES) was used for further verification based on this superposition condition. Finally, the wind tunnel test is used to further verify. The results show that after the valve is opened, the wind ve-locity at low altitude increases rapidly, then stays stable, and the wind velocity at each point fluctuates. The velocity of the 2D model matches the wind velocity trend of the measured downburst well. The 3D model matches the measured downburst flow in terms of wind velocity and pulsation characteris-tics. The time-varying mean wind velocity of the wind tunnel test is in better agreement with the meas-ured time-varying mean wind velocity of the downburst. The power spectrum of fluctuating wind ve-locity at different vertical heights for the test condition also agrees well with the von Karman spectrum, and conforms to the "-5/3" law. The vertical profile of the maximum time-varying average wind veloci-ty obtained from the test shows the basic characteristics of the typical wind profile of the downburst. The effectiveness of the downburst generation system is verified.

5상 유도전동기 구동을 위한 수정된 직접 토크제어 시스템 (The Modified Direct Torque Control System for Five-Phase Induction Motor Drives)

  • 김민회;김남훈;백원식
    • 조명전기설비학회논문지
    • /
    • 제23권2호
    • /
    • pp.138-147
    • /
    • 2009
  • 본 논문에서는 5상 농형유도전동기(Five-phase squirrel-cage induction motor)의 수정된 직접 토크제어(Direct torque control, DTC) 시스템을 제안한다. 5상 유도전동기 구동은 추가적인 자유도로 인하여 개선된 특성이 얻어짐과 동시에 일반적인 3상 유도전동기에 비해 토크의 맥동이 감소하며, 신뢰성 증가와 같은 장점을 가진다. 5상 유도전동기의 직접 토크제어는 인버터 구동시스템이 기존의 3상 인버터가 8개의 공간전압 벡터를 가지고 있는 것에 비해서 32개의 공간전압 벡터를 제공하기 때문에 여러 가지 장점이 있다. 그러나 5상 전동기의 경우는 제3공간 고조파 성분으로 인하여 구조적인 단점을 가지고 있어 고조파 성분의 전류제어가 요구된다. 따라서 이 논문에서는 5상 유도전동기의 특성을 개선하기 위하여 제3고조파 전류성분을 제어할 수 있는 수정된 직접 토크제어 시스템을 제시한다. 전통적인 5상 유도전동기의 직접 토크제어와 제안된 직접 토크제어 시스템의 운전특성을 검증하기 위하여, 디지털 제어기로 32[bit] 고정소수점 DSP인 TMS320F2812를 사용하여 2.2[kW] 5상 유도전동기의 속도제어 시스템을 구성하여 동특성을 관찰한 결과 우수한 특성이 얻어짐을 확인하였다.

CFD 해석을 이용한 Balloon형 인공심폐기 설계를 위한 구조적 해석 (Structural Analysis for Constructing a Balloon Type Extracoporeal Membrane Oxygenator using CFD Analysis)

  • 박영란;심정연;김기범;김상진;강형섭;김진상;김민호;홍철운;김성종
    • Korean Chemical Engineering Research
    • /
    • 제49권2호
    • /
    • pp.238-243
    • /
    • 2011
  • 본 연구는 기존의 인공심폐기의 단점을 보완하기 위하여 혈액펌프를 사용하지 않고 혈류의 흐름을 유도할 수 있는 기구(balloon)형 인공심폐기 설계를 위한 구조적 해석을 시도하였다. 가상의 모형 인공심폐기 내에서의 혈류의 흐름패턴을 분석하기 위하여 CFD 모델링 방법을 사용하였다. 이 시스템의 작동원리는 막 산화기 주위를 기구를 사용하여 압력하중을 인가하여 주기적으로 수축.이완되도록 하였으며, 시간에 따라 변화하는 시간 함수 값은 sine 반주기와 sine 주기를 계산하여 적용하였다. 이와 같은 방법으로 기구형 인공심폐기를 설계할 경우 한 방향에 대한 혈류의 움직임을 유도할 수 있다는 가정 하에 구조적 해석을 하였다. 실험결과 CFD 시뮬레이션을 통하여 인공심폐기의 입구와 출구에 서의 혈류의 속도와 압력을 측정하여 분석한 결과 한 방향에 대한 혈류의 유동이 발생하는 것을 확인하였다. 이와 같은 CFD 시뮬레이션은 혈류의 흐름특성을 미리 예측할 수 있어 인공심폐기 설계에 있어서 최적화된 디자인을 제공할 수 있을 것이라 판단된다.

티벳의학에 대한 연구 - "사부의전(四部醫典).근본의전(根本醫典)"을 중심으로 (Study on "Four Tantras", the Prime Textbook of Tibetan Medicine)

  • 장은영;윤창열
    • 대한한의학원전학회지
    • /
    • 제11권1호
    • /
    • pp.416-512
    • /
    • 1998
  • The following conclusions are obtained from the studies on the chapters concerning phisiology, pathology, daily conduct, materia medica, pulse, and urinalysis from , of the "Four Tantras". 1. The theoretical basis forming the Tibetan Medicine is the substance of phlegm, bile, and wind each of which is divided into five kinds. These phisiological substances can be transformed into pathological factors when certain environment is formed. 2. In embryology, the semen of the father and menstral blood of mother is considered the most important condition in conception, and the Five factors are regarded as important. There is a detailed explanation of development of the fetus while it stays in the womb of mother during 38weeks, such as the formation of the viscera, channels, sense organs, etc. 3. There is metaphor which compares the human body with the king's palace. With the development of human anatomy, there is the detailed anatomical picture of anterior and posterior aspects of human body. And also there is the measurement of physiological constitution and the three fluids. 4. In division of the channels, they concerned the now of the blood and distribution of the nerve fibers, and each channel is connected with one another. The division of the cannel is namely embryonic channel, channel of existence, channel of connection, and the course of life principle. 5. The seven bodily constituents and three factors of phlegm, bile, and wind are important in sustaining the life of human body as well as growth and maturization, and when their equilibrium is broken, the human body is degnerated, and finally death comes. 6. The signs of death is divided into distant sign, remote sign, certain sign. and uncertain sign, and is used as a clue in diagnosis of the disease. Especially there is a mention about the mechanism of the dreams, and different dreams according to the condition of the patient. 7. In pathology, there is the cause of the disease, the environmental factors which can induce disease, the path by which disease come into the human body, the characteristics of the disease, and the kinds of disease. 8. There is a mention about the conduct, and it is divided into the daily conduct, the mental attitude, and the side-effects which can occur when one puts up with the physiological actions of the body. 9. The daily diet is divided into food and beverage. The food is divided again into grain, meat, fat, boiled food, and spiced food, and the beverage into milk, water, and wine. 10. The pulsation should be taken in lift hand to diagnose heart, small intestine, stomach, spleen, kidney, reproductive organ, and in right hand jungs, large intestine, liver, gall bladder, kidney, and bladder. In the healthy person, the pulse moves 5times in one perspiration, and the type of pulse is constant while the pulse moves 100times. But unhealthy person's pulse is different from this. The urinalysis is the unique part of Tibetan Medicine, and is important in examination of the disease. One should decide which of the three factors are dominant by the obervation of the color, amount of the steam and how long it lasts, odour, foam, and the shape of the swirl in three different states when the urine is hot, warm, and cold. One can determine the life of the patient and which viscera is the cause of the disease by the pulse, and whether the nature of the disease is hot or cold by the urinalysis. 11. The materia medica contains gemstones, minerals, plateau medication, and meat products.

  • PDF