• Title/Summary/Keyword: Pulmonary ventilation

Search Result 254, Processing Time 0.028 seconds

Correlation of Preoperative Pulmonary Function Testing and with Pulmonary Complication in Patients after Pneumonectomy (술전 폐기능과 전폐적출술후 폐합병증과의 연관성)

  • Bae, Byeong-U;Jeong, Hwang-Gyu
    • Journal of Chest Surgery
    • /
    • v.26 no.8
    • /
    • pp.620-626
    • /
    • 1993
  • Determination of preoperatibe pulmonary function is crucial in avoiding complications from pulmonary resection, especially pneumonectomy. Postoperative morbidity and mortality were correlated with the preoperative results of five widely used tests of pulmonary function in 40 patients who underwent pneumonectomy for bronchiectasis, pulmonary tuberculosis, and carcinoma of the lung. Factors analyzed following operation included 30-day mortality, the incidence of arrhythmia, the frepuency of respiratory complications, and the number of individuals requiring prolonged mechanical ventilation. There were statistically significant differences[p<0.001]in mean values among FVC, FEV1, FEV1/FVC and MVV. But the difference of the FEF25-75% was not statistically significant.

  • PDF

Radioaerosol Inhalation Imaging in Bronchial Asthma (기관지 천식의 연무흡입 폐환기스캔 소견)

  • Kim, Bum-Soo;Park, Young-Ha;Park, Jeong-Mi;Chung, Myung-Hee;Chung, Soo-Kyo;Shinn, Kyung-Sub;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.1
    • /
    • pp.46-52
    • /
    • 1991
  • Radioaerosol inhalation imaging (RII) has been used in radionuclide pulmonary studies for the past 20 years. The method is well accepted for assessing regional ventilation because of its usefulness, easy fabrication and simple application system. To evaluate its clinical utility in the study of impaired regional ventilation in bronchial asthma, we obtained and analysed RIIs in 31 patients (16 women and 15 men; age ranging 21-76 years) with typical bronchial asthma at the Department of Radiology, Kangnam St. Mary's Hospital, Catholic University Medical college, from January, 1988 to August, 1989. Scintiscans were obtained with radioaerosol produced by a BARC(Bhabha Atomic Reserch Center, India) nebulizer with 15 mCi of $^{99m}Tc-phytate$. The scanning was peformed in anterior, posterior and lateral projections following 5-minute inhalation of radioaerosol on sitting position. The scans were analyzed and correlated with the results of pulmonary function study and the findings of chest radiography. Fifteen patients had concomitant lung perfusion image with $^{99m}Tc-MAA$. Follow-up scans were obtained in 5 patients after bronchodilator therapy. The patients were divided into (1) attack type (4 patients), (2) resistant type (5 patients), (3) remittent type (10 patients) and (4) bronchitic type (12 patients). Chest radiography showed hyperinflation, altered pulmonary vascularity, thickening of the bronchial wall and accentuation of basal interstitial markings in 26 of the 31 patients. Chest radiographs were norma! in the remaining 5 patients. Regardless of type, the findings of RII were basically the same, and characterized by the deposition of radioaerosol in the central parts or in the main respiratory air ways along with mottled nonsegmental ventilation defects in the periphery. Peripheral parenchymal defects were more extensive than that of expected findings from clinical symptoms, pulmonary function test and chest radiograph. Broomstick sign was present in 17 patients. The abnormality of RII was poorly correlated with perfusion scans. In all 5 patients treated with bronchodilators, follow-up study demonstrated a decrease in the degree of radioaerosol deposition in the central air way with improved ventilation defects. This study indicates that RII is a useful technique for the evaluation of regional ventilation abnormality and the effect of treatment with bronchodilators in patients with bronchial asthma.

  • PDF

Comparison of Lung Ventilation Scan Using Technegas and $^{99m}Tc-DTPA$ Aerosol (Technegas 환기스캔과 $^{99m}Tc-DTPA$ Aerosol 스캔의 비교)

  • Choi, Yoon-Ho;Kim, Sang-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Kim, Keun-Youl;Koh, Chang-Soon;Koong, Sung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.237-243
    • /
    • 1990
  • Pulmonary embolism demands rapid and accurate diagnosis. And ventilation imaging has greatly improved the diagnostic accuracy of pulmonary embolism in addition to perfusion imaging. Agents currently used include xenon-133, krypton-81m and technetium-99m radioaerosols. However radioactive gases are compromised by availability and cost for krypton-81m, radiation dose, gamma energy and non?physiologic behaviour for xenon-133. Radioaerosols of technetium-99m componds are rapidly cleared from the lung after inhalation, and their relative low effeciency (specific radioactivity) and wide distribution of particle sizes make them also suboptimum. A new ventilation agent, Technegas is a suspension of structured graphite ellipsoids with diameter below 20nm, labelled with $^{99m}Tc$ in a carrier gas of Argon. This report describes the authors' clinical experience with Technegas. This is the first reported clinical study of this agent in Korea. A comparison of Technegas and $^{99m}Tc-DTPA$ aerosol was performed in 12 patients with various pulmonary diseases such as COPD, pulmonary tuberculosis and pleural effusion. All patients were studied with $^{99m}Tc-DTPA$ aerosol inhalation and Technegas ventilation. In both studies image quality was assessed (1) semiquantitatively by scoring bronchial and gastric activity, (2) subjectively by direct visual comparison of peripheral lung images and (3) quantitatively by computing the peripheral penetration index(PI) for each lungs. The bronchial activites were seen in 7 out of 12 cases with $^{99m}Tc-DTPA$ aerosol and in 5/12 with Technegas. The gastric activities were seen in 5/12 and 1/12 cases respectively. The average values of PI were 61.26% with $^{99m}Tc-DTPA$ aerosol and 69.20% with Technegas (p>0.05). Using $^{99m}Tc-DTPA$ aerosol, COPD patients showed deposition in the central airways with poor visualization of the peripheral areas of the lungs. In Technegas studies these phenomena were less prominent, and the examination is well tolerated by pateients and requires only a minimum of patient cooperation. With superiority of easy availability and handling, better physical characteristics and favorable Image quality, Technegas is a Promising agent for lung ventilation scanning.

  • PDF

Tuberculosis Infection Control in Health-Care Facilities: Environmental Control and Personal Protection

  • Lee, Ji Yeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.79 no.4
    • /
    • pp.234-240
    • /
    • 2016
  • Transmission of tuberculosis (TB) is a recognized risk to patients and healthcare workers in healthcare settings. The literature review suggests that implementation of combination control measures reduces the risk of TB transmission. Guidelines suggest a three-level hierarchy of controls including administrative, environmental, and respiratory protection. Among environmental controls, installation of ventilation systems is a priority because ventilation reduces the number of infectious particles in the air. Natural ventilation is cost-effective but depends on climatic conditions. Supplemented intervention such as air-cleaning methods including high efficiency particulate air filtration and ultraviolet germicidal irradiation should be considered in areas where adequate ventilation is difficult to achieve. Personal protective equipment including particulate respirators provides additional benefit when administrative and environmental controls cannot assure protection.

Total Anomalous Pulmonary Venous Connection; Surgical Correction and Late Pulmonary Venous Obstruction (총폐정맥 환류이상의 수술적 교정및 후발성 폐정맥 협착)

  • Seo, Dong-Man;Song, Myeong-Geun
    • Journal of Chest Surgery
    • /
    • v.26 no.4
    • /
    • pp.260-265
    • /
    • 1993
  • Twelve patients underwent surgical correction of total anomalous pulmonary venous connection[TAPVC] between Sep. 1989 and May 1993. There were 9 boys and 3 girls whose ages ranged from 10 days to 17 month [median 1.2 month]. Six patients were less than 1 month of age at operation. The anomalous drainage was supracardiac in 6, cardiac in 2, infracardiac in 2, and mixed in 2. There were 3 early death, and its mortality rate was 25%. There were no operative mortality after Sep. 1991. Age at operation, presence of preoperative pulmonary venous obstruction, preoperative assisted ventilation and type of anomaly did not affect early mortality. Late pulmonary venous obstruction was developed in 4 patients between 1 month to 4 month after operation. Among these patients, 2 were died and one was reoperated and well, and the other one was not operated because of patient`s refusal. We conclude that late pulmonary venous obstruction is fatal and its early detection and correction is important for improving late survival.

  • PDF

Dynamic Chest X-Ray Using a Flat-Panel Detector System: Technique and Applications

  • Akinori Hata;Yoshitake Yamada;Rie Tanaka;Mizuki Nishino;Tomoyuki Hida;Takuya Hino;Masako Ueyama;Masahiro Yanagawa;Takeshi Kamitani;Atsuko Kurosaki;Shigeru Sanada;Masahiro Jinzaki;Kousei Ishigami;Noriyuki Tomiyama;Hiroshi Honda;Shoji Kudoh;Hiroto Hatabu
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.634-651
    • /
    • 2021
  • Dynamic X-ray (DXR) is a functional imaging technique that uses sequential images obtained by a flat-panel detector (FPD). This article aims to describe the mechanism of DXR and the analysis methods used as well as review the clinical evidence for its use. DXR analyzes dynamic changes on the basis of X-ray translucency and can be used for analysis of diaphragmatic kinetics, ventilation, and lung perfusion. It offers many advantages such as a high temporal resolution and flexibility in body positioning. Many clinical studies have reported the feasibility of DXR and its characteristic findings in pulmonary diseases. DXR may serve as an alternative to pulmonary function tests in patients requiring contact inhibition, including patients with suspected or confirmed coronavirus disease 2019 or other infectious diseases. Thus, DXR has a great potential to play an important role in the clinical setting. Further investigations are needed to utilize DXR more effectively and to establish it as a valuable diagnostic tool.

Radioaerosol Inhalation Lung Scan in Pulmonary Emphysema (폐기종의 연무흡입 폐환기스캔 소견)

  • Jeon, Jeong-Su;Park, Young-Ha;Chung, Soo-Kyo;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.229-236
    • /
    • 1990
  • Perfusion and ventilaion imagings of the lung are well established procedure for diagnosing pulmonary embolism, differentiation it from chronic obstructive lung disease, and making an early detection of chronic obstructive lung disease. To evaluate the usefulness of radioaerosol inhalation imaging (RII) in chronic obstructive lung disease, especially pulmonary emphysema, we analyzed RIIs of five normal adult non-smokers, five asymptomatic smokers (age 25-42 years with the mean 36), and 21 patients with pulmonry emphysema (age 59-78 years with the mean 67). Scintigrams were obtained with radioaerosol produced by a BARC nebulizer with 15 mCi of Tc-99m-phytate. Scanning was performed in the anterior, posterior, and lateral projections after five to 10-minute inhalation of the radioaerosol on sitting position. The scans were analyzed and correlated with the results of pulmonary function studies and chest radiographs. Also lung perfusion scan with $^{99m}Tc-MAA$ was performed in 12 patients. In five patients, we performed follow-up scans for the evaluation of the effects of a bronchodilator. Based on the X-ray findings and clinical symptoms, pulmonary emphysema was classified into four types: centrilobular (3 patients), panlobular (4 patients), intermediate (10 patients), and combined (4 patients). RII findings were patternized according to the type, extent, and intensity of the aerosol deposition in the central bronchial and bronchopulmonary system and lung parenchyma. 10 controls, normal five non-smokers and three asymptomatic smokers revealed homogeneous parenchymal deposition in the entire lung fields without central bronchial deposition. The remaining two of asymptomatic smokers revealed mild central airway deposition. The great majority of the patients showed either central (9/21) or combined type (10/21) of bronchopulmonary deposition and the remaining two patients peripheral bronchopulmonary deposition. Parenchymal aerosol deposition in pulmonary emphysema was diffuse (6/21), discrete(6/21), intermediate (3/21), or combined (6/21). In 12 patients studied also with perfusion scans, perfusion defects matched closely with ventilation defects in location and configuration. But the size of the ventilation defects was generally larger than the perfusion defects. In all four patients treated with bronchodilators, the follow-up study demonstrated decrease in abnormal of radioaerosol deposition in the central airway with improvement of ventilation defects. RII was useful technique for the evaluation of regional ventilatory abnormality and the effects of treatment with bronchodilators in pulmonary emphysema.

  • PDF

The Usefulness of Pressure-regulated Volume Control(PRVC) Mode in Mechanically Ventilated Patients with Unstable Respiratory Mechanics (기계 호흡 중 불안정한 호흡역학을 보인 환자에서 압력조절용적조정양식(Pressure-regulated Volume Control Mode)의 효용)

  • Sohn, Jang-Won;Koh, Youn-Suck;Lim, Chae-Man;Shim, Tae-Sun;Lee, Jong-Deog;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1318-1325
    • /
    • 1997
  • Background : Since the late 1960s, mechanical ventilation has been accomplished primarily using volume controlled ventilation(VCV). While VCV allows a set tidal volume to be guaranteed, VCV could bring about excessive airway pressures that may be lead to barotrauma in the patients with acute lung injury. With the increment of knowledge related to ventilator-induced lung injury, pressure controlled ventilation(PCV) has been frequently applied to these patients. But, PCV has a disadvantage of variable tidal volume delivery as pulmonary impedance changes. Since the concept of combining the positive attributes of VCV and PCV(dual control ventilation, DCV) was described firstly in 1992, a few DCV modes were introduced. Pressure-regulated volume control(PRVC) mode, a kind of DCV, is pressure-limited, time-cycled ventilation that uses tidal volume as a feedback control for continuously adjusting the pressure limit However, no clinical studies were published on the efficacy of PRVC until now. 'This investigation studied the efficacy of PRVC in the patients with unstable respiratory mechanics. Methods : The subjects were 8 mechanically ventilated patients(M : F=6 : 2, $56{\pm}26$ years) who showed unstable respiratory mechanics, which was defined by the coefficients of variation of peak inspiratory pressure for 15 minutes greater than 10% under VCV, or the coefficients of variation of tidal volume greater than 10% under PCV. The study was consisited of 3 modes application with VCV, PCV and PRVC for 15 minutes by random order. To obtain same tidal volume, inspiratory pressure setting was adjusted in PCV. Respiratory parameters were measured by pulmonary monitor(CP-100 pulmonary monitor, Bicore, Irvine, CA, USA). Results : 1) Mean tidal volumes($V_T$) in each mode were not different(VCV, $431{\pm}102ml$ ; PCV, $417{\pm}99ml$ ; PRVC, $414{\pm}97ml$) 2) The coefficient of variation(CV) of $V_T$ were $5.2{\pm}3.9%$ in VCV, $15.2{\pm}7.5%$ in PCV and $19.3{\pm}10.0%$ in PRVC. The CV of $V_T$ in PCV and PRVC were significantly greater than that in VCV(p<0.01). 3) Mean peak inspiratory pressure(PIP) in VCV($31.0{\pm}6.9cm$ $H_2O$) was higher than PIP in PCV($26.0{\pm}6.5cm$ $H_2O$) or PRVC($27.0{\pm}6.4cm$ $H_2O$)(p<0.05). 4) The CV of PIP were $13.9{\pm}3.7%$ in VCV, $4.9{\pm}2.6%$ in PVC and $12.2{\pm}7.0%$ in PRVC. The CV of PIP in VCV and PRVC were greater than that in PCV(p<0.01). Conclusions : Because of wide fluctuations of VT and PIP, PRVC mode did not seem to have advantages compared to VCV or PCV in the patients with unstable respiratory mechanics.

  • PDF

Evaluation of Parameters of Gas Exchange During Partial Liquid Ventilation in Normal Rabbit Lung (토끼의 정상 폐 모델에서 부분액체환기 시 가스교환에 영향을 주는 인자들에 대한 연구)

  • An, Chang-Hyeok;Koh, Young-Min;Park, Chong-Wung;Suh, Gee-Young;Koh, Won-Jung;Lim, Sung-Yong;Kim, Cheol-Hong;Ahn, Young-Mee;Chung, Man-Pyo;Kim, Ho-Joong;Kwon, O-Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.1
    • /
    • pp.14-23
    • /
    • 2002
  • Background: The opitmal ventilator setting during partial liquid ventilation(PLV) is controversial. This study investigated the effects of various gas exchange parameters during PLV in normal rabbit lungs in order to aid in the development of an optimal ventilator setting during PLV. Methods: Seven New-Zealand white rabbits were ventilated in pressure-controlled mode with the following settings; tidal volume($V_T$) 8 mL/kg, positive end-expiratory pressure(PEEP) 4 $cmH_2O$, inspiratory-to-expiratory ratio(I:E ratio) 1:2, fraction of inspired oxygen($F_TO_2$) 1.0. The respiration rate(RR) was adjusted to keep $PaCO_2$ between 35~45 mmHg. The ventilator settings were changed every 30 min in the following sequence : (1) Baseline, as the basal ventilator setting, (2) Inverse ratio, I:E ratio 2:1, (3) high PEEP, adjust PEEP to achieve the same mean inspiratory pressure (MIP) as in the inverse ratio, (4) High $V_T$, $V_T$ 15 mL/kg, (5) high RR, the same minute ventilation (MV) as in the High $V_T$. Subsequently, the same protocol was repeated after instilling 18 mL/kg of perfluorodecalin for PLV. The parameters of gas exchange, lung mechanics, and hemodynamics were examined. Results: (1) The gas ventilation(GV) group showed no significant changes in the $PaO_2$ at all phases. The $PaCO_2$ was lower and the pH was higher at the high $V_T$ and high RR phases(p<0.05). No significant changes in the lung mechanics and hemodynamics parameters were observed. (2) The baseline $PaO_2$ for the PLV was $312{\pm}$ mmHg. This was significantly lower when decreased compared to the baseline $PaO_2$ for GV which was $504{\pm}81$ mmHg(p=0.001). During PLV, the $PaO_2$, was significantly higher at the high PEEP($452{\pm}38$ mmHg) and high $V_T$ ($461{\pm}53$ mmHg) phases compared with the baseline phase. However, it did not change significantly during the inverse I:E ratio or the high RR phases. (3) The $PaCO_2$ was significantly lower at high $V_T$ and RR phases for both the GV and PLV. During the PLV, $PaCO_2$ were significantly higher compared to the GV (p<0.05). (4) There were no important or significant changes in of baseline and high RR phases lung mechanics and hemodynamics parameters during the PLV. Conclusion: During PLV in the normal lung, adequate $V_T$ and PEEP are important for optimal oxygenation.

Physiologic Changes During Bronchoscopy in Mechanically Ventilated Patients (기계환기중인 환자에서 기관지내시경 검사에 따른 생리적 변화)

  • Pyun, Yu Jang;Suh, Gee Young;Koh, Won-Jung;Yu, Chang-Min;Jeon, Kyeongman;Jeon, Ik Soo;Ham, Hyoung Suk;Kang, Eun Hae;Chung, Man Pyo;Kim, Hojoong;Kown, O Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.5
    • /
    • pp.523-531
    • /
    • 2004
  • Background : Bronchoscopy in patients on mechanical ventilation is being performed much more frequently. However, there is little data on the changes in physiologic parameters and no established mechanical ventilation protocol during bronchoscopy. A decreasing or the removal of positive end-expiratory pressure (PEEP) during bronchoscopy may precipitate severe hypoxemia and/or derecruitment. Methods : Our standardized mechanical ventilation protocol, without changing the PEEP level, was used during bronchoscopy. The physiological parameters were measured during the bronchoscopic procedure. Results : During bronchoscopy, respiratory acidosis, elevation of peak pressure, elevation of heart rate and auto-PEEP were developed, but were reversible changes. Procedure-related gross barotraumas or other severe complications did not developed. Conclusion : No serious complications developed during bronchoscopy under our standardized mechanical ventilation protocol when the PEEP level remained unchanged. The procedure time should be kept to a minimum to decrease the exposure time to undesirable physiological changes.