• 제목/요약/키워드: Pullout strength

검색결과 187건 처리시간 0.019초

Effect of high temperatures on local bond-slip behavior between rebars and UHPC

  • Tang, Chao-Wei
    • Structural Engineering and Mechanics
    • /
    • 제81권2호
    • /
    • pp.163-178
    • /
    • 2022
  • This paper aimed to study the local bond-slip behavior between ultra-high-performance concrete (UHPC) and a reinforcing bar after exposure to high temperatures. A series of pull-out tests were carried out on cubic specimens of size 150×150×150 mm with deformed steel bar embedded for a fixed length of three times the diameter of the tested deformed bar. The experimental results of the bond stress-slip relationship were compared with the Euro-International Concrete Committee (CEB-Comite Euro-International du Beton)-International Federation for Prestressing (FIP-Federation Internationale de la Precontrainte) Model Code and with prediction models found in the literature. In addition, based on the test results, an empirical model of the bond stress-slip relationship was proposed. The evaluation and comparison results showed that the modified CEB-FIP Model code 2010 proposed by Aslani and Samali for the local bond stress-slip relationship for UHPC after exposure to high temperatures was more conservative. In contrast, for both room temperature and after exposure to high temperatures, the modified CEB-FIP Model Code 2010 local bond stress-slip model for UHPC proposed in this study was able to predict the test results with reasonable accuracy.

Finite Elerllent Analysis of the Pull-out Test

  • Yi, Chang-Tok
    • 한국지반공학회지:지반
    • /
    • 제12권3호
    • /
    • pp.49-62
    • /
    • 1996
  • 인발시험은 보강토 구조물의 설계에 있어 보강재와 흙사이의 강도 정수를 결정하는데 사용된다. 그러나 이 시험의 해석시 보강재를 따라 발생하는 전단강도가 일정한 것으로 가정하는데 이는 인발시험중 흙과 보강재 사이의 점진성 전단으로 인해 흙과 보강재의 전단-변위 관계 계산시 오류가 발생하게 된다. 구과 보강재 사이의 shear stiffness계산시 점진성전단의 영향을 평가하기 위하여 유한요소법으로 인발시헙을 해석하였다. 흙과 보강재는 선형과 비선형거동으로 채석하였고 shear stiffnss는 일반적인 방법으로 계산하였는데 수정된 shear stiffness와는 많은 차이가 있었으며 그 차이로 인해 유한요소해석의 결과가 달라지게 된다. 본 논문에서는 유한요소해석결과와 시험치를 비교 분석하였으며 개선된 인발시험 해극방법에 대하여 논하였다.

  • PDF

반복재하 실물대 실험에 의한 컬럼-트리(Column-Tree) 형식 철골 모멘트 접합부의 내진거동 연구 (Cyclic Seismic Testing of Full-Scale Column-Tree Type Steel Moment Connections)

  • 이철호;박종원
    • 한국강구조학회 논문집
    • /
    • 제10권4호통권37호
    • /
    • pp.629-639
    • /
    • 1998
  • 본 연구에서는 반복재하 실물대 실험에 의해 철골 모멘트접합부(column-tree 형식)의 내진거동을 평가하였다. 시험체는 $H-600{\times}200$ (보) 및 $H-400{\times}400$ (기둥) 계열의 SS41 (SS400) 압연형강으로 제작되었으며 보에 대한 패널존의 상대강도를 실험의 주요변수로 고려하였다. 본 실험결과에 의할 때 패널존의 강도가 클수록 열등한 내진성능을 보였다. 시험체의 모멘트 접합부에서 접합부의 파괴 이전까지 발휘된 총소성회전각은 1.8 (% rad)에서 3 (% rad) 범위에 있었다. 시험체의 접합부는 보플랜지 열영향부의 파단 또는 기둥플랜지 두께방향의 뽑힘으로 인하여 파괴되었다. 비록 제한된 실험자료이긴 하나 본 연구의 결과는 보에만 항복을 유발하는 것 보다는 패널존의 항복도 허용하는 것이 접합부의 전체적 소성변형능력을 높이는데 유리할 것임을 시사한다. 이러한 실험결과를 역학적으로 설명할 수 있는 모델도 제시하고자 하였다.

  • PDF

GFRP 보강근의 부착응력-미끄럼 모델 (Local Bond Stress-Slip Model of GFRP Rebars)

  • 정연걸;이종구;이정윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.133-136
    • /
    • 2008
  • 염해에 노출이 심한 구조물이나 교량의 상판의 보강철근 부식으로 인한 콘크리트 구조물의 구조성능 및 내구성능의 저하가 큰 문제로 대두되고 있다. 이에 최근 활발히 연구가 진행 중인 유리섬유 보강근(Glass Fiber Reinforced Polymer Bar, 이하 GFRP 보강근)은 높은 화학적 내구성, 고강도, 경량성 등에 의하여 철근을 대체할 콘크리트 보강재로 그 가치를 인정받아 미국, 유럽, 캐나다 등에서는 이미 GFRP 보강근의 설계지침서가 발표되었다. 하지만 아직 GFRP 보강근을 이형철근과 같이 높은 신뢰성을 가지는 보강재로 사용하기에는 파악해야할 구조적 문제가 많이 있는데 그 중 하나가 콘크리트와의 부착성능이다. GFRP 보강근의 부착성능은 콘크리트 압축강도에 크게 영향을 받는 이형철근과 달리 섬유종류, 외피 표면 상태 등 여러 가지 요소에 의한 복합적 영향을 받는 부착특성을 보인다. 이에 본 연구에서는 외피 표면 상태, 콘크리트 압축강도 등을 변수로 하는 GFRP 보강근으로 보강된 일 방향 인장-인발 시편의 부착실험을 통하여 GFRP 보강근의 부착특성을 관찰하였다. 또한 이를 통하여 단조하중을 받는 GFRP 보강근의 부착응력-미끄럼 관계를 제안하고자 한다.

  • PDF

Development of a retrofit anchor system for remodeling of building exteriors

  • Yeun, Kyu Won;Hong, Ki Nam;Kim, Jong
    • Structural Engineering and Mechanics
    • /
    • 제44권6호
    • /
    • pp.839-856
    • /
    • 2012
  • To enable remodeling of the exterior of buildings more convenient, such finishing materials as curtain walls, metal panels, concrete panels or dry stones need to be easily detached. In this respect, this study proposed a new design of the slab for the purposes. In the new design, the sides of the slab were properly modified, and the capabilities of anchors fixed in the modified slab were experimentally tested. In details, a number of concrete specimens with different sizes and compressive strengths were prepared, and the effect of anchors with different diameters and embedment depths applied in the concrete specimens were tested. The test results of the maximum capacities of the anchors were compared with the number of current design codes and the stress distribution was identified. This study found that the embedment depth specified in the current design code (ACI318-08) should be revised to be more than 1.5 times the edge distance. However, with the steel sheet reinforcement, the experiment acquired higher tensile strength than the design code proposed. In addition, for two types of specimens in the tensile strength experiment, the current design code (ACI 318-08) is overestimated for the anchor depth of 75 mm. This study demonstrated that the ideal breakout failure was attainable for the side slot details of a slab with more than 180 mm of a slab thickness and less than 75 mm of an anchor embedment depth. It is expected that these details of the modified slab can be specified in the upgraded construction design codes.

가압 그라우팅 쏘일네일링 공법의 인발거동 특성 (Pull-out Characteristics of Multi-Packer Pressurized Soil Nails)

  • 조재연;이성준;정상섬;안병흔
    • 한국지반공학회논문집
    • /
    • 제26권2호
    • /
    • pp.15-22
    • /
    • 2010
  • 본 연구에서는 현장 인발시험을 통하여 강관다단 가압식 쏘일네일링의 거동특성을 분석하였다. 이를 위하여 총 10공의 쏘일네일을 풍화토에 시공하여 인발시험을 실시하였다. 인발시험 결과에 의하면 쏘일네일의 극한인발력은 가압식 쏘일네일이 중력식 쏘일네일에 비하여 42~142% 증가하는 것으로 나타났다. 네일과 주변지반 경계면에서의 전단강도는 중력식 네일이 71kPa, 가압식 네일이 95~166kPa를 보이는 것으로 확인되었다. 가압식 쏘일네일의 경우 중력식 쏘일네일에 비하여 그라우트의 직경이 약 12~27% 증가하는 것으로 나타났다. 또한, 공팽창이론에 의한 가압 시 지반변위 산정값과 현장 인발시험을 통하여 측정한 값을 비교하였으며, 그 결과는 대체적으로 비슷한 경향을 보였다.

이형 GFRP 보강근의 기본정착길이에 대한 연구 (A Study on the Basic Development Length of GFRP Rebar With Ribs)

  • 문도영
    • 대한토목학회논문집
    • /
    • 제30권5A호
    • /
    • pp.485-493
    • /
    • 2010
  • 국내에서 개발된 이형 GFRP 보강근은 표면에 구축된 이형의 전단강도가 콘크리트의 전단강도 보다 상대적으로 작아 이형철근과 달리 이형 자체가 전단파괴되는 파괴모드를 보이는 것으로 확인된바 있다. 본 논문에서는 이형을 갖는 GFRP 보강근의 기본정착길이를 인발실험과 설계모델식과 해석적 엄밀식을 통해 고찰하였다. 실험결과, 동일조건하에서 파괴모드가 변화되는 임계정착길이가 이형철근은 직경의 15배, 이형 GFRP 보강근은 20배인 것으로 나타났다. 또한 실험결과를 ACI440.1R-03 설계모델식에 적용하여 분석한 결과, 충분한 횡구속이 수반된 경우 직경 9 mm의 이형 GFRP 보강근의 기본정착길이는 직경의 21배인 것으로 나타났다. 반면, ACI440.1R-06에 제시된 기본정착길이 모델은 실험결과에 비하여 너무 과대한 기본정착길이를 요구하는 것으로 나타났다. Cosenza 등(2002)의 모델은 실험결과에 비하여 더 적은 기본 정착길이를 요구하므로, 설계목적의 사용은 제한적인 것으로 판단되었다.

긴장력이 도입된 콘크리트 충전 강관말뚝을 사용한 복합말뚝의 수평거동 특성 (Lateral Behavior of Hybrid Composite Piles Using Prestressed Concrete Filled Steel Tube Piles)

  • 박노원;백규호
    • 한국지반공학회논문집
    • /
    • 제34권12호
    • /
    • pp.133-143
    • /
    • 2018
  • 수평하중에 대한 말뚝의 휨강도를 증대시키기 위해 얇은 두께의 강관 내부에 PHC말뚝을 합성한 콘크리트 충전 강관(PCFT)말뚝이 개발되었다. PCFT말뚝의 휨강도를 강관말뚝과 비교하기 위하여 직경이 동일한 PCFT말뚝과 강관 말뚝에 대해 휨강도시험을 수행함과 동시에 한계상태설계법으로 P-M 상관도를 작도하였다. 그리고 PCFT말뚝의 하단에 PHC말뚝을 연결한 PCFT 복합말뚝의 수평지지력과 수평거동을 기존의 강관 복합말뚝(HCP) 및 강관말뚝과 비교하기 위하여 총 4본의 시험말뚝을 시공하고 수평재하시험을 수행하였다. 휨강도시험 결과 PCFT말뚝의 휨강도는 두께 12mm의 강관말뚝보다 18.7% 향상되었고, 동일한 휨하중에서 말뚝의 변위량은 강관말뚝보다 50% 감소하였다. 그리고 P-M 상관도로부터 연직하중을 받는 PCFT말뚝은 강관말뚝보다 휨내력이 크게 증가한 반면, 인발하중을 받는 PCFT 말뚝은 강관말뚝보다 휨내력이 감소함을 알 수 있었다. 또한 시험말뚝에 대한 수평재하시험의 결과에 따르면 상부말뚝의 길이가 동일한 경우 PCFT 복합말뚝은 HCP보다 수평지지력이 60.5% 컸고, 두께가 12mm인 강관말뚝보다 35.8% 큰 것으로 나타났다.

고유동 자기충전 콘크리트와 이형철근의 부착특성 (The Bond Characteristics of Deformed Bars in High Flowing Self-Compacting Concrete)

  • 최연왕;정재권;김경환;안태호
    • 대한토목학회논문집
    • /
    • 제29권5A호
    • /
    • pp.511-518
    • /
    • 2009
  • 본 연구에서는 콘크리트와 철근과의 부착강도에 영향을 미치는 요인 중 철근의 위치를 수평하부철근(Horizontal reinforcement at Bottom position, HB), 수평상부철근(Horizontal reinforcement at Top position, HT), 및 수직철근(Vertical reinforcement type, V)으로 변화시킨 시험체를 제작하여 3수준의 콘크리트 강도 변화(30, 50 및 70 MPa)에 따른 고유동 자기충전 콘크리트(High flowing Self-compacting Concrete, HSCC) 및 일반콘크리트(Conventional Concrete, CC)와 이형철근의 부착 특성을 비교 분석 하였다. HSCC 및 CC의 상부근 철근계수를 평가하기 위하여 HB/HT 철근의 부착강도비를 측정한 결과 50 및 70 MPa의 경우 HB/HT의 부착강도비는 1.3이하로 나타났으며, 30 MPa의 경우 HSCC 및 CC에서 각각 1.2 및 2.1로 나타났다. 따라서 HSCC 30, 50 및 70 MPa의 경우 콘크리트구조설계기준(2007) 정착길이 설계시 상부근 계수에 제시되는 수평상부철근에 대한 정착길이 보정계수를 CC의 1.3보다는 감소시켜 적용하는 것이 바람직할 것으로 판단된다.

가압 그라우팅 쏘일네일링의 인발저항력 증가 원인에 관한 연구 (A Study on Pullout-Resistance Increase in Soil Nailing due to Pressurized Grouting)

  • 정경한;박성원;최항석;이충원;이인모
    • 한국지반공학회논문집
    • /
    • 제24권4호
    • /
    • pp.101-114
    • /
    • 2008
  • 압력식 그라우팅은 지반 보강의 대표적인 공법 중 하나이며, 최근에는 사면 안정 공법으로 널리 사용되는 쏘일네일링에도 적용되고 있다. 그러나 가압 그라우팅 쏘일네일링 공법은 가압에 따른 그라우트와 지반 사이의 메커니즘이 매우 복잡하여 대부분 경험적인 설계가 이루어지고 있는 실정이다. 본 연구는 가압 그라우팅 쏘일네일링의 실내 모형실험, 현장시험 및 수치모델의 분석을 통해 그라우트와 주변 지반의 상호 거동을 평가하고, 이를 통해 인발저항력을 발휘하는 원인을 고찰하는데 그 목적이 있다. 실내 모형실험은 화강풍화토에 대해 수행하였으며, 그라우트 가압에 따라 초기에는 membrane 모델과 같이 공벽에 큰 압력이 작용하였으나, 점차 그라우트 내의 물이 주변지반으로 침투하면서 잔류응력까지 감소하는 것을 확인하였다. 이 때, 주입초기에 50%였던 물-시멘트비는 약 30%까지 감소하였으며, 이를 통한 그라우트의 강성 증가로 변위회복의 감소 및 주입압의 약 20%에 해당하는 잔류응력이 확인되었다. 또한 가압시 발생 변위를 측정하여, 그 값을 공팽창이론에 의한 값과 비교하였으며 그 결과는 대체적으로 일치하였다. 현장 시험 역시 풍화토에서 수행되었으며, 가압 그라우팅 쏘일네일링의 인발저항력이 중력식보다 약 36% 더 큰 것으로 나타났다. 이는 유효경 증가효과 약 24%, 기타, 잔류응력 및 구근 거칠기 증가 효과 약 10%에 기인함을 알 수 있었다.