• 제목/요약/키워드: Public Office Buildings

검색결과 101건 처리시간 0.025초

Empirical Analysis of Man-hour Data to Support a Cost-Plus Pricing Approach for Estimating BIM Service Costs

  • Koo, Bonsang;Lee, Ghang;Kim, Chung-woon;Shin, Byungjin
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.660-661
    • /
    • 2015
  • Building Information Modeling (BIM) is a nascent technology in Korea, and currently lacks formal guidelines to assist Architectural and Engineering (AE) firms in estimating BIM service fees, while also allowing government agencies to allocate budgets for the rendered BIM services. This research provides a method to estimate costs for BIM services based on the cost-plus pricing framework. The approach requires a generalized estimate of the man hour per floor area data to calculate the direct labor costs. Man-hour data were collected from forty five projects that have implemented BIM. Interpolation of the man-hours was performed to develop a general reference table for 'Type 2' (i.e., public schools and office buildings, etc.) projects. By providing an objective approach for estimating the costs of BIM services, it allows clients and AE firms to agree upon a fair cost for BIM related services, and thus expedite its adoption in Korea.

  • PDF

The Albizzia Tower

  • Mathurin Harde;Cyrille Le Bihan;Leonardo Gambatesa;Antoine Bauge
    • 국제초고층학회논문집
    • /
    • 제13권2호
    • /
    • pp.187-194
    • /
    • 2024
  • The 53-meter tall Albizzia Tower is a white, mineral building with a mixed concrete and wood structure. It harmoniously interacts with the high rises of La Confluence. Its base is largely open, in direct relation to the public space. The spaces are mutable, reversible, moldable thanks to a streamlined structure: posts, beams in glued laminated wood, with posts pushed back on the facade to facilitate the layout of office and housing floors, CLT floors with a span of 7 meters.

Development of Impact Table and optimum combination dedication module for green-remodeling advance business value assessment

  • Choi, Jun-Woo;Kim, Gyoung-Rok;Ko, Jung-Lim;Shin, Jee-Woong;Lee, Keon-Ho
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.5-12
    • /
    • 2016
  • Purpose: In case of existing building, A lot of attempts are being made like changing thermal system or using high efficiency products to decrease energy load and increase energy efficiency. However, (1) Absence of systemed database of green-remodeling technology and products. (2) Absence of comparative analysis system and qualitative/quantitative evaluation method of energy performance and energy reduction cost. (3) Existing remodeling was very hard to access for non-experts. So, in this paper, the authors developed data base for green-remodeling(Impact Table A, Impact Table B) and optimum combination dedication tool for user convenience. Accordingly, purpose of this paper validate usefulness of Impact Table and optimum alternative dedication tool. Method: For validate the usefulness of Impact Table and optimum combination dedication tool, the authors selected five test model office buildings. Next, through research investigation, the authors diagnosed the present state of buildings. In base of diagnosis results, select technologies for remodeling by qualitative comparison (Impact Table A). Next, evaluate quantitative price and performance technologies that selected in Impact Table A (Impact Table B). Lastly, through final evaluation of Impact Taba A and Impact Table B, determine the direction of the green-remodeling. Result: Impact Table and optimum combination dedication tool can use relative indicator for green-remodeling, especially through ROI by detail field.

국내 공공건축물 개방형 사무실 음환경 평가 (Evaluation of the acoustic environments of open-plan offices in Korean public buildings)

  • 박상희;신혜경;이승민;김경우
    • 한국음향학회지
    • /
    • 제42권1호
    • /
    • pp.42-49
    • /
    • 2023
  • 열악한 실내 음환경은 재실자에게 부정적인 영향을 미친다. 선행 연구를 통해 실내 음환경이 재실자의 과업성취도나 직무만족도뿐 아니라 그들의 건강과 웰빙에도 영향을 주는 것으로 알려져왔다. 본 연구는 국내 공공건축물에 위치한 개방형 사무실의 실내 음환경을 평가하고, 재실자의 음환경 쾌적성 향상을 위하여 고려할 필요가 있는 사항을 검토하기 위한 목적으로 수행되었다. 국내 공공건축물에 위치한 13개의 개방형 사무실에서 실내 소음 레벨을 측정하였으며, 측정은 월요일부터 금요일까지 5일간 진행되었다. 측정된 실내 소음 레벨은 ISO 및 EU ALDREN 프로젝트가 개방형 사무실을 대상으로 권장하는 수준을 기반으로 평가하였다. 분석 결과, 근무 시간 동안 재실자가 있는 환경에서의 실내 소음 레벨은 대부분 ISO 기준을 충족하는 것으로 나타났다. 재실자가 없는 심야 시간대의 음환경을 평가한 결과, 3개 사무실의 측정 결과값이 ALDREN의 권장 수준을 충족하지 못하는 것으로 나타났다. 아울러 측정이 진행된 현장의 특성이 실내 소음도에 유의미한 영향을 주는 것으로 나타났다. 건물 외피의 정확한 음향 성능을 파악하는 것이 불가능하였으므로 향후 추가 연구를 통해 건물의 성능과 실내 음환경 간 관계를 규명할 필요가 있다.

치과위생사의 직무환경이 건강자각증상에 미치는 영향 (Impact of working environment on the subjective health symptoms in the dental hygienists)

  • 정가영;조혜은
    • 한국치위생학회지
    • /
    • 제15권3호
    • /
    • pp.539-546
    • /
    • 2015
  • Objectives: The purpose of the study is to investigate the impact of working environment on the subjective health symptoms in the dental hygienists. Methods: The subjects were 220 dental hygienists in Gwangju and Jeonnam. A self-reported questionnaire was completed from September 9 to 22, 2012. The questionnaire was adapted and modified from building symptom index of workers in large buildings by O. The questionnaire consisted of eight questions of the general characteristics of the subjects, 19 questions of working environment and job satisfaction, nine questions of working environment characteristics, and six questions of subjective health symptoms. The questionnaire was measured by Likert 4 scale. Cronbach's alpha in this study was 0.826. Except incomplete answers, 192 data were analyzed using SPSS 19.0 program including t-test, ANOVA, and multiple regression. Results: The health symptoms were statistically and significantly different in glasses wearer and contact lens wearer, working hour satisfaction, and indoor environment(p<0.05). The subjective health symptoms were statistically different from the salary satisfaction, human relations satisfaction, office air environment, indoor environmental awareness score(p<0.05). Conclusions: It is necessary to improve the pleasant indoor working environment by providing the efficient working environment for the health care providers.

도시화에 따른 건조환경이 하절기 광주시 외부공간의 열환경에 미치는 영향에 대한 연구 (The Impacts of Built Environmental Features on the Land Surface Temperatures for the Heat Wave Seasons in Gwangju, South Korea)

  • 홍성운;양동우;오병철
    • 한국태양에너지학회 논문집
    • /
    • 제39권6호
    • /
    • pp.67-82
    • /
    • 2019
  • This study aims to examine the impacts of built environmental features on the nocturnal and diurnal temperatures during the heat wave season in Gwangju, Korea. Built environmental measures are summarized at micro-scale level, such as 50 meters and 100 meters from temperature monitoring spots. Regressing the built environment on nocturnal and diurnal temperatures, we estimate how the artificial constructs contribute to temperature either day and night times. We found that impervious surface ratio is positively and negatively associated with nocturnal and diurnal temperatures, respectively. Buildings and structures tend to construct high thermal mass and absorb heat during day time and emit it for the night time. This property contributes to the nocturnal temperature model. On the other hand, urban areas with more vertical structure tend to block sun radiation more than rural, and it is more likely to find the negative relationship between impervious surface ratio and the diurnal temperatures.

Test and Integration of Location Sensors for Position Determination in a Pedestrian Navigation System

  • Retscher, Guenther;Thienelt, Michael
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 International Symposium on GPS/GNSS Vol.1
    • /
    • pp.251-256
    • /
    • 2006
  • In the work package 'Integrated Positioning' of the research project NAVIO (Pedestrian Navigation Systems in Combined Indoor/Outdoor Environements) we are dealing with the navigation and guidance of visitors of our University. Thereby start points are public transport stops in the surroundings of the Vienna University of Technology and the user of the system should be guided to certain office rooms or persons. For the position determination of the user different location sensors are employed, i.e., for outdoor positioning GPS and dead reckoning sensors such as a digital compass and gyro for heading determination and accelerometers for the determination of the travelled distance as well as a barometric pressure sensor for altitude determination and for indoor areas location determination using WiFi fingerprinting. All sensors and positioning methods are combined and integrated using a Kalman filter approach. Then an optimal estimate of the current location of the user is obtained using the filter. To perform an adequate weighting of the sensors in the stochastic filter model, the sensor characteristics and their performance was investigated in several tests. The tests were performed in different environments either with free satellite visibility or in urban canyons as well as inside of buildings. The tests have shown that it is possible to determine the user's location continuously with the required precision and that the selected sensors provide a good performance and high reliability. Selected tests results and our approach will be presented in the paper.

  • PDF

학교시설 디자인 품질지표에 대한 설문 연구 - 교사, 학교직원, 교육청담당자를 중심으로 - (A Study on Survey Research Design Quality Indicators for the Educational Building - Focused on Teachers, School Personnel and Education Office Supervisor -)

  • 조경식;아이게림
    • 교육시설 논문지
    • /
    • 제25권5호
    • /
    • pp.3-12
    • /
    • 2018
  • The purpose of this study is to examine the degree of appropriateness of using design quality indicators for the educational building, and complements for design quality indicators. For doing this, each items of the Korean educational building design indicator was validated by teachers, school staff and an education officer. First, School Personnel and Teachers considered indicators for the classroom designed for general subjects as being valid. However, in terms of indicators for the outside space, they thought of them as not being valid. In particular, it seemed that school staff would have a passive attitude toward the open of the school facility for the local society. It is judged that there happens an adverse effect caused by the open of the school facility for the local society in the educational environment of the school. Second, Education Office Supervisors thought that eco-friendly indicators, LED lighting, an outer wall, and widows and doors had a high validity. On the contrary, he viewed the validity of a rainwater retention basin as being low, which was likely because he rarely had expertise on the construction. When it comes to the indicator of technology capability, ultrahigh-speed information network was seen as being valid, and the indicator of economic feasibility had high validity on maintenance and durability. Third, compared to groups of Teachers and School Personnel, the group of education officers presented high validity of indicators. Validity of indicators might be differently showed because different items on indicators were measured. However, it is speculated that Education Office Supervisors mostly acknowledged the validity of indicators. Fourth, a majority of Teachers, School staff, and Education Office Supervisors were favor of the system of the evaluation accreditation for school facilities since it played a guide role in improving the quality of school. In order to settle the system of the evaluation accreditation for school facilities, it is most important that institutions in the local society which are publicly reliable should participate in the phase of designing the system of the evaluation accreditation for school facilities. In sum, overall respondents agreed with the system of the evaluation accreditation for school facilities but were aware that reliable organizations in public would need to take part in planning the system of the evaluation accreditation for school facilities from the beginning.

Case Studies on Space Zoning and Passive Façade Strategies for Green Laboratories

  • Kim, Jinho
    • Architectural research
    • /
    • 제22권2호
    • /
    • pp.41-52
    • /
    • 2020
  • Laboratory buildings with specialized equipment and ventilation systems pose challenges in terms of efficient energy use and initial construction costs. Additionally, lab spaces should have flexible and efficient layouts and provide a comfortable indoor research environment. Therefore, this study aims to identify the correlation between the facade of a building and its interior layout from case studies of energy-efficient research labs and to propose passive energy design strategies for the establishment of an optimal research environment. The case studies in this paper were selected from the American Institute of Architects Committee on the Environment Top Ten Projects and Leadership in Energy and Environmental Design (LEED) certified research lab projects. In this paper, the passive design strategies of space zoning, façade design devices to control heating and cooling loads were analyzed. Additionally, the relationships between these strategies and the interior lab layouts, lab support spaces, offices, and circulation areas were examined. The following four conclusions were drawn from the analysis of various cases: 1) space zoning for grouping areas with similar energy requirements is performed to concentrate similar heating and cooling demands to simplify the HVAC loads. 2) Public areas such as corridor, atrium, or courtyard can serve as buffer zones that employ passive solar design to minimize the mechanical energy load. 3) A balanced window-to-wall ratio (WWR), exterior shading devices, and natural ventilation systems are applied according to the space programming energy requirements to minimize the dependence on mechanical service. 4) Lastly, typical laboratory space zoning categories can be revised, reversed, and even reconfigured to minimize the energy load and adjust to the site context. This study can provide deep insights into various design strategies employed for construction of green laboratories along with intuitive arrangement of various building components such as laboratory spaces, lab support spaces, office spaces, and common public areas. The key findings of this study can contribute towards creating improved designs of laboratory facilities with reduced carbon footprint and greenhouse emissions.

인공신경망 기반의 공공청사 공사비 예산 예측모델 개발 연구 (A Study on the Development of Construction Budget Estimating Model for Public Office Buildings based on Artificial Neural Network)

  • 김현진;김한수
    • 한국건설관리학회논문집
    • /
    • 제24권5호
    • /
    • pp.22-34
    • /
    • 2023
  • 건설사업의 사업초기단계에 산정되는 공사비 예산을 적절히 예측하는 것은 발주자의 올바른 의사결정을 지원하고 건설사업의 목표를 달성하기 위해 매우 중요한 현안이다. 이는 공공 건설사업의 경우에서도 마찬가지이다. 그러나 현재 공공 건설사업의 사업초기단계에서 수행되는 공사비 예산의 예측방식은 정확성 및 신뢰성 관점에서 정교하지 못해 이에 대한 개선의 필요성이 제기되고 있다. 본 연구의 목적은 인공신경망을 활용하여 공공청사 프로젝트 사업초기단계에서 활용할 수 있는 공사비 예산 예측모델을 개발하는데 있다. 본 연구에서는 조달청에서 제공하는 데이터와 SPSS Statistics 프로그램을 활용하여 인공신경망 모델을 구축하였으며, 공사비 예산 예측의 수준을 분석하고 추가 검증을 통해 모델의 정확성을 검증하였다. 검증 결과, 개발된 인공신경망 모델은 사업초기 단계에서 활용할 수 있는 견적의 오차범위를 보여주었으며 이를 통해 다양한 프로젝트 조건(변수)을 활용하여 보다 정교하게 공사비 예산을 예측할 수 있는 가능성을 시사하였다.