• 제목/요약/키워드: Psychrometric chart

검색결과 11건 처리시간 0.022초

습공기선도 상에 20 종류의 상태 및 과정 값의 작도 (Drawing of Twenty Kinds of State and Process on Psychrometric Chart)

  • 김덕진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1201-1206
    • /
    • 2008
  • Psychrometric chart displays graphically the thermophysical properties of moist air, so it is very conveniently used in air-conditioning and refrigeration. On general psychrometric chart, there are dry bulb temperature, web bulb temperature, absolute humidity ratio, relative humidity, specific enthalpy, specific volume, sensible heat factor, and enthalpy-humidity difference ratio. However, various state and process values besides aboves can be plotted on psychrometric chart. In this study, we developed the software drawing twenty kinds of lines, that is vapor pressure, mole fraction ratio of vapor, dew point temperature, degree of saturation, density, specific entropy, specific exergy, contact or bypass factor, uncomfort index, discomposition index, predicted mean vote index, predicted percent dissatisfied, and so on. We wish to this software is a help to design, analysis and education.

  • PDF

실내 습도 증가를 이용한 무재열 냉방시스템 개선에 관한 연구 (A Study on the Improvement of a Cooling System by the Increment of Room Humidity without Reheating Process)

  • 이홍주;김용구
    • 대한설비공학회지:설비저널
    • /
    • 제16권6호
    • /
    • pp.613-619
    • /
    • 1987
  • In a room air conditioning cooling system, if the room-sensible-heat-factor as plotted on a Psychrometric Chart intersects the saturation curve below the apparatus leaving air dewpoint, reheat must be used to maintain the design room air conditions. However, if the design room humidity is permitted to be raised to some degree, the cooling system will not require reheat as a new room-sensible-heat-factor line is developed between the apparatus leaving air dew-Point and the adjusted design room air conddition point. The advantages to this are the cost of reheat equipment and operation can be avoided. The cycle of this system can be shown on a Psychrometric Chart to plot the design condition points.

  • PDF

A Study on Pattern Recognition to Compute Guidelines Based on Evidence for Ecological Healing Environment at Agha Khan Hospital in Karachi - Focused on Human Thermal Comfort Model (HTCM), for Karachi, using Climate Consultant Program

  • Shaikh, Javaria Manzoor;Park, Jae Seung
    • KIEAE Journal
    • /
    • 제15권2호
    • /
    • pp.27-35
    • /
    • 2015
  • Purpose: Healthcare is on the whole a personal and critical service that consumer's use, whereas hospitalization is as a rule painful, because nature nurtures and Sun Light Luminosity for healthcare settings is considered healing. The performance and design of climate responsive buildings such as AKU requires a detailed study of attributes of climate both at micro as well as macro level. The therapeutic value of contact with nature through window view, greenery and landscape is calculated there. Method: A two prong strategy is been devised for this article, at micro level three typical morphologies are analysed by creating same environment of neighboring building on sun shading chart, radiation and temperature range. Since the analysis of local climate helps to determine the design strategies for hospital Healing Environment which is suitable for Karachi climate; in order to track the macro climatic behaviour, a considerable analysis of psychometrics chart for AKU Karachi are designed on Climate Consultant (CC) and analysed by Machine Learning. Climate Consultant proposes different design strategies suitable for Karachi. And on the other hand time wise illumination sources for clinical area which are then measured on psychrometric chart- according to singular space: multi patient admission, secondly: acute ambulatory ward, and tertiary: multi windowed space according to the mushrabiyah and sky light pattern. Result: Our findings support the hypothesis that windowed wall is 75-80% more healing wall; an accelerated evidence was found for healing at macro level if the form of the hospital is designed according to the climatologically preferences, whereas at micro level: the light resource becomes the staff attentiveness determinant. In Conclusion evidence was provided that the actual form of luminosity results consequently in satisfaction while light entering from several set of windows and other sources might be valued if design according to the healing environment. The data added on the sun shading chart to calculate rays entraining into space in patient room equal to 124416.21 Watts/ meter $m^2$ is calculated as precise healing rate-and is confirmed by questionnaire from patients belonging from each clinical stage having different illnesses.

조도 변화에 따른 뇌파 기반 생체신호 변화에 관한 연구 (The Study about Variation of Physiology Signal based on EEG due to Variation of Illumination)

  • 김명호
    • 전기학회논문지P
    • /
    • 제61권1호
    • /
    • pp.55-58
    • /
    • 2012
  • By using EEG and HRV, subjects were estimated on their psychological and physiological reaction when reading psychrometric chart in 7 point century font, in an environmental test room in the condition of temperature 25[$^{\circ}C$], relative humidity 50[RH%], air current speed 0.02[m/sec], giving variation in illuminance to 0.1, 300, 600, 1000, 1300 and 1600[lux]. As a result, it was at 1300[lux] that absolute ${\alpha}$ wave, SMR, SDNN were most vitalized, and also both sides ${\alpha}$ wave asymmetry index, SEF50, HRT, stress and fatigue degree were at the lowest. It was found that a certain illuminance which minimizes psychological stress and fatigue degree while enhancing concentration and task achievement stably does exist.

이론적 방법에 의한 제습로터 최적 회전속도의 결정 (Theoretical Determination of Optimum Rotating Speed of Desiccant Rotor)

  • 송귀은;이대영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.603-608
    • /
    • 2008
  • A simple equation to find a optimum speed of desiccant rotor is presented in this theoretical study. Usually the determination of optimum speed of desiccant rotor requires tedious and lengthy procedures by solving governing differential equations with many complicated parameters. The determining equation of optimal rotating speed is derivated from governing differential equations with three linearization assumptions, which simplify temperature profile linear along the desiccant rotor depth, psychrometric chart within a proper range, and relative humidity-sorption capacity relation. This study shows that the dominant parameters of optimal rotating speed of desiccant rotor are NTU, flow velocity, desiccant rotor depth, and temperature different between dehumidification and regeneration. The comparison shows the good agreement between complicated calculation results and simple theoretical equation prediction.

  • PDF

제습로터의 운전특성을 재배하는 무차원 인자의 도출과 해석 (Derivation and Analysis of Dimensionless Parameters Dominating the Dehumidification Characteristics of a Desiccant Rotor)

  • 이길봉;김민수;이대영
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.611-619
    • /
    • 2005
  • In a previous work of the authors, the heat and mass transfer in a desiccant rotor was analyzed theoretically through linearization assumptions and four dimensionless parameter groups dominating the dehumidification process were arranged. In this work is verified whether the four dimensionless parameters also play the dominant roles in more realistic situations where the nonlinear factors affect the heat and mass transfer. The results show that the dehumidification characteristics are closely similar to each other as long as the four dimensionless parameters have the same set of values while the rotor configurations and/or the operation conditions are different from each other. The four dimensionless parameters are $\Psi,\;\chi,\;\sigma$ and N, where $\Psi$ implies the average gradient of relative humidity lines in the psychrometric chart, $\chi$ the heat capacity of the rotor and $\sigma$ the sorption capacity of the rotor, and N implies the number of transfer unit.

한국의 열감분포에 관한 생리 기후학적 연구 - 신유효온도를 중심으로 - (A Physioclimatic Study on the Thermal Sensation in Korea)

  • 강철성
    • 대한지리학회지
    • /
    • 제32권2호
    • /
    • pp.129-140
    • /
    • 1997
  • 본 논문에서는 인간 생리 및 생활에 가장 기본이 되는 온도, 상대습도를 기초로 하여 인간의 열긴장도를 측정하여 우리나라의 열감분포의 특성을 파악하였다. 연구 방법은 열지수 분석을 중심으로 하였다. 열지수는 습도계산도에서, 월별 열지수 및 연누적 열지수를 계산하여 한국의 연누적 열지수 분포도를 작성하였다. 연누적 열지수 분포의 분석 결과는 우리 나라의 대부분 지역이 한랭긴장도가 나타나는 지역이고 남쪽에서 북쪽으로, 해안에서 내륙으로 갈수록 한랭긴장도가 높아지고 있다. 특히 삼지연. 풍산, 장진을 중심으로 한 개마고원 지역이 높은 한랭긴장도 지역이고, 제주와 서귀포룰 포함한 제주도 지역이 가장 낮은 긴장도를 보이고 있다. 전자는 겨울에 시베리아 기단의 영향을 직접 받고. 고도가 매우 높은 내륙 산지 지역이기 때문이고, 후자는 위도와 바다의 영향으로 특히 겨울에 온화한 지역이기 때문이다.

  • PDF

가변용량 압축기를 적용한 에어컨의 냉방운전 시 응축 및 증발온도 특성 (Temperature characteristics of condenser and evaporator of Air-conditioner applying variable capacity compressor under cooling condition)

  • 권영철;전종균
    • 한국산학기술학회논문지
    • /
    • 제8권6호
    • /
    • pp.1325-1331
    • /
    • 2007
  • 본 연구에서는 냉방운전 시 가변용량방식의 압축기를 적용한 시스템 에어컨의 냉방능력과 증발기 및 응축기의 온도특성을 조사하기 위해 압축기 운전율(10가지)과 실내외 온도(16가지)의 변화에 따른 시스템의 운전특성을 실험적으로 조사하였다. 시스템의 운전특성은 칼로리미터를 이용하여 측정되었다. 냉방능력은 실외온도가 낮아질수록 실내온도가 증가할수록 더 큰 값을 그리고 압축기 운전율이 증가할수록 냉방능력은 선형적으로 증가하였다. 응축온도는 실외온도 변화에 증발온도는 실내온도 변화에 더 민감하였다. 또한 압력-엔탈피선도를 이용하여 사이클의 운전특성을 분석하였다.

  • PDF

기화방열식 Cool Roof Fan의 냉풍효과에 대한 연구 (A Study of the Cooling Effect of an Evaporation-Type Cool Roof Fan)

  • 김영식;정한식;정효민;최순호
    • 대한기계학회논문집B
    • /
    • 제40권3호
    • /
    • pp.191-200
    • /
    • 2016
  • 환기는 자연환기와 강제환기로 분류되며, 최근에는 하절기에 작업장의 환경개선을 위해 냉각된 공기를 공급하는 환기를 적용하는 경우가 많아지고 있다. 하지만 대규모의 작업장에 냉각된 공기를 공급하기 위해서는 많은 에너지가 필요하며, 이를 보완하기 위해 물의 증발열을 이용하여 공기를 냉각시킨 후 공급하는 환기장치의 도입사례가 증가하고 있으며, 본 실험연구는 부산의 모 신발공장에 실제 적용된 기화방열식 환기장치의 성능을 평가한 사례연구로서 하절기에 외부의 대기온도에 대해 어느 정도의 냉각능력을 구현할 수 있는지 측정하였다. 실험결과로부터 하절기에 약 $6{\sim}7^{\circ}C$ 정도의 냉각효과를 구현하지만 급기의 상대습도가 매우 높아짐을 정량적으로 측정할 수 있었다. 실험결과에 의하면 기화방열식 전체환기 설비가 타방식과 비교하여 작동방식이 단순하며, 에너지 소비가 적은 경제적인 냉각설비이며, 급기의 습도 제어기능만 부가되면 매우 효율적인 환기 - 냉각기능을 동시에 수행할 수 있는 설비임을 확인하였다.