• Title/Summary/Keyword: Proximal shape

Search Result 86, Processing Time 0.025 seconds

SHAPING ABILITY OF ROOT CANAL INSTRUMENTS ON CURVED ROOT CANALS (수종 근관확대 기구의 만곡된 치근관 성형능력)

  • Kim, Myeong-Su;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.1
    • /
    • pp.141-152
    • /
    • 1992
  • Four endodontic instruments from different manufacturers(K - file, Hedstrom - file, K - flex - file, Cavi - Endo) were used to shape 80 mesial canals of extracted posterior teeth. The instrument's ability to enlarge and shape the canals as the original canal shape was assessed by superimposing radiographs of canals obtained before and after canal shaping. The results were as follows 1. Hedstrom - file enlarged canals greater than K - file, K - flex - file, and Cavi - Endo(P<0.05). There are no differences in canal enlargement among K - flex, K - flex - file, and Cavi - Endo(P<0.05). 2. All the instruments showed no difference in canal enlargement between convex side and concave side of B point in proximal and clinical radiographic views, but at the concave side of C point canals were enlarged greater than at the convex side(proximal view of K - file: P<0.05, the others: P<0.01). 3. There was no difference m canal enlargement between convex side and concave side in proximal view of A and D points of K - file and K - flex - file(P<0.05). But in clinical view, canal enlargement at convex side of A point and concave side of D point was greater than that at concave side of A point and convex side of D point respectively. 4. Hedstrom - files showed greater canal enlargement at convex side of A points and concave side of D points (P<0.05 or P<0.01). Cavi - Endo showed no difference in canal enlargement between convex side and concave side at A and D points in proximal view(P<0.05). Bur canal enlargement was greater at concave side than at convex side of D point in clinical view. 5. K - file and Cavi - Endo showed no differences in canal enlargement between convex and concave side in proximal and clinical view (P<0.05). K - flex - file showed greater canal enlargement at concave side in proximal and clinical view(P<0.0:5). Hedstrom file showed no difference in canal enlargement between convex side and concave side in proximal view, but showed greater canal enlargement at concave side in clinical view(P<0.05).

  • PDF

Considerations for minimizing food impaction after implant prosthesis: Adjacent and antagonistic teeth (임플란트 보철 후의 식편압입을 최소화하기 위한 고려사항: 인접치와 대합치)

  • Lee-Ra, Cho
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.31 no.2
    • /
    • pp.47-55
    • /
    • 2022
  • Food impaction due to proximal space opening after implant restoration is a very common phenomenon in patients who have implant prosthesis. This occurs because the movement mechanism between the implant and the tooth is different, and it occurs about 30-60% over time. Contributing factors include the arch (mandible), region (posterior teeth), adjacent teeth (non-vital teeth), and antagonist teeth (natural teeth or implants), etc. While this phenomenon cannot be prevented, efforts should be made to minimize it. In order to have an ideal proximal contact as much as possible, the concave shape or the prominent lower proximal shape should be modified to create a symmetrical proximal shape. with the buccal dentate in the upper third height should be adjusted. Other conditions should be modified so that the heights of the marginal ridges are similar. Since an irregular occlusal plane is a cause of poor prognosis, food impaction should be minimized by restoring the ideal occlusal plane by correcting the extruded antagonist and reduction of the disto-buccal cusp.

EFFECT OF "STEP-DOWN" AND "BALANCED FORCE" PREPARATION METHODS ON THE SHAPE OF THE ROOT CANAL (Step-down과 Balanced force 근관성형술식에 의한 근관 형태의 변화)

  • Chin, Cheong-Hee;Kim, Jong-Hwa;Lee, Kwang-Won;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.768-779
    • /
    • 1995
  • This study was performed to investigate the effect of root canal shaping techniques on the change of the shape of prepared root canal. 40 mesiobuccal canals of recently extracted mandibular 1st and 2nd molars were divided into 4 groups and shaped by step-down/balanced force technique, step-down/step-back technique, step-back technique and conventional technique respectively. The change of the shape of root canal was traced by superimposing the radiographs obtained before and after shaping of each root canal. The results were as follows. 1. By the experimented techniques except conventional technique, the root canals were more shaped in convex side of apical area and in concave side of most curved and coronal area than in the other sides(P<0.05). By conventional technique, the root canals were more shaped in convex side than in convave side from apex to orifice(P<0.05). 2. By step-down/balanced force technique, the cancave sides at C and D points of proximal view and C point of clinical view were more shaped than the convex side(P<0.05). Through the entire canal, the concave side was more shaped than the convex side in proximal view(P<0.01). But there was no statistical difference between both sides in clinical view. 3. By step-down/step-back technique, the change of root canal shape was not statistically different in concave and convex sides at each point of both views(P>0.05). And through the entire canal in proximal view, there was no statistical difference in shaping percentage between both sides. But through the entire canal in clinical view, the concave side was more shaped than the convex side(P<0.1). 4. By step-back technique, the convex side at B point of clinical more shaped than the other sides(P<0.05). Through the entire canal in proximal and clinical views, there was no statistical difference in shaping percentage between both sides. 5. Comparing the total shaping percentage among techniques, that in conventional technique was the greatest numerically, and followed by the percentages in step-down/step-back, step-down/balanced force and step-back technique. But, in proximal view, shaping percentages were not statistically different among techniques(P>0.05, ANOVA test). In clinical view, shaping percentages in step-back and conventional techniques were statistically different(P<0.01, ANOVA test). * Proximal view: radiograph taken in mesiodistal direction. * Clincal view: radiograph taken in faciolingual direction. A point : 1mm point from radiographic apex B point : center point between A and C points C point : most curved point of root canal D point : center point between C point and canal oriffice.

  • PDF

Human Pose Matching Using Skeleton-type Active Shape Models (뼈대-구조 능동형태모델을 이용한 사람의 자세 정합)

  • Jang, Chang-Hyuk
    • Journal of KIISE:Software and Applications
    • /
    • v.36 no.12
    • /
    • pp.996-1008
    • /
    • 2009
  • This paper proposes a novel approach for the model-based pose matching of a human body using Active Shape Models. To improve the processing time of model creation and registration, we use a skeleton-type model instead of the conventional silhouette-based models. The skeleton model defines feature information that is used to match the human pose. Images used to make the model are for 600 human bodies, and the model has 17 landmarks which indicate the body junction and key features of a human pose. When applying primary Active Shape Models to the skeleton-type model in the matching process, a problem may occur in the proximal joints of the arm and leg due to the color variations on a human body and the insufficient information for the fore-rear directions of profile normals. This problem is solved by using the background subtraction information of a body region in the input image and adding a 4-directions feature of the profile normal in the proximal parts of the arm and leg. In the matching process, the maximum iteration is less than 30 times. As a result, the execution time is quite fast, and was observed to be less than 0.03 sec in an experiment.

Photoelastic Stress Analysis of the Abutment Surrounding Tissue According to Shape of the Proximal Plate of the RPI Clasp (압축하중시 RPI clasp의 3가지 다른 proximal plate 형태에 따른 지대치 주위조직의 광탄성 응력 분석)

  • Choi, Jung Soo;Kim, Busob
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.473-482
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the stress distribution of the surrounding tissues according to 3 proximal plate types of the RPI clasp. Methods: The removeable partial denture which mandibular right and left second premolars and mandibular molars were lost was attached to a three dimensional photo elastic epoxy resin model. Then 120N of vertical load was applied. After 3-dimensional photoelastic stress analysis was used to record the isochromatic fringe patterns. Results: Kratochvil type guiding plane exhibited little uniform stress distribution on load center and alveolar ridge, but higher stress concentration on buccal surface of second premolar. Krol type guiding plane exhibited the stress concentration on the front of load center and relatively higher stress concentration on buccal surface of first premolar. However, this type had no effect on canine. Researcher type guiding plane showed the stress concentration on second premolar and molar, but the little stress distribution on first premolar. Conclusion: In all types, excessive stress concentration was appeared and three types were not significant different.

3D finite element simulation of human proximal femoral fracture under quasi-static load

  • Hambli, Ridha
    • Advances in biomechanics and applications
    • /
    • v.1 no.1
    • /
    • pp.1-14
    • /
    • 2014
  • In this paper, a simple and accurate finite element model coupled to quasi-brittle damage law able to describe the multiple cracks initiation and their progressive propagation is developed in order to predict the complete force-displacement curve and the fracture pattern of human proximal femur under quasi-static load. The motivation of this work was to propose a simple and practical FE model with a good compromise between complexity and accuracy of the simulation considering a limited number of model parameters that can predict proximal femur fracture more accurately and physically than the fracture criteria based models. Different damage laws for cortical and trabecular bone are proposed based on experimental results to describe the inelastic damage accumulation under the excessive load. When the damage parameter reaches its critical value inside an element of the mesh, its stiffness matrix is set to zero leading to the redistribution of the stress state in the vicinity of the fractured zone (crack initiation). Once a crack is initiated, the propagation direction is simulated by the propagation of the broken elements of the mesh. To illustrate the potential of the proposed approach, the left femur of a male (age 61) previously investigated by Keyak and Falkinstein, 2003 (Model B: male, age 61) was simulated till complete fracture under one-legged stance quasi-static load. The proposed finite element model leads to more realistic and precise results concerning the shape of the force-displacement curve (yielding and fracturing) and the profile of the fractured edge.

Reconstruction of Metaphyseal Defect of Large Long Tubular Bone with Double Barreled Fibular Graft (중첩한 비골 이식술을 이용한 대형 장골의 골 간단부 결손의 재건)

  • Chung, Duke-Whan;Park, Jun-Young
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.1
    • /
    • pp.50-56
    • /
    • 2005
  • There are limited treatment options in the reconstruction of the very large defect in the metaphyseal portion of distal femur and proximal tibia. Fibula is one of the most popular donor of the long bone reconstruction in reconstructive microsurgical field. It has many advantages such as very strong strut tubular bone, very reliable vascular anatomy with large vascular diameter and long pedicle. There are limited donor site problems such as transient peroneal nerve dysfunction. In those situations with the huge long bone defects in distal femur or proximal tibia, the defective bony shape and strength of the transplanted fibular bone is not enough if only one strut of the fibula is transferred. We performed 7 cases of "doule barrel" fibular transplantation on the metaphyseal portion of distal femur and proximal tibial large defects in which it is very difficult to fill the bony gap with conventional bone graft or callotasis methods. It takes averaged 8.3 months since that procedure to obtain bony union. After solid union of the transferred double barrelled fibular graft. There were no stress fracture in our series. So we can propose double barrel fibular graft is useful method in those cases with very large bone defect on the metaphysis of large long bone.

  • PDF

Diagnostic Imaging of Urological Diseases in Dogs (개에서 비뇨기계 질환의 진단영상)

  • 장동우;정주현;장진회;정우조;원성준;이기창;최호정;이희천;윤화영
    • Journal of Veterinary Clinics
    • /
    • v.18 no.4
    • /
    • pp.459-464
    • /
    • 2001
  • Excretory urography is a procedure where opacification of the kidneys, renal pelvic diverticula, ureters, and urinary bladder is a result of renal excretion of an intravenously administered iodinated contrast agent providing both anatomical and functional assessment. And ultrasonography is a non-invasive modality to evaluate the important anatomic information concerning the size, shape, and internal architecture of kidney even in the presence of impaired renal function or abdominal fluid. We describe four dogs with urological signs diagnosed with excretory urography and ultrasonography. Parients showed a variety of clinical signs including vomiting, hematuria, anorexia, abdominal pain, and abdominal distension. The hydronephrosis was diagnosed in case 1, 2, and 3 that had pelvic dilation, dilation of pelvic recesses, ureteral dilation. In case 3, proximal ureteral rupture was diagnosed with evidence of contrast media leakage was seen in proximal ureter. In case 4, the rupture of urinary bladder was diagnosed with leakage of contrast media through its ventral portion.

  • PDF

Optimal Design of Stem Shape for Artificial Hip Prosthesis with Unbonded Cement Mantle (시멘트 비접착 인공 고관절의 주대 형상 최적 설계)

  • Choi, Don-Ok;Yoon, Yong-San
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.932-938
    • /
    • 2001
  • This study is concerned with the shape optimization of stem for the artificial hip prosthesis with unbonded cement mantle. The artificial hip prosthesis with unbonded cement mantle allows a stem to slip on cement mantle because of polished stem surface. Unbonded cement mantle type has several advantages compared with bonded cement mantle type, for example, small micro motion, preventing stress shielding and so on. In this study, 2-dimensional axisymmetric model was developed with considering characteristics of unbonded cement mantle. Moreover, optimal shape of stem was obtained by using feasible direction method. The objective of this optimization is maximizing supported vertical loading. The slip motion and stresses of stem, cement mantle and bone is used for constraints. The optimal shape which obtained by this study has slope of 0.15 in proximal part and maintains the width about 5mm in distal part In addition, simplified 3-dimensional analysis which applying optimal shape is carried out. The result of 3-dimensional analysis showed that optimal shape has some advantages for cement mantle stress. However, more realistic 3-dimensional analysis which including bending effect, complex geometries etc. is needed in further research.

  • PDF

Free Vascularized Fibular Transfer with Double Barrel Fashion (혈관부착 생비골 중첩 이식술)

  • Chung, Duke-Whan
    • Archives of Reconstructive Microsurgery
    • /
    • v.7 no.1
    • /
    • pp.54-61
    • /
    • 1998
  • Free vascularized fibular is the most usuful bony donor of the long bone reconstruction in reconstructive microsurgical field. It has many benifits such as very strong strut tubular bone, very reliable vascular anatomy with large vascular diameter with long pedicle, minimal donor site morbity too. In that situations of the huge long bone defects in distal femur or proximal tibia, the defective bony shape and strength of the transplanted fibular bone is not enough if only one strut of the fibula is transfered. The bony circulation of the fibula has two ways, one from nutrient artery via peroneal artery through nutrient foramen which makes endosteal arterial network inside of the fibula, another way is periosteal network through outside encircling vascular network of the bone which distributed in muscle sleeves of the fibular diaphysis. Authors modified free vascularized fibular bone graft with transverse osteotomy is made from the anterolateral aspect of the fibular shaft just distal to entry of the nutrient artery. This produces two vascularized bone struts that may be folded pararell to each other but that remain connected by the periosteum and muscle cuff surrounding the peroneal artery and veins. The proximal strut is vascularized by both a periosteal and endosteal blood supply, whereas the distal strut is vascularized by a periosteal blood supply alone. This procedure can call "doule barrel" free vascularized fibular graft. We performed 7 cases of doule barrel fashined fibular transplantation on distal femur and proximal tibial large defects. Average bone union time takes 7 months from that procedure. There were no significant bone union time differences between both proximal and distal struts. After solid union of the transfered double barrel fibular graft, there were no stress fracture in our series. We can propose double barrel free vascualized fibular graft is usuful method in that cases with very large bone defect on large long bones especially metaphyseal defects.

  • PDF