• Title/Summary/Keyword: Proximal humerus fractures

Search Result 51, Processing Time 0.025 seconds

Minimal Invasive Plate Osteosynthesis in Proximal Humerus Fractures (상완골 근위부 골절에서의 최소 침습적 금속판 술식)

  • Shin, Sang-Jin;Do, Nam-Hun;Song, Mi-Hyun;Sohn, Hoon-Sang
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.202-208
    • /
    • 2010
  • Purpose: In this study we introduced minimal invasive plate osteosynthesis (MIPO) and analyzed clinical outcomes to determine the effectiveness of this intervention in proximal humerus fractures. Materials and Methods: We studied 27 patients including 16 cases with a 2-part fracture, 10 cases with a 3-part fracture, and 1 case with a 4-part fracture. Clinical outcomes were evaluated using UCLA score, KSS score and recovery of range of motion. Time to union and humerus neck-shaft angle change were estimated by radiologic assessment. The average follow up period was 19 months. Results: UCLA scores were "excellent" for 15 patients, "good" for 12 patients. The mean KSS score was 91.4 at final follow-up. The average shoulder range of motion was $167.2^{\circ}$ in forward elevation. Bone union occurred by 14.1 weeks postoperatively. Humerus neck-shaft angle recovery was "excellent" in 24 patients and "moderate" in 3 patients. There were no complications such as axillary nerve paralysis, deep infection, or subacromial impingement of the plate. Conclusion: MIPO for proximal humerus fractures is an effective procedure if performed with sufficient understanding of the anatomical structures. MIPO leads to minimized dissection of soft tissue, low complication rates and early recovery of range of motion.

An Anterior Approach to Entire Length of Humerus and to Distal Shaft for Fracture Fixation

  • Lee, Chul-Hyung;Choi, Hyun;Kim, Tae-In;Kim, Jun Beom;Shin, Sang Yeop;Rhee, Seung-Koo
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.4
    • /
    • pp.223-228
    • /
    • 2016
  • Background: The aim of study was to confirm the clinical effectiveness and results of wide and single anterior approach for fractures occurring along length of humerus. Methods: A total of 23 patients with humeral fracture were enrolled into our study who were able to participate in at least one year of follow-up. Seven patients had segmental comminuted humeral fractures and 16 patients had distal humeral fractures. We made various tractions of the muscles to expose the proximal and the middle third humerus between the biceps and brachialis and the distal humerus by partial splitting of lateral side of biceps through a single incision. Postoperatively, we measured the Mayo elbow performance index (MEPI). Results: we achieved bone union in all 23 patients. Solid union of the bone was achieved at an average 13.9 weeks. Postoperatively, two complications were observed screw loosening and nonunion. Revision surgery was performed in both patients. The patient with bone nonunion was treated using bone grafts. No postoperative infections or peripheral neuropathies were observed. At the final follow-up (average 20 months), we found that the average MEPI functional score of the patients was 91.7 points regardless of the fracture site. Conclusions: Our whole humerus with a single incision was effective for the treatment of segmental comminuted and distal fractures. we believe it is a useful alternative to preexisting methods of fracture fixation.

Strut Support with Tricortical Iliac Allografts in Unstable Proximal Humerus Fractures: Surgical Indication and New Definition of Poor Medial Column Support

  • Lee, Seung-Jin;Hyun, Yoon-Suk;Baek, Seung-Ha
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.1
    • /
    • pp.29-36
    • /
    • 2019
  • Background: The execution of fibular allograft augmentation in unstable proximal humerus fractures (PHFs) was technically demanding. In this study, the authors evaluated the clinical and radiographic outcomes after tricortical iliac allograft (TIA) augmentation in PHFs. Methods: We retrospectively assessed 38 PHF patients treated with locking-plate fixation and TIA augmentation. Insertion of a TIA was indicated when an unstable PHF showed a large cavitary defect and poor medial column support after open reduction, regardless of the presence of medial cortical comminution in preoperative images. Radiographic imaging parameters (humeral head height, HHH; humeral neck-shaft angle, HNSA; head mediolateral offset, HMLO; and status of the union), Constant score, and range of motion were evaluated. Patients were grouped according to whether the medial column support after open reduction was poor or not (groups A and B, respectively); clinical outcomes were compared for all parameters. Results: All fractures healed radiologically (average duration to complete union, 5.8 months). At final evaluation, the average Constant score was 73 points and the mean active forward flexion was $148^{\circ}$. Based on the Paavolainen assessment method, 33 patients had good results and 5 patients showed fair results. The mean loss of reduction was 1.32 mm in HHH and 5.02% in HMLO. None of the parameters evaluated showed a statistically significant difference between the two groups (poor and not poor medial column support). Conclusions: In unstable PHFs, TIA augmentation can provide good clinical and radiological results when there are poor medial column support and a large cavitary defect after open reduction.

Operative Treatment of Displaced Proximal Humerus Fractures with the Angular Stable Locking Compression Plate (각안정 잠김 압박 금속판을 이용한 전위된 근위 상완골 골절에 대한 수술적 치료)

  • Kim, Dong-Wook;Kim, Chong-Kwan;Jung, Sung-Won;Kim, Hyeon-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: We examined the clinical and radiological outcomes for displaced proximal humerus fractures that were treated with a PHILOS angular stable plate. Materials and Method: Forty four patients who underwent surgery between March 2007 and February 2010 were included in this study. All the cases were followed up for an average of 12 months. All the patients were examined and interviewed using the Visual Analog Scale (VAS) score, the Constant score and standardized X-rays to check the neck-shaft angle (NSA) and the presence of medial support. Results: The average Visual Analog Scale score was 2.8 points and the average Constant score was 70.5 points. The average neck shaft angle was $122.5^{\circ}$ and this was statistically significant between the good result group and the poor result group. There were 36 cases of the presence of medial support and 8 cases of the absence of medial support and the difference was statistically significant. Complications such as fixation failure happened in 12 cases. Conclusion: PHILOS angular stable plate fixation as an operative treatment for displaced proximal humerus fractures is a good and reliable treatment option.

The Analysis of the Treatment Outcomes of Proximal Humeral Fractures with Locking Plates

  • Lee, Kwang-Won;Hwang, Yoon-Sub;Kim, Choon-Myeon;Yang, Dae-Suk;Park, Tae-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.10-17
    • /
    • 2014
  • Background: The aim of this study was to assess the clinical outcomes after treatment of proximal humeral fractures with locking plates, and to determine which factors influence the clinical and radiological outcomes. Methods: Fifty six patients who were treated with locking plates for proximal humeral fractures and had been followed for more than 1 year were enrolled in this study. We performed functional evaluation using the Constant score and analyzed radiographic results. The following factors that may potentially influence the clinical outcomes were assessed: age, gender, type of fracture, presence of medial metaphyseal comminution, bone mineral density, anatomical reduction, restoration of medial mechanical support, and postoperative complications. Results: The mean Constant score was 70.1 points at the final follow-up. Female gender, 4-part fractures, AO type-C fractures, and fractures with medial metaphyseal comminution were associated with a poor clinical outcome. On the other hand, restoration of medial mechanical support and accurate anatomical reduction had a positive influence on clinical outcomes. Postoperative complications resulted in 3 patients (intra-articular screw perforation: 1 patient, varus deformity with screw loosening: 1 patient, nonunion: 1 patient). Conclusions: When treating proximal humeral fractures with locking plate fixation, following factors: a female gender, Neer type 4-part fracture, AO type C fracture, and medial metaphyseal comminution are important risk factors that surgeons should take into consideration. Factors that contribute to better clinical outcomes of operative treatment for humeral fractures are accurate anatomical reduction and restoration of medial mechanical support.

Hemiarthroplasty in Comminuted Fracture and Dislocation of the Proximal Humerus (상완골 근위부 분쇄성 골절 및 탈구에서 시행한 견관절 반치환술)

  • Hwang Sung-Kwan;Kim Yong-Seok
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.205-211
    • /
    • 1998
  • The comminuted fracture and dislocation of the proximal humerus occur more frequently in older patient group and operative treatment is difficult due to poor bone quality. Based on Neer's work, hemiarthroplasty has now become widly accepted for the management of the three-part fracture and four-part fracture-dislocation of the proximal humerus in old age group. The purpose of this study is to evaluate function, pain relief, and patient satisfaction after hemiarthroplasty for proximal humerus fractures and dislocations. Authors reviewed and analyzed 14 prosthetic replacement in comminuted proximal humeral fracture and dislocation at the Department of Orthopaedic Surgery, Yonsei University Wonju College of Medicine from March, 1988 to May, 1997. The results were as follows the average age was 58.9years and the ratio of males and females was 5:9. The most common cause of injury was traffic accident(43%). According to the classification of Neer, three part fracture were three(21%), four-part fracture and four-part fracture-dislocation were eleven(79%). The prosthetic replacement was performed within two weeks in eight patient and six were performed after two weeks. The results were analysed according to Neer's criteria and five cases showed satisfactory results. We concluded that hemiarthroplasty for fracture and dislocation of the proximal humerus facilitated the restoration of humerus length and pain relief, thereby allowing earlier motion to prevent the development of painful shoulder: stiffness.

  • PDF

Comparison of Radiologic and Clinical Results between Locking Compression Plate and Unlocked Plate in Proximal Humerus Fractures (근위 상완골 골절에서 잠김 압박 금속판과 비잠김 금속판 고정의 방사선학적 임상적 추시 결과 비교)

  • Kim, Jae-Hwa;Lee, Yun-Seok;Ahn, Tae-Keun;Choi, Jung-Pil
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.143-149
    • /
    • 2008
  • Purpose: The purpose of this study is to compare the results of using a locking compression plate and an unlocked plate for treating proximal humeral fractures. Materials and Methods: This study was based on 20 patients who underwent plate fixation for proximal humeral fractures out of the 87 patients with proximal humeral fractures and who were admitted from 2003 to 2007 in our hospital. Of the 20 patients, 10 were treated with a locking compression plate and the other 10 were treated with an unlocked plate. Each group was evaluated according to the humeral neck shaft angle, the period until bony union, the complications and the Constant score. The humeral neck shaft angle was based on plain x-rays taken immediately after the operation and at 6 months postoperatively. The Constant score was evaluated on the last visit to our clinic. Results: There was no significant statistical difference between the two groups in terms of the neck shaft angle, the period until bony union and the Constant score. Yet, there were three cases of screw migration in the unlocked plate group. Conclusion: There was no significant difference between the two groups in terms of the neck shaft angle, the period until bony union and the Constant score. The locking compression plate is considered to achieve more effective fixation for proximal humerus fractures because there were less complications such as screw migration.

An Anterosuperior Deltoid Splitting Approach for Plate Fixation of Proximal Humeral Fractures

  • Shin, Dong-Ju;Byun, Young-Soo;Cho, Young-Ho;Park, Ki-Hong;Yoo, Hyun-Seong
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.1
    • /
    • pp.2-7
    • /
    • 2015
  • Background: The purpose of this study was to evaluate the usefulness and safety of the anterosuperior deltoid splitting approach for fixation of displaced proximal humeral fractures by analyzing the surgical outcomes. Methods: Twenty-three patients who could be followed-up for at least 8 months after the treatment of displaced proximal humeral fractures through the anterosuperior deltoid splitting approach were enrolled. We evaluated the reduction of the fractures and surgery-related complications at the last follow-up using X-ray results and clinical outcomes comprising the University of California at Los Angeles (UCLA) scoring system and the Korean Shoulder Society (KSS) score. Results: At the last follow-up of patients treated using the anterosuperior deltoid splitting approach for internal fixation of proximal humeral fractures, we found 22 cases (95.6%) of bone union, a mean UCLA score of 28.3 (range, 15 to 34) and a mean KSS score of 82.1 (range, 67 to 95). Various surgery-related complications were noted; a case of varus malunion after fracture displacement, a case of nonunion, a case of delayed union, two cases of impingement, and a case of partial axillary nerve injury, which recovered completely through the follow-up. Conclusions: Plate fixation using the anterosuperior deltoid splitting approach could be another reliable option for treating displaced proximal humeral fractures.

Treatment of Two- and Three-Part Fracture of Proximal Humerus using LCP (잠김 압박 금속판(LCP)을 이용한 상완골 근위부 이분 및 삼분 골절의 치료)

  • Shin, Sung-Il;Song, Kyung-Won;Lee, Jin-Young;Lee, Seung-Yong;Kim, Gab-Rae;Hyun, Yoon-Suk;Park, Deok-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.204-211
    • /
    • 2007
  • Purpose: To evaluate the result and complication of treatment using Locking Compression Plate (LCP) for fracture of proximal humerus. Materials and Methods: Between 2004 and 2006, 21 patients with two-part and three-part fractures of the proximal humerus were treated by LCP fixation. Their average age was 54.9 years. Postoperative mean follow-up period was 22.9 months. The reduction was qualified and complication were assessed with final radiographs. The functional outcome was evaluated by Neer's rating system. Results: By Neer's functional evaluation, mean score of shoulder function was 86.3 and 18 case (86%) had excellent or satisfactory results. There was one case of nonunion but no infection or avascular necrosis of the humeral head. No correlation was found between the final result and the type of fracture, age, gender or quality of reduction. Conclusion: We obtained satisfactory result of LCP fixation for fracture of proximal humerus in this study. LCP fixation for proximal humerus fracture is a reliable method to obtain satisfactory reduction, rigid fixation and early exercise.