• Title/Summary/Keyword: Proximal humerus fractures

Search Result 53, Processing Time 0.039 seconds

PHILOS plate fixation with polymethyl methacrylate cement augmentation of an osteoporotic proximal humerus fracture

  • Kim, Do-Young;Kim, Tae-Yeong;Hwang, Jung-Taek
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.3
    • /
    • pp.156-158
    • /
    • 2020
  • PHILOS plate fixation in osteoporotic proximal humerus fracture of old age is well-known for high complication rate, especially metal failure, providing various augmentation techniques, such as calcium phosphate cement, allogenous or autologous bone graft. We report a case of polymethyl methacrylate augmentation to provide appropriate reduction with a significant mechanical support. This can be a treatment option for displaced unstable osteoporotic proximal humerus fracture with marked bony defect.

Treatment of Proximal Humerus Fracture by Polarus Nailing (폴라루스 골수정을 이용한 상완골 근위부 골절의 치료)

  • Choi, Chang-Hyuk;Kwun, Kong-Woo;Jeung, Dae-Ui;Chang, Ho-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.2
    • /
    • pp.169-175
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the usefullness of polarus nailing in the treatment of proximal humerus fractures including 2 part, 3 part and proximal comminuted fractures. Materials and methods: Fifteen cases of proximal humerus fracture treated with Polarus nailing from March, 2002 to March, 2004 were selected. Man was 3 cases, and woman was 11 cases. There were one case of follow up loss due to decease. Average age was 60 years old (range, 23 to 84), and there were 6 cases of 2 part fracture, 3 cases of proximal segmental fracture, 5 cases of 3 part fracture. We analyzed the outcom results between 2 part fracture and 3 part fracture. The average follow up period after the operation was 1.5(range, 1 to 2) years. Range of motion (ROM), pain and functional outcome were evaluated by visual analogue scale(VAS) and american shoulder and elbow surgery (ASES) activity of daily living (ADL) functional scoring system. Results: All cases showed union on radiologic evaluation, with 2.3 months follow up. In 5 cases of 3 part fracture, average union time was 1.9 months regardless of proximal screw loosening in 4 cases. In 2 part fracture union time was 2.2 months (P>0.05). VAS pain score was 1.3, ROM was $160^{\circ}$ in forward flexion, $40^{\circ}$ in external rotation, L3 level in internal rotation, and ASES, ADL functional score was 21 in 2 part fracture. VAS pain score was 1.25, ROM was $160^{\circ}$, $43^{\circ}$ and L1 level, and ASES, ADL functional score was 21 in 3 part fracture. There were no statistically significant difference between two groups (P>0.05) VAS pain score was 1.6, ROM was $170^{\circ}$, $47^{\circ}$ and L3 level, and ASES, ADL functional score was 23 in proximal comminuted fracture. Conclusion: Polarus nailing could be used as an effective modality in certain cases of proximal humeral fracture including 2 part, proximal segmental and in cases of 3 part fractures with large greater tuberosity fragment.

Indirect Reduction Technique in Proximal Humeral Fractures Stabilized by Locking Plates

  • Rhee, Yong Girl;Cho, Nam Su;Cha, Sang Won;Moon, Seong Cheol;Hwang, Sang Phil
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.2-9
    • /
    • 2014
  • Background: Indirect reduction technique offers a valid option in the treatment of proximal humerus fracture. The purpose of this study is to evaluate the functional outcome and the complication rate after indirect reduction and internal fixation of unstable proximal humeral fractures with use of a locking plate. Methods: Twenty four patients with acute proximal humerus fracture were managed with indirect reduction and internal fixation with a locking plate. The mean follow-up period was 15.5 months. Results: The anatomical reduction of the medial cortex buttress was seen in 16 patients (66%) of the Group A and the non-anatomical reduction was seen in 8 patients (33%) of the Group B. Mean union time was $3.2{\pm}1.9$ months; it was $2.2{\pm}0.6$ months in the Group A and $5.3{\pm}2.2$ months in the Group B (p < 0.05). In our series, there were 6 cases of complications and these include 2 cases of varus malunion, 2 cases of shoulder stiffness, 1 case of heterotrophic ossification, 2 cases of screw perforation and 1 case of impingement. Conclusions: We conclude from our studies that indirect reduction and internal fixation using locking plate for acute proximal humerus fracture can give good results with bony union and predictable good overall functional outcome. If the medial cortex buttress is well maintained, a better anatomical reduction would be achieved, the union would be prompted, the pain would be further reduced and the range of the motion would be recovered more promptly.

Internal Fixation of Proximal Humerus Fracture with Locking Compression Plate (잠김 압박 금속판을 이용한 근위 상완골 골절의 내고정술)

  • Park, Chul-Hyun;Park, Sung-Hyuk;Seo, Jae-Sung
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.44-52
    • /
    • 2009
  • Purpose: We assessed the radiographic and clinical results of one surgeon's experience treating proximal humerus fractures with a locked proximal humeral plate. Materials and Methods: Twenty patients with unstable proximal humerus fractures were treated with a locking compression plate between February 2005 and September 2007. The average age of the patients was 60.6 years, and the average postoperative follow-up period was 22.3 months. The clinical results were evaluated using the Constant and DASH scores. The radiologic results were evaluated by the Paavolainen method, which measures the neck shaft angle and humeral head height. Results: At the last follow-up examination, the mean Constant score was 75.3 and 15 cases (75%) had excellent or good results; the mean DASH score was 16.4. The mean neck shaft angle was $137.1^{\circ}$, and 19 cases (95%) had good results by the Paavolainen method. There was one delayed union, malunion, and screw loosening. Conclusion: The patients treated with a locking compression plate had relatively good clinical and radiologic results, and a low complication rate. Moreover, the patients could exercise earlier due to good reduction and initial stability. Treatment of unstable proximal humerus fractures with a locking compression plate is a reliable method.

Operative Treatment with Intramedullary Fibular Strut Allograft for Osteoporotic Proximal Humerus Fracture

  • Chun, Yong-Min;Lee, Wonyong
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.2
    • /
    • pp.95-99
    • /
    • 2017
  • Background: The purpose of this study was to investigate the clinical and radiological outcomes of locking plate fixation with fibular strut allograft to manage unstable osteoporotic proximal humerus fractures. Methods: We retrospectively reviewed 15 patients who underwent open reduction and locking plate fixation with fibular strut allograft for osteoporotic proximal humerus fracture between July 2011 and June 2015. For functional evaluation, we evaluated visual analogue scale (VAS) pain score, American Shoulder and Elbow Surgeons (ASES) score, University of California Los Angeles (UCLA) shoulder score, and active range of motion. For radiological evaluation, shoulder true anteroposterior (AP) and AP in $20^{\circ}$ external rotation, as well as the axillary view were taken at two weeks, six weeks, three months, six months, and one year. And the neck-shaft angle was measured on the AP view in $20^{\circ}$ external rotation view. Results: At the one-year follow-up, mean VAS pain score and all shoulder scores, including ASES score and UCLA shoulder score, exhibited satisfactory clinical outcomes. All patients obtained bone union between three and six months post-procedure. Moreover, the mean immediate postoperative neck-shaft angle was $138^{\circ}{\pm}4^{\circ}$, and at one-year follow-up, the neck shaft angle was $137^{\circ}{\pm}5^{\circ}$. There was no significant difference between the preoperative and postoperative values (p=0.105). Conclusions: For the unstable two-part and three-part osteoporotic proximal humerus fractures with medial calcar comminution, the use of fibular strut allograft with locking plate fixation was effective in maintaining the initial status of reduction and exhibiting the satisfactory functional and radiological outcomes.

Hook Plate Fixation for Isolated Greater Tuberosity Fractures of the Humerus

  • Lee, Kyoung-Rak;Bae, Ki-Cheor;Yon, Chang-Jin;Cho, Chul-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.222-229
    • /
    • 2017
  • Background: The purpose of this study was to investigate the outcomes after fixation using a 3.5-mm locking compression plate (LCP) hook plate for isolated greater tuberosity (GT) fractures of the proximal humerus. Methods: We evaluated the postoperative radiological and clinical outcomes in nine patients who were followed up at least 1 year with isolated GT fractures. Using the deltopectoral approach, we fixed the displaced GT fragments with a 3.5-mm LCP hook plate (Synthes, West Chester, PA, USA). Depending on the fracture patterns, the hook plate was fixed with or without augmentation using either tension suture or suture anchor fixation. Results: All the patient showed successful bone union. The mean time-to-union was 11 weeks. The radiological and clinical outcomes at the final follow-up were generally satisfactory. The mean visual analogue scale for pain, the University of California at Los Angeles score, the American Shoulder and Elbow Surgeons score, and the subjective shoulder value were 1.4, 30.3, 84.3, and 82.2%, respectively. The mean active forward flexion, abduction, external rotation, and internal rotation of the shoulder were $156.7^{\circ}$, $152.2^{\circ}$, $61.1^{\circ}$, and the 10th thoracic vertebral level, respectively. Only one patient presented with a postoperative complication of shoulder stiffness. The patient was treated through arthroscopic capsular release on the 5th postoperative month. Conclusions: We conclude that fixation using 3.5-mm LCP hook plates for isolated GT fractures of the proximal humerus is a useful treatment method that provides satisfactory clinical and radiological outcomes.