• Title/Summary/Keyword: Proximal fracture

Search Result 249, Processing Time 0.025 seconds

Fracture of Proximal Humerus in the Lateral Anchor Site after Suture Bridge Repair - A Case Report

  • Park, Kyoung-Jin;Kim, Yong-Min;Kim, Dong-Soo;Choi, Eui-Sung;Keum, Sang-Wook;Kil, Kyoung-Min;Lim, Chae-Wook;Park, Sang-Jun
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.3
    • /
    • pp.134-137
    • /
    • 2014
  • To report the fracture of proximal humerus in the lateral anchor site after suture bridge repair. A 57-year-old female patient with shoulder pain on the right-side was admitted through the emergency room following a car accident. Seven weeks before the accident, the patient had undergone surgery at a different hospital for the repair of supraspinatus tendon rupture on the right-side via suture bridge technique. Humerus surgical neck fracture was confirmed by X-ray, and proximal humerus fracture at the anchor site was confirmed by magnetic resonance imaging. Following 7 months of conservative treatment resulted in satisfactory bone union and motion of the shoulder joint. We report the need of close observation during and after the arthroscopic repair of the rotator cuff in patients with osteoporosis.

Spontaneous Femoral Capital Physeal Fracture with Proximal Tibial Epiphyseal Dysplasia in a Cat

  • Yoo, Saejong;Kim, Dae-Hyun;Lee, Yunsub;Yeo, Seungyeob;Kim, Hwi-Yool
    • Journal of Veterinary Clinics
    • /
    • v.36 no.2
    • /
    • pp.112-115
    • /
    • 2019
  • An 11-month-old, 5.6 kg, grade 4 on a 5-point scale body condition score, castrated male Korean short hair cat was presented with right hindlimb lameness for 3 days without trauma. On physical examination, severe pain with crepitation was elicited at the hip region but not at the stifle. Radiographic examination and computed tomography revealed a Salter-Harris type 1 fracture of the femoral capital physis and dysplasia of the proximal tibial epiphysis. Spontaneous femoral capital physeal fracture was suspected and femoral head and neck osteotomy was performed. Treatment for proximal tibial dysplasia was not performed. On histopathologic examination of femoral head, a cluster of chondrocytes in a proliferative zone at the epiphyseal plate was observed. Therefore, spontaneous femoral capital physeal fracture was diagnosed. The patient recovered his gait, and no related clinical signs were observed during 6 months of follow-up.

Surgical Treatment of Ipsilateral Multi-Level Femoral Fracture Treated Using Antegrade Intramedullary Nail

  • Kim, Beom-Soo;Cho, Jae-Woo;Yeo, Do-Hyun;Oh, Jong-Keon
    • Journal of Trauma and Injury
    • /
    • v.31 no.2
    • /
    • pp.96-102
    • /
    • 2018
  • Ipsilateral fractures of proximal femur with shaft and condylar region are very rare. Current concept of management is based on fixation of each fracture as independent entity using separate fixation modalities for proximal and distal parts of femur. However, we considered that antegrade femoral nailing with cephalomedullary screw fixation is a good option for ipsilateral multi-level femoral fractures. Here, we present an experience of satisfactory treatment for ipsilateral femoral neck fracture, subtrochanteric fracture, comminuted shaft fracture with supracondylar fracture following road traffic accident.

Corticosteroids and Proximal Femur Fracture in Elderly Women : the KEPEC Study

  • Lee, Seung-Mi;Kim, Yoo-Ni;Youn, Kyung-Eun;Jung, Kui-Oak;Koo, Hye-Won;Bae, Jong-Myon;Park, Byung-Joo
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.236.2-237
    • /
    • 2002
  • Proximal femur fracture is known as one of the major medical problems in terms of mortality. disability and economic costs. To assess the association between the use of corticosteroids and proximal femur fracture. a cohort study was conducted upon Korean elderly women. (omitted)

  • PDF

Ultrasonographic Finding of Trochanteric Pain after Proximal Femoral Nailing in Patients with Intertrochanteric Fracture - 2 Cases Report - (대퇴 전자간 골절의 근위 대퇴 골수정 삽입술 후 발생한 전자부 통증의 초음파 소견 - 2예 보고 -)

  • Nam, Woo Dong;Han, Kye Young;Cha, Seong Moo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.1
    • /
    • pp.38-41
    • /
    • 2011
  • After closed reduction and internal fixation with proximal femoral nail for intertrochanteric fracture, some patients complained lateral hip pain. We report two cases of lateral hip pain due to tendinopathy confirmed by ultrasonography.

  • PDF

Treatment for the Stress Fracture of the Proximal Phalanx of the Great Toe in a Basketball Player with Hallux Valgus (A Case Report) (무지외반증이 있는 농구 선수에서 발생한 족무지 근위 지골의 피로 골절에 대한 치료(1예 보고))

  • Park, Chul-Hyun;Lee, Woo-Chun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.1
    • /
    • pp.70-72
    • /
    • 2012
  • Stress fractures of the proximal phalanx of the great toe are rare. This fractures have been associated with halux valgus deformity in most reports. We performed open reduction and internal fixation with distal chevron osteotomy for the stress fracture of the proximal phalanx of the great toe in a basketball player with hallux valgus, and obtained successful bony union and rapid return to sports.

Inter-rater agreement among shoulder surgeons on treatment options for proximal humeral fractures among shoulder surgeons

  • Kim, Hyojune;Song, Si-Jung;Jeon, In-Ho;Koh, Kyoung Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.1
    • /
    • pp.49-56
    • /
    • 2022
  • Background: The treatment approach for proximal humeral fractures is determined by various factors, including patient age, sex, dominant arm, fracture pattern, presence of osteoporosis, preexisting arthritis, rotator cuff status, and medical comorbidities. However, there is a lack of consensus in the literature regarding the optimal treatment for displaced proximal humeral fractures. This study aimed to assess and quantify the decision-making process for either conservative or surgical treatment and the choice of surgical method among shoulder surgeons when treating proximal humeral fractures. Methods: Forty sets of true anteroposterior view, scapular Y projection view, and three-dimensional computed tomography of proximal humeral fractures were provided to 12 shoulder surgeons along with clinical information. Surveys regarding Neer classification, decisions between conservative and surgical treatments, and chosen methods were conducted twice with an interval of 2 months. The factors affecting the treatment plans were also assessed. Results: The inter-rater agreement was fair for Neer classification (kappa=0.395), moderate for the decision between conservative and surgical treatments (kappa=0.528), and substantial for the chosen method of surgical treatment (kappa=0.740). The percentage of agreement was 71.1% for Neer classification, 84.6% for the decision between conservative and surgical treatment, and 96.4% for the chosen method of surgical treatment. The fracture pattern was the most crucial factor in deciding between conservative and surgical treatments, followed by age and physical activity. Conclusions: The decision between conservative and surgical treatment for proximal humeral fractures showed good agreement, while the chosen method between osteosynthesis and arthroplasty showed substantial agreement among shoulder surgeons.

Fracture load and survival of anatomically representative monolithic lithium disilicate crowns with reduced tooth preparation and ceramic thickness

  • Nawafleh, Noor A;Hatamleh, Muhanad M;Ochsner, Andreas;Mack, Florian
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.416-422
    • /
    • 2017
  • PURPOSE. To investigate the effect of reducing tooth preparation and ceramic thickness on fracture resistance of lithium disilicate crowns. MATERIALS AND METHODS. Specimen preparation included a standard complete crown preparation of a typodont mandibular left first molar with an occlusal reduction of 2 mm, proximal/axial wall reduction of 1.5 mm, and 1.0 mm deep chamfer (Group A). Another typodont mandibular first molar was prepared with less tooth reduction: 1 mm occlusal and proximal/axial wall reduction and 0.8 mm chamfer (Group B). Twenty crowns were milled from each preparation corresponding to control group (n=5) and conditioned group of simultaneous thermal and mechanical loading in aqueous environment (n=15). All crowns were then loaded until fracture to determine the fracture load. RESULTS. The mean (SD) fracture load values (in Newton) for Group A were 2340 (83) and 2149 (649), and for Group B, 1752 (134) and 1054 (249) without and with fatigue, respectively. Reducing tooth preparation thickness significantly decreased fracture load of the crowns at baseline and after fatigue application. After fatigue, the mean fracture load statistically significantly decreased (P<.001) in Group B; however, it was not affected (P>.05) in Group A. CONCLUSION. Reducing the amount of tooth preparation by 0.5 mm on the occlusal and proximal/axial wall with a 0.8 mm chamfer significantly reduced fracture load of the restoration. Tooth reduction required for lithium disilicate crowns is a crucial factor for a long-term successful application of this all-ceramic system.

The Analysis of the Treatment Outcomes of Proximal Humeral Fractures with Locking Plates

  • Lee, Kwang-Won;Hwang, Yoon-Sub;Kim, Choon-Myeon;Yang, Dae-Suk;Park, Tae-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.10-17
    • /
    • 2014
  • Background: The aim of this study was to assess the clinical outcomes after treatment of proximal humeral fractures with locking plates, and to determine which factors influence the clinical and radiological outcomes. Methods: Fifty six patients who were treated with locking plates for proximal humeral fractures and had been followed for more than 1 year were enrolled in this study. We performed functional evaluation using the Constant score and analyzed radiographic results. The following factors that may potentially influence the clinical outcomes were assessed: age, gender, type of fracture, presence of medial metaphyseal comminution, bone mineral density, anatomical reduction, restoration of medial mechanical support, and postoperative complications. Results: The mean Constant score was 70.1 points at the final follow-up. Female gender, 4-part fractures, AO type-C fractures, and fractures with medial metaphyseal comminution were associated with a poor clinical outcome. On the other hand, restoration of medial mechanical support and accurate anatomical reduction had a positive influence on clinical outcomes. Postoperative complications resulted in 3 patients (intra-articular screw perforation: 1 patient, varus deformity with screw loosening: 1 patient, nonunion: 1 patient). Conclusions: When treating proximal humeral fractures with locking plate fixation, following factors: a female gender, Neer type 4-part fracture, AO type C fracture, and medial metaphyseal comminution are important risk factors that surgeons should take into consideration. Factors that contribute to better clinical outcomes of operative treatment for humeral fractures are accurate anatomical reduction and restoration of medial mechanical support.

Atypical Vancouver B1 periprosthetic fracture of the proximal femur in the United Kingdom: a case report challenged by myeloma, osteoporosis, infection, and recurrent implant failures

  • Sayantan Saha;Azeem Ahmed;Rama Mohan
    • Journal of Trauma and Injury
    • /
    • v.37 no.1
    • /
    • pp.89-96
    • /
    • 2024
  • The indications for total hip replacement are increasing and not limited to osteoarthritis. Total hip replacement may also be done for trauma and pathological fractures in patients otherwise physiologically fit and active. This trend has led to an inevitable rise in complications such as periprosthetic femoral fracture. Periprosthetic femoral fracture can be challenging due to poor bone quality, osteoporosis, and stress fractures. We present a case of periprosthetic femoral fracture in a 71-year-old woman with some components of an atypical femoral fracture. The fracture was internally fixed but was subsequently complicated by infection, implant failure needing revision, and later stress fracture. She was on a bisphosphonate after her index total hip replacement surgery for an impending pathological left proximal femur fracture, and this may have caused the later stress fracture. Unfortunately, she then experienced implant breakage (nonunion), which was treated with a biplanar locking plate and bone grafting. The patient finally regained her premorbid mobility 13 months after the last surgery and progressed satisfactorily towards bony union.