• Title/Summary/Keyword: Protrusion

Search Result 652, Processing Time 0.027 seconds

The Effects of Tongue Positions on the Cervical Range of Motion (혀의 자세가 경추의 관절가동범위에 미치는 영향)

  • Han, Dong-Wook;Park, Min-Hee;Jeong, Yeon-Hee
    • Journal of Korean Clinical Health Science
    • /
    • v.1 no.1
    • /
    • pp.29-34
    • /
    • 2013
  • Purpose : This study was to investigate that tongue positions have effect on the cervical range of motion (ROM). Methods : 18 subjects, 20 to 25 years of age, were participated in this study. The tongue positions were neutral position, anterior protrusion, posterior protrusion, superior protrusion, inferior protrusion, left side protrusion and right side protrusion. The neck movements were right side flexion, left side flexion, right rotation and left rotation. The cervical range of motion measured by cervical range of motion instrument (CROM, C9266-49, USA). The changes were analyzed using the paired t-test. SPSSWIN (ver. 20.0) was used for data analysis and the significance level was chosen as ${\alpha}$=0.05. Results : In the lateral flexion, the angle of left lateral flexion increased in anterior protrusion(p<0.05) and right side protrusion(p<0.05) significantly. In the rotation, the angle of right rotation increased in anterior protrusion(p<0.05), posterior protrusion (p<0.05), superior protrusion(p<0.05), inferior protrusion(p<0.05), and left side protrusion (p<0.05) significantly. Conclusions : In conclusion, we found that the tongue positions affected some cervical movements.

  • PDF

Effects of dimple/protrusion array on heat transfer coefficients in rectangular wavy duct (주름진 덕트에서 딤플/돌출 형상이 열전달계수에 미치는 영향)

  • Kwon, Hyun-Goo;Hwang, Sang-Dong;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2352-2356
    • /
    • 2008
  • Heat transfer and performance characteristics have been investigated for a rectangular wavy duct with dimple or protrusion arrays. The test duct was 15mm in height and 105mm wide. The print diameter of the dimple/protrusion wall was 12.99mm and the depth/height of the dimple/protrusion was 3.75mm. Local heat transfer coefficients on the dimple/protrusion wall were measured using a transient TLC technique. The Reynolds number was varied from 3,000 to 10,000. For the wavy duct tested in this study, adverse static pressure characteristics occurred at turning region of the wavy duct due to secondary flows. For the wavy duct with protrusion array, higher heat transfer enhancement level of 7.4 times than smooth straight case in maximum was obtained at low Reynolds number due to the high heat transfer enhancement by vortex flows. Also, the protrusion array increased the performance level of 3.0 at low Reynolds number of 3,000.

  • PDF

Analysis of laminar forced convection for optimal design of parallel plates with protrusions (돌출부를 갖는 평행평판의 최적 설계를 위한 층류강제대류 해석)

  • 이관수;박철균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.129-136
    • /
    • 1998
  • Pressure drop and heat transfer characteristics of a periodically fully developed flow in the flat channel with protrusions are investigated. The effects of shape and location of protrusion on the pressure drop and heat transfer are numerically analyzed in the present study. Taguchi method is used to optimize these parameters. It is found that the ratio of the height of protrusion to channel height shows larger influence on the pressure drop and heat transfer than the ratio of the length of protrusion to module length. As the height of protrusion increases, pressure drop and heat transfer increase, but if the height of protrusion exceeds 2/3 of the channel height, there is a substantial pressure drop. The results also show that the optimal length and height of protrusion are half of the module length and half of the channel height, respectively.

  • PDF

Comparison of panoramic radiography and cone-beam computed tomography for assessing radiographic signs indicating root protrusion into the maxillary sinus

  • Jung, Yun-Hoa;Cho, Bong-Hae;Hwang, Jae Joon
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.309-318
    • /
    • 2020
  • Purpose: This study investigated correlations between findings on panoramic radiographs and cone-beam computed tomography (CBCT) to assess the relationship between the maxillary sinus floor and the roots of maxillary posterior teeth. In addition, radiographic signs indicating actual root protrusion into the maxillary sinus were evaluated on panoramic radiographs. Materials and Methods: Paired panoramic radiographs and CBCT images from 305 subjects were analyzed. This analysis classified 2,440 maxillary premolars and molars according to their relationship with the maxillary sinus floor on panoramic radiographs and CBCT images. In addition, interruption of the sinus floor was examined on panoramic radiographs. Results: Root protrusion into the maxillary sinus occurred most frequently in the mesiobuccal roots of the second molars. The classification according to panoramic radiographs and CBCT images was the same in more than 90% of cases when there was no contact between the root apex and the sinus floor. When the panoramic radiograph showed root protrusion into the sinus, the CBCT images showed the same classification in 67.5% of second molars, 48.8% of first molars, and 53.3% of second premolars. There was a statistically significant relationship between interruption of the sinus floor on panoramic radiographs and root protrusion into the sinus on CBCT images. Conclusion: The presence of root protrusion into the sinus on panoramic radiographs demonstrated a moderate ability to predict root protrusion into the maxillary sinus. Interruption of the maxillary sinus floor could be considered an indicator of actual root protrusion into the maxillary sinus.

Evaluation on Protrusion of the Imaginary Prostate Volume Using Three-Dimensional Volume Rendering (3차원 볼륨 렌더링을 이용한 가상 돌출형 전립선 부피 평가)

  • Seoung, Youl-Hun;Joo, Yong-Hyun;Rhim, Jae-Dong;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.208-215
    • /
    • 2009
  • This study is to compare the accuracy of evaluation regarding the volume of the prostate, which three-dimensional volume rendering was produced the shape of protrusion, by measuring two kinds of craniocaudal length from the top of the protrusion and from the exclusion of the protrusion as the starting points. For the imaginary protrusion prostate models, total of 10 models were roughly made by using devils-tongue jelly and changing each of the 10 ml of capacity from 10 ml to 100 ml. For the protrusion prostate models aimed at estimating the real volume, through 64 cannel computed tomography (CT) and 3.0 tesla magnetic resonance image (MRI) were conducted by planimetry technique from three-dimensional volume rendering. And then we performed to evaluate on significance of these volumes by wilcoxon signed rank test. Also the obtained volumes data by ellipsoid volume formula were measured the volume of protrusion prostate models two times with each method using the two kinds of craniocaudal length from top of the protrusion and from exclusion of the protrusion as the starting points. Finally, the significance of differences using wilcoxon signed rank test was evaluated between the real volume by planimetry technique and the measured volume by ellipsoid volume formula from three-dimensional volume rendering. The average of the protrusion length on the models was $0.90{\pm}0.18\;mm$ in CT and was $0.75{\pm}0.11\;mm$ in MRI. There were not statistically significant difference between MRI and CT from the volume of protrusion prostate models (p=0.414). In MRI (p=0.139) and CT (p=0.057), there were not statistically significant difference between the real volume by planimetry technique and the measured volume by ellipsoid volume from exclusion of the protrusion as the starting points. While, there were statistically significant difference between the real volume by planimetry technique and the measured volume by ellipsoid volume from top of the protrusion as the starting points in MRI (p=0.005) and CT (p=0.005). For the accurate measurement of the protrusion prostate models, the craniocaudal length of the prostate should be measured from the exclusion of the protrusion as the starting points.

  • PDF

A Study on the Breakdown Mechanism of Compressed $SF_6$ by Polarity of a Protrusion on Electrode Surface (전극표면상 미소돌기의 극성에 의한 압축 $SF_6$ 개스의 절연파괴 Mechanism에 관한 연구)

  • 이동인;이광식;김인식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.9
    • /
    • pp.956-963
    • /
    • 1990
  • The general shapes of prebreakdown pulses in a discharge gap were calculated and the current pulses due to avalanche were detected in SF6 by changing the polarity of the protrusion placed on an electrode at pressures up to about 400 Kpa. The mathematical model of prebreakdown pulse development with a negative protrusion shows agreement with the observed pulses. No evidence of intense bursts of field-emitted electrons was observed. Breakdown probably results from a single avalanche developing to a critical size. However the calculated shape of prebreakdown current pulse does not agree with the observed pulses with a positive protrusion. The breakdown is preceded by multiple avalanche development at pressures less than about 200 Kpa. This observation has been interpreted as due to the formation of negative ions following photoionization in the gas which drift into the critical volume near a positive protrusion.

  • PDF

Discrimination of Intervertebral Disk Extrusion from Protrusion with MR Imaging

  • Kim, Jee-Young;Jee, Won-Hee;Ha, Kee-Yong;Park, Chun-Kun;Cho, So-Hee;Byun, Jae-Young
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.138-138
    • /
    • 2002
  • To determine the accuracy of magnetic resonance (MR) imaging for discrimination between intervertebral disk extrusion versus protrusion. MR images of 80 patients who had MR imaging of the spine and confirmed as intervertebral disk extrusion or protrusion were retrospectively reviewed by an experienced musculoskeletal radiologist. A 1.5-T scanner was used. After review of medical records, MR findings of disk extrusion and protrusion were compared using the chi-square test. Intraobserver agreement for differentiation of disk extrusion from protrusion was calculated by using coefficient.

  • PDF

Fast Fringe-field-switching Liquid Crystal Cell with a Protrusion Structure

  • Park, Sung Il;Choi, Sun-Wook;Kim, Ki-Han;Song, Dong Han;Shim, Yu Ri;Lee, Sun Yong;Kang, Sung Gu;Yoon, Jeong Hwan;Kim, Byeong Koo;Yoon, Tae-Hoon
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.200-204
    • /
    • 2013
  • We propose a cell structure for the fast switching of liquid crystals by the fringe field. By forming protrusion between patterned electrodes, we can obtain enhancement of response time. The protrusion reduces the effective cell gap, with which a fast response time can be realized. There is little decrease in the transmittance because the protrusion is located between patterned electrodes. We confirmed that the total response time can be decreased by 33% with little loss of the transmittance by optimizing the shape of the protrusion structure.

Numerical Study on Heat Transfer and Pressure Drop Characteristics in a Horizontal Channel with Dimple and Protrusion Arrays (딤플과 돌출이 설치된 수평채널의 열전달 및 압력강하 특성에 관한 수치해석적 연구)

  • Kim, Ji-Hoon;Heo, Joo-Nyoung;Shin, Jee-Young;Son, Young-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.57-63
    • /
    • 2012
  • In this study, numerical analyses were performed on pressure drop and heat transfer characteristics in a rectangular horizontal channel with dimple and protrusion arrays of different height. The dimples/protrusions were installed at both top and bottom walls of the rectangular channel. The dimple and protrusion depths are 0.125, 0.2, 0.25, 0.3, and 0.375 times diameter. In case of the dimple, the highest Nusselt number occurred at the rear side of the dimple, and the average Nusselt number tended to decrease slightly with increase of depth. In case of protrusion, on the other hand, the highest Nusselt number occurred at the front side of the protrusion, and the average Nusselt number was increased with the increase of height. In both dimple and protrusion, the average Nusselt number and pressure drop were increased with the increase of velocity. Performance factor was decreased with the increase of velocity, and it was found that the best performance factor was obtained in the low velocity region.

Numerical Analysis of Thermo-mechanical Stress and Cu Protrusion of Through-Silicon Via Structure (수치해석에 의한 TSV 구조의 열응력 및 구리 Protrusion 연구)

  • Jung, Hoon Sun;Lee, Mi Kyoung;Choa, Sung-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.20 no.2
    • /
    • pp.65-74
    • /
    • 2013
  • The through-silicon via (TSV) technology is essential for 3-dimensional integrated packaging. TSV technology, however, is still facing several reliability issues including interfacial delamination, crack generation and Cu protrusion. These reliability issues are attributed to themo-mechanical stress mainly caused by a large CTE mismatch between Cu via and surrounding Si. In this study, the thermo-mechanical reliability of copper TSV technology is investigated using numerical analysis. Finite element analysis (FEA) was conducted to analyze three dimensional distribution of the thermal stress and strain near the TSV and the silicon wafer. Several parametric studies were conducted, including the effect of via diameter, via-to-via spacing, and via density on TSV stress. In addition, effects of annealing temperature and via size on Cu protrusion were analyzed. To improve the reliability of the Cu TSV, small diameter via and less via density with proper via-to-via spacing were desirable. To reduce Cu protrusion, smaller via and lower fabrication temperature were recommended. These simulation results will help to understand the thermo-mechanical reliability issues, and provide the design guideline of TSV structure.