• 제목/요약/키워드: Proton Beam Current

검색결과 35건 처리시간 0.017초

The optimization study of core power control based on meta-heuristic algorithm for China initiative accelerator driven subcritical system

  • Jin-Yang Li;Jun-Liang Du;Long Gu;You-Peng Zhang;Cong Lin;Yong-Quan Wang;Xing-Chen Zhou;Huan Lin
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.452-459
    • /
    • 2023
  • The core power control is an important issue for the study of dynamic characteristics in China initiative accelerator driven subcritical system (CiADS), which has direct impact on the control strategy and safety analysis process. The CiADS is an experimental facility that is only controlled by the proton beam intensity without considering the control rods in the current engineering design stage. In order to get the optimized operation scheme with the stable and reliable features, the variation of beam intensity using the continuous and periodic control approaches has been adopted, and the change of collimator and the adjusting of duty ratio have been proposed in the power control process. Considering the neutronics and the thermal-hydraulics characteristics in CiADS, the physical model for the core power control has been established by means of the point reactor kinetics method and the lumped parameter method. Moreover, the multi-inputs single-output (MISO) logical structure for the power control process has been constructed using proportional integral derivative (PID) controller, and the meta-heuristic algorithm has been employed to obtain the global optimized parameters for the stable running mode without producing large perturbations. Finally, the verification and validation of the control method have been tested based on the reference scenarios in considering the disturbances of spallation neutron source and inlet temperature respectively, where all the numerical results reveal that the optimization method has satisfactory performance in the CiADS core power control scenarios.

MC50 싸이클로트론에서 생성되는 중성자선의 생물학적 특성의 평가 (Evaluation of Biological Characteristics of Neutron Beam Generated from MC50 Cyclotron)

  • 엄근용;박혜진;허순녕;예성준;이동한;박석원;우홍균
    • Radiation Oncology Journal
    • /
    • 제24권4호
    • /
    • pp.280-284
    • /
    • 2006
  • 목 적: 원자력의학원에 설치되어 있는 MC50 사이클로트론에서 생성되는 중성자선의 의학적 이용을 위하여 생물학적 특성을 평가하고자 하였다. 대상 및 방법: 35 MeV 양성자를 15 mm 베릴륨 표적에 부딪혀서 생성된 중성자선에 대하여 물리적 방사선선량을 측정한 후 체외실험(in-vitro)을 하였다. EMT-6 세포주(cell line)를 이용하여 $0{\sim}5\;Gy$의 중성자선을 조사 후 생존분획(surviving fraction)을 구하였다. 또한 감마선의 효과를 피하기 위하여 납차폐를 한 후에 동일 조건에서 생존분획을 구하였다. 엑스선 실험에서는 0, 2, 5, 10, 15 Gy를 조사 후 생존분획을 측정하였다. 결 과: MC50의 중성자선은 조사야 $26{\times}26\;cm^2$, 전류 $10{\mu}A$, 깊이 2 cm에서 84%의 중성자와 16%의 감마선으로 구성되어 있었고, 총선량률은 9.25 cGy/min이었다. 엑스선을 이용하여 측정한 생존분획곡선은 선형이차함수모델 (linear quadratic model)을 적용하였을 때 ${\alpha}/{\beta}$비는 0.611 (${\alpha}=0.0204,\;{\beta}=0.0334,\;R^2=0.999$)이었다. 중성자선에 있어서 생존분획곡선은 저선량 영역에서 어깨영역(shoulder area)을 가지고 있었고, 모든 실험에서 선형이차함수모델에 잘 맞았다. ${\alpha}$의 평균값은 -0.315 (범위, $-0.254{\sim}-0.360$)였고, ${\beta}$값은 0.247 (범위, $0.220{\sim}0.262$)이었다. 납차폐를 하였을 때에도 생존분획곡선에서 어깨영역은 없어지지 않았다. 중성자선의 RBE (relative biological effectiveness) 값은 생존분획이 0.1일 때 $2.07{\sim}2.19$ 범위였고, 0.01일 때 $2.21{\sim}2.35$였다. 결 론: MC50에서 생성된 중성자선은 상당량의 감마선을 내포하고 있으며 이것이 생존분획곡선에서 어깨영역이 나타나는 데에 기여하였을 것이다. MC50의 중성자선의 RBE 값은 약 2.2였다.

MC-50 싸이클로트론을 이용한 $^{123}I$ 제법 연구 (The Development of Iodine-123 with MC-50 Cyclotron)

  • 서용섭;양승대;전권수;이종두;한현수
    • 대한핵의학회지
    • /
    • 제25권2호
    • /
    • pp.286-293
    • /
    • 1991
  • $^{123}I$, which is applied for the thyroid and other in vivo kinetic study, has a special role in life sciences. The 159 KeV $\gamma-ray$ from $^{123}I$ is almost ideally appropriate for the current imaging instrumentation. Its decay mode (electron capture) and short half-life (13.3 hr) reduced the burden of radiation dose to the patients, and its chemical property makes it easy to synthesize the labelling compounds. In this experiment, the production of $^{123}I$ via the nuclear reaction $^{124}Te(p,2n)^{123}I$ with 28 MeV protons was sutdied. $TeO_2$ is used as a target material, because it has good physical properties. The target was prepared with $TeO_2$ powder and was molten into a ellipsoidal cavity (a=14 mm, b=10 mm, $270.8mg/cm^2$ thick) of pure platinum. The irradiation was carried out in the external proton beam with incident energies range from 28 MeV to 22 MeV, and current was $30{\mu}A$. The loss of $TeO_2$ target was significantly reduced by using $4\pi-cooling$ system in irradiation. The dry distillation method was adopted for the separation of $^{123}I$ from irradiated target, and when it was kept 5 minutes at $780^{\circ}C$, its result was quantitative. The loss of the target material $(TeO_2)$ was below 0.2% for each production run and $^{123}I$ from the dry distillation apparatus was captured with 0.01 N NaOH in $Na^{123}I$ form, then the pH of the solution was adjusted to $7.5\sim9.0$ with HC1/NaOH. The $Na^{123}I$ solution was passed through $0.2{\mu}m$ membrane filter, and sterilized under high pressure and temperature for 30 minutes. The production of $^{123}I$ is acceptable for clinical application based on the quality of USP XXI.

  • PDF

방사선치료분야에서 의학물리사의 적정인력 분석 (Study on Staffing of Medical Physicist in the Field of Radiation Therapy)

  • 황의중;임영경;김동욱;신동오;김성규;정해조;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.209-218
    • /
    • 2012
  • 최근 방사선치료기기 및 방사선치료기술이 빠르게 발전하고 복잡해짐에 따라 방사선치료의 신뢰성을 높이고 정확한 환자 치료와 환자 및 치료관련 종사자의 방사선안전을 확보하기 위하여 자격있는 의학물리사 적정 인원에 대한 재평가가 이루어지고 있다. 방사선치료분야에서 의학물리사의 적정한 인원수준에 대하여 외국의 연구사례 및 결과에 대해 미국과 유럽을 중심으로 분석하였다. 또한 외국연구결과를 토대로 국내에 필요한 의학물리사의 적정 인원을 간접적으로 계산해 보았다. 국내 중대형 6개 병원의 현재 의학물리사 적정 인원은 국제적 적정 권고 인원의 50% 이하였다. 더욱 더 객관적인 의학물리사의 필요 인원수를 예측하기 위하여는 국내 여건에 적합한 추가적인 연구가 요구되며, 특히 지속적으로 증가되고 있는 입자방사선치료를 고려한 인원수 예측이 필요하다.

친전자성 치환반응을 위한 $[^{18}F]F_2$ Gas의 생산 연구 (Production of $[^{18}F]F_2$ Gas for Electrophilic Substitution Reaction)

  • 문병석;김재홍;이교철;안광일;천기정;전권수
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권4호
    • /
    • pp.228-232
    • /
    • 2006
  • 목적 : $[^{18}F]F_2\;(T_{1/2}=110\;min)$ 기체를 이용하여 친전자성 치환반응으로 방사성동위원소 $^{18}F$을 표지하는 방법은 새로운 앙전자방출단층촬영용 방사성의약품 개발 분야에서 유용하게 이용되고 있다. 그림에도 불구하고 $[^{18}F]F_2$를 높은 생산수율과 비방사능으로 생산하기 위한 표적 개발 연구는 아직도 진행 중에 있다. 본 연구에서는 친핵성 치환반응으로 $^{18}F$을 도입하기 어려운 방사성의약품에 친전자성 치환반응으로 방사성동위원소를 도입할 수 있는 $[^{18}F]F_2$ 가스의 효율적인 생산에 관해 연구하였다. 대상 및 방법: 표적은 원추형 모양의 알루미늄 재질로 제작하였다. $[^{18}F]F_2$ 생산을 위한 핵반응으로 $^{18}O(p,n)^{18}F$를 사용하였으며, two-step 빔 조사방법을 이용하였다. 첫 번째 조사는 농축 $[^{18}O]O_2$가스를 표적에 충진한 후 빔 조사하여 $^{18}O(p,n)^{18}F$ 핵반응을 일으킴으로써 $^{18}F$를 생산한다. 생산된 $^{18}F$은 표적 챔버 기벽에 흡착된다. $[^{18}O]O_2$은 재사용을 위하여 냉각포획법으로 회수하였으며, $^{18}F$를 회수하기 위해 $[^{19}F]F_2/Ar$ 가스를 충진한 후, 두 번째 빔을 조사하여 방사성불소를 회수하는 방법으로 구성된다. 본 연구에서는 최적의 방사성불소 생산 조건을 찾기 위해 빔 조사 시간, 빔 전류 세기 농축 $[^{18}O]O_2$ 충진 압력 등의 변화에 따라 생산량을 평가하였다. 결과: 빔 조사 시간, 빔 전류, 농축 $[^{18}O]O_2$ 충진 압력 등의 조건을 변화시키면서 생산량을 평가한 결과 최적의 빔 조사 조건은 다음과 같다. 첫 번째 조사: 농축 $[^{18}O]O_2$을 약 15.0 bar충진, 13.2 MeV, 30 ${\mu}A$로 60-90분 조사; 두 번째 조사: 1% $[^{19}F]F_2/Ar$혼합가스 12.0 bar 충진, 13.2 MeV, 30 ${\mu}A$로 20-30분 조사 후 아르곤 가스로 회수하였을 때 EOB(end of bombardment) 기준으로 약 $34{\pm}6.0$ GBq(n>10)의 $[^{18}F]F_2$를 얻었다. 결론: $^{18}O(p,n)^{18}F$ 핵반응을 이용하여 친전자성 방사성동위원소 $[^{18}F]F_2$를 생산하였다. 표적 챔버는 알루미늄으로 제작하였으며 본 연구에서 연구된 $[^{18}F]F_2$가스는 친핵성 치환반응으로 방사성동위원소를 도입하기 어려운 다양한 방사성의 약품개발에 유용하게 이용될 수 있을 것이다.