• Title/Summary/Keyword: Protocol analysis

Search Result 2,539, Processing Time 0.034 seconds

A Study on the Variable Factors for Brain Perfusion SPECT(Diamox) Scan (Brain Perfusion SPECT(Diamox) 검사의 수행결과에 영향을 주는 요인)

  • Lee, Jin-Hyeong;Kim, Sang-Eon;Park, Hyeon-Soo;Park, Yeoung-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.99-103
    • /
    • 2011
  • Purpose: Head movement during brain perfusion SPECT (Diamox) scan is a one of important issues which decreases image quality. It also causes repeated scans. This study was designed to evaluate variable factors causing scan failures. Materials and Methods: 676 patients (359 men, 317 women, age average $54.5{\pm}18.4$) for brain perfusion SPECT (Diamox) scan from March, 2010 to Feb. 2011 were used as a subject. Age data and the kind of disease(Moyamoya disease (MMD), None moyamoya disease (NMMD), Cerebral infarction (CI)), test performance outcome (success,failure) were collected. The head movement factors(gender, disease, age, head fixation device) were evaluated by chi-square test and logistic regression analysis Results: The result showed that men had higher scan failure rate than women. Seniors in seventies(men 3.4%, women 1.5%) showed the most highest failure rate. Using head fixation device increased scan success rate up to 94.4~97.7%. The scan success rate is dependent upon gender, head fixation device by chi-square test(${\chi}^2$=3.8 (df=1, p<0.05), ${\chi}^2$=10.4 (df=1, p<0.001)) Gender, disease(CI), head fixation device showed very effective result in logistic regression analysis.(Wald=3.3 (p<0.07), Wald=3.7 (p<0.05), Wald=9.3 (p<0.05) Conclusion: It is demonstrated that gender, disease, using head fixation device is statistically very useful factors. Especially, head fixation device is a main key minimizing repeated scan.

  • PDF

Analysis of the Amount of Telomeric DNA and Telomerase Activity on Preimplantation Mouse Embryoic Cells (마우스 수정란의 초기 배 발생단계별 Telomeric DNA의 양적 분석과 Telomerase 활성도 분석)

  • Kang M. Y.;Han M. S.;Lee S. C.;Kim J. H.;Sohn S. H.
    • Reproductive and Developmental Biology
    • /
    • v.29 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Telomeres consisting of (TTAGGG)n tandem repeat DNA sequences and associated proteins are essential for chromosome stability and related with cell senescence, apoptosis and cancer. The telomerase is a ribonucleoprotein which act as a template for the synthesis of telomeric DNA. This study was carried out to identify the distribution of telomeres on mouse chromosomes and also to analyze the amount of telomeres and telomerase activity of mouse embryos at early embryonic stages. Germ cells and early embryos from 1 cell to blastocyst stage were analyzed. The amount of telomeres was analyzed by quantitative fluorescence in situ hybridization technique(Q-FISH) using a human telomeric DNA probe, and telomerase activity was measured by telomeric repeat amplification protocol assay(TRAP). In results, the telomeres on mouse chromosomes were distributed at the ends of all autosomes and sex chromosomes. Although the quantity of telomeres varied among chromosomes, most of chromosomes had higher amount in q-arm telomeres than in p-arm telomeres. The results of Q-FISH indicated that the relative amount of telomeres of mouse embryos in each embryonic stage was approximately the same except the higher amount in blastocysts. Using TRAP assay on mouse embryos, telomerase activity was detected in all preimplantation stages from mature oocytes to blastocysts. Especially the telomerase activity was significantly increased at the morula and blastocyst stage. In conclusion, there may be a close association between the amount of telomeres and telomerase activity in early embryonic stages, and analysis of telomere quantity and telomerase activity on early development will be helpful for the investigation of embryogenesis and embryonic cell differentiation in mice.

Evaluation of the Measurement Uncertainty from the Standard Operating Procedures(SOP) of the National Environmental Specimen Bank (국가환경시료은행 생태계 대표시료의 채취 및 분석 표준운영절차에 대한 단계별 측정불확도 평가 연구)

  • Lee, Jongchun;Lee, Jangho;Park, Jong-Hyouk;Lee, Eugene;Shim, Kyuyoung;Kim, Taekyu;Han, Areum;Kim, Myungjin
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.6
    • /
    • pp.607-618
    • /
    • 2015
  • Five years have passed since the first set of environmental samples was taken in 2011 to represent various ecosystems which would help future generations lead back to the past environment. Those samples have been preserved cryogenically in the National Environmental Specimen Bank(NESB) at the National Institute of Environmental Research. Even though there is a strict regulation (SOP, standard operating procedure) that rules over the whole sampling procedure to ensure each sample to represent the sampling area, it has not been put to the test for the validation. The question needs to be answered to clear any doubts on the representativeness and the quality of the samples. In order to address the question and ensure the sampling practice set in the SOP, many steps to the measurement of the sample, that is, from sampling in the field and the chemical analysis in the lab are broken down to evaluate the uncertainty at each level. Of the 8 species currently taken for the cryogenic preservation in the NESB, pine tree samples from two different sites were selected for this study. Duplicate samples were taken from each site according to the sampling protocol followed by the duplicate analyses which were carried out for each discrete sample. The uncertainties were evaluated by Robust ANOVA; two levels of uncertainty, one is the uncertainty from the sampling practice, and the other from the analytical process, were then compiled to give the measurement uncertainty on a measured concentration of the measurand. As a result, it was confirmed that it is the sampling practice not the analytical process that accounts for the most of the measurement uncertainty. Based on the top-down approach for the measurement uncertainty, the efficient way to ensure the representativeness of the sample was to increase the quantity of each discrete sample for the making of a composite sample, than to increase the number of the discrete samples across the site. Furthermore, the cost-effective approach to enhance the confidence level on the measurement can be expected from the efforts to lower the sampling uncertainty, not the analytical uncertainty. To test the representativeness of a composite sample of a sampling area, the variance within the site should be less than the difference from duplicate sampling. For that, a criterion, ${i.e.s^2}_{geochem}$(across the site variance) <${s^2}_{samp}$(variance at the sampling location) was proposed. In light of the criterion, the two representative samples for the two study areas passed the requirement. In contrast, whenever the variance of among the sampling locations (i.e. across the site) is larger than the sampling variance, more sampling increments need to be added within the sampling area until the requirement for the representativeness is achieved.

The Application of Dynamic Acquisition with Motion Correction for Static Image (동적 영상 획득 방식을 이용한 정적 영상의 움직임 보정)

  • Yoon, Seok-Hwan;Seung, Jong-Min;Kim, Kye-Hwan;Kim, Jae-Il;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • Purpose: The static image of nuclear medicine study should be acquired without a motion, however, it is difficult to acquire static image without movement for the serious patients, advanced aged patients. These movements cause decreases in reliability for quantitative and qualitative analysis, therefore re-examination was inevitable in the some cases. Consequently, in order to improve the problem of motion artifacts, the authors substituted the dynamic acquisition technique for the static acquisition, using motion correction. Materials and Methods: A capillary tube and IEC body phantom were used. First, the static image was acquired for 60 seconds while the dynamic images were acquired with a protocol, 2 sec/frame${\times}$30 frames, under the same parameter and the frames were summed up into one image afterwards. Also, minimal motion and excessive motion were applied during the another dynamic acquisition and the coordinate correction was applied towards X and Y axis on the frames where the motion artifact occurred. But the severe blurred images were deleted. Finally, the resolution and counts were compared between the static image and the summed dynamic images which before and after applying motion correction, and the signal of frequency was analysed after frequency spatial domain was transformed into 2D FFT. Supplementary examination, the blind test was performed by the nuclear medicine department staff. Results: First, the resolution in the static image and summed dynamic image without motion were 8.32 mm, 8.37 mm on X-axis and 8.30 mm, 8.42 mm on Y-axis, respectively. The counts were 484 kcounts, 485 kcounts each, so there was nearly no difference. Secondly, the resolution in the image with minimal motion applying motion correction was 8.66 mm on X-axis, 8.85 mm on Y-axis and had 469 kcounts while the image without motion correction was 21.81 mm, 24.02 mm and 469 kcounts in order. So, this shows the image with minimal motion applying motion correction has similar resolution with the static image. Lastly, the resolution in the images with excessive motion applying motion correction were 9.09 mm on X-axis, 8.83 mm on Y-axis and had 469 kcounts while the image without motion correction was 47.35 mm, 40.46 mm and 255 kcounts in order. Although there was difference in counts because of deletion of blurred frames, we could get similar resolution. And when the image was transformed into frequency, the high frequency was decreased by the movement. However, the frequency was improved again after motion correction. In the blind test, there was no difference between the image applying motion correction and the static image without motion. Conclusion: There was no significant difference between the static image and the summed dynamic image. This technique can be applied to patients who may have difficulty remaining still during the imaging process, so that the quality of image can be improved as well as the reliance for analysis of quantity. Moreover, the re-examination rate will be considerably decreased. However, there is a limit of motion correction, more time will be required to successfully image the patients applying motion correction. Also, the decrease of total counts due to deletion of the severe blurred images should be calculated and the proper number of frames should be acquired.

  • PDF

A Study on the Psychological State of the Security Subjects of National Guard (공경호원의 경호대상자 심리상태 인지)

  • Kim, Haw-Su;Kang, Min-Wan;Jo, Sung-Gu
    • Korean Security Journal
    • /
    • no.31
    • /
    • pp.73-100
    • /
    • 2012
  • Republic of Korea for the last 2012 nuclear security summit in Seoul in three days from March 26, has held great success. This industry watchers at home and abroad through professional meetings and private organizations to promote global nuclear security was intended to draw, for the preparation of this event the most important one of the things that should be addressed at the meeting was over the top guard. The national guard of heads of state and nationally significant as the important issues should be dealt with. So who is responsible for national security summit national guard for a successful guard against participants should have a higher understanding, these stories ever to be dealt with important security subjects is the psychological state of cognition. This study is currently a source of honor to escort the psychological state of subjects, and whether the search as I looked at cognition. Qualitative research methods to conduct research in-depth interview technique was used for one of the transcribed data analysis program, a non-quantitative data were analyzed using NVivo 8. As a result of this study, analysis of the problem compared with the usual methods 39 (72.2%), fine-grained observation and 15 (27.7%), through the media how cognition 41 (73.2%), marginal help of 15 (26.7%) were. The usual comparison with how honored Issue sources to detect security of those words and actions and facial expressions, etc. Security of subjects over the state of mind cognition that he, detailed observation of the national guard to security subjects the psychological state of cognition which are pre-Thorough Information subjects that can have all the information about security and the state can be obtained by saying that. Media coverage through a cognitive approach national guard of the media coverage to understand the security subjects of the political situation to understand the prerequisite that were marginal for help through the cognitive approach of security subjects surrounding the execution of security workers, Secretary in charge of protocol and security, and be propagated through the selection techniques to be utilized was that.

  • PDF

Development of soil certified reference material for determination of the hazardous elements (유해원소 측정용 토양 인증표준물질 개발)

  • Kim, In-Jung;Min, Hyung-Sik;Suh, Jung-Ki;Han, Myung-Sub;Lim, Myung-Chul;Kim, Young-Hee;Shin, Sun-Kyoung;Cho, Kyung-Haeng
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.485-491
    • /
    • 2010
  • A certified reference material (CRM) of KRISS 109-03-SSD was developed for the analysis of hazardous elements in soil. The target elements were As, Cd, Cr, Cu, Hg, Ni, Pb, Zn being regulated by the Soil Environment Conservation Act. Starting material was collected from tailing dump of an unworked tungsten mine at Sangdong (Gangwon-do, Korea). The starting material under-went through a series of fabricating process steps of screening, drying, grinding, sieving, blending, bottling, sterilization and was certified according to the ISO Guide 35. Isotope dilution-inductively coupled mass spectrometry (ID-ICP/MS) and instrumental neutron activation analysis (INAA) were used for the measurement. Homogeneity was tested according to ISO 13528 annex B. The certified values were determined using the results from two different methods or from two independent measurements using a method. Finally, certified values of seven elements of arsenic, cadmium, chromium, copper, lead, nickel and zinc were determined. Mercury did not satisfied the criteria of homogeneity and the result would be provided for information only, together with iron and tungsten. It was also studied, the extractable fraction of elements by aqua regia according to the ISO 11466 protocol being frequently studied for the purpose of environmental monitoring. It was performed as a inter-laboratory study by 6 laboratories of a public institute and universities. Standard deviation among the laboratories was much bigger than the uncertainty of the certified value. The result of inter-laboratory study on the extractable fraction will be provided for information, only.

A Comparative Analysis of Standard Uptake Value Using the Recovery Coefficient Before and After Correcting Partial Volume Effect (부분 체적 효과에서 회복 계수를 이용한 보정 전과 후 SUV의 비교 분석)

  • Ko, Hyun-Soo;Park, Soon-Ki;Choi, Jae-Min;Kim, Jung-Sun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.10-16
    • /
    • 2011
  • Purpose: The partial volume effect occurs because of limit of the spatial resolution. It makes partial loss of intensity and causes SUV to be lower than it should actually be. So the purpose of this study is to calculate recovery coefficient for correcting PVE from phantom study and to compare before and after SUV correction applying to PET/CT examination. Materials and Methods: The flangeless Esser PET phantom consisting of four hot cylinders was used for this study. All of the hot cylinders were filled with FDG solution of 20.72 MBq per 1000 ml, and the phantom background was filled with FDG solution of different concentrations (33.30, 22.20, 16.65 MBq per 6440 ml) to yield H/B ratios of around 4:1, 6:1 and 8:1. Using the Biograph Truepoint 40(SIEMENS, Germany), we applied recovery coefficient method to 30 patients who were diagnosed with lung cancer after PET/CT exam. And then we analyzed and compared SUV before and after correcting partial volume effect. Results: The smaller the diameter of hot cylinder becomes, the more recovery coefficient decreased. When we applied recovery coefficient to clinical patients and compared SUV before and after correcting PVE, before the correction all lesions gave an average max SUV of 7.83. And after the correction, the average max SUV increases to 10.31. The differences in the max SUV between before and after correction were analyzed by paired t test. As a result, there were statistically significant differences (t=7.21, p=0.000). Conclusion: The SUV for quantification should be measured precisely to give consistent information of tumor uptake. But PVE is one of factors that causes SUV to be lower and to be underestimated. We can correct this PVE and calculate corrected SUV using the recovery coefficient from phantom study. And if we apply this correction method to clinical patients, we can finally assess and provide quantitative analysis more accurately.

  • PDF

Wheel Balance Cancer Therapy in the Treatment of Metastatic Gastric Carcinoma : A Retrospective Analysis of 62 Patients (수레바퀴 암 치료법을 시행받은 진행성 위암환자 62명에 대한 후향적 코호트 분석)

  • Park, Jeong-Seok;Yoo, Hwa-Seung;Lee, Yeon-Weol;Cho, Jung-Hyo;Son, Chang-Gue;Cho, Chong-Kwan
    • The Journal of Internal Korean Medicine
    • /
    • v.28 no.3
    • /
    • pp.531-543
    • /
    • 2007
  • Backgrounds : Gastric cancer is one of the most frequent causes of cancer-related deaths worldwide. Gastric cancer patients frequently exhibit distant metastasis at the time of diagnosis and at present, there is no standard regimen after operation or chemotherapy to prevent metastasis and recurrences. Aims : The objective of the study was to compare the overall survival and disease free survival in patients treated with wheel balance therapy (WBT) with patients treated with WBT alone or the combination of WBT and conventional therapy and see if there were any significant improvements in survival between the two groups. Setting & Design : East-West Cancer Center at Daejeon University: retrospective study. Materials & Methods : We retrospectively analyzed 62 patients with stage III (40 patients) and stage IV (22 patients) gastric cancer who have received operation or chemotherapy 2 months prior to beginning WBT. The patients followed the WBT protocol which includes herbal medicine such as PSM capsules, OnePlus syrup, or HAD capsules which prevent metastasis and recurrences. Overall survival and disease free survival were analyzed and the patients were treated for 89.55 weeks and 49.27 weeks (median value) for stages III and IV, respectively. Statistical analysis used : Overall survival and disease free survival were estimated using the Kaplan-Meier method and the WBT and combination treatment arms were compared using the log rank test. Results : For stage III, the 3 year overall survival was 78.5% and disease free survival was 78.3%. Metastasis and recurrence occurred in 13 of 40 patients (32.5%). For stage IV, the 2 year overall survival was 18.2% and disease free survival was also 18.2%. Metastasis and recurrence occurred in 19 of 22 patients (86.4%). No significant difference was found statistically between the WBT alone and combination treatment arms though the combination regimen showed superiority (overall survival p=0.5093, disease free survival p=0.5175). Conclusions : WBT yielded satisfactory results in prolonging survival and preventing metastasis and recurrence in gastric cancer patients. The major treatment unit of WBT is composed of herbal medications (HAD, PSM capsules, OnePlus syrup) and a randomized, prospective study should be carried out using only this treatment unit in the future.

  • PDF

Qualitative Analysis of $GeO_2$ in Germanium-Fortified Yeast. (게르마늄강화효모 내의 $GeO_2$ 정성분석)

  • Kim, So-Yeun;Kim, Myoung-Hee;Woo, Hee-Gweon;Kim, Bo-Hye;Sohn, Tsang-Uk;Jung, Jin-Wook;Baek, Dae-Heoun
    • Microbiology and Biotechnology Letters
    • /
    • v.35 no.2
    • /
    • pp.163-172
    • /
    • 2007
  • This study was designed to investigate that inorganic germanium $(GeO_2)$ did not exist in germanium-fortified yeast or obtained to non-detectable value by current analytical methods and equipments. For this purpose, we achieved $GeO_2$ qualitative analysis protocol which could be the scientific basis of the study. Since reddish brown precipitate was formed from the reaction of $GeO_2$ with 1 equiv $NaBH_4$, and dark brown precipitate was also formed from the reaction of $GeO_2$ with 2 equiv $NaBH_4$, $GeO_2$ was qualitatively analyzed by observing these particular colored-precipitates. Because no color change was showed from the reaction between $NaBH_4$ and $SiO_2$, the color change could be caused by charge transfer transition on Ge-O and B binding properties. The reaction between $NaBH_4$ and germanium-fortified yeast did not show any color change and precipitate formation which meant no $GeO_2$ existed in germanium-fortified yeast. The reaction between $NaBH_4$ and supernatant specimen collected from the outside of dialysis membrane (MWCO 1,200 dalton) did not show any color change and precipitate formation. Therefore, we considered that the both germaniums in and outside of the dialysis membrane were organic germaniums. Germanium-fortified yeast which was biosynthesized organic germanium can be applied not only as a new functional material for improving health, prevention and treatment of chronic degenerative diseases including cancers, and the regulation of immune system, but also as a new materials.

Effects of specimens dimension on the flexural properties and testing reliability of dental composite resin (치과용 복합레진의 굽힘 특성과 시험 신뢰도에 미치는 시편 크기의 영향)

  • Im, Yong-Woon;Hwang, Seong-sig;Kim, Sa-hak;Lee, Hae-Hyoung
    • Korean Journal of Dental Materials
    • /
    • v.44 no.3
    • /
    • pp.273-280
    • /
    • 2017
  • The aim of the present study was to investigate the effects of specimen dimension on the flexural properties and testing reliability of dental composite resin. The composite resin was prepared experimentally by mixing a resin matrix with silanated micrometer glass filler at 50 vol%. Flexural specimens with various dimension in specimen's width were fabricated by light curing using a split metal mold; $25{\times}2{\times}2mm$, $25{\times}2{\times}4mm$, $25{\times}2{\times}6mm$ in length ${\times}$ height ${\times}$ width. The flexural strength and modulus were determined according to ISO 4049 test protocol at a span length of 20 mm (normal-flexural strength; NFS). Another flexural test was conducted using mini-sized specimens ($12{\times}2{\times}2mm$, $12{\times}2{\times}4mm$, $12{\times}2{\times}6mm$) from the broken specimens at a span length of 10 mm (mini-flexural strength; MFS). Data were analyzed with ANOVA and Duncan's post-hoc test and the test reliability was evaluated by Weibull analysis. Results showed that there are generally no significant difference in flexural strength with the increase in the specimen width in NFS and MFS tests. However, the test reliability of flexural strength based on Weibull analysis was largely changed with the variables in the dimension of width and span length. The flexural modulus of NFS was increased as the dimension of specimens width increased while there was no trend in flexural modulus of MFS test. Overall results recommend that the evaluation of flexural properties and the reliability of dental composite resins should be performed with more than one test method.