• Title/Summary/Keyword: Protocol

Search Result 13,718, Processing Time 0.04 seconds

Performance Analysis of Slot-Extension Adapt ive SECS-LExpressnet protocol (확장슬롯 적응형 SECS-LExpressnet 프로토콜의 성능 분석)

  • 유동관
    • Journal of the Korea Society of Computer and Information
    • /
    • v.8 no.2
    • /
    • pp.106-111
    • /
    • 2003
  • In this Paper, an improved protocol is proposed by supplementing a control station for transmission cycle management and slot-extension function. This protocol is proposed to complement the shortcomings of the conventional L-Expressnet protocol which is used for round robin process in bus topology. We analyzed the improved protocol in channel utilization viewpoint and compared the result with that of the conventional Protocol. From this result, we showed that the channel utilization of the improved protocol is superior to that of the conventional protocol when a maximum normalized propagation delay is increased.

  • PDF

Effects of Cotrolled Ovarian Hyperstimulation (COH) Protocols on Pregnancy and Delivery Rate in In-Vitro Fertilization and Embryo Transfer (체외수정시술시 과배란유도 방법이 임신율에 미치는 영향)

  • Hong, J.E.;Lee, J.S.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.24 no.3
    • /
    • pp.361-368
    • /
    • 1997
  • A total of 55 patients with various etiologies of infertility particitated in a study comparing two regimens of controlled ovarian hyperstimulation (COH) with GnRH agonists and gonadotropins. Nineteen patients were given an ultra-short stimulation protocol when the agonist was administered for 3 day from Day 2 of the cycle. The remaining 36 patients were given a long stimulation protocol when the agonist was administered from the mid-luteal phase of the cycle preceding the stimulation cycle. The mean number of gonadotropins used per patient was not different between two groups. No significant differences were found in the mean number of oocytes recovered, fertilization rate and embryo cleavage rate between two groups. Pregnancy and delivery rates were higher in ultra-short protocol than in long protocol, but these were not significant. These results suggest that an ultra-short protocol is as effective as a long protocol in in-vitro fertilization and embryo transfer.

  • PDF

Develpoment of Automatic Meter Reading Program for Electronic Power Meter (전자식 전력량계용 한전 프로토콜 및 운영 프로그램 개발)

  • Yu, In-H.;Jang, Mun-J.;Hyun, Duk-H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2219-2221
    • /
    • 2001
  • A communication protocol for automatic meter reading is designed for electronic power meter. Communicational functions and data structures are standardized and data reading software is developed according to the developed protocol. The communication protocol is designed with reference specifications, IEC 62056-31 and Distributed Network Protocol(DNP). For design, communicational functions and specifications of the industrial meters were analyzed for the purpose of developing a new one for KEPCO meters. The protocol is designed with 3 layer model, physical layers, data link layer and application layer. A documentation was completed with data gathering, data classification, authentication, error detection. An emulator system was made for testing the protocol. A meter reading software was developed using the protocol. Many different protocols and meter reading softwares are integrated into one with the developed protocol and software as KEPCO's standard.

  • PDF

Performance Analysis of Data Link Protocol for Interface between EIS and LDTS (전자연동장치와 역정보전송장치간 인터페이스를 위한 데이터링크 프로토콜 성능해석)

  • Hwang, Jong-Gyu;Lee, Jae-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.6 no.2
    • /
    • pp.135-141
    • /
    • 2003
  • According to the computerization of railway signaling systems, the interface link between these signaling equipment is also replaced by digital communication channel, expecially communication link for interface between EIS and LDTS, but there are some problems in the present state of railway signaling. First of all, different communication protocol is applied to interface between above two signaling equipment although they have same functions. The other is that the communication protocol currently used in railway field has some unreasonable points such as structure, formation of byte, error correction scheme and etc. To solve these problems, the standard communication protocol for railway signaling is designed. The structure of designed communication protocol and the results of performance analyses are represented in this paper. It will be expected the increase of safety, reliability and efficiency of maintenance of signaling system by using of the designed communication protocol for railway signaling.

Development and Evaluation of an Evidence-Based Nursing Protocol for Fever Management in Adult Patients (성인 발열 환자를 위한 근거기반 간호 지침 개발 및 평가)

  • Shin, Yong Soon;Kim, Sung Reul;Yoo, Sung-Hee;Kim, Sun Hwa;Kim, Jeoung Hee;Kim, Hyun Jung;Na, Ra;Chae, Jee Sun;Lee, Hye Jin;An, Young Hee;Kim, Kyoung-Ok
    • Korean Journal of Adult Nursing
    • /
    • v.25 no.3
    • /
    • pp.250-262
    • /
    • 2013
  • Purpose: This study was designed to develop, to implement and evaluate a fever management nursing protocol for adult patients. Methods: This study was conducted through seven steps following both the guideline development procedures of the Scottish Intercollegiate Guidelines Network and the Model of the Asan Medical Center Evidence-Based Practice, as follows: 1) identifying the clinical needs and composition of the protocol development group; 2) identifying and evaluating the evidence; 3) assessing the level of evidence and grading recommendations; 4) forming a protocol; 5) evaluating the protocol using an expert group validity test and identifying barriers to its implementation; 6) protocol development; and 7) evaluation of practical improvement measures following implementation of the protocol. Results: The evidence-based protocol for fever management in adult patients was completed and includes five domains and 15 items. The protocol had good content validity (CVI=.90) and nursing practice could be improved after implementation of the protocol. Conclusion: This nursing protocol can be used as a guide for nursing in febrile adult patients. We recommend that further guidelines be updated in an interdisciplinary manner in order to foster local adaptation of the best clinical practices.

Lower bound on the Number of Rounds for Optimistic Multi-party Contract Signing Protocol (낙관적 다자간 계약서 서명 프로토콜 라운드의 하한)

  • Joo, Hong-Don;Chang, Jik-Hyun
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.32 no.10
    • /
    • pp.499-506
    • /
    • 2005
  • The growth of networks increase the importance of electronic commerces. Since the fair exchange protocol is an important part of electronic commerces, a number of researches have been done in relation to the fair exchange protocol. As the contract signing protocol is a part of fair exchange protocol, many protocols have been proposed, but most of them were focused on two-party protocol. Only a few were on the multi-party contract signing protocol. So far the optimistic multi-party contract signing protocol presented by Baum-Waidner has the least number of rounds in asynchronous network[4]. But, the lower bound on the number of rounds required by any optimistic multi-party contract signing protocol has been not known. In this paper, we present a tight lower bound on the number of rounds for optimistic multi-party contract signing protocol.

Implementation of An Efficient Reader Protocol for Active RFID Readers (능동형 RFID 리더를 위한 효율적인 리더 프로토콜의 구현)

  • Moon, Young-Sik;Chung, Sang-Hwa
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.8B
    • /
    • pp.822-829
    • /
    • 2009
  • A reader protocol is an interface between a host and RFID readers. There are several standards for reader protocol such as EPCglobal Low Level Reader Protocol (LLRP) 1.0.1, EPCglobal Reader Protocol (RP) 1.1, and ISO/IEC 15961/15962. Unfortunately, these standards focus on the passive RFID system, and so they are not appropriate for the active RFID system. In this paper, we implemented an efficient reader protocol for the active RFID system, which is based on EPCglobal LLRP 1.0.1, but smoothing/filtering functions of EPCglobal RP 1.1 are added. This protocol is designed to configure air interface parameters for active RFID readers and tags. It can reduce the amount of data transfer between the reader and host by filtering function, and can improve the performance of tag collection by smoothing function. In addition, it can remove inefficiency caused by tag memory data change according to the standards of ISO/IEC 15961/15962. In the real-world environment, we evaluated the performance of our implemented reader protocol using one RFID reader and 45 tags.

Symmetric Tree Replication Protocol for Efficient Distributed Storage System (효율적인 분산 저장 시스템을 위한 대칭 트리 복제 프로토콜)

  • 최성춘;윤희용;이강신;이호재
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.9
    • /
    • pp.503-513
    • /
    • 2004
  • In large distributed systems, replications of data and service are needed to decrease communication cost, increase availability, and avoid single server bottleneck. Tree Quorum protocol is a representative replication protocol, which exploits a logical structure. Tree quorum protocol is one of the replication protocols allowing low read cost only in the best case, while the number of replicas exponentially increases as the level grows. In this paper, thus, we propose a new replication protocol, called symmetric tree protocol which efficiently solves the problem. The proposed symmetric tree protocol also requires much smaller read cost than previous protocols. We conduct cost and availability analysis of the protocols, and the proposed protocol displays comparable read availability to the tree protocol using much smaller number of nodes. Also, the symmetric tree protocol has much smaller response time than the logarithmic protocol.

Algebraic Formal Specification and Formal Validation of the Standard and an Implementation of the OSPF Protocol (OSPF Protocol 표준 및 구현의 대수 정형적 명세 및 정형적 검증)

  • 박재현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.3B
    • /
    • pp.360-374
    • /
    • 2004
  • The OSPF protocol is the most widely used Interior Gateway Routing Protocol. Therefore, for the reliability of behavior of gigabit swiching routers, it is essential to guarantee the interoperability and the safety of the OSPF protocol. In this paper, we analyze the standard document of the OSPF protocol, so that we provide a formal specification that specifies the protocol behaviors by detailed design level using the algebraic formal method. By referring available source codes of the OSPF protocol, we supplement the formal specification to express more detailed behaviors that is not specified definitely in the standard. We also formally verify the interoperability and the safety of the protocol state machine of the specification. By showing that the formal specification specify all of the states and the transition events that appear in the standard document of the OSPF protocol, we prove that the state machine has the completeness, and prove it has the interoperability. To prove that the specification of the protocol has the safety, we formally verify the reachability, the liveness, the livelock-free property, and the deadlock-free property. As a result, we prove the protocol has the consistency. The specification and the validation are also effective to the OSPF Version 3 that inherit the protocol mechanism of the OSPF Version 2.

The effects of knee joint position sense following local and general load protocols (국소적 부하와 전신적 부하가 슬관절 위치 감각에 미치는 영향)

  • Hwang, Yoon-Tae;Park, Rae-Joon;Choi, Jin-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.3
    • /
    • pp.429-440
    • /
    • 2005
  • The purpose of this study was to compare the effects of knee joint position sense following local and general load protocols in 25 healthy male subjects. Proprioception of the knee joint was evaluated by measuring absolute angular errors at matching angles before, after and between 2 different types of load protocols. Proprioception tests(on the dominant knee) were performed in which proprioception of the passivepassive reproduced and active-active reproduced knee position was measured. Local load was provided with maximum isokinetic knee extension-flexion on the isokinetic dynamometer(Cybex), and general load was 10 minutes running on a treadmill. Peak torque(knee extension and flexion) and heart rate(beats per minute) was evaluated as an indicator of local and general fatigue during load protocols. The results were as follows: 1. For pasive-pasive reproduced knee position test, significant difference in absolute angular errors after general load protocol was detected compared with that before general load protocol(P<.05), significant difference in absolute angular errors after local load protocol was detected compared with that before local load protocol(P<.05). However, no significant difference in absolute angular errors of general load protocol was detected compared with that of local load protocol (P>.05), no significant difference in absolute angular errors of local load protocol was detected compared with that of general load protocol(P>.05). 2. For active-active reproduced knee position test, significant difference in absolute angular errors after general load protocol was detected compared with that before general load protocol(P<.05), significant difference in absolute angular errors after local load protocol was detected compared with that before local load protocol (P<.05). Also, significant difference in absolute angular errors of general load protocol was detected compared with that of local load protocol(P<.05), significant difference in absolute angular errors of local load protocol was detected compared with that of general load protocol(P<.05). 3. A significant decrease of peak torque of knee extensors and flexors was seen after local load, although heart rate was significantly increased(P<.05). No significant change of peak torque of knee extensors and flexors was seen after general load(P>.05), although heart rate was also significantly increased(P<.05). The previous study revealed that knee proprioception is significantly altered when the muscle mechanoreceptors are dysfunctional due to muscle fatigue, although the joint mechanoreceptors have no significantly effect on knee proprioception when the presence of knee muscle fatigue. However, the results of this study are different from those of the previous study in that muscle weakness of the knee could not be seen after general load. This study shows that general load may diminish motor control by the central nervous system. Proprioceptional decline without muscle weakness of knee after general load suggests a change in the proprioceptional pathway without influence from muscle mechanoreceptors.

  • PDF