• 제목/요약/키워드: Protective Coordination

검색결과 119건 처리시간 0.022초

An Autonomous Optimal Coordination Scheme in a Protection System of a Power Distribution Network by using a Multi-Agent Concept

  • Hyun, Seung-Ho;Min, Byung-Woon;Jung, Kwang-Ho;Lee, Seung-Jae;Park, Myeon-Song;Kang, Sang-Hee
    • KIEE International Transactions on Power Engineering
    • /
    • 제2A권3호
    • /
    • pp.89-94
    • /
    • 2002
  • In this paper, a protection system using a Multi-Agent concept for power distribution networks is proposed. Every digital over current relay(OCR) is developed as an agent by adding its own intelligence, self-tuning and communication ability. The main advantage of the Multi-Agent concept is that a group of agents work together to achieve a global goal which is beyond the ability of each individual agent. In order to cope with frequent changes in the network operation condition and faults, an OCR agent, suggested in this paper, is able to detect a fault or a change in the network and find its optimal parameters for protection in an autonomous manner considering information of the whole network obtained by communication between other agents. Through this kind of coordination and information exchanges, not only a local but also a global protective scheme is completed. Simulations in a simple distribution network show the effectiveness of the suggested protection system.

배전계통의 보호협조측면에서 본 분산전원 연계용량 검토 (Interconnection Capacity Evaluation of Distributed Resources at the Distribution Networks in View of Distribution Protection Coordination)

  • 최준호;노경수;박성준;송경빈;윤상윤
    • 조명전기설비학회논문지
    • /
    • 제21권3호
    • /
    • pp.107-116
    • /
    • 2007
  • 정부의 신 재생 에너지 관련 정책으로 인해 앞으로 국내에서 신 재생에너지원은 보급은 증가할 것으로 예상된다. 신 재생에너지원은 전원의 특성상 전력계통에 연계되어 운전하는 것이 일반적이지만 이러한 연계 운전은 전력계통 계획 및 운영상에 상당한 영향을 미치게 된다. 기존 배전계통의 전력조류는 변전소에서 수용가를 향한 단방향이며 이를 기반으로 계통운영이 이루어지고 있으나, 신 재생에너지원의 연계로 배전계통에 양방향의 전력조류가 형성되므로 기존의 보호시스템의 신뢰성 및 전력품질이 저하될 수 있다. 따라서 신 재생에너지원의 연계평가에 대한 기술적 평가절차가 필요하다. 본 논문에서는 국내 배전계통의 전형적인 보호기기인 자동 재폐로 차단기와 구분개폐기의 특성을 살펴보고, 현재의 자동재폐로 차단기-구분개폐기 보호시스템에서 분산전원의 연계용량을 검토하는 방안을 제시하고자 한다.

Positive Offset Mho 계자 상실 계전기 보호 협조 정정에 관한 연구 (A Study on Protective Coordination Setting of Positive Offset Mho Loss of Field Relay)

  • 김광현;박지경;김준혁;김두웅;강성범;김철환;유영식;양정재;고윤태
    • 전기학회논문지
    • /
    • 제65권8호
    • /
    • pp.1326-1333
    • /
    • 2016
  • It is important to clear the fault and prevent resulting in damage to power system. Although the frequency of generator internal fault is relatively low, it can lead to incalculable damage to power system as well as generator. Especially, loss of field on generator can cause the generator to lose synchronism for a short time if it is not removed promptly. Therefore, it is needed to conduct research on loss of field relay for detecting or clearing the loss of field. However, the setting of the relay may vary in generator operator or engineer, and the relay is not coordinated well with other elements associated with loss of field. In this paper, we address specifically the coordination of positive offset mho loss of field relay which is one of the protection schemes for loss of field. Computer simulations are performed by using ElectroMagnetic Transients Program-Restructured Version (EMTP-RV) based on actual data.

Study on Application of Superconducting Fault Current Limiter Considering Risk of Circuit Breaker Short-Circuit Capacity in a Loop Network System

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1789-1794
    • /
    • 2014
  • This paper suggests an application method for a superconducting fault current limiter (SFCL) using an evaluation index to estimate the risk regarding the short-circuit capacity of the circuit breaker (CB). Recently, power distribution systems have become more complex to ensure that supply continuously keeps pace with the growth of demand. However, the mesh or loop network power systems suffer from a problem in which the fault current exceeds the short-circuit capacity of the CBs when a fault occurs. Most case studies on the application of the SFCL have focused on its development and performance in limiting fault current. In this study, an analysis of the application method of an SFCL considering the risk of the CB's short-circuit capacitor was carried out in situations when a fault occurs in a loop network power system, where each line connected with the fault point carries a different current that is above or below the short-circuit capacitor of the CB. A loop network power system using PSCAD/EMTDC was modeled to investigate the risk ratio of the CB and the effect of the SFCL on the reduction of fault current through various case studies. Through the risk evaluations of the simulation results, the estimation of the risk ratio is adequate to apply the SFCL and demonstrate the fault current limiting effect.

저압차단기기의 보호협조 (The Protective Co-ordination between Low-Voltage Circuit-Breaker)

  • 박성찬;오준식;이방욱;유만종;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.340-343
    • /
    • 2001
  • In an electrical network, electrical power are transmitted by a various of protection, isolation and control electric circuit devices. This thesis deals with the protection function between circuit-breakers. The protective coordination concerns the behaviour of two devices placed in series in an electrical network, with a short-circuit downstream circuit-breaker. It has two basic principles: First, discrimination which is an increasing requirement of low voltage electrical distribution systems. Second, which is less well known: cascading, which consists of installing a device, whose breaking capacity is less than the three-phase short-circuit current at its terminals and helped by main circuit-breaker. The important advantage of cascading is to be able to install at a branch circuit-breaker of a lesser performance without endangering the safety of the installation for more economical usage. To determine and guarantee co-ordination between two circuit breakers, it is necessary to carry out a theoretical approach, first, and then confirm the results by means of standard tests. This is illustrated in appendix A of IEC 947-2.

  • PDF

저압용 서지 보호 장치(SPD)의 보호 거리 해석 (Analysis of the Protective Distance of Low-Voltage Surge Protective Device(SPD) to Equipment)

  • 이정우;오용택
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.28-34
    • /
    • 2012
  • Installing surge protection devices for a low-voltage system is important to ensure the survival of electric or electronic devices and systems. If surge protection devices (SPD) are installed without consideration of the concept of lightning protection zones, the equipment to be protected might be damaged despite the correct energy coordination of SPDs. This damage is induced by the reflection phenomena on the cable connecting an external SPD and the load protected. These reflection phenomena depend on the characteristics of the output of the external SPD, the input of the loads, and the cables between the load and the external SPD. Therefore, the SPD has an effective protection distance under the condition of the specific load and the specific voltage protection level of SPD. In this paper, PSCAD/EMTDC software is used to simulate the residual voltage characteristics of SPD Entering the low-voltage device. And by applying a certain voltage level, the effective protection distances of SPD were analyzed according to the each load and length of connecting cable, and the effectiveness of SPD were verified.

2단 종속 SPD시스템의 보호특성 (Protection Characteristics of Two-Stage Cascade SPD Systems)

  • 이복희;신희경
    • 조명전기설비학회논문지
    • /
    • 제27권5호
    • /
    • pp.95-103
    • /
    • 2013
  • Protection of the electrical and electronic equipment against surges in low voltage AC power distribution systems is based on wide applications of surge protective devices(SPDs). Cascade application of SPDs located at the service entrance of a building and near sensitive equipment is intended to ensure the optimal voltage protection level and energy sharing among cascade SPDs. In this paper, when surges impinge at the service entrance of the building of interest, the protection characteristics of two-stage cascade SPD systems were investigated. The influence of the distance between the upstream and downstream SPDs on the voltage protection level and energy sharing of the two-stage cascade SPD systems were analyzed experimentally. It was found that the energy sharing of two-stage cascade SPD systems strongly depends on the distance between the two SPDs and the component of SPD. As the distance between the two SPDs increases, the energy absorbed by the upstream SPD increases while the energy absorbed by the downstream SPD decreases. Consequently, it is desirable to select the upstream and downstream SPDs having the proper energy capability with due consideration of the distance between the two SPDs.

초전도 한류기 적용시 소형 분산전원시스템의 연계 위치에 따른 배전계통의 전압강하 분석 (Analysis on Bus Voltage Sag in Power Distribution System with SFCL according to Interconnected Locations of Small DG)

  • 문종필;손진근
    • 전기학회논문지P
    • /
    • 제62권4호
    • /
    • pp.210-215
    • /
    • 2013
  • This paper analyze the bus voltage sags in the power distribution system with a small scale cogeneration system when the superconducting fault current limiter was introduced. Among the solutions to decrease the short-circuit current considering the locations of the small scale cogeneration system, the superconducting fault current limiter (SFCL) has been announced as one of the promising methods to reduce the fault current because the installation of the small scale cogeneration system which increases the short-circuit current. According to the application locations of the small scale cogeneration system in a power distribution system, it has caused the variations of voltage sag and duration which depends on the change of the short-circuit current, which can make the operation of the protective device deviate from its original set value when the fault occurs. To investigate the voltage sag when a SFCL was applied into a power distribution system where the small scale cogeneration system was introduced into various locations, the SFCL, small scale cogeneration system, and power system are modeled using PSCAD/EMTDC. In this paper, the effects on voltage sags are assessed when the SFCL is installed in power distribution system with various locations of the small scale cogeneration system.

유해화학물질 취급자의 개인보호구 착용에 대한 규정과 그 이행정도 (Regulations on Wearing Personal Protective Equipment by Hazardous Chemical Handlers and Their Implementation)

  • 한돈희;박민수;조용성;이청수
    • 한국환경보건학회지
    • /
    • 제47권1호
    • /
    • pp.101-109
    • /
    • 2021
  • Objectives: The objectives of this study are to introduce the development process of work situations and types in the revised regulations on wearing personal protective equipment (PPE) for hazardous chemical handlers, analyze the implementation of the regulations, and then provide basic data for future education strategies. Methods: The development process of work situations for regulation was explained through a flowchart by year. In 2018, a survey of 30 chemical managers and 201 managers and handlers was conducted based on recognition of work situations and the related regulations. In 2019, 91 chemical managers and 204 handlers were surveyed to find the degree of compliance with regulations, direction for improvement of understanding the regulations, and training methods. Results: Only 78.0% of chemical managers and 66.7% of handlers said they were aware of the regulations (p<0.05). Just 79.0% of handlers knowing the regulations said they would wear PPE in compliance with these regulations. Therefore, the best way to make workers wear proper PPE in accordance with regulations is to strengthen the promotion of education on regulations. In order to improve the quality of education, 51.7% of managers and 33.3% of handlers cited educational content (video, ppt, etc.) as the top priority. Conclusion: This study suggested that more educational opportunities should be provided and educational content should be developed in order for workers handling hazardous chemicals to wear PPE as prescribed in regulations.

AC and DC Microgrids: A Review on Protection Issues and Approaches

  • Mirsaeidi, Sohrab;Dong, Xinzhou;Shi, Shenxing;Wang, Bin
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2089-2098
    • /
    • 2017
  • Microgrid is a convenient, reliable, and eco-friendly approach for the integration of Distributed Generation (DG) sources into the utility power systems. To date, AC microgrids have been the most common architecture, but DC microgrids are gaining an increasing interest owing to the provision of numerous benefits in comparison with AC ones. These benefits encompass higher reliability, power quality and transmission capacity, non-complex control as well as direct connection to some DG sources, loads and Energy Storage Systems (ESSs). In this paper, main challenges and available approaches for the protection of AC and DC microgrids are discussed. After description, analysis and classification of the existing schemes, some research directions including coordination between AC and DC protective devices as well as development of combined control and protection schemes for the realization of future hybrid AC/DC microgrids are pointed out.