• 제목/요약/키워드: Protection setting

검색결과 248건 처리시간 0.037초

A Novel Procedure for Protection Setting in an HVDC System Based on Fault Quantities

  • Gao, Benfeng;Zhang, Ruixue;Zhang, Xuewei
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.513-521
    • /
    • 2017
  • HVDC protection setting is difficult to be calculated analytically because of its strong nonlinearity. The currently used setting method is based on the empirical setting of previous projects and then verified by digital simulation. It entails a huge workload and low efficiency. To facilitate protection setting, this paper systematically summarizes the HVDC protection characteristics and then presents a classification of HVDC protections according to the protection principles. On the basis of the fault quantities, a novel setting procedure suitable for travelling wave protection, derivative and level protection, and differential protection is proposed. The proposed procedure is illustrated and verified in detail with the example of travelling wave protection. An HVDC protection setting system that has the functions of automatic protection setting and data management is developed utilizing the C# programming language.

Setting Considerations of Distance Relay for Transmission Line with STATCOM

  • Zhang, Wen-Hao;Lee, Seung-Jae;Choi, Myeon-Song
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권4호
    • /
    • pp.522-529
    • /
    • 2010
  • Distance relay plays an important role in the protection of transmission lines. The application of flexible AC transmission systems (FACTS) devices, such as the static synchronous compensator (STATCOM), could affect the performance of the distance relay because of compensation effect. This paper analyzes the application of distance relay on the protection of a transmission line containing STATCOM. New setting principles for different protection zones are proposed based on this analysis. A typical 500 kV transmission system employing STATCOM is modeled using Matlab/Simulink. The impact of STATCOM on distance protection scheme is studied for different fault types, fault locations, and system configurations. Based on simulation results, the performance of distance relay is evaluated. The setting principle can be verified for the transmission line with STATCOM.

Analysis of Stability of PV System using the Eigenvalue according to the Frequency Variation and Requirements of Frequency Protection

  • Seo, Hun-Chul;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권4호
    • /
    • pp.480-485
    • /
    • 2012
  • Use of photovoltaic (PV) power generation system will become more widespread in the future due to anticipated cost reduction in PV technology. As the capacity of PV systems increases, a variation of power system frequency may prevent the stable output of PV system. However, the standard for the frequency protection of distributed generation in Korea Electric Power Corporation (KEPCO)'s rule does not include the setting of frequency protection. Therefore, this paper analyzes the correlation between the frequency protection requirements and the stability of grid-connected PV system for the adjustable operating setting of frequency protection. The distribution system interconnected with 3 MW PV system is modeled by Matlab/Simulink. The various values of frequency are simulated. For studied cases, the stability of PV system is analyzed. It is concluded that the setting of frequency protection is necessary to consider the stability of PV system.

Faultless Protection Methods in Self-Healing Ethernet Ring Networks

  • Lee, Kwang-Koog;Ryoo, Jeong-Dong;Joo, Bheom Soon
    • ETRI Journal
    • /
    • 제34권6호
    • /
    • pp.816-826
    • /
    • 2012
  • Self-healing Ethernet rings show promise for realizing the SONET/SDH-grade resilience in Carrier Ethernet infrastructures. However, when a ring is faulty, high-priority protection messages are processed in less time than low-priority data frames are processed. In this situation, any delayed data frames either being queued or traveling through long ring spans will cause the ring nodes to generate incorrect forwarding information. As a result, the data frames spread in the wrong direction, causing the ring to become unstable. To solve this problem, we propose four schemes, that is, dual flush, flush delay timer setting, purge triggering, and priority setting, and evaluate their protection performance under various traffic conditions on a ring based on the Ethernet ring protection (ERP) method. In addition, we develop an absorbing Markov chain model of the ERP protocol to observe how traffic congestion can impact the protection performance of the proposed priority setting scheme. Based on our observations, we propose a more reliable priority setting scheme, which guarantees faultless protection, even in a congested ring.

태양광 연계 계통의 주파수 보호 기준 정립 (The Frequency Protection of Distribution System with Photovoltaic System)

  • 서훈철;김철환;윤영민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.440_441
    • /
    • 2009
  • The standard for the frequency protection of distributed generation in Korea Electric Power Corporation (KEPCO)'s standard doesn't include the setting of frequency protection. Therefore, this paper analyzes the correlation between the frequency protection requirements and the stability of grid-connected PV system for the adjustable operating setting of frequency protection. The distribution system interconnected with 3 MW PV system is modeled by Matlab/Simulink. The various value of frequency is simulated. For studied cases, the stability of PV system is analyzed. It is concluded that the operating setting of frequency protection can be determined by the stability of PV system.

  • PDF

Automatic Protection Schemes for Distribution System with Open and Closed-loop

  • Guan, Kang-Le;Lee, Seung-Jae;Choi, Myeon-Song
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.969-974
    • /
    • 2013
  • Protection issues in distribution systems which are to be operated in open and closed-loop modes in a smart grid are studied and a generalized protection setting method is proposed to meet the new requirements. The developed setting method assumes a conventional over-current protection scheme for the system with reclosers and over-current relays. In a closed-loop mode, it identifies protective devices that have to be sacrificed in order to maximize protection coordination for bidirectional fault current flow. The proposed setting method has been tested on many systems with different complexity and is proved effective.

Multi-Agent 기반의 배전계통 보호협조 알고리즘 (Multi-Agent based Distribution Protection Coordination Algorithm)

  • 임일형;최면송;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.4_5
    • /
    • 2009
  • A new protection coordination algorithm in Multi-Agent based distribution automation system is proposed in this paper. Distribution network protection coordination is acted by normal state distribution operation. But, in more and more complex distribution network structure, it has a big problem that central server processed all measurement data, coordination setting and controls for operation. So, a algorithm to change coordination setting is proposed automatically in terminal devices which Recloser and OCR to include Multi-Agent concepts in distribution network.

  • PDF

전력시스템 보호를 위한 웹기반 계전기 정정 프로그램 개발 (Development of Web-based Protection Relay Setting Program in Power System)

  • 복정송;정호성;신명철;조인숙;서희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.246-248
    • /
    • 2001
  • For protection of power system, it is a prerequisite to action characteristics of protective relay about a changing environment in power system and correcting the setting value. A substation operator always reside to correct of a relay, however there are problem of efficiency. Recently, power system operation become manless and supervision and control of incident is required anywhere, introduction of new concept as a intellectual manless protective relay is a recent trend. This paper is the web-based protective relay setting program that a manager make an analysis of operation and incident of power system through the web at a remote place corresponding recent manless of system and approach the protection relay and then can correct the error.

  • PDF

발전기 보호제어를 위한 Bay Controller 설계에 관한 연구 (A Study on the Design of the Bay Controller for Generator Protection and Control)

  • 장낙원;우천희;이성환
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.46-55
    • /
    • 2008
  • In this paper, we designed the bay control unit that is based on the microprocessors and integrates with the new technology of electrical, electronic, and mechanical fields. Nowadays the customers have required much more integrated multi-protection relay, monitoring, control devices and power management for better and easier maintenance, performance, electrical system analysis and communication according to new trend of switchboard This bay controller supplies those requirements of customers with easy handling and operation. This bay controller provides a graphic display with rear-lit liquid crystal LCD and push buttons as kinds of HMI(Human Machine Interface). This bay controller provides the parameter setting program, control setting program, various editors and fault recording and analysis program on Windows/95/98/NT/2000/XP for HMI. In addition, this bay controller can be set manually and this manual setting function helps user to interface easily.

루프 배전계통에서 Agent를 이용한 보호협조 및 자동정정 방법에 관한 연구 (A Study on the Protective Coordination and Automatic Setting Method using Agents in Distribution System with Loop)

  • 진영택;이승재;최면송;임성일;김태완
    • 전기학회논문지
    • /
    • 제61권8호
    • /
    • pp.1107-1114
    • /
    • 2012
  • In this paper, we propose protective coordination and automatic setting method using agents for distribution system with loop. The proposed protection scheme adopts an agent technology assuming communication among protection agents and auto-switch agents. Having exchanged fault-related information with each other, protection agents and auto-switch agents perform the primary and backup protection and fault section isolation, respectively. this proposed scheme using agents for distribution system with loop is implemented by matlab. Because of the various configuration of distribution system, It's difficult to find cooperative agents for each agent. This paper develops a program to automatically set the cooperative route for the agents.