• Title/Summary/Keyword: Protection algorithm

Search Result 820, Processing Time 0.029 seconds

A Novel Audio Watermarking Algorithm for Copyright Protection of Digital Audio

  • Seok, Jong-Won;Hong, Jin-Woo;Kim, Jin-Woong
    • ETRI Journal
    • /
    • v.24 no.3
    • /
    • pp.181-189
    • /
    • 2002
  • Digital watermark technology is now drawing attention as a new method of protecting digital content from unauthorized copying. This paper presents a novel audio watermarking algorithm to protect against unauthorized copying of digital audio. The proposed watermarking scheme includes a psychoacoustic model of MPEG audio coding to ensure that the watermarking does not affect the quality of the original sound. After embedding the watermark, our scheme extracts copyright information without access to the original signal by using a whitening procedure for linear prediction filtering before correlation. Experimental results show that our watermarking scheme is robust against common signal processing attacks and it introduces no audible distortion after watermark insertion.

  • PDF

An Algorithm for Transfer Capability Evaluation in Power Systems with FACTS Device (FACTS적용계통에서의 송전용량 평가 알고리즘)

  • Yoon, Yong-Beum;Yoon, Jong-Su;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.880-883
    • /
    • 1998
  • In this paper, sensitivity based approach to estimate BITC(bilateral interchange transfer capacity) considering the real power flow control function of FACTS device is presented. The real power flow setting of the FACTS device is adjusted so that it transfer the power flow from the first violation point of transmission capacity to other transmission lines in the power system, thus allowing more power to be transferred from the specified generator bus to the specified load bus. The transfer between the two bus locations is increased from this new operating condition until a violation of transmission capacity limits occurs or until the setting of the FACTS device can no longer be adjusted. The proposed algorithm is illustrated using examples of small and real life power system.

  • PDF

Design of DRM Frame for Digital Contents Protection in Network (네트워크 상에서 디지털 콘텐츠 보호를 위한 DRM 프레임 설계)

  • Kim Jong-Woo;Han Seung-Jo;Yang Won-Il
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.16 no.3
    • /
    • pp.101-113
    • /
    • 2006
  • This study is intended to provide more secure contents authentication and user authentication by applying public key algorithm and hardware binding to the DRM system. The proposed system is capable of protecting distributed contents and copyrights as well as resetting any interoperability issues among those involved in transparent and secure contents distribution. The proposed algorithm also affords transparency in the DRM distribution system and protection from unauthorized distribution.

A New Protection Strategy of Impressed Current Cathodic Protection for Ship

  • Oh, Jin-Seok;Kim, Jong-Do
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.592-596
    • /
    • 2004
  • Corrosion is never avoided in the use of materials with various environments. The underwater hull is normally protected against rusting by several coatings of anti-corrosive paint. The purpose of ICCP(Impressed Current Cathodic protection) system is to eliminate the rusting or corrosion, which occurs on metal immersed in seawater. The anode of ICCP system is controlled by an external DC source with converter. The function of anode is to conduct the protective current into seawater. The proposed algorithm includes the harmonic suppression control strategy and the optimum protection strategy and has tried to test the requirement current density for protection, the influence of voltage, the protection potential. This paper was studied the variation of potential and current density with environment factors, time and velocity, and the experimental results will be explained.

A Study on Improving of Fault Recognition Method in Distribution Line (배전선로 고장인지 방식에 관한 연구)

  • Lee, Jin;Park, Chan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.1
    • /
    • pp.65-69
    • /
    • 2020
  • The aim of this study is to improve the fault decision ability of FRTU (Feeder remote terminal unit) in DAS (Distribution automation system). FRTU uses the FI (Fault indicator) algorithm based on fault current pickup and operation of the protection device. Even if the inrush current flows or the protection device is sensitive to the transient current, FRTU may indicate incorrect fault information. To address these problems, we propose an improved fault recognition algorithm that can be applied to FRTU. We will detect a specific wave that is indicative of a fault, and use this information to identify a fault wave. The specific wave-detection algorithm is based on the duration and periodicity of the voltage, current, and harmonic variations. In addition, we propose fault recognition algorithms using voltage factor variation analysis and DWT (Discrete wavelet transform). All the wave data used in this study were actual data stored in FRTU.

A Study on the Algorithm for Fault Discrimination in Transmission Lines using Neural Network and the Variation of Fault Currents (신경회로망과 고장전류의 변화를 이용한 고장판별 알고리즘에 관한 연구)

  • Yeo, Sang-Min;Kim, Cheol-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.8
    • /
    • pp.405-411
    • /
    • 2000
  • When faults occur in transmission lines, the classification of faults is very important. If the fault is HIF(High Impedance Fault), it cannot be detected or removed by conventional overcurrent relays (OCRs), and results in fire hazards and causes damages in electrical equipment or personal threat. The fast discrimination of fault needs to effective protection and treatment and is important problem for power system protection. This paper propolsed the fault detection and discrimination algorithm for LIFs(Low Impedance Faults) and HIFs(High Impedance Faults). This algorithm uses artificial neural networks and variation of 3-phase maximum currents per period while faults. A double lines-to-ground and line-to-line faults can be detected using Neural Network. Also, the other faults can be detected using the value of variation of maximum current. Test results show that the proposed algorithms discriminate LIFs and HIFs accurately within a half cycle.

  • PDF

Design of Cap Inspection Algorithm of Fuse Cap (퓨즈 캡의 검사를 위한 알고리즘 설계)

  • Ban, Gi-Jong;Won, Young-Jin;Lim, Seung-Ha
    • 전자공학회논문지 IE
    • /
    • v.47 no.4
    • /
    • pp.28-33
    • /
    • 2010
  • In this paper, we proposed to the inspection algorithm for cap, Electric fuse is an over current and circuit protection device which is occurred in electric & electronic appliance. Also the fuse are protection the second hazard at arc etc. Fuse are interest regarding a safety increased. Consequently, the fuse came to be very important. Cap inspection algorithm is designed for the cap of fuse. CCD camera is monitering the solder of cap distribution map. The conditioning of fuse cap; suming all searching data with non solder area. the area is bigger reference data then the cap is bad cap.

An Adaptive Reclosing Technique Considering the Distributed Generation (분산전원을 고려한 적응적 재폐로 기법)

  • Seo, Hun-Chul;Kim, Chul-Hwan;Yeo, Sang-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.227-232
    • /
    • 2007
  • The autoreclosing is applied to power system for maintaining system stability and continuity of supply. Developments on distributed generation(DG) grows significantly by environmental issues and economical issues. If the DG is connected to distribution system, the DG influences the technical aspects such as power quality, protection and stability. It causes the challenges to protection, especially to reclosing. In order to achieve reliability and safety of the distribution system, the rules and guidelines suggest that the DG units should be rapidly disconnected from the network before the reclosing. If the DG is disconnected whenever the fault occurs, it cannot be utilized effectively. This paper presents the adaptive reclosing algorithm considering the DG. The algorithm consists of angle oscillation's judgment, EEEAC(Emergency Expanded Equal-Area Criterion), calculation of optimal reclosing time and re-connection algorithm. The simulation is implemented for the DG technology by using EMTP MODELS. The simulation results show that the transient stability is maintained and the DG is protected against disturbance.

Phase Selection Algorithm using Sequence Voltages for Transmission Line Protection (대칭분 전압을 이용한 송전선로 보호용 고장상 선택 알고리즘)

  • Lee, Myoung-Soo;Kim, Soo-Nam;Lee, Jae-Gyu;You, Seok-Ku
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.124-126
    • /
    • 2001
  • A reliable fault type identification (phase selection) plays a very important role in transmission line protection, particularly in Extra High Voltage(EHV) networks. The conventional fault type identification algorithm used the phase difference between positive and negative sequence current excluding load current. But, it is difficult to pick out only fault current since we can not know when a fault occurs and identify the fault type in weak-infeed conditions that dominate zero-sequence current in phase current. The proposed algorithm can identify the accurately fault type using the sum of unit vectors which are calculated by positive-sequence votage and negative-sequence voltage.

  • PDF

A Study on Watermark Technique for Copyright Protection of Digital Images (디지털 영상물의 저작권 보호를 위한 워터마크 기술에 관한 연구)

  • Hong, Min-Suk;Park, Kang-Seo;Chung, Tae-Yun;Shin, Joon-In;Park, Sang-Hui
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.606-608
    • /
    • 1998
  • Digital watermarking is the technique which embeds the invisible signal into multimedia data such as audio, video, images, for copyright protection, including owner identification and copy control information. In this paper, a new watermark detection algorithm by local masking cross covariance between watermarked signal and pseudo noise signal is proposed. The proposed algorithm enhances the detection probability for embedding information. Since reducing detection errors for the weak embedding signals, the algorithm improves the image quality and robusts against illegal attack to delete the embedding information and data compression applications such as JPEG and MPEGs.

  • PDF