• 제목/요약/키워드: Protection Systems

검색결과 2,301건 처리시간 0.035초

The Effect Assessment Method of Control and Protection Systems on Transient Stability of Power Systems

  • Miki, Tetsushi;Sugino, Ryuzaburou;Kono, Yoshiyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.736-740
    • /
    • 2004
  • In order to overcome the problems of simulation methods, the power system transient stability assessment method using critical fault clearing time functions has been developed. Using the above method, this paper has developed the new method which can assess accurately and efficiently the effects of control and protection systems on transient stability which is the most important characteristic to assess in power systems. At first, critical fault clearing time functions CCT(W:load) are defined by taking notice of the fact that transient stability is mainly controlled by fault clearing time and load. Next, the method to be enable to assess accurately and efficiently the effects of control and protection systems on transient stability has been newly developed by using the above functions. Finally, it has been applied to the effect assessment in the occurrence of a three-phase fault in a model power system. Results of application have been clarified its effectiveness.

  • PDF

아날로그와 디지탈 보호계통의 정상 상태 여유도 비교 (A Steady-State Margin Comparison between Analog and Digital Protection Systems)

  • Auh, Geun-Sun;Hwang, Dae-Hyun;Kim, Si-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제22권1호
    • /
    • pp.45-57
    • /
    • 1990
  • 아날로그와 디지탈 보호계통의 정상상태 여유도를 비교하였다. 비교된 예는 웨스팅하우스사의 OP Delta T 및 OT Delta T 계통과 CE사의 CPCS 계통이다. 안전해석 방법의 차이에 의한 여유도 영향을 제거하기 위해 Dynamic Offset은 고려하지 않았다. 핵연료봉 중심선의 용융을 방지하는데 있어서 디지탈 보호계통이 아날로그 보호계통보다 약 30% 출력 정도의 운전 여유도를 더 가졌다. DNB를 방지하는데 있어서는 주기말에서는 양 보호계통이 비슷한 여유를 가졌으나 주기초에서는 디지탈 보호계통이 약 10%의 더 많은 운전여유를 가지는 것으로 판단된다.

  • PDF

원자력발전소 화재방호와 소방시설 기술기준 적용에 대한 고찰 (A Study on Fire Protection in Nuclear Power Plants and Application of the Code and Standards for Fire Protection Systems)

  • 김위경;정기신
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.38-44
    • /
    • 2012
  • 원자력발전소 화재방호의 목표는 화재 시 원자로의 안전정지 상태를 유지하여 환경으로의 방사성물질 누출을 최소화하며, 종사자 인명안전 및 재산을 보호하는데 있다. 소방시설은 발생된 화재를 조기 감지 및 진압하여 화재로 인한 피해를 완화시킬 수 있는 심층방어개념에 입각한 중요한 방어수단의 하나이다. 그러나 소방방재청에서 제시하고 있는 소방시설 설치기준이 원자력발전소에 특화되어 있지 않아 인허가 시 별도의 심의 절차가 요구되고 있다. 또한, 성능위주설계와 같은 규정은 작업자의 인구밀도가 비교적 낮은 원자력발전소에 적용하는데 어려움이 있다. 이 논문에서는 원전 화재방호와 관련된 법령의 상세 검토를 통하여 도출된 근본적인 문제점과 KEPIC FPN의 국내 원전 적용성에 대한 평가를 통하여 소방시설에 대한 기술기준에 대한 개선방향을 제시하였다.

Advanced Cathodic Protection Modeling Associated with Coating Degradation Conditions

  • Im, Gwan-Jin;Kim, Ki-Joon;Lee, Myung-Hoon
    • Corrosion Science and Technology
    • /
    • 제8권5호
    • /
    • pp.177-183
    • /
    • 2009
  • There are two effective methods in use to protect ship ballast tank against corrosion. One is paint coating and the other cathodic protection(CP). The conventional cathodic protection design has mainly relied on the expert's experience. During the last two decades computer modeling has been significantly developed as an advanced design technology for cathoidic protection systems not only for ships, but also for offshore structures. However the present computer modeling of cathodic protection systems have some limitations simulating corrosion in the ballast tank with a deteriorated coating. In this study, "coating breakdown factor" considering coating degradation states with time has been attempted to improve the cathodic protection modeling using the data from literatures.

A Safety Assessment Methodology for a Digital Reactor Protection System

  • Lee Dong-Young;Choi Jong-Gyun;Lyou Joon
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권1호
    • /
    • pp.105-112
    • /
    • 2006
  • The main function of a reactor protection system is to maintain the reactor core integrity and the reactor coolant system pressure boundary. Generally, the reactor protection system adopts the 2-out-of-m redundant architecture to assure a reliable operation. This paper describes the safety assessment of a digital reactor protection system using the fault tree analysis technique. The fault tree technique can be expressed in terms of combinations of the basic event failures such as the random hardware failures, common cause failures, operator errors, and the fault tolerance mechanisms implemented in the reactor protection system. In this paper, a prediction method of the hardware failure rate is suggested for a digital reactor protection system, and applied to the reactor protection system being developed in Korea to identify design weak points from a safety point of view.

초고층 건축물의 화재안전성능 표준화 구축 (Establishment of Performance Based Design Standardization of Fire Protection Systems for High-Rise Buildings)

  • 손봉세
    • 한국재난정보학회 논문집
    • /
    • 제5권1호
    • /
    • pp.66-74
    • /
    • 2009
  • As building heights increase, so do these challenges in Korea. High-rise buildings present a variety of challenges to fire safety and protection. The fire protection technology in our country is still on a weak situation which is mainly due to the lack of concerns by the government, companies and citizen. This paper provides general guidance regarding fire-related property protection system for high-rise building performance based design. The importance of high-rise building in of the number of occupants, the value of property, and the a catastrophic loss would have on the community all warrant an increased level of protection and life safety. Because, We have to prepare a new spacial code and standard guidance for fire protection at the stage of the high-rise building design.

  • PDF

Mobile Payment Use in Light of Privacy Protection and Provider's Market Control

  • Mohammad Bakhsh;Hyein Jeong;Lingyu Zhao;One-Ki Daniel Lee
    • Asia pacific journal of information systems
    • /
    • 제31권3호
    • /
    • pp.257-276
    • /
    • 2021
  • This study investigates the factors that facilitate or hinder people to use mobile payment, especially drawing upon the theoretical perspectives on individual's privacy protection motivation and perceived market condition. Survey data (n = 200) were collected through a web-based platform and used to test a theoretical model. The results show that one's privacy protection power is formed by various individual and technological factors (i.e., perceived data exposure, self-efficacy, and response efficacy), and in turn it determines his/her intention to use mobile payment. Moreover, the relationship between privacy protection power and mobile payment use is conditional on the perceived market control by the service provider - with a perception of the high level of provider's market control, one uses mobile payment regardless of his/her privacy protection power, while under the low level of provider's market control, the decision depends on the degree of privacy protection power. The findings would help our understanding of why some people are more susceptible to mobile payment and others are not.

통풍형 화생방집단보호시설의 운용아키텍처 개발 (Development of the Operational Architecture of Ventilative Nuclear Biological Chemical Collective Protection Systems)

  • 권용수;이훈희
    • 한국군사과학기술학회지
    • /
    • 제8권4호
    • /
    • pp.41-49
    • /
    • 2005
  • This work describes the ventilative NBC CPS(Nuclear Biological and Chemical Collective Protection Systems). The operational requirements of NBC CPS is derived using systems engineering approach. The NBC CPS system operational architecture which describes the operational concept of NBC CPS is proposed using a computer aided systems engineering tool.

고객 폭력 경험, 보호제도, 모니터링제도가 근로자의 주관적 건강상태에 미치는 영향: 판매원과 전자제품수리원을 중심으로 (Effects of Customer Violence Experiences, Protection Systems, and Monitoring Systems on the Subjective Health Status of Workers: Focusing on Salespersons and Electronic Machine Repairers)

  • 정명희;이복임;백은미;정혜선
    • 한국직업건강간호학회지
    • /
    • 제30권4호
    • /
    • pp.145-155
    • /
    • 2021
  • Purpose: The purpose of this study was to examine the effects of customer violence experiences, protection systems, and monitoring systems on the subjective health status of salespersons and electronic machine repairers. Methods: A total of 934 persons were sampled nationwide, including 582 salespersons and 352 electronic machine repairers, from March 2~30, 2020 and asked to fill out a self-reported questionnaire. Results: The findings show that electronic machine repairers were more exposed to customer violence and had a weaker protection system than salespersons. They also experienced severe control from management through a monitoring system. The regression analysis revealed that verbal violence had a negative impact on the subjective health status of electronic machine repairers (p=.021). A worker protection system had significant effects on the improved subjective health status of salespersons (p=.009). Depression and fatigue had negative impacts on the subjective health status of both salespersons (depression: p<.001, fatigue: p<.001) and electronic machine repairers (depression: p<.001, fatigue: p=.002). Conclusion: These findings put a greater emphasis on the need for worker protection systems to prevent workplace violence and a health promotion program to manage depression and fatigue in workplaces.

ATSC 디지털 방송시스템과 WiBro 시스템 간 보호비 도출 연구 (Protection Ratio between ATSC Digital Broadcasting and WiBro Systems)

  • 이희수;강동훈;박효배;오왕록
    • 대한전자공학회논문지TC
    • /
    • 제46권11호
    • /
    • pp.61-65
    • /
    • 2009
  • 신규 통신시스템을 도입할 경우 인접한 주파수 대역을 사용 중인 기존 통신시스템에 대한 간섭이 일정 수준 이하가 되도록 신규 통신 시스템의 송신 전력 및 중심 주파수를 설정하여야한다. 이를 위하여 기존 통신시스템의 최저 수신 성능 기준을 만족시키는 두 시스템 간 송신 전력 비 (Power ratio)인 보호비 (Protection ratio) 도출이 필수적이다. 본 논문에서는 전산 실험을 바탕으로 ATSC (Advanced Television Systems Committee) 디지털 방송 시스템과 WiBro (Wireless Broadband Internet) 시스템 간 보호비를 도출하는 방안을 제안한다. 이를 위하여 ATSC 디지털 방송시스템의 송수신기를 모델링하고 간섭 신호로 WiBro 시스템의 송신기를 모델링하여 두 시스템 간 보호비를 도출하였다. 이 결과는 아날로그 방송 종료 후 잉여 주파수에 신규 서비스를 도입할 경우 유용하게 활용될 수 있을 것으로 예상된다.