• Title/Summary/Keyword: Protection Systems

Search Result 2,294, Processing Time 0.035 seconds

A Study of Model on File Transfer Using Public-key Cryptography (공개키 암호방식을 이용한 파일전송 모델의 연구)

  • 최진탁;송영재
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.15 no.7
    • /
    • pp.545-552
    • /
    • 1990
  • This paper is concerned with the file protection in the file transfer systems. In the existing file transfer systems, passwords are used in the protection but do not provide any data protection and can only provide some protection against unauthorized access. Even provided with this protection, we cannot be free form computer hackers. In order to achieve higher standards of protection for our privacy (protection for data themselves, authentication of senders...) analternative technical system should be developed in using of pulic key cryptography by choosing the public key method (RSA public key) in the file transfer. A new system suggested in the paper can achieve some higher standards of protection for our privacy. We a result thie system will be easily applied to various document handling systems as in the data base.

  • PDF

Protection Coordination Analysis for Distribution Systems Integrated with Distributed Generation (분산전원이 도입된 배전계통의 보호협조 해석방법)

  • Kim, Jae-Eon;Kim, Eui-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2279-2284
    • /
    • 2011
  • In most of radial distribution systems, the overcurrent protection coordination is adopted for the protection of apparatus and the improvement of electrical power system reliability. The protection coordination structure in distribution substation is composed of several circuit breakers(CB) with distribution lines originating from one substation bus under one transformer, which trip for their fault current. But sufficient analysis is necessary for the capacity of CB's in distribution systems with several distribution generations(DG). In this paper, a protection coordination method not to exceed the traditional capacity of CB's was proposed and certified through simulation by the PSCAD-EMTDC S/W.

EMTDC Model Development for Control & Protection Analysis of Co-Generation System based on On-site Characteristic Tests (현장 측정에 근거한 열병합 발전 시스템의 제어, 보호 해석용 EMTDC 모델 수립)

  • Kim, Hak-Man;Shin, Myong-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.85-91
    • /
    • 2006
  • Co-generation systems have been spreading rapidly over the past 10 years in Korea and most of these systems are interconnected with electric power systems. However, better control and protection models are still needed for analysis of these systems to ensure stable operation with the grid. This paper proposes improved EMTDC models for control fad protection analysis of grid-connected co-generation systems. Through on-site characteristic testing, the models were developed and the model parameters were determined. The models were applied to a field co-generation system, and analysis of control and protection was performed showing a good match to the simulation results.

Over-Excitation Protection Relaying using the 345kV Power System Modeling Data (345kV 계통 모델링 데이터를 활용한 과여자 보호계전기법)

  • Park, Chul-Won;Ban, Yu-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.4
    • /
    • pp.175-180
    • /
    • 2011
  • A large AC generator is an important component of the power system. It is a need for research of AC generator protection relay for the next-generation ECMS and an efficient operation of protection control system. However, most of protection and control systems used in power plants have been still imported as turn-key and operated in domestic. This may cause the lack of the correct understanding on the protection systems and methods, and thus have difficulties in optimal operation. In this paper, over-excitation protection relaying is one of the protective factors in generator protection IED was presented. The cause and protection principles were dealt and, DFT-based gain compensation algorithm was adopted for the frequency measurement. The Republic of Korea 345kV modeling data by EMTP-RV was used for performance evaluation.

Design of a Flight Envelope Protection System Using a Dynamic Trim Algorithm

  • Shin, Ho-Hyun;Lee, Sang-Hyun;Kim, You-Dan;Kim, Eung-Tae;Sung, Ki-Jung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.12 no.3
    • /
    • pp.241-251
    • /
    • 2011
  • Most large commercial aircrafts and high performance military aircrafts use fly-by-wire (FBW) or fly-by-light systems to improve their controllability, comfort, and safety. A flight envelope protection technique is used with flight control systems utilizing the FBW technique. Such flight envelope protection systems prevent these aircraft from exceeding the structural/aerodynamic limits and control their surface limits. This is accomplished by predicting the values of the future state variables and adaptively compensating the control action. In this study, the conventional dynamic trim algorithm of the flight envelope protection is modified to increase the method accuracy and to handle cases with multiple variables. Numerical simulation is also performed to verify the performance of the proposed method.

Design of Unequal Error Protection for MIMO-OFDM Systems with Hierarchical Signal Constellations

  • Noh, Yu-Jin;Lee, Heun-Chul;Lee, Won-Jun;Lee, In-Kyu
    • Journal of Communications and Networks
    • /
    • v.9 no.2
    • /
    • pp.167-176
    • /
    • 2007
  • In multimedia communication systems, efficient transmission system design should incorporate the use of matching unequal error protection (UEP), since source coders exhibit unequal bit error sensitivity. In this paper, we present UEP schemes which exploit differences in bit error protection levels in orthogonal frequency division multiplexing (OFDM) systems over frequency selective fading channels. We introduce an UEP scheme which improves the link performance with multiple transmit and receive antennas. Especially, we propose a new receiver structure based on two stage Maximum Likelihood detection (MLD) schemes which can approach the performance of a full search MLD receiver with much reduced computational complexity. In the performance analysis, we derive a generalized pairwise error probability expression for the proposed UEP schemes. Simulation results show that the proposed schemes achieve a significant performance gain over the conventional equal error protection (EEP) scheme.

A Study on the Injury Criteria of the Occupant Protection Performance of Crush Cushions (충격흡수시설의 탑승자보호 성능평가 기준에 관한 연구)

  • Lim, Jae-Moon;Jung, Geun-Seup
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.2
    • /
    • pp.49-57
    • /
    • 2008
  • The performance of crash cushion systems is certified through the full scale crash tests by the standard for installation and maintenance guidelines for roadside safety appurtenance. The impact severities of impacting vehicles in collision with crash cushion systems are rated by indices THIV and PHD. Crash test results are considered to study the performance of three crash cushion systems. In case of the frontal impact or the offset frontal impact, the results show that THIV values of three systems are very close to the threshold limit for the occupant protection. Also, the results show that PHD would be improper for the occupant protection performance index. In order to improve the occupant protection performance of crash cushions, ASI needs to be included in the impact severity index.

Development of Transmission Line Protection Relay Models for PSS/E (PSS/E용 송전선로 보호 계전기 모델 개발)

  • Kim, Jong-Wook;Kang, Sang-Hee;Lee, Dong-Gyu;Lee, Seong-Jin;Kwon, Seok-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.423-425
    • /
    • 2005
  • Te digital simulation of electric power system is a very important tool that can decide a proper protection systems from the design of the systems. Protection systems base on the wrong simulation results can cause a serious danger in the stability of the power system. So, the power system makes for simulation and the actual power system must be maximumly homologized. In this paper, protection relay models used in actual systems were developed in the PSS/E.

  • PDF

Study on a Network for the Protection and Control in Substations (변전소용 자동화 네트워크의 구현을 위한 연구)

  • Kwon, Wook-Hyun;Chung, Beom-Jin;Yun, Man-Cheol;Kim, Il-Dong
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.100-105
    • /
    • 1990
  • Associated with the protection and control functions in the substations, a new network scheme based on the IEEE 802.4 is proposed in this paper. This network is designed for supporting 3 data classes: 1st, it includes the highly time-critical data for the fault detection function. 2nd, routine data with a period is to served for monitoring the power status. Finally, it contains the control data which is used for reporting an event about protection or tuning some values related with power status. The way to allocate target_token_rotation timer is provided to guarantee the protection and control activities in the suggested network for the substation.

  • PDF

Measures and Proposal for Korean Solar Water Heating System (한국형 태양열 온수급탕 시스템의 대책과 제안)

  • Kim, Sung-Soo;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.9
    • /
    • pp.631-636
    • /
    • 2008
  • Solar thermal systems are recently refocused by higher oil prices, but did not completely restore the people's confidence owing to the past bad systems. Several types of solar water heating systems were analyzed in characteristics and some proper systems were proposed under Korean climates and system scale. As a small system, natural circulation system should be installed only in a southern region of Korea, with a freeze protection valve instead of heating coil for freeze protection. In most area of Korea, the forced circulation type with a heat exchange coil inside a thermal storage tank or with a spiral-jacketed storage tank, proposed and verified by the authors, has a merit of stable performance and freeze protection.