• Title/Summary/Keyword: Protection Systems

Search Result 2,294, Processing Time 0.031 seconds

A development of digital motor protection relay for power supervisory control system (전력감시 제어시스템을 위한 모터보호용 디지탈 보호계전기 개발)

  • 이성환;우천희;정현호;김정한;김상철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1496-1499
    • /
    • 1997
  • Recently the major requirements have emerged in industrial substation system field. One is the simple arrangement of main power supply equipment and the other is the introduction of highly computer-controlled system for operation, maintenance and protection. This paper deals with the systems including motor-type relay systems, supervisory and control systems, digital type relay protectiion systems.

  • PDF

Protectability: An Index to Indicate Protection Level of Primary Distribution Systems

  • Lee, Seung-Jae;Park, Myeon-Song;Kang, Sang-Hee;Kim, Sang-Tae
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.1
    • /
    • pp.7-16
    • /
    • 2003
  • A new method to evaluate the protection capability of distribution systems is reported in this paper. This work describes the fuzzy evaluation attributes and aggregation method of evaluation results based on a hierarchical model and the modified combination rule. An evaluation grade index called "protectability" is proposed and is expected to be a very uscful tool in defining an optimal protection and realizing the adaptive protection.rotection.

Performance Optimization of Tandem Source-Channel Coding Systems Employing Unequal Error Protection Under Complexity Constraints (복잡도 제한 하에서 비균등 오류 보호 기법을 사용하는 탠덤 소스-채널 코딩 시스템의 성능 최적화)

  • Lim, Jongtae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2537-2543
    • /
    • 2014
  • Between tandem source-channel coding systems and joint source-channel coding systems, it has been known that there is a complexity threshold in complexity versus performance. In this paper, by expanding the previous analysis for equal error protection systems, we analyze and compare the performance under complexity constrains for tandem source-channel coding systems which employ unequal error protection. Under a given complexity constraint, the optimization is performed to minimize the end-to-end distortion of each representative tandem and joint source-channel coding system. The results show that the complexity threshold for unequal error protection systems becomes smaller and the performance enhancement of unequal error protection systems over equal error protection systems gets smaller as the system complexity gets larger.

Fuzzy Petri-net Approach to Fault Diagnosis in Power Systems Using the Time Sequence Information of Protection System

  • Roh, Myong-Gyun;Hong, Sang-Eun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1727-1731
    • /
    • 2003
  • In this paper we proposed backward fuzzy Petri-net to diagnoses faults in power systems by using the time sequence information of protection system. As the complexity of power systems increases, especially in the case of multiple faults or incorrect operation of protective devices, fault diagnosis requires new and systematic methods to the reasoning process, which improves both its accuracy and its efficiency. The fuzzy Petri-net models of protection system are composed of the operating process of protective devices and the fault diagnosis process. Fault diagnosis model, which makes use of the nature of fuzzy Petri-net, is developed to overcome the drawbacks of methods that depend on operator knowledge. The proposed method can reduce processing time and increase accuracy when compared with the traditional methods. And also this method covers online processing of real-time data from SCADA (Supervisory Control and Data Acquisition)

  • PDF

Statistics on the Present Status of Installations of Non-conventional Lightning Rods (일반형이 아닌 피뢰침의 설치 실태에 대한 통계적 조사)

  • Lee, Bok-Hee;Lee, Seok-Yeon;Lee, Su-Bong;Baek, Young-Hwan;Lee, Kyu-Sun;Kim, Dong-Sung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.347-350
    • /
    • 2006
  • The conception of early streamers is in sufficient and inadequate as a parameter for the determination of any advantage of early streamer emission(ESE) lightning rods versus ordinary lightning rods. Thus, standards for many other national and international lightning protection as well as KS C IEC 61024-1 do not take ESE lightning rods, charge dissipation systems or non-conventional lightning rods. Unfortunately, many non-conventional lightning rods such as ESE lightning rods and charge dissipation systems in Korea are increasingly used in lightning protection of structures including explosive manufacturing buildings, electric generating, transmission and distribution systems. This study attempts to make aware of no advantage of ESE rods and other non-conventional lightning protection systems and to investigate the present status of installations of ESE lightning rods.

  • PDF

Concept Development of Core Protection Calculator with Trip Avoidance Function using Systems Engineering

  • Nascimento, Thiago;Jung, Jae Cheon
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.16 no.2
    • /
    • pp.47-58
    • /
    • 2020
  • Most of the reactor trips in Korean NPPs related to core protection systems were caused not because of proximity of boiling crisis and, consequently, a damage in the core, but due to particular miscalculations or component failures related to the core protection system. The most common core protection system applied in Korean NPPs is the Core Protection Calculator System (CPCS), which is installed in OPR1000 and APR1400 plants. It generates a trip signal to scram the reactor in case of low Departure from Nucleate Boiling Ratio (DNBR) or high Local Power Density (LPD). However, is a reactor trip necessary to protect the core? Or could a fast power reduction be enough to recover the DNBR/LPD without a scram? In order to analyze the online calculation of DNBR/LPD, and the use of fast power reduction as trip avoidance methodology, a concept of CPCS with fast power reduction function was developed in Matlab® Simulink using systems engineering approach. The system was validated with maximum of 0.2% deviation from the reference and the dynamic deviation was maximum of 12.65% for DNBR and 6.72% for LPD during a transient of 16,000 seconds.

Current Status and Prospect of Aircraft Ice Protection Systems (항공기 결빙 보호장치의 기술 현황 및 전망)

  • Lee, Jae-Won;Cho, Min-Young;Kim, Yong-Hwan;Yee, Kwanjung;Myong, Rho-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.11
    • /
    • pp.911-925
    • /
    • 2020
  • Aircraft ice protection systems are applied to the window shield, engine inlet, and wings to protect the aircraft from ice that may form on the surfaces of aircraft and sensors during operation. Icing on the aircraft can cause serious accidents by degrading the flight stability of the aircraft and by malfunctions in sensors such as the air data probe. Various types of ice protection systems have been developed for aircraft in the past. The electro-thermal type ice protection system contributes greatly to improving energy efficiency in a relatively simple structure, and has established itself as one of most popular ice protection systems for modern aircraft. In this review, two representative ice protection systems-hot-air and electro-thermal types-were intensively analyzed, and the prospect of ice protection systems was discussed based on the current status and application cases.

An Analysis Measure for Cybersecurity linked Threat against Diverse Protection Systems (다양성보호계통 사이버보안 연계 위협 분석 방안)

  • Jung, Sungmin;Kim, Taekyung
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.17 no.1
    • /
    • pp.35-44
    • /
    • 2021
  • With the development of information technology, the cybersecurity threat continues as digital-related technologies are applied to the instrumentation and control system of nuclear power plants. The malfunction of the instrumentation and control system can cause economic damage due to shutdown, and furthermore, it can lead to national disasters such as radioactive emissions, so countering cybersecurity threats is an important issue. In general, the study of cybersecurity in instrumentation and control systems is concentrated on safety systems, and diverse protection systems perform protection and reactor shutdown functions, leading to reactor shutdown or, in the worst case, non-stop situations. To accurately analyze cyber threats in the diverse protection system, its linked facilities should be analyzed together. Risk analysis should be conducted by analyzing the potential impact of inter-facility cyberattacks on related facilities and the impact of cybersecurity on each configuration module of the diverse protection system. In this paper, we analyze the linkage of the diverse protection system and discuss the cybersecurity linkage threat by analyzing the availability of equipment, the cyber threat impact of the linked equipment, and the configuration module's cybersecurity vulnerability.

Development of an Imaging Based Gang Protection System

  • Grimm, M.;Pelz, M.
    • International Journal of Railway
    • /
    • v.1 no.4
    • /
    • pp.149-156
    • /
    • 2008
  • During maintenance or construction works in or at the tracks of railways, high risks for passengers and railway staff, especially for the workers on the construction site exist. The high risks result out of the movement of rail vehicles, like trains or construction vehicles, which must be faced by using any available technical and operational technologies for securing them against the environment. Therefore, it is necessary to evaluate the level of protection continuously and to identify new and innovative methods and technologies for the protection of the gang (construction worker, machines and material). Especially on construction sites at line sections with two or more parallel tracks but also with single tracks, there are still a lot of incidents and accidents mostly with seriously injured persons or fatalities. These were mainly gang members that breach the railway-loading gage. By using proper warning or protection systems, the avoidance of such accidents must be achieved. The latest developments. in gang protection systems concern on the one hand fixed barriers in the middle between the construction site and the operated track and on the other hand construction vehicles equipped with automatic warning systems. The disadvantage of such protection methods is that the gang can be warned against an approaching train but a monitoring of the gang members cannot be performed. Only one part of a potential dangerous situation will be detected. If the gang members will overhear the acoustic warning signal of the security staff and the workers will not leave the danger zone in the track, the driver of the approaching train had no chance to react to the dangerous situation. An accident is often inevitable. While the detection of acoustic warning signals by the gang members working on a construction site is very difficult, the acoustical planning of an automatic warning system has to be designed for an acoustic short range level of one meter besides the construction vehicle. The decision about the use of today's technical warning system (fixed systems, automatic warning systems, etc.) must be geared to the technical feasibility and the level of safety which is needed. Criteria for decision guidance to block a track should be developed by danger estimation and economical variables. To realize the actual jurisdiction and to minimize the hazards of railway operations by the use of construction vehicles near the tracks further developments are needed. This means, that the warning systems have to be enhanced to systems for protection, which monitor the realization of the warning signal as a precondition for giving a movement authority to a train. This method can protect against accidents caused by predictable wrongdoing. The actual state of the art technique of using a collective warning combined with additional security staff is no longer acceptable. Therefore, the Institute of Transportation System of the German Aerospace Center in Braunschweig (Germany) will develop a gang warning and protection system based upon imaging methods, with optical sensors such as video in visible and invisible ranges, radar, laser, and other. The advantage of such a system based on the possibility to monitor both the gang itself and the railway-loading gauge either of the parallel track or of the same track still in use. By monitoring both situations, the system will be able to generate a warning message for the approaching train, that there are obstacles in the track, so that the train can be stopped to prevent an accident. And also the gang workers will be warned, while they breach their area.

  • PDF

Study on the Influence of Stray current Between Sacrificial Anode Cathodic Protection and Impressed Current Cathodic Protection in Marine Environment

  • Jeong, Jin-A;Kim, Ki-Joon
    • Corrosion Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.77-81
    • /
    • 2012
  • Cathodic protection(CP) is widely used as a means of protecting corrosion for not only marine structures like ship hulls and offshore drilling facilities, but also underground structures like buried pipelines and oil storage tanks. The principle of CP is that the anodic dissolution of metal can be protected by supplying electrons to the cathode metal. When unprotected structures are nearby to CP systems, interference problems between unprotected and protected structures may be happened. The stray current interference can accelerate the corrosion of nearby structures. So far many efforts have been made to reduce the interference in the electric railway systems adjacent to the underground metal structures like buried pipelines and gas/oil tanks. During recent few decades the protection technologies against stray current induced corrosion have been significantly improved and a number of techniques have been developed. However, there is very limited information an marine environments. Some complex harbor structures are protected by two cathodic protection systems, i.e. sacrificial anode cathodic protection(SACP) and impressed current cathodic protection(ICCP). In this case, when the protection current from sacrificial anodes returns to the cathode through electrolyte, it passes through nearby other low resistance metal structures. In many cases the stray current of ICCP systems influences the function of SACP. In this study, the risk of stray current from the SACP system to adjacent reinforced concrete structures has been verified through laboratory experiments. Concrete and steel pile structures modeled a part of bridge have been investigated in terms of CP potential and current between the two. The variation of stray current according to the magnitude of ICCP/SACP has been studied to mitigate it and to suggest the proper protection criteria.