• 제목/요약/키워드: Prosthetic complication

검색결과 101건 처리시간 0.023초

대동맥장루 -1예 보고- (Aortoenteric Fistula - A Report of a Case -)

  • 김성수
    • Journal of Chest Surgery
    • /
    • 제22권5호
    • /
    • pp.823-828
    • /
    • 1989
  • Aortoenteric fistula is an uncommon important complication of aortic reconstruction with a prosthetic graft. The complication often is difficult to diagnose and is associated with poor prognosis. Aortoenteric fistula could be divided into true aortoenteric fistula and paraprosthetic-enteric fistula. In case of true aortoenteric fistula, an actual communication between the gastrointestinal tract and the aortic lumen is present. So, massive gastrointestinal hemorrhage is the presenting manifestation. In paraprosthetic-enteric fistula, characterized by communication between the gastrointestinal tract and the external surface of synthetic vascular prosthesis without actual fistularization into the vascular lumen, the predominant clinical manifestation were sepsis, fever and anemia. We experienced one case of paraprosthetic-enteric fistula in a 16 years old male after abdominal aortic reconstruction with a prosthetic graft. The interval from the operation to onset of symptoms was 40 months. The initial clinical manifestation was sepsis, fever and anemia without massive gastrointestinal hemorrhage. Surgical treatment consists of complete excision of infected graft, two layers closure of jejunal wall defect and pledgets suture of aortic stump with surrounding health tissue. Anatomic revascularization was not able to be done: because of extensive retroperitoneal inflammation and extraanatomic revascularization did not performed due to adequate distal blood supply through rich collateral circulation. After operation, he complained numbness on left foot on moderate exertion and felt coldness on left leg compared with right leg but not showed skin color change. 43 days after operation, he discharged without gait disturbance except numbness on left foot on moderate exertion.

  • PDF

St. Jude Medical 판막에 의한 승모판치환술의 임상성적 (Clinical Results of Mitral Valve Replacement with St. Jude Medical Valve)

  • 장원채;신성현;나국주;김상형
    • Journal of Chest Surgery
    • /
    • 제31권3호
    • /
    • pp.247-254
    • /
    • 1998
  • 저자들은 1986년 8월부터 1996년 5월까지 172례의 환자에서 St. Jude Medical 판막을 사용하여 승모판 치환술을 시행하였다. 병원사망률(hospital mortaliy rate)은 3.5%(6례)였고, 만기사망률(late mortality rate)은 3.3%(5례)였다. 생존한 161명의 환자에서 추적관찰(follw-up)을 시행하였는데 평균기간은 50.23$\pm$0.27개월이었다. 인공판과 관련된 합병증으로는 좌방혈전 및 이로인한 뇌경색으로 사망한 예가 2례있었고, 인공판 심내막염(Prosthetic valve endocarditis)이 발생하여 사망한 예가 1례 있었으며, 항응고요법에 동반된 것으로 추정되는 출혈성 합병증은 2례에서 발생하였다. 전체환자의 10년 생존률은 92.3%이었다. 이상으로 본 흉부외과교실에서는 St. Jude 기계판을 사용하여 승모판 치환술의 중단기 임상성적을 문헌고찰과 함께 보고하는 바이며, 앞으로 계속해서 장기추적관찰에 노력할 생각이다.

  • PDF

The clinical prognosis of implants that are placed against super-erupted opposing dentition

  • Kim, Young-Kyun;Ahn, Kyo-Jin;Yun, Pil-Young;Yi, Yang-Jin;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제42권3호
    • /
    • pp.139-143
    • /
    • 2016
  • Objectives: If teeth are missing, super-eruption of teeth in the opposing arch can occur in the area and can change the occlusal plane. When missing teeth are replaced with implants, the oral surgeon must determine whether or not the super-erupted teeth need to be treated in order to normalize the occlusal plane. In this study, we evaluated the clinical prognosis of dentition after implant placement and prosthetic treatment were completed in an occlusal plane altered by super-erupted teeth in the opposing arch without additional treatment of the super-erupted teeth. Materials and Methods: Twenty-two patients (9 males, 13 females) were treated with implants and prosthetics without addressing the super-erupted opposing dentition from April 2004 to August 2012 at Seoul National University Bundang Hospital. A total of 33 implants were placed. Values of crestal bone loss, survival rates, and surgical and prosthetic complications for an average of 29.6 months after prosthetic loading were recorded. Results: In one case, the cover screw was exposed after implant surgery. The mean crestal bone loss was $0.09{\pm}0.30mm$. Of the 33 implants, 31 survived, a survival rate of 93.94%. A prosthetic complication occurred in one case but functioned well after correction. Conclusion: Favorable clinical results from prosthetic complications, crestal bone loss, and implant survival rates were exhibited in implants next to a super-erupted opposing tooth.

판막주위 누출에 대한 다크론 확장 인공판막을 이용한 판막치환술 치험 (Trido Mitral Valve Replacement with Dacron Collar Prosthetic Valve due to Paravalvular Leak)

  • 배윤숙;정성철;김우식;정승혁;이정호;김병열
    • Journal of Chest Surgery
    • /
    • 제35권11호
    • /
    • pp.822-825
    • /
    • 2002
  • 승모판막의 인공판막 재치환술 후 발생하는 판막주위 누출은 드물지만 심각한 합병증이다. 판막주위 누출은 생존률의 증가나 증상호전을 위하여 적극적인 수술적 치료가 필요하다. 그러나 누출부의 단순한 봉합이나 첨포를 이용한 폐쇄는 판륜의 주위조직이 약화된 경우나 결손이 광범위한 경우에는 효과적이지 않다. 이에 저자들은 다크론 판 (Dacron sheet)으로 봉합륜(sewing ring)을 확장한 인공 기계 판막을 이용하여 판륜에 판막을 고정함과 동시에 다크론 판을 좌심방벽에 봉합하여 판막의 고정과 더불어 혈액의 누출을 방지하는 삼차 승모판막 재치환술을 시행하였다. 3례 모두 수술 후 특별한 문제없이 추적 관찰 중이다.

대동맥류의 수술요법 (Surgical treatment of the aortic aneurysm)

  • 박표원;노준량
    • Journal of Chest Surgery
    • /
    • 제16권3호
    • /
    • pp.301-309
    • /
    • 1983
  • Twenty-three patients with aneurysm were operated between Jan. 1956 to July 1983 at the Department of Thoracic surgery, Seoul National University Hospital. There were 18 males and 5 females in this series. The age ranged from 14 to 68 years with the mean age of 41 years. The etiology of aortic aneurysms was atherosclerosis in 10, trauma in 2, annuloaortic ectasia in 4, syphilis in 1, and unknown etiology in six cases. Among the 4 patients with ascending aortic aneurysm, aortic valve replacement with aneurysmorrhaphy in three patients and Bentall operation in one patient were performed successfully. One patient with entire aortic arch aneurysm was received Dacron graft replacement with anastomosis of brachiocephalic arteries separately under cardiopulmonary bypass. There was no complication. Among 6 patients involving the descending thoracic aorta, three patients were managed by prosthetic bypass graft and aneurysm resection, and another three patients were also managed by prosthetic graft replacement. There were three hospital deaths. There were two thoracoabdominal aortic aneurysm. One patient in shock state due to preoperative rupture died from cardiac arrest during operative procedure. In another patient who had extensive involvement from the midportion of descending thoracic aorta to the terminal abdominal aorta, the aneurysm was successfully repaired with Dacron graft. In this instance celiac axis, superior and inferior mesenteric arteries and right renal artery were anastomosed separately. Eight of the 10 abdominal aortic aneurysms was replaced with prosthetic graft. One saccular aneurysm was treated by resection and primary closure. In another patient, cardiac arrest occurred during operation before definitive procedure. There was one another hospital death in the patient with preoperative rupture.

  • PDF

Biomechanical Complications : 파절과 나사풀림 (Biomechanical Complications : Fracture and Screw loosening)

  • 김태인
    • 대한치과의사협회지
    • /
    • 제53권5호
    • /
    • pp.307-317
    • /
    • 2015
  • Although the long-term success of osseointegrated endosseous implants for the support of fixed dental prostheses has been reported, the increasingly widespread use of implant-supported prostheses has led to problems associated with their structural integrity. The most common biomechanical complications observed in dental implant treatment are fracture and screw loosening. The nature of loosening or fracture of dental implant components is complex, since it involves fatigue, fitness, and varied chewing patterns and loads. To assess the service life of the components of the prosthetic system, a knowledge of the loads transmitted through the system is necessary. Design of the final restoration and occlusion in relation to the geometry of a prosthetic restoration has a great influence on the mechanical loading of the implant. It is proposed that control of force in oral cavity may play a larger role in failures than previously believed. Based on theoretic consideration and clinical experiences with dental implant, this article gives simple guidelines for controlling these loads.

협소한 대동맥판윤의 첨포확대후 대동맥 및 승모판막 대치술 치험 1예 (Mitral and Aortic Valce Replacement with Patch Enlargement of Narrow Aortic Annulus)

  • 강면식
    • Journal of Chest Surgery
    • /
    • 제12권1호
    • /
    • pp.56-60
    • /
    • 1979
  • Replacement of the aortic valve in a normal or large aortic root can be accomplished with ease and safety in most instances. The presence of a narrowed aortic annulus remains a problem in that the replaced smaller prosthetic valve has a significant resting pressure gradient across the orifice. This narrowing causes not only technical difficulties, but also increased mortality and post-op. complication. Therefore this problem deserves special attention. This report presents our experience with a case of a small aortic root caused by rheumatic heart disease [AI and MS]. This is the method of enlargement of the aortic annulus with a woven Dacron patch and replacement of a larger prosthetic aortic valve combined with mitral valve replacement.

  • PDF

Emergency Quadrido-Bentall Procedure for Aortic Rupture in a Patient with Behcet's Disease

  • Park, Sung Jun;Lee, Jeong-woo;Kim, Joon Bum
    • Journal of Chest Surgery
    • /
    • 제48권5호
    • /
    • pp.364-367
    • /
    • 2015
  • Cardiovascular involvement in cases of Behcet's disease is a rare but life-threatening condition, and prosthetic valve detachment is a frequent and serious complication attributable to Behcet's disease following the surgical repair of aortic regurgitation. We report the case of a patient with Behcet's disease presenting with contained aortic rupture around the aortic root. The patient had previously undergone aortic valve surgery three times due to recurrent prosthetic valve detachment. An emergency operation was performed, consisting of aortic root replacement (ARR) using a composite valved conduit and the replacement of the hemiarch. ARR may be an appropriate surgical option for patients with Behcet's disease in order to prevent recurrence of the disease.

15세 이하 소아에서의 판막치환술 (Pediatic Valve Replacement)

  • 박재홍
    • Journal of Chest Surgery
    • /
    • 제27권12호
    • /
    • pp.984-988
    • /
    • 1994
  • Between 1981 and 1992, 22 children from 1 to 15 years of age have undergone cardiac valve replacements at National medical center. The patients were composed of 14 males and 8 females and 7 patients had congenital heart disease and 15 patients had rheumatic heart disease. Three of these 15 patients have had second valve replacement due to prosthetic valve failure[PVF]. Single valve replacement were 20[Aortic 3 cases, Mitral 17 cases] and double valve replacments were 2. The overall mortality was 22.7 %. Actuarial survival rate was 77.28 $\pm$ 8.92 % and Complication free rate was 67.68$\pm$15.56%. The pediatric valve replacements can now be performed at a low operative risk although various problems are still remained and the choice of valve is prosthetic valve mainly due to its durability at the present time.

  • PDF

작은 인공판막주위 누출에 의한 용혈성 빈혈 (Hemolytic Anemia due to Tiny Prosthetic Paravalvular Leakage)

  • 문광덕;김대영
    • Journal of Chest Surgery
    • /
    • 제29권4호
    • /
    • pp.444-448
    • /
    • 1996
  • 작은 인공판막주위 누출에 의한 용혈성 빈혈은 인공판막 치환술후올수 있는 합병증중의 하나이다. 경도의 용혈은 대개 기계 판막으로 대동맥 판막 치환술을 시행했을 때 생기 지만, 드물게는 승모판막 치환 술 후에 생 기도 더욱 드물게 조직판막 치환술 후에도 생 긴다 조직판막 치환술후에 용혈성 빈혈은 거의 생기지 않는다. lonescu-Shiley 심낭판막 치환술을 받은 환자에서 용혈성 빈혈은 승모판막에서는 없었고, 대동맥판막 에서 주로 발생하였다고 보고되 어 왔다. 41세 여자환자가 갑자기 진한적색뇨가생겨 본원에 입원하였다. 이 환자는 10년전 승모판막 폐쇄부전증으로 승모판막 치환술(lonescu-Shiley판막 27mm)을 받았던 병 력 이 있다. 심초음파검사상 판막을 통한 경도의 승모판막 폐쇄부전과 함께 판막의 비후가 관찰되었으나 판막주 위를 통해 세어나오는 판막주위 누출의 소견은 관찰할 수 없었다. 말초혈액도말검사상정적혈구성 정색소성 빈혈을 보였다. 혈액 및 요 검사에서 심한 용혈소견이 보였다. 51. Jude Medical 양엽 판막(size 27mm)으로 승모판막 치환술을 시행하였다. 수술시 lonescu-Shiley 판막에 판엽의 석 회화와 뒤틀림 ( istortion)이 있었고, 술자위 치 에서 1시 방향에 직경 5mm의 작은 판막주위 누출이 발견되었으며 이것이 용혈성 빈혈의 원인으로 생각되었다. 승모판 막 재치환술후 용혈소견은 완전히 사라졌다. 저자들은 작은 인공판막주위 누출에 의한 심한 용혈성 빈혈이 발생한 1예를 경험하였기에 문헌고찰 과 함께 보고하는 바이다.

  • PDF