• Title/Summary/Keyword: Prosthetic Socket

Search Result 15, Processing Time 0.02 seconds

Relationships Between the Transfemoral Socket Interface Pressure and Myoelectric Signal of Residual Limb During Gait

  • Hong, J.H.;Lee, J.Y.;Chu, J.U.;Lee, J.Y.;Mun, M.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1070-1073
    • /
    • 2002
  • The biomechanical interaction between the stump and the prosthetic socket is critically important to achieve close-to-normal ambulation. Many investigators suggested that the pressure changes during gait of transfemoral amputees are closely related to the prosthetic alignment, the socket shape, the stump size, and the residual muscle activity. The effects of the prosthetic alignment, the socket shape, and the stump size on the interface pressure were investigated previously. However, there is no report how the residual muscle activities in the transfemoral stump affect the socket interface pressure characteristics during gait. Since designs of socket fur lower limb amputees need to consider the socket interface pressure characteristics, the interface pressure patterns by the residual muscle activities during gait should be investigated. In this study, myoelectric signals (MES) and socket interface pressure in residual limb of transfemoral amputees were measured during the stance and swing phases of gait. For the purpose, specially designed quadrilateral sockets that MES electrodes could be instrumented were fabricated. A total of two transfemoral amputees were participated in the experiments. The measured temporal MES amplitude and interface pressure in knee flexor (biceps femoris) and extensor (rectus femoris) had significant correlations (P < 0.05). Based on the test results, It was suggested that the residual muscle activity of transfemoral amputees stump is an important factor affecting socket pressure changes during walk.

  • PDF

A Study on the Development of In-Socket Pressure Change Measurement Sensor for Estimation Locomotion Intention of Intelligent Prosthetic leg User (지능형 대퇴의족 사용자의 보행 의도 추정을 위한 소켓 내 압력 변화 측정 센서 개발에 관한 연구)

  • Park, Na-Yeon;Eom, Su-Hong;Lee, Eung-Hyuk
    • Journal of IKEEE
    • /
    • v.26 no.2
    • /
    • pp.249-256
    • /
    • 2022
  • The prosthetic leg is a device that performs walking instead of a amputated lower limb, and require a change in locomotion mode by providing the user's intention to respond to a discontinuous locomotion environment. Research has been conducted to detect the users' intentions through biomechanical features inside the socket that directly contacts the cut site in demand for natural locomotion mode changes without external control equipment. However, there is still a need for a sensor system that is suitable for the internal environment of the main body and socket of the cut site. Accordingly, this paper proposed a film-type sensor system that is suitable for the main body characteristics of the cut site, is not affected by the temperature and humidity conditions inside the socket, and is easy to manufacture in various sizes. The proposed sensor is manufactured base on Velostat film and takes into account the pressure measurement characteristics that vary with size. Through the experiment, the change in the internal pressure of the socket due to the intentional posture performance of the wearer was measured, and the possibility of detecting the intention to change the locomotion mode was confirmed.

Development of Multi-DoFs Prosthetic Forearm based on EMG Pattern Recognition and Classification (근전도 패턴 인식 및 분류 기반 다자유도 전완 의수 개발)

  • Lee, Seulah;Choi, Yuna;Yang, Sedong;Hong, Geun Young;Choi, Youngjin
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.3
    • /
    • pp.228-235
    • /
    • 2019
  • This paper presents a multiple DoFs (degrees-of-freedom) prosthetic forearm and sEMG (surface electromyogram) pattern recognition and motion intent classification of forearm amputee. The developed prosthetic forearm has 9 DoFs hand and single-DoF wrist, and the socket is designed considering wearability. In addition, the pattern recognition based on sEMG is proposed for prosthetic control. Several experiments were conducted to substantiate the performance of the prosthetic forearm. First, the developed prosthetic forearm could perform various motions required for activity of daily living of forearm amputee. It was able to control according to shape and size of the object. Additionally, the amputee was able to perform 'tying up shoe' using the prosthetic forearm. Secondly, pattern recognition and classification experiments using the sEMG signals were performed to find out whether it could classify the motions according to the user's intents. For this purpose, sEMG signals were applied to the multilayer perceptron (MLP) for training and testing. As a result, overall classification accuracy arrived at 99.6% for all participants, and all the postures showed more than 97% accuracy.

Development of Dry-type Active Surface EMG Electrode for Myoelectric Prosthetic Hand (근전의수용 건식형 능동 표면 근전도 전극의 개발)

  • 최기원;문인혁;추준욱;김경훈;문무성
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2733-2736
    • /
    • 2003
  • This paper proposes a dry-type active surface EMG electrode for the myoelectric prosthetic hand. The designed electrode is small size for embedding in the socket of prosthetic hand, and it has three leads including the reference of signal. To acquire EMG signal rejected the power noise, a precision differential amplifier and various filters such as the band pass filter band rejection filter, low pass and high pass filter are embedded on the electrode. The final output of the electrode is integrated absolute EMG (IEMG) obtained by full rectifier and moving average circuits. From experimental results using the implemented dry-type active surface EMG electrode, the proposed electrode is feasible for the myoelectric prosthetic hand.

  • PDF

Development of 6-Axis Stiffness Measurement Device for Prosthetic Socket Design (의수 소켓 설계를 위한 6축 인체 탄성도 측정 장치 개발)

  • Oh, Donghoon;Lee, Seulah;Choi, Youngjin
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.1
    • /
    • pp.58-64
    • /
    • 2019
  • The paper proposes a stiffness measurement device composed of a measurement part including six indenters and a fixing part including four fixtures. The device is able to make simultaneously measurements of the stiffness of human arm. The six indenters make use of both position and force control schemes sequentially whenever needed. In addition, the loadcells and the digital encoders are attached to the indenters and electric motors, respectively, so that the data can be provided in real time. On the end of the indenter, two-axis potentiometer is attached in order to measure the angle difference between the applied force axis and the axis normal to the skin of human arm, and to convert the force measured on the loadcell into the actual applied force to skin. For this purpose, the mapping between the voltage output and the angle of potentiometer was obtained by fitting it for each axis. Ultimately, the measurement device was able to measure the stiffnesses of six regions of human arm.

Visually Indistinguishable Intractable Neuroma Management after Below Knee Amputation: A Case Report (하퇴부 절단술 후 육안적으로 발견하기 어려운 난치성 신경종 처치: 증례 보고)

  • Shin, Seong Kee;Kim, Ki Chun;Roh, Youngju;Kim, Jongkyu
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.4
    • /
    • pp.212-215
    • /
    • 2019
  • Symptomatic neuromas after amputation can be troublesome to treat and make it difficult to properly fit a brace. Surgical management is required when conservative management such as prosthetic socket modification or local injections fail. However, small cutaneous nerves adhere to adjacent soft tissue and they are difficult to locate. The authors suggest that ultrasonography guided tattoo localization using a charcoal suspension is useful to find a visually indistinguishable neuroma.

Alveolar ridge preservation with a collagen material: a randomized controlled trial

  • Schnutenhaus, Sigmar;Doering, Isabel;Dreyhaupt, Jens;Rudolph, Heike;Luthardt, Ralph G.
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.4
    • /
    • pp.236-250
    • /
    • 2018
  • Purpose: Resorption of the alveolar bone is an unavoidable consequence of tooth extraction when appropriate alveolar ridge preservation (ARP) measures are not taken. The objective of this trial was to test the hypothesis that dimensional changes in the alveolar bone after tooth extraction would be reduced by inserting an equine collagen membrane and a collagen cone to fill and seal the alveolus (as ARP), in comparison to extraction with untreated alveoli. Methods: In this randomized clinical trial, 31 patients were directly treated with the collagen material after extraction of a tooth from the maxilla (the ARP group). Twenty-nine patients served as the control group. After extraction, no further treatment (i.e., no socket preservation measures) was performed in the control group. Changes in the alveolar process immediately after extraction and after an 8 (${\pm}1$)-week healing period were evaluated 3-dimensionally. Blinded analyses were performed after superimposing the data from the digitalized impressions and surfaces generated by cone-beam computed tomography. Results: Both the ARP and control groups showed a reduction of bone in the alveolar area after tooth extraction. However, significantly less bone resorption was detected in the clinically relevant buccal region in the ARP group. The median bone reduction was 1.18 mm in the ARP group and 5.06 mm in the control group (P=0.03). Conclusions: The proposed hypothesis that inserting a combination material comprising a collagen cone and membrane would lead to a difference in alveolar bone preservation can be accepted for the clinically relevant buccal distance. In this area, implantation of the collagen material led to significantly less alveolar bone resorption. German Clinical Trials Register at www.drks.de, DRKS00004769.

Functional Improvement Following Revision Surgery in a Patient with the Dual Disability of a Complicated Residual Limb and Contralateral Hemiplegia: A Case Report

  • Byun, Ki Hyun;Yang, Dong Seok;Jang, Baek Hee
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.5
    • /
    • pp.199-203
    • /
    • 2018
  • The number of reported cases with dual disability is increasing for the past few decades. Currently, dual disability of lower limb amputation and motor weakness after stroke became a strong issue in public concern. The functional levels of patients have shown in the wide range from independent community ambulation to non-ambulation. Thus, it indicates that favorable outcomes for dual disability may depend upon adopted rehabilitative strategies. We present the case of a man with left below-knee amputation and severe right-sided weakness following a huge putaminal hemorrhage. He had suffered from extreme pain and misfit of the prosthetic socket and the complicated residual limb for three years prior to the stroke. Forty days post-stroke, we performed a revision surgery to resolve the complications of bony overgrowth, verrucous hyperplasia, and neuroma and applied an ankle foot orthosis (AFO). Two years post-stroke, he was able to ambulate outside his home and negotiate stairs using a cane. This is the first case with the dual disability of lower limb amputation and contralateral hemiplegia to undergo revision surgery. The results suggest that an early revision surgery and use of an AFO are crucial for achieving a higher level of mobility in such cases.

Immediate implantation for single mandibular first molar restoration: clinical case report (하악 제1대구치 단일 수복을 위한 발치 즉시 임플란트의 임상증례)

  • Park, Cheol-Woo
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.4-12
    • /
    • 2021
  • Immediate implantation is widely applied as it is recognized as a useful implant treatment in dental clinic due to its various advantages as well as being able to shorten the treatment period. Immediate implant treatment was performed on 5 patients who needed extraction of the mandibular first molar for various reasons, shortening the overall treatment period, and obtaining satisfactory results. Immediate implantation after extraction is a high-level treatment that requires proper initial fixation at the exact location of the extraction socket and the surrounding soft tissues, but is considered to be a clinically very useful prosthetic restoration method