• Title/Summary/Keyword: Proportional electromagnet

Search Result 6, Processing Time 0.026 seconds

A Study on the Taper Plunger Type Proportional Electromagnet for ISC Valve (ISC 밸브용 테이퍼 플런저형 비례전자석에 관한 연구)

  • Song, Chang-Seop;Lee, Tae-Hyeong;Yun, Jang-Sang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.3
    • /
    • pp.125-132
    • /
    • 1993
  • On this study, magnetic force versus input currents is analyzed by modeling taper plunger type proportional electromagnet of ISC valve using the permernce method. And, the reliabiliy of simulation is verified by comparing the experimental values with the calaulate magnetic force. From the result of this study, it is found that the taper angles at plunger and core, the length of air gap between plunger and yoke are the prumary factors in designing taper plunget type proportional electromagnet. Magnetic force is decreased as a whole according to increasing the air gap between pluger and yoke, and vise versa. But, the magnetic force is not proportional to current, when the air gap is very small. In case of decreasing the taper angle of pluger, the stroke range of plunger where magnetic force is proportional to current becomes farther from core.

  • PDF

A study of electromagnetic proportional flow control valve (비례전자식 유량제어벨브의 해석에 관한 연구)

  • Song, Chang-Seop;Yoon, Jang-Sang;Suh, Jong-Beom
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.1
    • /
    • pp.100-107
    • /
    • 1993
  • In this study, it is analyzed that an electromagnet whose generating force is proportional to constant current through coil in its coperating range. To find arelation between magnetic force and the structure in electromagnet, computer simulation method is used by permeance modeling method. When the electromagnet is applied to flow control valve, the relation between input current and flow is found. In order to get a reliability of computer simluation, the simulation results are compared to the experimental result. As the simulation is processed repeatedlyl. it is found that the gap size between plunger and guide steel and the length of tapered brass ring are important factors in electromaget.

  • PDF

Performance Study of Magnetic Bearing Considering the Performance Limit (자기 베어링의 성능한계를 고려한 작동특성 연구)

  • 장인배;한동철
    • Journal of KSNVE
    • /
    • v.5 no.1
    • /
    • pp.59-65
    • /
    • 1995
  • In this study, we investigated the operational limit of magnetic bearing-rotor system due to the maximum force limit and slew rjate limit of the electromagnetic actuator as a function of the time dependent control characteristics. The feedback gain of the controller varies the current of the electromagnet coil with the motion of the rotor. The distorsion of magnetic force due to the slew rate limit is not occurred jup to 30, 000 rpm in the magnetic bearing that we have a close relation with the rotational speed and vibration level of the rotor and the proportional gain of the controller. Therefore the maximum force limit determines the maximum allowable orbit radius of the magnetic bearing-rotor system. The maximum allowable vibration levels are exponentially decreased according to the increment of rotational speed and proportional gain of the controller.

  • PDF

Response Surface Tuning Methods in PID Control of the Magnetic Levitation Conveyor System (반응 표면법을 이용한 자기부상 반송장치의 PID 이득값 조정)

  • Bae, Kyu-Young;Kim, Chang-Hyun;Kim, Bong-Seup
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2609-2614
    • /
    • 2011
  • A proportional integral derivative (PID) controller is designed and applied to a magnetic levitation conveyor system to control the levitation gap length of the electromagnet constantly. The PID gain parameters are optimized by response surface methods (RSM). The controller is verified with the state-space model of electromagnetic suspension by MATLAB/SIMULINK program. And, the controller and the state-space model are also verified experimentally. Simulation and experimental results shows the effectiveness of the PID gain tuning by RSM as compared with the classical PID tuning.

  • PDF

CONTROL PERFORMANCE IMPROVEMENT OF AN EMV SYSTEM USING A PM/EM HYBRID ACTUATOR

  • Ahn, H.J.;Chang, J.U.;Han, D.C.
    • International Journal of Automotive Technology
    • /
    • v.8 no.4
    • /
    • pp.429-436
    • /
    • 2007
  • In this study, we improved control performance of an EMV (electromechanical valve) system using a PM/EM (permanent magnet/electromagnet) hybrid EMA (electromagnetic actuator) and showed the feasibilities of both soft landing and fast transition of the EMV system using a simple PID control. The conventional EMV systems using only EM show significant nonlinear characteristics. Therefore, it is very difficult to control the valve position and several complex control schemes are used. This paper focused on the control performance improvement using a PM/EM hybrid actuator. In particular, a PM is used as a key design parameter such as a bias current of a magnetic bearing in order to improve the linear characteristic of the actuator, although most PM/EM hybrid actuators use a PM as a power saver during valve-open and -closed states. First, a FE (finite element) analysis was performed to confirm its linear static force characteristics. Then, both a test rig and a valve control system were built in order to prove experimentally the control performance improvement of the actuator. Finally, feasibilities of both soft landing and fast transition of the system were shown experimentally through gain-scheduled PID (proportional derivative integral) control.

A Study on the Application of PbI2 Dosimetry for QA in the Electron Beam Therapy (전자선 치료의 선량 측정 QA를 위한 PbI2 선량계 적용 연구)

  • Yang, Seungwoo;Han, Moojae;Jung, Jaehoon;Choi, Yunseon;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.517-522
    • /
    • 2020
  • Electron beam have many factors that affect dose distribution, so even if identical settings are used, they should be identified and used for radiation treatment, and the effects on the structures in the body are sensitive, making it difficult to investigate uniform dose distribution on tumors. In this study, a dosimeter was produced using PbI2 which is a photoelectric material, and electrical characteristics were analyzed for 6, 9, and 12 MeV electronics in linear accelerators. The reproducibility test results showed that RSD were 1.1215%, 1.0160%, and 0.05137% respectively at 6, 9, and 12 MeV energies, indicating that the output signals were stable. The linearity evaluation results showed that the R2 values of the reliability indicator for straight line trend lines were 0.9999, 0.9999, and 0.9994, respectively, at 6, 9, and 12 MeV, to confirm that the output signal was proportional to PbI2 as dose increased. The PbI2 dosimeter in this study is judged to be highly applicable to electromagnet measurement and is thought to be able to be used as a basic study of electron detector through photoelectric material.