• Title/Summary/Keyword: Proper posterior

Search Result 176, Processing Time 0.025 seconds

Rehabilitation of posterior support and vertical dimension in a class 3 malocclusion patient: A case report (III급 부정교합 환자에서 상악 가철성 국소 의치와 하악 임플란트 지지 고정성 보철물을 이용한 구강 회복 증례)

  • Oh, Ji-Hwan;Pyo, Se-Wook;Chang, Jae-Seung;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.175-186
    • /
    • 2022
  • A crossed occlusion resulting from the presence of posterior teeth in one arch but no opposing teeth in the opposite arch results in collapse of the vertical dimension. In this case, the patient has a class III malocclusion with crossed occlusion and anterior crossbite. In order to evaluate the proper vertical dimension, provisional denture was used to stabilize the vertical occlusal dimension for 3 months. After, provisional fixed restoration was used for the stabilizing occlusal relationship and aesthetic improvement for lip support. Definitive prosthesis in implants in the mandible and abutments in the maxillary were using Porcelain-fused-to-metal crown (PFM) crown and the maxillary unilateral edentulous area was treated with removable partial dentures. Through this, proper support of the posterior region and normal anterior occlusal relationship were formed, and the patient was able to obtain aesthetically and functionally satisfactory treatment results.

Treatment of Ruptured Posterior Cruciate Ligament using Augmentation of the Synthetic Polyester Prosthetic Ligament (Synthetic Polyester Prosthetic Ligament 보강술을 이용한 후방 십자 인대 손상의 치료)

  • Sohn, Sung-Won;Jeon, Si-Hyun;Park, Jin-Uck
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.121-125
    • /
    • 2002
  • Purpose : The purpose of this study was to assess the clinical outcomes and radiological changes of arthroscopic augmentation with synthetic polyester ligament for posterior cruciate ligament injury Materials and Methods : The assessment was made among 60 patients who underwent arthroscopic augmentation with synthetic polyester ligament (ABC ligament, Surgicraft, U.K.) into the substance of ruptured PCL proper under the arthroscopic control from January, 1990 to January, 1996 and whose follow-up period was more than 5 years (average 7.8 years). The results were analyzed by using the posterior stress radiographs by Telos stress device, KT-2000 arthrometer and the clinical assessment by using Lysholm knee score. Results : The average difference of posterior displacement on stress radiographs were 13.2 mm preperatively and 3.6 mm at last follow up. Both knee showed minimal difference on KT-2000 arthrometer (0.7 mm on 20 lb) at the last follow-up. The mean Lysholm knee score was 49.2 preoperatively and improved to 84.3 post-operatively. Conclusion : Authors observed that long-term results of arthroscopic augmentation with synthetic polyester ligament for PCL injury were similar with those using human allograft. Taking these results into consideration, the synthetic polyester ligament is assumed to be a method of treatment of the PCL injury.

  • PDF

Full mouth rehabilitation on the patient with deep bite and posterior bite collapse using re-establishment of occlusal vertical dimension (구치부 교합 지지 상실과 전치부 과개 교합을 가진 환자의 교합 재설정을 통한 구강 회복 증례)

  • Jang, Woo-Hyung;Jo, Yu-Jin;Lim, Hyun-Pil;Yun, Kwi-Dug;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.50-57
    • /
    • 2020
  • The loss of posterior support and the abnormal jaw relation can cause pathologic findings. If deep bite patients with multiple missing teeth, can not have the stable posterior contact, the mandible moves posteriorly, and consequently the overjet and overbite get worse. And when the mandibular irregular occlusal plane is corrected, it is easier to have the bilateral balanced occlusion with the maxilla. So the treatment goal is to give proper posetrior support and establish appropriate anterior guidance, and ultimately provide improved mastication and esthetics recovery. In this case, a 68 year old man, having deep bite without posterior support was evaluated by the vertical dimesion decision flow-chart. An available prosthetic height, anterior occlusal relation such as overjet, overbite and the esthetic part such as facial height and the cephalometric analysis are the factors to be considered.

FRACTURE STRENGTH BETWEEN DIFFERENT CONNECTOR DESIGNS OF ZIRCONIA CORE FOR POSTERIOR FIXED PARTIAL DENTURES MANUFACTURED WITH CAD/CAM SYSTEM (CAD/CAM을 이용한 구치부 전부도재 고정성 국소의치 지르코니아 코어의 연결부 설계에 따른 파절강도)

  • Seo Jun-Yong;Park In-Nim;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.29-39
    • /
    • 2006
  • Statements of problem: Zirconia core is used for posterior fixed partial dentures because it's good mechanical properties. Stress is concentrated on connectors in fixed partial dentures, so the proper design of connector areas is needed for adequate mechanical long-term properties of any prosthesis. The area of connector is critical, but tooth size and surrounding soft tissue limit the connector design. Purpose: The purpose of this study is to compare fracture strengths between different connector designs of zirconia core for posterior fixed partial dentures manufactured with CAD/CAM system and determining the optimal connector design satisfying strength and hygiene. Material and method: The following four groups of 40 posterior fixed partial denture specimens(each group 10) were fabricated as followed; group 1 vertical height of connector is 3mm (control group, all groups have the same condition); group 2, lingual vertical 1mm reinforcement on connector; group 3, lingual vertical 2mm reinforcing on connector and group 4, lingual vertical 3mm reinforcing on connector. Specimens were subjected to compressive loading on the central fossa of pontic by instron. SEM was used to identify the initial crack and characterize the fracture mode. Results: The results were as follows: 1. The mean fracture load of the non-lingual reinforcing group was 1212N and the lingual vertical 1mm reinforcing group was 1510N, the lingual vertical 2mm reinforcing group was 1882N, the lingual vertical 3mm reinforcing group was 1980N. 2. The reinforcing groups were statistically significant compared to non-reinforcing groups(P<0.001). 3. There were 2, 3mm reinforcing groups that were statistically significant compared to 1mm reinforcing groups(P<0.001), and the 3mm reinforcing group was not statistically significant compared to 2mm reinforcing groups(P>0.05) 4. Fractures were initiated in gingival embrasures of connectors and processed to the loading site. Conclusion: In this study, lingual reinforcement of connector for improved strength of zirconia based fixed partial denture is nessasary. And long-term study for clinical application is required

Film Image Transfer System (FITS): An Efficient Method for Proper Positioning of Orthodontic Mini-implants

  • Go, Taek-Su;Kim, Seong-Hun;Nelson, Gerald
    • Journal of Korean Dental Science
    • /
    • v.4 no.1
    • /
    • pp.20-25
    • /
    • 2011
  • Purpose: To describe the newly developed Film image transfer system (FITS) for proper positioning of the orthodontic mini-implant in the narrow interdental space and considerations for better application. Materials and Methods: A patient who was planning to have orthodontic mini-implant treatment on the posterior maxilla was recruited to assess the feasibility of FITS. Dental radiographic film and bite record was taken. And then the film image was transferred on the photographic emulsion coated model using transfer light through film projector (enlarger). After exposing the photo emulsion coating on the model, the image was developed with a working solution for a paper developer and fixed. The surgical guide for the mini-implant was fabricated from the transported FITS data. Results: The completed surgical guide was easily placed intraorally, and allowed a simple and rapid placement of the mini-implant. The site of the implant placement was accurate as planned position. Conclusion: In the reported case, The FITS technique represents an effort to minimize risk to the patient and produce consistently good results based upon accurate information about the anatomy of the implant site.

Full mouth implant rehabilitation of a patient with ectodermal dysplasia after orthognathic surgery, sinus and ridge augmentation: a clinical report

  • Bayat, Mohammad;Khobyari, Mohammad Mohsen;Dalband, Mohsen;Momen-Heravi, Fatemeh
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.2
    • /
    • pp.96-100
    • /
    • 2011
  • An 18-year-old male presented severe hypodontia due to hypohidrotic ectodermal dysplasia was treated with Le Fort I maxillary osteotomy with simultaneous sinus floor augmentation using the mixture of cortical autogenous bone graft harvested from iliac crest and organic Bio-Oss to position the maxilla in a right occlusal plane with respect to the mandible, and to construct adequate bone volume at posterior maxilla allowing proper implant placement. Due to the poor bone quality at other sites, ridge augmentation with onlay graft was done to construct adequate bone volume allowing proper implant placement, using tissue harvested from the iliac bone. Seven implants were placed in the maxilla and 7 implants were inserted in the mandible and screw-retained metal ceramic FPDs were fabricated. The two year follow up data showed that dental implants should be considered as a good treatment modality for patients with ectodermal dysplasia.

AN ANALYSIS AND MANAGEMENT OF FRACTURED IMPLANTS (파절된 임프란트 고정체의 분석과 처치)

  • Han Chang-Hyun;Kim Sung-Hyun;Hee Seong-Joo;Ku Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.25-36
    • /
    • 2001
  • Among the numerous factors contributing to implant failure, the most common are infection, failure of proper healing and overload. These factors may occur combined. Implant fractures are one of the complications resulting from overload. Implant fracture is not a common feature, but once it occurs it causes very unpleasant circumstances for the patient as well as for the practitioner. Only few studies have been reported regarding this subject. Thus, little is known about its solutions. It is important that analyzing reasons for implant fracture and finding appropriate solutions. Factors leading to implant fracture are design, material defects, nonpassive fit of prosthetic framework and biomechanical overload. Previous studies have reported that implant fractures ares associated with marginal bone loss and occur mostly in the posterior regions and that most patients showing parafunctional habits also have implant fracture. Abutment and gold screw loosening or fracture were also observed in some of the cases previous to implant fracture. Similar observations were seen in our hospital as well. The following cases will present implant fracture cases which have been successfully treated regarding function and biomechanics. This was achieved by means of using increased number of futures, increasing fixture diameter and establishing proper occlusion.

  • PDF

A Case of the Soft Palate Reconstruction Using the Bilateral Palatal Mucomuscular Flap and Pharyngeal Flap after Wide Resection (연구개 및 구개수 암종의 광범위 절제 및 국소 점막근 피판 재건술 1예)

  • Gu, Ga Young;Lee, Hye Ran;Jang, Jeon Yeob
    • Korean Journal of Head & Neck Oncology
    • /
    • v.38 no.1
    • /
    • pp.31-35
    • /
    • 2022
  • The soft palate of carcinoma limited to the uvular region is infrequent among oropharyngeal cancers. The oropharynx regulates swallowing and speech through dynamic motions. Failure to reconstruct after surgical resection of the oropharynx structure can lead to permanent velopharyngeal insufficiency. Therefore, suitable reconstruction is important in establishing proper functional outcomes while maintaining oncological safety. We present a case of a 66-year-old male who was diagnosed with oropharynx cancer limited in the uvula accompanied by lymph node metastasis. After surgical resection, reconstruction was performed with the united arrangement of bilateral palatal mucomuscular flap and superiorly based posterior pharyngeal flap. There was no aspiration or reflux after feeding and epithelialization completely occurred after 1 month postoperatively. We report a successful case that the reconstruction with the local flap described above could preserve proper oropharyngeal function after primary surgery in small-sized oropharyngeal cancer.

Finite Element Modeling and Nonlinear Analysis of Lumbosacrum Including Partial Ilium and Iliolumbar Ligaments (부분 장골과 장요추 인대를 포함한 요추 천추골의 유한 요소 모델링 및 비선형 해석)

  • Ha, S.K.;Lim, J.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.397-409
    • /
    • 2007
  • Owing to needs of biomechanical comprehension and analysis to obtain various medical treatment designs which are related with the spine in order to cure and diagnose LBP patients, the FE modeling and nonlinear analysis of lumbosacrum including a partial ilium and iliolumbar ligaments, were carried out. First, we investigated whether the geometrical configuration of vertebrae displayed by DICOM slice files is regular and normal condition. After constructing spinal vertebrae including a partial ilium, a sacrum and five lumbars (from L1 to L5)with anatomical shape reconstructed using softwares such as image modeler and CAD modeler, we added iliolumbar ligaments, lumbar ligaments, discs and facet joints, etc.. And also, we assigned material property and discretized the model using proper finite element types, thus it was completely modeled through the above procedure. For the verification of each segment, average sagittal ROM, average coronal ROM and average transversal ROM under various loading conditions(${\pm}10Nm$), average vertical displacement under compression(400N), ALL(Anterior Longitudinal Ligament) and PLL(Posterior Longitudinal Ligament) force at L12 level, strains of seven ligaments on sagittal plane at L45 level and maximal strain of disc fibers according to various loading conditions at L45 level, etc., they were compared with experimental results. For the verification of multilevel-lumbosacrum spine including partial ilium and iliolumbar ligaments, the cases with and without iliolumbar ligaments were compared with ROM of experiment. The results were obtained from analysis of the verified FE model as follows: I) Iliolumbar ligaments played a stabilizing role as mainly posterior iliolumbar ligaments under flexion and as both posterior and anterior iliolumbar ligaments of one side under lateral bending. 2) The iliolumbar ligaments decreased total ROM of 1-8% in total model according to various motion conditions, which changed facet contact forces of L5S level by approximately 0.8-1.4 times and disc forces of L5S level by approximately 0.8-1.5 times more than casewithout ilioligaments, under various loading conditions. 3) The force of lower discs such as L45 and L5S was bigger than upper discs under flexion, left and right bending and left and right twisting, except extension. 4) It was predicted that strains of posterior ligaments among iliolumbar ligaments would produce the maximum 16% under flexion and the maximum 10% under twisting. 5) It's expected that this present model applies to the development and design of artificial disc, since it was comparatively in agreement with the experimental datum.

Restoration of patient accelerating anterior teeth wear by loss of posterior support: Case report (구치부 지지 소실에 의한 전치부 마모 가속화 환자의 수복: 증례보고)

  • Choi, Hyejin;Lee, Jaehoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.382-388
    • /
    • 2019
  • Increased anterior teeth mastication following posterior teeth loss leads to greater anterior occlusal force. It may cause greater attrition of anterior teeth, traumatic force occlusion (TFO), also often followed by antagonist extrusion and occlusal disharmony. This clinical report describes the treatment for a 67-year-old female patient diagnosed with loss of both maxillary and left mandibular posterior teeth, severe attrition of maxillary and mandibular anterior teeth and extrusion of multiple teeth. A diagnostic cast was mounted on articular in centric relation (CR) position to evaluate vertical dimension (VD) and interspace. To provide adequate space for the prosthetic reconstructions, VD was increased by 3 mm on the anterior pin. And then diagnostic wax-up was completed upon that VD. Wax-up was converted to provisional restorations and verified in the patient's mouth and the final restorations were delivered. Clinical follow up examination held 3 months after temporary restoration owing to changes in vertical dimension revealed proper function in mastication without evidence of temporo-mandibular joint (TMJ) disorders. This clinical report presents successfully restoring severe attrition case with increasing vertical dimension resulting in satisfaction in esthetics and function.