• Title/Summary/Keyword: Proper Supply Method

Search Result 132, Processing Time 0.032 seconds

A Study on the Voltage Drop and Earth Leakage Current according to Interval of AT in the AT Feeding Method (AT급전방식에서 AT간격에 따른 전압강하 및 대지누설전류에 대한 연구)

  • Kim, Min-Seok;Choe, Seung-Hyuk;Lee, Jong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1708-1714
    • /
    • 2011
  • AT feeding system of the electric railway system is installed every about 10km at between the feeder and catenary in parallel and the mid-point of the transformer is connected to the rail The supply voltage of this system is doubled than rolling stock voltage. So the voltage drop is smaller than usual. And the other merit of this system is the decreasing inductive disturbance to the communication line because of the reduced current in rail which runs reversed in a point of view of rolling stock. Also, ATP(Auto Transformer Post) is installed to reduce the voltage drop and to mitigate the inductive disturbance, but still now the proper distance between the ATP and AT feeding system is not established which ranges from 2 to 10[km]. The stable result of simulation(which is set that the end of the line AT is installed) to the voltage drop and inductive disturbance can not analyzes the effect to the supply system due to the ATP. This paper analyzes the effect to the system depending on the location of ATP by forecasting the voltage drop and inductive disturbance.

A Study on the Design Method of Cold & Hot Water Manifold System for Residential Buildings through the Piping Network Analysis (관망해석을 통한 주거용 건축물의 급수.급탕 헤더시스템 설계 방안에 관한 연구)

  • Cha, Min-Chul;Seok, Ho-Tae;Kim, Dong-Woo
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.111-120
    • /
    • 2008
  • The aim of this study is to present the design methods about manifold location being installed and size and to draw out the proper piping size as comparing the fluctuation of discharge with manifold size and residence size through the piping network analysis, when using the same faucet in accordance. The findings are summarized as follows, 1) an appropriate header main body pipe diameter was deemed to be $32{\sim}50\;mm$. 2) the research presented design measures for the application of appropriate water supply inlet pipe diameters according to residential buildings with various sizes. 3) the header direct branch piping method is ideal for small and medium-sized residential complexes, and the header branching and semi header methods are deemed to be more favorable for large residential complexes. 4) this study offered design measures for appropriate header system main body pipe diameters, water supply inlet pipe diameters, header system piping methods, application methods for functional auxiliary equipment units, and header system installation spaces and location.

Analysis on Visual Preference Elements of Riverscape Axis (도시하천 류축경의 시각적 선호요소 분석)

  • 김용수;정계순;김수봉
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.26 no.2
    • /
    • pp.101-109
    • /
    • 1998
  • Recently, improvement of the quality of urban riverscape environment has been emphasized not only by landscape architectural field but also by various professionals in planning and ecology. Regarding to this current movement, the aim of this paper is to highlight major visual elements of riverscape axis as a case study of Shinchon River in Taegu City to suggest some basic guidelines for arranging riverscape in urban area. The study was mainly based on Repertory Grid Development method which was developed in Japan. The method is consist of three steps such as decision of element landscape in study area for slide photos, selection of evaluation items for interview and obstraction of proper evaluation factors. The major findings through this study are as follows; 1) The 12 major visual elements which possibly improve riverscape, based on abstraction of proper evaluation factors, are Dunchi, surface of the water,, equipment of river, buildings near riverside, river vertical and horizontal facilities like bridge, fine view, riverbed, water plant, naturalness, water's edge line, harmony and street trees by order. 2) Total numbers of adjective which describe 12 common factors are 25, such as clean, open, stable, quiet, comfortable, friendly, bright, natural etc. In addition, Dunchi was described 337 times by various adjectives, surface of the water was 200 times and arrangement of river was 146 times which is similar result with the order of 12 influential common factors. 3) Therefore, Dunchi, surface of the water and equipment of river are three most important factors which could create better riverscape. These three factors implies us how we supply good quality of urban river environment for the urban residents.

  • PDF

A Metamodeling Approach for Leader Progression Model-based Shielding Failure Rate Calculation of Transmission Lines Using Artificial Neural Networks

  • Tavakoli, Mohammad Reza Bank;Vahidi, Behrooz
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.760-768
    • /
    • 2011
  • The performance of transmission lines and its shielding design during a lightning phenomenon are quite essential in the maintenance of a reliable power supply to consumers. The leader progression model, as an advanced approach, has been recently developed to calculate the shielding failure rate (SFR) of transmission lines using geometrical data and physical behavior of upward and downward lightning leaders. However, such method is quite time consuming. In the present paper, an effective method that utilizes artificial neural networks (ANNs) to create a metamodel for calculating the SFR of a transmission line based on shielding angle and height is introduced. The results of investigations on a real case study reveal that, through proper selection of an ANN structure and good training, the ANN prediction is very close to the result of the detailed simulation, whereas the Processing time is by far lower than that of the detailed model.

A 64 kHz Frequency Control Using BRM for Induction Heating

  • Jamjan, K.;Thepsatorn, P.;Charean, A.;Tipsuwanporn, V.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1857-1861
    • /
    • 2003
  • This paper proposes a method for controlling energy distribution to 1 phase induction heating coil by using the Binary Rate Modulation (BRM) Technique. Such method provides proper frequency to the heating coil's requirement by control the frequency at the resonance point, that is, 64-kHZ frequency band. System design are classified to 2 parts. The first part determines main frequency , and the second part generates the frequency from the 8-bit BRM derived from IC no. PAL22V10 in order to control the frequency for Full-bridge connected inverter when supplying the energy required by the 1 phase induction heating coil. Therefore, efficiency of the energy supply can be increate.

  • PDF

A NEW METHOD TO CALIBRATE THE STELLAR COLOR/SURFACE-BRIGHTNESS RELATION

  • Gould, Andrew
    • Journal of The Korean Astronomical Society
    • /
    • v.47 no.4
    • /
    • pp.153-158
    • /
    • 2014
  • I show that the standard microlensing technique to measure the angular radius of a star using color/surface-brightness relations can be inverted, via late-time proper motion measurements, to calibrate these relations. The method is especially useful for very metal-rich stars because such stars are in short supply in the solar neighborhood where other methods are most effective, but very abundant in Galactic bulge microlensing fields. I provide a list of eight spectroscopically identified high-metallicity bulge stars with the requisite finite-source effects, seven of which will be suitable calibrators when the Giant Magellan Telescope comes on line. Many more such sources can be extracted from current and future microlensing surveys.

The small signal analysis of current-mode controlled converter (전류모드제어형 컨버터의 소신호 제어 특성)

  • Song, Yo-Chang;Kim, Young-Tae;Kim, Cherl-Jim
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.968-970
    • /
    • 2001
  • Recently, the power supply equipments have tendency to take multiple feedback loop paths. In this paper the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the gurantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test results. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency $f_c$ is nearly 1/5 of switching frequency $f_s$, from the experimental result with frequency response analyzer.

  • PDF

The stability analysis of current mode controller considering feedback element (피드백 요소를 고려한 전류모드 제어기의 안정도해석)

  • Kim, Cherl-Jin;Song, Yo-Chang;Jin, Young-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.239-241
    • /
    • 2001
  • Recently the power supply equipments have tendency to take multiple feedback loop paths. In this paper, the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the gurantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test results. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency $f_c$, is nearly 1/5 of switching frequency $f_s$, from the experimental result with frequency response analyzer.

  • PDF

A Study on the stability improvement of current-mode controlled DC-DC Converter (전류제어형 DC-DC컨버터의 안정도 향상에 관한 연구)

  • Kim, Cherl-Jin;Song, Yo-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.365-367
    • /
    • 2000
  • Recently, the power supply equipments have tendency to take multiple feedback loop paths. In this paper, the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the gurantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test results. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency $f_c$ is nearly 1/5 of switching frequency $f_s$ from the experimental result with frequency response analyzer.

  • PDF

Analysis of Demands of Manpower in Southwest Marine Tourism (서.남해안권 관광벨트의 해양관광레저인력 수요 분석)

  • Park, Chang-Kyu
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.13 no.4
    • /
    • pp.87-93
    • /
    • 2007
  • Tourists' needs are changing rapidly and new niche markets, such as nature tourism, eco-tourism, and marine tourism, are flourishing in response to consumer demand. Especially, the estimating demand & supply of manpower in marine tourism is a very important issue for basic tourism HRD policy. This research is focused on the estimation of growing demands of manpower and suggests the method to estimate the proper number of manpower in marine tourism industry.

  • PDF