• Title/Summary/Keyword: Proper Arrangement

Search Result 188, Processing Time 0.025 seconds

Proper Cable Arrangement Selection by Induced Voltage Evaluation of DC Cable in AC/DC Hybrid Combined Transmission Systems (AC/DC 하이브리드형 혼합송전계통에서 DC 케이블의 유도전압평가에 의한 적정배열 선정)

  • Son, Yong-Dae;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.5
    • /
    • pp.680-688
    • /
    • 2015
  • Hybrid type combined transmission systems is being operated by AC and DC line at the same space will be expanded instead of the overhead line. However, such hybrid type combined system has problem like the arrangement selection of DC cable for effective system operation. In this paper, to select the proper arrangement of DC cable, induced voltage of DC cable influenced by AC cable was analyzed in case of several type arrangement of DC cable. Such induced voltage is in detailed analyzed not only in case of steady, but transient state. The arrangement which has the lowest induced voltage is selected as the proper one. EMTP/ATPDraw is used for modeling and analysis of hybrid type combined transmission system.

The Functional Color Arrangement for Industrial Safety in Machinery Work Site 2: Focusing on Chroma Value from Top and Bottom

  • Park, Hyewon;Jang, Seonu
    • Journal of Fashion Business
    • /
    • v.17 no.6
    • /
    • pp.98-110
    • /
    • 2013
  • This research is to study the functional color arrangement of work clothes based on the color chroma value arrangement, which could affect the safety of workers at the site of the mechanical industry. For the study, 5PB hue, indicating a high satisfaction level with proper colors at the site of the mechanical industry, were selected from previous research for 6 types of CAD simulation on a 2-color chroma value arrangement. To analyze the color data of each color arrangement after applying the color chroma value arrangement as well as to figure out the level of recognition on the color arrangement, an analytical result, which was based on the NCS color system, was evaluated. Furthermore, the survey study on items regarding the safety of the relevant work site for the simulated result was executed. As a result of the evaluation, the color arrangements which include high color chroma value indicated a high satisfactory level in all items under the visibility criteria for the safety of workers, propriety as a color arrangement of work clothes, and safety from the perspective of work site management. In particular, the color arrangement mixture between high color chroma obtained the highest satisfactory evaluation, indicating that the color arrangement of high color chroma is essential in the color arrangement of work clothes for the establishment of safety by adjusting the color chroma value. Yet, in order to figure out the independent function of the color chroma value, other factors are restricted in this study. Thus, it is not proper to apply the result of this study only at the actual work site. Therefore, a follow-up research centered on the tones of all three types is proposed, from which we can expect, a suggestion of the applicable color guideline for the industrial site.

Study on the Application of an Expert System to Arrangement Design of Submarine (잠수함 배치 설계에의 전문가 시스템 적용 방안에 대한 연구)

  • Kim, Ki-Su;Ha, Sol;Ku, Namkug;Roh, Myung-Il
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.2
    • /
    • pp.138-147
    • /
    • 2014
  • This paper proposed an application of expert system to submarine arrangement design. Since all components of the submarine should be placed in a restricted place called pressure hull, expert knowledge has great effects on design of submarine arrangement. In this regard, a suitable knowledge-based expert system shell was applied to design of submarine arrangement process. To use expert system on the design of submarine arrangement effectively, a template model for submarine arrangement, which is proper to use in optimum design process, was developed. The proposed system was applied to simplified example of submarine arrangement problem to choose optimal design alternative. From this study, it was verified that expert system could be used in design of submarine arrangement with effect.

Performance Analysis on a Multi-Pass Multi-Branch Heat Exchanger According to Pass Arrangement (다패스 다분지 열교환기의 패스 수에 따른 성능 분석)

  • Kim Min-Soo;Lee Kwan-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.8 s.251
    • /
    • pp.741-748
    • /
    • 2006
  • This paper numerically investigates the effects of pass arrangement on the flow distribution characteristics and the performance of a multi-pass multi-branch heat exchanger. Four cases of pass arrangement (2, 4, 6, 8 pass) are chosen to select a proper pass arrangement. A JF factor is used as an evaluation characteristic value to consider the heat transfer and the pressure drop. The present results indicate that 4-pass heat exchanger shows the best performance, and the design parameters in 4-pass heat exchanger are optimized. The design parameters are the locations of the inlet, outlet and separator, and are optimized using a response surface methodology. The JF factor of the optimum model is increased by about 9.3%, compared to that of the reference model (2-pass heat exchanger).

Effect of Arrangement of Design Elements on Recognition of Complex Signs

  • Ishihara, Maki;Okada, Akira;Yamashita, Kuniko
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.4
    • /
    • pp.143-146
    • /
    • 2007
  • Due to the expansion of cities and the increasing number of large-scale and complex public spaces, there is an increase in public signage. Moreover, the information described on these signs tends to be diverse and complicated. Complex signs that contain multiple destinations or other information must be considered to determine not only the proper size, color, etc. but also the most effective arrangement of design elements. In the previous research, the cognitive utility of complex public signs was estimated using computer simulation software. In the current research, we focused on the objective estimation of the effectiveness of the results obtained in the previous research utilizing an eye mark recording system. Two cognitive engineering experiments clarified five points for improvement in the usability of complex signs, as follows: 1) Parallel construction of characters and pictograms is more efficient. 2) Grouping elements result in rapid recognition of information chunks. 3) Visual characters and pictograms are effective, along with proper density of information. 4) Specific arrangement of sign arrows is effective. 5) Figures on signs influence the sequence of information searches.

Magnetic Field Analysis in Accordance with Line Configuration Type in Underground Transmission Systems (지중송전계통에서 선로의 구성방식에 따른 자계 해석)

  • Lee, Jae-Myeong;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1673-1678
    • /
    • 2015
  • This paper describes magnetic field on power cable in underground transmission systems. Based on specification which is being used in domestic power utility, magnetic field was analyzed in accordance with line arrangement, line burial depth and phase spacing. Magnetic field magnitude and its trend were understood in each circuit type such as double circuits, triple circuits and quadruple circuits of underground transmission systems. In addition, magnetic field was analyzed according to phase arrangement changing in each circuit. Finally, the proper phase arrangement configuration type was suggested by the evaluation of analysis result. Magnetic field was calculated by using Biot-Savart's law. According to the evaluated magnetic fields based on phase layout configuration in each circuit, it figured out that each of magnetic fields was different. As a result, this paper proposes a proper phase layout configuration for generating minimum magnetic field. It is evaluated that the phase layout configuration in each circuit proposed in this paper can be used at actual underground transmission systems.

Countermeasures for reducing the zero sequence circulating current in parallel untranposed 154kV four-circuit systems. (154kV 송전계통 비연가 4회선 병행선로에서의 영상순환전류 감소대책)

  • Yoon, Yong-Beum;Choo, Jin-Boo;Baek, Young-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.913-915
    • /
    • 1996
  • This paper proposes the proper phase arrangement of transmission lines for reducing the zero sequence circulating current. It is a well-known fact that the zero sequence circulating currents are principally caused by the untranposed lines and numerical estimation method already has been established. In this paper, the circuit analysis for calculating the zero sequence circulating currents was performed on the existing 154kV four-circuit systems of KEPCO and the proper phase arrangement was determined.

  • PDF

GRAPHICAL ARRANGEMENTS OF COMPRESSED GRAPHS

  • Nguyen, Thi A.;Kim, Sangwook
    • Honam Mathematical Journal
    • /
    • v.36 no.1
    • /
    • pp.85-102
    • /
    • 2014
  • We show that if a graph G is compressed, then the proper part of the intersection poset of the corresponding graphical arrangement $A_G$ has the homotopy type of a wedge of spheres. Furthermore, we also indicate the number of spheres in the wedge, based on the number of adjacent edges of vertices in G.

TOPOLOGICAL PROPERTIES OF GRAPHICAL ARRANGEMENTS

  • Nguyen, Thi A.;Kim, Sangwook
    • Honam Mathematical Journal
    • /
    • v.36 no.2
    • /
    • pp.435-454
    • /
    • 2014
  • We show that for any graph G, the proper part of the intersection poset of the corresponding graphical arrangement $\mathcal{A}_G$ has the homotopy type of a wedge of spheres. Furthermore, we also indicate the number of spheres in the wedge, based on the number of spanning forests of G and other graphs that are obtained from G.

The Control of the Magnetic Field around Down Conductors (인하도선 주변에서 발생하는 자장의 억제)

  • Lee, Bok-Hee;Kang, Sung-Man;Lee, Seung-Chil;Eom, Ju-Hong;Lee, Kyoung-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.216-218
    • /
    • 2001
  • This paper deals with the control of magnetic field around the down conductor of lightning protection systems. The magnetic field strength in the vicinity of down conductor is shown to drop off rapidly with distance from the down conductor and is reversely proportional to the number of down conductor. Also the magnetic field strength is decreased in the structures as the down conductor is installed with the symmetrical arrangement, and it is zero at the center of symmetry. The magnetic field strengths for the symmetrical arrangement of two down conductors are less than one half compared with that for a down conductor. A proper arrangement of down conductor can reduce or cancel the magnetic field in a restricted place where information-oriented and computerized facilities are densely installed.

  • PDF