• 제목/요약/키워드: Proof test interval

검색결과 4건 처리시간 0.016초

개질형 On-Site 수소충전소의 리스크 감소를 위해 요구되는 SIL 등급 달성 방안에 관한 연구 (A Study on the Achievement of Required Safety Integrity Level to Reduce Risk for SMR On-Site Hydrogen Refueling Stations)

  • 이진호;임재용
    • 한국안전학회지
    • /
    • 제35권6호
    • /
    • pp.1-8
    • /
    • 2020
  • In recent years, hydrogen has received much attention as an alternative energy source to fossil fuels. In order to ensure safety from the increasing number of hydrogen refueling stations, prevention methods have been required. In this regard, this study suggested an approach to reduce the risk of hydrogen refueling station by increasing Safety Integrity Level (SIL) for a Steam Methane Reformer (SMR) in On-Site Hydrogen Refueling Station. The worst scenario in the SMR was selected by HAZOP and the required SIL for the worst scenario was identified by LOPA. To verify the required SIL, the PFDavg.(1/RRF) of Safety Instrumented System (SIS) in SMR was calculated by using realistic failure rate data of SIS. Next, several conditions were tested by varying the sensor redundancy and proof test interval reduction and their effects on risk reduction factor were investigated. Consequently, an improved condition, which were the redundancy of two-out-of-three and the proof test interval of twelve months, achieved the tolerable risk resulting in the magnitude of risk reduction factor ten times greater than that of the baseline condition.

개인적 위험도를 고려한 수소충전소의 안전계장기능 향상에 관한 연구 (A Study on the Improvement of Safety Instrumented Function of Hydrogen Refueling Station Considering Individual Risk)

  • 변윤섭
    • 한국수소및신에너지학회논문집
    • /
    • 제34권3호
    • /
    • pp.297-306
    • /
    • 2023
  • The frequency of fatal accidents that can occur at hydrogen refueling station was compared with the risk criterion for the general public suggested by the health and safety executive. If hydrogen refueling station meets the accident prevention facility standards presented in KGS Code FP216/217, it was confirmed that the risk of hydrogen refueling station was not at an unacceptable (intolerable) risk level. However, the risk of hydrogen refueling station due to small leak was analyzed as low as reasonably practicable. Therefore, methods for improving the safety instrumented function of hydrogen refueling station were reviewed. It was confirmed that the risk of hydrogen refueling station can be affected by the number of installed safety instrumentation system components, redundant architecture, mission time, proof test interval, etc. And methods for maintaining the risk of hydrogen refueling station at an acceptable risk level have been proposed.

Effect of hanging-type sand fence on characteristics of wind-sand flow fields

  • Cheng, Jian-jun;Lei, Jia-qiang;Li, Sheng-yu;Wang, Hai-feng
    • Wind and Structures
    • /
    • 제22권5호
    • /
    • pp.555-571
    • /
    • 2016
  • A hanging-type sand-retaining wall is a very common sand-blocking fence structure used to prevent sand movement. This type of wall is widely used along the Qinghai-Tibet and Gobi desert railways in Xinjiang, Western China. To analyze the characteristics of wind-sand flow fields under the effect of such a sand fence structure, a wind tunnel test and a field test were carried out. The wind tunnel test showed the zoning characteristics of the flow fields under the effect of the hanging-type sand-retaining wall, and the field test provided the sediment transport data for effective wind-proof interval and the sand resistance data in the front and behind the sand-retaining wall. The consistency of the wind-sand flow fields with the spatial distribution characteristic of wind-carried sand motion was verified by the correspondences of the acceleration zone in the flow field and the negative elevation points of the percentage variations of the sand collection rate. The spatial distribution characteristic of the field sand collection data further showed the spatial structural characteristic of the sandy air currents under the action of the hanging-type sand-retaining wall and the sand resistance characteristic of the sand-retaining wall. This systematic study on the wind-sand flow fields under the control of the hanging-type sand-retaining wall provides a theoretical basis for the rational layout of sand control engineering systems and the efficient utilization of a hanging-type sand-retaining wall.

식스시그마 프로젝트에서 연구가설과 통계가설에 의한 통계적 유의성 및 실무적 유의성의 적용방안 (Implementation of Statistical Significance and Practical Significance Using Research Hypothesis and Statistical Hypothesis in the Six Sigma Projects)

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제15권1호
    • /
    • pp.283-292
    • /
    • 2013
  • This paper aims to propose a new steps of hypothesis testing using analysis process and improvement process in the six sigma DMAIC. The six sigma implementation models proposed in this paper consist of six steps. The first step is to establish a research hypothesis by specification directionality and FBP(Falsibility By Popper). The second step is to translate the research hypothesis such as RHAT(Research Hypothesis Absent Type) and RHPT(Research Hypothesis Present Type) into statistical hypothesis such as $H_0$(Null Hypothesis) and $H_1$(Alternative Hypothesis). The third step is to implement statistical hypothesis testing by PBC(Proof By Contradiction) and proper sample size. The fourth step is to interpret the result of statistical hypothesis test. The fifth step is to establish the best conditions of product and process conditions by experimental optimization and interval estimation. The sixth step is to draw a conclusion by considering practical significance and statistical significance. Important for both quality practitioners and academicians, case analysis on six sigma projects with implementation guidelines are provided.