• Title/Summary/Keyword: Pronation

Search Result 149, Processing Time 0.03 seconds

The Result of Conservative Treatment in Displaced Radial Head Fracture (전위된 요골두 골절의 보존적 치료의 결과)

  • Yi, Seung-Rim;Hahn, Sung-Ho;An, Young-Joon;Yoo, Jae-Ho;Jeon, Do-Whan;Yang, Bo-Kyu
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.4 no.1
    • /
    • pp.43-48
    • /
    • 2005
  • Purpose: The purpose of this study is to assess the result of conservative treatment in displaced radial head fracture. Materials and Methods: We analyzed 15 cases of displaced radial head fracture who were treated conservatively from April 1992 to May 2002. Follow-up period was more than 1 year. They were all males and the average age of patients was 20.2($11{\sim}24$) years. The average follow-up period was 13.4($12{\sim}15$) months. They were able to do active pronation and supination more than 70 degrees initially, who were applied long arm splint less than 1 week. The functional rating index modified after B.F. Morrey and no further displacement and union state of fragment in simple X-ray were used in follow-up assessment. Results: On the basis of the functional rating index modified after B.F. Morrey that included elements of pain, motion, strength, and stability, the results were 8 excellent, 7 good in patients who were treated conservatively, who had union and no further displacement of fragment in follow-up. Conclusion: We conclude that if they are able to do active pronation and supination more than 70 degrees initially, we take them to do early range of motion exercise after subsiding swelling, which can restrict limitation of range of motion exercise and return to the living early.

  • PDF

Effects of the Ergonomic Lap Board for Computer Mouse Padding on Upper Limb Movements, Myoelectric Activities, Task Performance, and Subjective Discomfort (인체공학적 랩보드를 이용한 컴퓨터 마우스 사용이 상지의 움직임 및 근활성도, 작업수행도, 주관적 불편도에 미치는 영향)

  • Park, So-Yeon;Lee, Taek-Young;Yi, JinBock
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.2
    • /
    • pp.348-358
    • /
    • 2013
  • This study aimed to investigate the effect of a lap board that was developed to prevent musculoskeletal disorders caused by the use of a computer mouse. Study participants were 10 college students in their 20s who did not have any musculoskeletal symptoms. We analyzed the difference in upper limb movements, electromyographic activity, task performance, and subjective discomfort between 2 conditions: use of a mouse with the lap board and use of a mouse placed on a desk. Results of behavior analysis showed that there was a significant difference between the 2 conditions in terms of the average angle of shoulder flexion, shoulder internal rotation, and forearm pronation(p< 0.05). However, electromyographic activity, task performance, and subjective discomfort showed no significant differences between the 2 conditions. When subjects used the mouse with the lap board, their upper extremity was located much closer to the torso than when they used the mouse placed on the desk. Six of 10 participating students preferred the lap board. We expect that advanced research on prevention of musculoskeletal disorders due to the use of the computer mouse will be conducted in the near future.

Results of Syndesmotic Screw Fixation versus Posterior Malleolus Fixation in Syndesmotic Injury at Pronation External Rotation Stage IV Ankle Fracture with Posterior Malleolus Fracture: Postoperative One Year Follow-up (후과 골절을 동반한 Lauge-Hansen 회내-외회전형 4단계 족관절 골절에서 원위 경비인대 결합 손상에 대한 원위 경비 나사 고정술과 후과 고정술의 결과 비교: 수술 1년째 추시 결과)

  • Park, Se-Jin;Jeong, Hwa-Jae;Shin, Hun-Kyu;Seo, Dong-Seok;Choi, Young-Min;Kim, Eugene
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.1
    • /
    • pp.29-35
    • /
    • 2014
  • Purpose: The purpose of this study is to compare the radiologic and clinical results of syndesmotic screw fixation and posterior malleolar fixation for syndesmotic injury in Lauge-Hansen classification pronation-external rotation (PER) stage IV ankle fractures with posterior malleolus fracture. Materials and Methods: We designed a retrospective study that included patients with Lauge-Hansen classification PER stage IV ankle fracture with posterior malleolus fracture. Of 723 patients who underwent ankle fracture surgery from March 2005 to November 2012, 29 were included in this study. In this study, syndesmotic injury was treated with syndesmotic screw fixation or posterior malleolus fixation. There were 15 cases of syndesmotic screw fixation and 14 cases of posterior malleolar fixation. We compared the radiologic and clinical results at one year postoperatively. Posterior malleolus fragment size on a pre-operative computed tomographic image, and tibiofibular overlap, medial clear space, articular step-off, Kellgren-Lawrence grade, and Takakura classification on a postoperative one year followup radiograph were used for comparison of the radiologic results. The clinical results were assessed using the American Orthopaedic Foot and Ankle Society score, visual analogue scale score, and patient subjective satisfaction score. Results: Posterior malleolar fragment size was $12.62%{\pm}3.01%$ of the joint space in the syndesmotic screw fixation group and $27.04%{\pm}4.34%$ in the posterior malleolar fixation group. A statistical difference was observed between the two groups. However, other results, including tibiofibular overlap, medial clear space, articular step-off, Kellgren-Lawrence grade, Takakura classification, and clinical scores showed no statistical difference. Conclusion: In the Lauge-Hansen classification PER stage IV ankle fracture with posterior malleolus fracture, if the posterior malleolus fracture can be reduced anatomically and fixated rigidly, syndesmotic screw fixation, which can cause several complications, is usually not required for achievement of a satisfactory syndesmotic stability; this would be a recommendable option for treatment of syndesmotic injury.

The Scientific Analysis of Aged' Shoe for Health Promotion (노인 건강증진용 신발의 운동과학적 효과분석)

  • Jin, Young-Wan;Kwak, Yi-Sub
    • Journal of Life Science
    • /
    • v.21 no.9
    • /
    • pp.1336-1345
    • /
    • 2011
  • The purpose of this study was to analyze and compare the effects of exercise science of shoes for Aged' health promotion. Kinematic and kinetic data were collected using cinematography and the Zebris system (Zebris Emed Sensor Platform, GR-DVL9800) to analyze pressure of foot and ground reaction force. Subjects recruited were 20 healthy elderly men. They walked at 1.36m/sec velocity wearing type A (domestic), type B (foreign) and walking shoes (A company). One-way ANOVA was used to analyze statistics. The results were as following: no significant differences were observed in gait variables among the three groups (p<0.05). There was a significant difference in max pronation angle of heels examined among the three groups (p<0.05). There were no significant differences in kinetic variables (ground reaction force and max pressure) among the three groups (p<0.05). A physiology study was performed to analyze the effects of walking with shoes with silver added to them on percent body fat, resting metabolic rate and energy expenditure. Sixty adults males were recruited from the public health center. They were divided into four groups. C: control group (n=20), EY: elderly Y group (n=20), and EO: elderly O group (n=20). The results of this study were as follows: percent body fat was decreased following each exercise period, however, not all the groups showed a significant difference. The change of resting metabolic rate was significantly increased in HI (high intensity) and LI (low intensity) periods in the C and EY groups. However, there was no significant difference in the EO group. The mean energy expenditure during and after exercise were significantly lowered in all periods compared to the control group.

The Influence of Wedged Insoles on Lower Extremity Joints during Gait (경사진 안창이 보행시 하지관절에 미치는 영향)

  • Kwon, Min-Jeong;Choi, Hwa-Soon;Chung, Min-K.;Na, Seok-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.19-27
    • /
    • 2007
  • Despite the widespread use of laterally wedged insoles for patients with knee osteoarthritis and medially wedged insoles for controlling rearfoot pronation, an understanding of the effects of wedged insoles was limited and sometimes controversial. The objective of this study was to evaluate the effect of wedged insoles on the kinematics and kinetics of normal gait. Ten male subjects without history of lower limb disorders were recruited. Each subject performed four gait cycles under each of seven conditions; shod with 5$^{\circ}$, 8$^{\circ}$ and 15$^{\circ}$, 8$^{\circ}$ and 15$^{\circ}$ laterally wedged insoles. In order to determine statistical differences among seven conditions, the measured temporal spatial variables, angular displacements, joint moments, and ground reaction forces were compared with a one-way analysis of variance. Some significant changes induced by wedged insoles were apparent in joint moments and ground reaction forces. The medially wedged insole increased the laterally directed ground reaction force and varus moments at the ankle force and varus moments at the ankle and the knee.

The Study of 3D Motion Analysis on Lower Limb during Walking with Walker on Older People (노인의 워커 사용에 따른 보행 시 하지 관절 3차원 동작 분석에 관한 연구)

  • Kim, Seonchil;Lee, Sangyeol
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.5 no.1
    • /
    • pp.19-24
    • /
    • 2017
  • Purpose : The purpose of this study was to find out the difference motion of hip, knee and ankle joint during walking according to using walker on older people. Method : Korean older people of 34 subjects was participated in this study. Participants was measured joint motion on hip, knee and ankle joint during both conditions (walking with walker and without walker). The measured data were analyzed using independent t-test to investigate the difference of joint motion on the both condition. The statistical analyses were performed using Predictive Analytics Soft Ware (PASW) for windows(Ver. 19) and p-value less than .05 were considered significant for all cases. Result : The study showed that more joint motion on hip flexion and ankle pronation is increased by using walker. And hip extension, knee external rotation and ankle plantar flexion is decreased by using walker. Conclusion : This study suggest that using walker on older people was change the motion of the lower limb joint during walking. Therefore, It is necessary to develop a new walker that can reduce dependency and ensure stability on older people during walking.

The Comparative Analysis on Mechanical Property Test of Carbon Nanotube-based Shock Absorbers (탄소나노튜브를 기반으로 하는 충격흡수제의 물리적 특성 비교분석)

  • Kim, Jong-Woo;Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.2
    • /
    • pp.237-242
    • /
    • 2012
  • The purpose of this study was (a) to develop carbon nanotube-based shock absorbers for reducing potentially harmful impact forces and excessive foot pronation, and (b) to briefly determine how the effects of carbon nanotube-based shock absorbers on biomechanical variance during drop landing. A university student(age: 24.0 yrs, height: 176.2 cm, weight: 679.5 N) who has no musculoskeletal disorder was recruited as the subject. Hardness, specific gravity, tensile strength, elongation, 100% modulus, tear strength, split tear strength, compression set, resilience, vertical GRF, and loading rate were determined for each material. For each dependent variable, a descriptive statistics was used for different conditions. The property test results showed that tensile strength, tear strength, split tear strength, compression set, and resilience in carbon nanotube-based shock absorbers were greater than general Ethylene Vinyl Acetate(EVA). These indicated that resistance against variable strength in developed carbon nanotube-based shock absorbers were greater than general EVA. In vertical GRF of CNTC was less than those of EVA during drop landing and loading rate of CNTC was greater than EVA. It seems that the use of CNT can be a effective way of reducing and controlling shock from impact.

Simultaneous reconstruction of the forearm extensor compartment tendon, soft tissue, and skin

  • Oh, Jeongseok;Ahn, Hee Chang;Lee, Kwang Hyun
    • Archives of Plastic Surgery
    • /
    • v.45 no.5
    • /
    • pp.479-483
    • /
    • 2018
  • Malignant peripheral nerve sheath tumor (MPNST) is a very rare type of sarcoma, with an incidence of 0.001%. MPNST has a 5-year survival rate near 80%, so successful reconstruction techniques are important to ensure the patient's quality of life. Sarcoma of the forearm is known for its poor prognosis, which leads to wider excision, making reconstruction even more challenging due to the unique anatomical structure and delicate function of the forearm. A 44-year-old male presented with a large mass that had two aspects, measuring $9{\times}6cm$ and $7{\times}5cm$, on the dorsal aspect of the right forearm. The extensor compartment muscles (EDM, EDC, EIP, EPB, EPL, ECRB, ECRL, APL) and invaded radius were resected with the mass. Tendon transfer of the entire extensor compartment with skin defect coverage using a $24{\times}8cm$ anterolateral thigh (ALT) perforator free flap was performed. The patient was discharged after 18 days without wound complications, and has not complained of discomfort during supination, pronation, or wrist extension/flexion through 3 years of follow-up. To our knowledge, this is the first report of successful reconstruction of the entire forearm extensor compartment with ALT free flap coverage after resection of MPNST.

The Reliability of Kinematic Analysis for Distal Upper Extremity in Normal Person (정상인의 상지 원위부에 대한 운동학적 분석의 신뢰도)

  • Byun, Jae-Hyun;Hong, Wan-Ki
    • Journal of Applied Reliability
    • /
    • v.16 no.2
    • /
    • pp.147-154
    • /
    • 2016
  • Purpose: To evaluate statistical differences among three measurements of range of motion (ROM) with Rapael Smart Glove (RSG) group 1, 2 and manual goniometer group. To investigate reference value of the kinematic analysis for range of motion (ROM) of distal upper extremity with Rapael Smart Glove (RSG). Methods: Sixteen normal persons without limitation of motion (LOM) enrolled in the study. The study was performed at two separate times and by two investigators on 16 normal adults. We compared ROM with RSG for measuring joint angles. We compared degrees of forearm supination/pronation, wrist flexion/extension and radial deviation/ulnar deviation during ROM of 16 participants using RSG. After one week, degrees of each motion were measured in the same way by other investigator to evaluate the reliability. Results: Statistical differences among three groups were showed. Most results of paired t-test between two RSG groups were over 0.05 and exceptions are supination, extension, and finger %. Conclusion: Our findings demonstrate that ROM of normal persons obtained by kinematic analysis with RSG are not valid as normal reference value for distal upper extremity motion. But, the reliability of between two RSG groups was showed with paired t-test and Pearson's correlation except supination, extension and finger %.

Development of the Myoelectric Hand with a 2 DOF Auto Wrist Module (2 자유도 자동손목관절을 가진 근전 전동의수 개발)

  • Park, Se-Hoon;Hong, Beom-Ki;Kim, Jong-Kwon;Hong, Eyong-Pyo;Mun, Mu-Seong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.8
    • /
    • pp.824-832
    • /
    • 2011
  • An essential consideration to differentiate prosthetic hand from robot hand is its convenience and usefulness rather than high resolution or multi-function of the robot hand. Therefore, this study proposes a myoelectric hand with a 2 DOF auto wrist module which has 6 essential functions of the human hand such as open, grasp, pronation, supination, extension, flexion, which improves the convenience of the daily life. It consists of the 3 main parts, the myoelectric sensor for input signal without additional attachment to operate the prosthetic hand, hand mechanism with high-torqued auto-transmission mechanism and self-locking module which guarantee the safety under the abrupt emergency and minimum power consumption, and dual threshold based controller to make easy for adopting the multi-DOF myoelectric hand. We prove the validity of the proposed system with experimental results.