• 제목/요약/키워드: Progressive Intervention

검색결과 90건 처리시간 0.029초

설하신경마비를 동반한 설골골절: 증례보고 (Hyoid Bone Fracture Associated with Hypoglossal Nerve Palsy: A Case Report)

  • 김신락;박진형;한예식
    • Archives of Plastic Surgery
    • /
    • 제38권2호
    • /
    • pp.199-202
    • /
    • 2011
  • Purpose: Hyoid bone is a U-shaped bone in the anterior of the neck. Hyoid bone fractures are exceedingly rare and represent only 0.002% of all fractures because of its protective position relative to the mandible and its suspension by elastic musculature. We report a patient who presented hyoid bone fracture associated with hypoglossal nerve palsy. We also discuss the possible complication and treatment. Methods: A 69-year-old man was transferred from another institution because of persistent purulent discharge from the left chin. He had a history of trauma in which a knuckle crane grabbed his face and neck in the construction site. A CT scan at the time of the accident demonstrated a comminuted fracture of the right side of the mandible and hyoid bone fracture at the junction between body and right greater cornua. The displaced fracture of hyoid bone and fullness in the pre-epiglottic space were noted, probably indicating some edema. The patient was transferred into ICU after treatment of emergency tracheostomy because the patient showed respiratory distress rapidly. When the patient was hospitalized in our emergency room, he complained of dysphagia and pain when swallowing. On examination of oral cavity, the presence of muscle wasting with fasciculation of the tongue was noted and the tongue deviates to the left side on protruding from the mouth. Pharyngolarygoscopy was performed to make sure that there was no evidence of progressive swelling and pharyngeal laceration. Results: The patient underwent surgical removal of dead and infected tissue from the wound and reconstruction of mandibular bony defect by iliac bone grafting. Hyoid bone fracture was managed conservatively with oral analgesics, soft diet and restricted movement. Hypoglossal nerve palsy was resolved within 7 weeks after trauma without complications. Conclusion: Closed hyoid bone fracture is usually uncomplicated and thus it can be treated conservatively. Surgical intervention for hyoid bone fracture is recommended for patient with airway compromise, pharyngeal perforation and painful symptoms which show no response to conservative care. Furthermore, since respiratory distress syndrome may develop quickly, close observation is required. Besides, hypoglossal nerve palsy is a rarely recognized complication of hyoid bone fracture.

반안면 왜소증 환자에서의 골신장술: 증례보고 (THE USE OF DISTRACTION OSTEOGENESIS TO TREAT HEMIFACIAL MICROSOMIA: A CASE REPORT)

  • 백성문;김수관;김학균;문성용
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권5호
    • /
    • pp.559-566
    • /
    • 2007
  • Distraction osteogenesis(DO) is a surgical method of bone formation that involves an osteotomy and sequential stretching of the healing callus by gradual movement and subsequent remodeling. DO is used to correct facial asymmetry, such as in patients with hemifacial microsomia, maxillary or mandibular retrusion, cleft lip and palate, alveolar defects, and craniofacial deficiency. It is accomplished with the aid of a distraction device, which is secured with screws placed directly into bone, for a predetermined length of time. Hemifacial microsomia is characterized by unilateral facial hypoplasia, often with unilateral shortening of the mandible and subsequent malocclusion. Patients with hemifacial microsomia and facial asymmetry have a vertically short maxilla, tilted occlusal plane, and short mandible. Early treatment is necessary to avoid subsequent impaired midfacial growth. The standard treatment of these malformations consists of the application of bone grafts, which can lead to unpredictable growth. The new bone-lengthening procedure represents a limited surgical intervention and opens up a new perspective for treatment, especially in younger children with severe deformities. This report describes a case of hemifacial microsomia(Type-II left-sided hemifacial microsomia). The patient, a 10-year-old child, visited our clinic for facial asymmetry correction. He had a hypoplastic mandible, displaced ear lobe, 10 mm canting on the right side, and malocclusion. We planned DO to lengthen the left mandible in conjunction with a Le Fort I osteotomy for decanting and then perform a right intraoral vertical ramus osteotomy(IVRO). Progressive distraction at a rate of 0.5 mm/12 hours was initiated 7 days postoperatively. The duration of DO was 17 days. The consolidation period was 3 months. Satisfactory results were obtained in our case, indicating that DO can be used successfully for functional, aesthetic reconstruction of the mandible. We report a case involving DO in conjunction with orthognathic surgery for correcting mandibular hypoplasia with a review of the literature.

물리치료사와 물리치료과 학생의 성별에 따른 HIV/AIDS 에 대한 지식과 태도 (Difference of Knowledge and Attitudes toward HIV/AIDS between Genders of Physical Therapists and Physical Therapy Students)

  • 안소윤;김종순
    • 대한정형도수물리치료학회지
    • /
    • 제11권2호
    • /
    • pp.26-39
    • /
    • 2005
  • The purpose of this descriptive study is to investigate the general knowledge and attitude about HIV/AIDS among gender in physical therapists and physical therapy students. AIDS a clinical syndrome that involves progressive immune deficiency and consequent development of opportunistic infection, tumors, neurologic disease and systemic wasting with chronic trends. Many medical specialists are afraid of AIDS patients because they have a little information of AIDS and fear of HIV infection from AIDS patients at work site. This study surveyed 649 physical therapists and physical therapy students by means of a self-administered questionnaire. This study was carried out from April, 2003 to October, 2003 for collecting data. The findings of this study can be summarized as follows. 1) The male and female physical therapist and physical therapy students who have an experience of educational program for HIV/AIDS show higher general knowledge about HIV/AIDS. 2) The male physical therapist and physical therapy students were conscious of the need for physical therapeutic intervention for the complication of HIV/AIDS. 3) The male who has higher general knowledge about HIV/AIDS are conscious of the need for educational program about HIV/AIDS. 4) The male and female want to have the choice to accept or reject the HIV/AIDS patients for treatment. 5) The knowledge of transmission mode in sexual intercourse of HIV/AIDS influence the attitude of male and female to patients with HIV/AIDS. 6) The knowledge of prevention of HIV/AIDS influence the attitude of male and female to patients with HIV/AIDS. 7) The knowledge of regarding symptom of HIV/AIDS influence the attitude of female to patients with HIV/AIDS. 8) The knowledge of general transmission mode of HIV/AIDS influence the attitude of male and female to patients with HIV/AIDS. 9) The knowledge of transmission risk factors in work site of HIV/AIDS influence the attitude of male and female to patients with HIV/AIDS. 10) The knowledge of needs for prevention in work site of HIV/AIDS influence the attitude of male and female to patients with HIV/AIDS. In conclusion, male and female with more knowledge of HIV/AIDS could positively treat HIV/AIDS patients.

  • PDF

혈액암 환자의 원내 사망률에 미치는 신속대응팀의 효용성 (Effectiveness of Rapid Response Team on In-hospital Mortality in Patients with Hematologic Malignancy)

  • 박소정;홍상범;임채만;고윤석;허진원
    • 한국의료질향상학회지
    • /
    • 제27권2호
    • /
    • pp.18-29
    • /
    • 2021
  • Purpose: Patients with hematologic malignancy (HM) typically have a high mortality rate when their condition deteriorates. The chronic progressive course of the disease makes it difficult to assess the effect of intervention on acute events. We investigated the effectiveness of a rapid response team (RRT) on in-hospital mortality in patients with HM. Methods: We retrospectively analyzed the data of patients with HM who admitted to the medical intensive care unit between 2006 and 2015. Clinical outcomes before and after RRT implementation were evaluated. Results: A total of 228 patients in the pre-RRT period and 781 patients in the post-RRT period were included. The overall in-hospital mortality was 55.4%. Patients in the post-RRT period had improved survival; however, they required more vasopressor therapy, continuous renal replacement therapy, and extracorporeal membrane oxygenation. Multivariate analysis revealed that in-hospital mortality was associated with RRT activation (hazard ratio [HR], 0.634; 95% confidence interval [CI], 0.498-0.807; p < .001), neurological disease (HR, 2.007; 95% CI, 1.439-2.800; p < .001), sequential organ failure assessment score (HR, 1.085; 95% CI, 1.057-1.112; p < .001), need for continuous renal replacement therapy (HR, 1.608; 95% CI, 1.206-1.895; p< .001), mechanical ventilation (HR, 1.512; 95% CI, 1.206-1.895; p< .001), vasopressor (HR, 1.598; 95% CI, 1.105-2.311; p = .013), and extracorporeal membrane oxygenation (HR, 1.728; 95% CI, 1.105-2.311; p = .030). Conclusion: RRT activation may be associated with improved survival in patients with HM.

두 개의 입구를 통한 내시경 척추 수술: 요추부 추간판 탈출증에의 적용 (Biportal Endoscopic Spinal Surgery for Lumbar Intervertebral Disc Herniation)

  • 이호진;최대정;박유진재진
    • 대한정형외과학회지
    • /
    • 제54권3호
    • /
    • pp.211-218
    • /
    • 2019
  • 추간판 탈출증이란 추간판이 정상적으로 위치해야 할 자리에서부터 추간판 내부의 수핵이나 섬유륜이 탈출하는 질환을 지칭하며, 대부분 양호한 자연 경과를 거친다. 하지만 심각한 신경학적 증상이 있거나, 악화되는 신경 증상, 마미 증후군이 동반된 경우, 보존적 치료에 반응하지 않는 경우 등에 대해서는 수술적 치료가 권고된다. 수술 방법에는 고식적인 관혈적 방법, 현미경을 이용한 방법, 통형 견인기(tubular retractor)를 이용한 방법, 그리고 내시경을 이용한 방법에 이르기까지 다양한 방법들이 소개되었는데, 그 중 현미경적 추간판 제거술이 현재 표준 치료로 간주되고 있다. 내시경을 이용한 방법 중에서 두 개의 입구를 통한 내시경 척추 수술(biportal endoscopic spinal surgery, BESS)의 경우, 다른 방법에 비해 수술 기구들의 독자적인 움직임이 가능하여 자유로운 조작이 가능하며, 재발된 추간판 탈출증에 대해서도 추간판 제거가 비교적 수월하게 시행되고, 작은 피부 절개로 넓은 시야 확보가 가능하며, 지속적인 생리식염수의 세척으로써 습기나 안개를 지속적으로 제거해야 되는 번거로움을 덜 수 있고 술 후 감염률을 낮추는 효과도 있다. 기존의 관절경 및 척추 수술 기구들을 그대로 쓸 수 있다는 장점도 있으며, 약 2,700-6,700 lux의 밝은 조도 하에 최대 28-35배로 확대된 영상으로 수술하기 때문에 섬세한 조작이 가능하다. 따라서 이러한 장점을 지닌 두 개의 입구를 통한 BESS는 요추부 추간판 탈출증에 대한 이상적인 수술 방법으로 생각된다.

2019년 유럽의회선거의 함의: 극우 포퓰리즘과 중도자유주의의 부상 (Results of the 2019 European Parliament Elections: The Rise of Far-right Populism and Liberal Centrism)

  • 오창룡
    • 의정연구
    • /
    • 제25권2호
    • /
    • pp.5-33
    • /
    • 2019
  • 본 연구는 2019년 유럽의회선거 결과의 함의를 분석하는 것을 목표로 한다. 기존 연구는 유럽의회선거가 국내 이슈에 의해 좌우되는 부차적인 선거로 기능한다고 분석해왔으나, 이번 선거는 브렉시트 협상과 극우 포퓰리즘 부상이라는 유럽 쟁점이 부각됐으며, 투표율도 크게 상승하여 2000년대 이후 최고 수치인 50.62%를 기록했다. 각 정치그룹별 의석수에도 큰 변화가 있었다. 첫째, 유럽의회를 이끌어 오던 유럽인민당그룹(EPP)과 유럽사회민주그룹(S&D)은 과반 의석을 달성하는 데에 실패했다. 둘째, 중도자유주의그룹인 리뉴유럽(Renew Europe)의 의석수가 크게 증가했다. 셋째, 극우 정치그룹은 정체성과민주주의그룹(ID)을 중심으로 결집하여 본격적인 정치세력화를 시도했다. 중도자유주의의 부상은 반-유럽 포퓰리즘 인기에 대한 반작용으로 볼 수 있다. 특히 중도우파와 중도좌파 그룹이 이민통제와 안보, 고용과 복지를 위한 국가개입 필요성을 강조했기 때문에 리뉴유럽그룹의 개방시장경쟁에 대한 강조는 차별화되는 쟁점을 형성했다. 극우 포퓰리즘과 함께 중도자유주의가 유럽의 정치 균열을 새롭게 재편했으며, 유럽의회에서 '자유주의' 대 '보호주의'의 대립구도가 보다 선명해졌다.

전이성 척추 종양의 수술적 치료 (Surgical Treatment for Metastatic Spinal Tumor)

  • 한정수;김기택;소재호;이정희;신동준
    • 대한골관절종양학회지
    • /
    • 제6권1호
    • /
    • pp.1-9
    • /
    • 2000
  • 목적 : 전이성 척추 종양은 가장 흔한 전이성 종양 중의 하나로 치료에 있어 보통 보존적 요법이 선호되어 왔으나 신경학적 증상과 삶의 질의 개선이 극히 불량하였다. 수술적 치료 후에 신경학적 증상의 변화와 임상증상의 개선정도, 생존 기간의 증가 등에 대해 평가하였다. 대상 및 방법 : 1991년 8월부터 1999년 6월까지 본원에서 경험하였던 전이성 척추 종양 중 수술적 치료 후 추시관찰이 가능하였던 14례를 대상으로 하여 의무기록과 방사선학적 검사 등을 후향적으로 검토하여 연령별, 성별, 해부학적 발생 부위별 분포와 각각의 원발 종양에 따른 골 전이의 양상에 대해 조사하였고, 방사선 치료로 도움이 안될 때, 신경학적 증상이 악화될 때, 척추 불안정성이 있을 때, 원발 종양을 알지 못할 때, 병적 골절이 있을 때, 기대여명이 6주 이상일 때, 만성적인 통증이 있을 때 시행하였던 수술적 치료 전후의 증상의 개선 정도를 평가하여 문헌 고찰과 함께 분석하였다. 결과 : 전이성 척추 종양은 여자에서 더 많이 발생하였고 30대에서 70대까지 연령이 다양하였으며 원발 종양으로 여자는 유방암, 남자는 폐암이 가장 많았고 가장 흔한 전이 부위는 흉추부였다. 수술 전 마비의 정도가 수술 후 임상 증상의 호전에 영향을 미친 것으로 나타났으며 수술 후 전이성 척추 종양의 평균 여명은 사망한 11례에서 8.9개월, 살아있는 3례에서 14.7개월이었다. 결론 : 전이성 종양에 대한 수술적 치료는 전이성 척수 종양이 의심될 때, 치료와 동시에 조기 진단이 가능하며 그 방법과 관계없이 동통과 신경학적 증상의 회복에 큰 도움을 줄 수 있고, 초기의 적극적 치료로 삶의 질과 생존 기간을 향상시킬 수 있다. 추후 원발 종양의 종류에 따른 전이성 척수 종양의 분류와 이에 따른 수술적 치료의 역할에 대한 평가가 더 필요하리라 사료된다.

  • PDF

Tethered cord 증후군에서 비뇨기계 증상 및 검사 소견 (Urological Manifestations and Laboratory Findings in Patients with Tethered Cord Syndrome)

  • 정태성;김은정;이은실;신손문;문한구;박용훈
    • Childhood Kidney Diseases
    • /
    • 제1권2호
    • /
    • pp.155-160
    • /
    • 1997
  • 목적 : Tethered cord 증후군은 척수내 지방종이나 종사의 섬유대 등에 의해 척수 원추가 천골에 부착, 견인됨으로 하지의 신경 결함이나 족부의 변형을 일으키는 질환군으로 척추 유합부전증의 경우에서 흔히 나타난다. 신경학적 소견 외에 빈뇨, 요실금, 유뇨증, 급뇨, 배뇨 감각 장애 등의 비뇨기계 증상도 높은 빈도로 나타난다고 하며 수술적 치료의 예후는 조기에 진단될수록 양호하다고 알려져 있다. 그러나 tethered cord 증후군에서 나타나는 비뇨기계 증상 및 소견에 관하여 체계적으로 보고된 것이 많지 않다. 저자들은 tethered cord 증후군에서의 비뇨기계 증상을 여러 특징을 파악하여 tethered cord 증후군 환자에서의 조기 진단 및 치료 방침 설정에 도움을 얻고자 본 연구를 시행하였다. 대상 및 방법 : 1991년 11월부터 1997년 7월까지 5년 9개월간 영남 대학 병원에서 tethered cord 증후군으로 진단받은 소아 환자 9례를 대상으로 연령 및 성별분포, 비뇨기계 이상에 관한 증상 및 비정상 검사소견의 여부와 수술 후 경과에 대하여 의무 기록을 조사하는 후향적 연구로 조사하였다. 결 과: 1) 대상 환아 9례의 연령 분포로는 0-2세가 5례, 2-6세가 1례. 6-10세가 3례였으며 남아가 2례, 여아는 1례였다. 2) 요실금, 빈뇨, 유뇨증, 급뇨, 배뇨 감각 장애 등의 비뇨기계 증상을 가진 경우가 6례였으며, 비뇨기계의 방사선학적 검사에서 신경성 방광을 보인 경우가 5례, 수신증과 수뇨관증이 동반된 경우가 3례, 방광-요관 역류를 보인 경우가 3례였다. 3) 요동력학적 검사는 3례에서 시행되었으며 3례 모두에서 이상 소견이 발견되었다. 4) 진단시 비뇨기계 증상 및 이상 검사 소견을 가진 7례 중 5례에서 detethering이 행해졌으나 증상의 호전은 1례에서만 관찰되었다. 결론 : Tethered cord 증후군에서 비뇨기계의 증상 및 비정상 검사 소견이 동반되는 경우가 흔하며 비뇨기계의 이상을 시사하는 증상이 없는 경우에도 검사상 이상이 발견되는 경우가 적지 않다. Tethered cord 증후군 환아의 평가는 신경학적 이상 유무는 물론이고 비뇨기계의 이상 여부에 대한 평가도 필히 포함되어야 할 것으로 생각된다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF