• 제목/요약/키워드: Progesterone Assay

검색결과 73건 처리시간 0.028초

소의 조기 임신진단 kit의 개발 II. 조기 임신진단 kit의 개발 (A study on production of early pregnancy diagnostic kit in cattle II. Production of early pregnancy diagnostic kit)

  • 강정부;이행종;최상용
    • 대한수의학회지
    • /
    • 제31권2호
    • /
    • pp.223-228
    • /
    • 1991
  • Most progesterone enzyme immunoassays(EIA) are used liquid-phase double-antibody or single-antibody seperation. These methods consume considerable time and reagents because of the requirements for several washing and centrifugation steps involving the reactants. Because of these several problems, we were prompted to develop an effective enzyme-linked immunosorbent assay(ELISA) system that would be equal or superior to RIA for assay of progesterone. The results were obtained as follows. 1. Cross reaction of the progesterone antiserum with other steroids determined was shown with progesterone(100%), $11{\alpha}$-deoxycorti-costerone(2.271%), but the other steroids were shown below 0.9%. 2. Standard curve for progesterone ELISA was shown available difference according to progesterone concentration from 0 to 1,000pg/ml. 3. The lower limit of sensitivity was 0.2pg/well 4. Progesterone concentration was 1.6ng/ml for before parturition, and that was below 0.5ng/ml for after parturition. This development enzyme-linked immunosorbent assay for progesterone can be detected pregnancy diagnosis in cattle, and also applicable 10 research on physiological function including such as reproductive disorders.

  • PDF

Enzyme immunoassay(EIA)에 의한 소의 progesterone 측정과 이의 응용에 관한 연구 II. Progesterone 측정에 대한 효소면역측정방법(酵素免疫測定方法)의 확립 (Studies on enzyme immunoassay for determining progesterone of bovine plasma and its clinical application. II. Establishment of enzyme immunoassay for progesterone)

  • 강정부;신종욱;최상용
    • 대한수의학회지
    • /
    • 제29권1호
    • /
    • pp.21-25
    • /
    • 1989
  • This experiment was carried out to determine the progesterone concentration of bovine plasma by liquid phase double antibody enzyme immunoassay. The optimum conditions of assay-system, enzyme conjugate and gelatin were invested. The sensitivity, recovery rate and reproducibility by this assay were also analyzed. The results obtained were as follows: 1. The suitable supplementation level of gelatin was 0.2%. As the gelatin level increased to 1%, coefficient variation of interassay was shown to be irregular. 2. The optimum dilution rate of enzyme conjugate was 30 times. Enzyme activity was greatly fluctuated depending on the minor condition of enzyme conjugate technique. Therefore, it was considered to be checked when determined. 3. The sensitivity of the assay was 12 pg/tube. 4. Recovery rate was decreased when the amount of sample was too little or too much, but the recovery rate was high as 97.8% when the amount of sample between 50 and $200{\mu}l$. 5. Mean intra-assay and inter-assay coefficient of variation was 4.5% and 5.9%, respectively. By using liquid phase double antibody enzyme immunoassay, progesterone in plasma can be detected, and also this assay system is applicable to study on physiological function of progesterone and to diagnosis of reproductive disorders.

  • PDF

Progesterone의 단크론성 항체에 관한 특성 및 활용에 관한 연구 II. ELISA 기법의 개발 (Characteristics and application of monoclonal antibody to progesterone II. Development of progesterone enzyme-linked immunosorbent assay(ELISA))

  • 강정부;김종수
    • 대한수의학회지
    • /
    • 제31권4호
    • /
    • pp.403-409
    • /
    • 1991
  • Progesterone의 단크론성 항체를 생산, 이용하여 감도가 높으면서도 신속히 측정할 수 있는 ELISA 기법을 처음으로 개발코져 실시하였다. 단크론성 항체는 종래의 면역방법에 의해 획득한 항혈청에 비해 약 10배의 결합율을 보였고 titer 역시 높았다. Dot-blot 분석 결과 단크론성 항체는 IgM이었다. 경합반응은 2시간으로 충분하였고, progesterone 표준용액을 이용한 표준 곡선은 0~1000pg/well에서 거의 직선적이었다. Progesterone의 단크론성 항체를 이용한 ELISA는 임상적으로는 물론 연구용으로도 신속한 항체의 기능 측정에는 물론 각종 번식 관련의 지표로 충분히 활용될 수 있을 것으로 판단된다.

  • PDF

ELISA에 의한 소의 혈청 progesterone 농도 측정 (Enzyme-linked immunosorbent assay(ELISA) for determination of progesterone concentration in bovine serum)

  • 강정부;손민수;이은석;조규완;김철호
    • 대한수의학회지
    • /
    • 제33권3호
    • /
    • pp.539-545
    • /
    • 1993
  • This study was carried out the determine the progesterone concentration for serum by enzyme-linked immunosorbent assay(ELISA) in bovine adult at estrous, pregnant, after patuation and male, female calves of 1 month old, respectively. The results obtained were summarized as follows ; 1. The assay has a sesitivity of $0.1ng/m{\ell}$. 2. Intra and inter-assay coefficient of variation were 4.5%, 6.1~9.4% when used for the determination of progesterone in samples of bovine serum. 3. The percentages of recovery for progesterone added were between 88.0 to 88.9%. 4. Progesterone concentration of adult bovine serum at estrus, pregnant and after 1 day of parturition were $0.37{\pm}0.16$, $7.1{\pm}1.0$, $0.13{\pm}0.02ng/m{\ell}$, respectively. 5. There was no differences in serum progesterone concentration of calves both male($0.16{\pm}0.03ng/m{\ell}$) and female($0.15{\pm}0.04ng/m{\ell}$) on 1 month old. From these results, progesterone determination by ELISA is very applicable to detect of early pregnancy diagnosis, factorial analysis of reproductive disorder, and also reproductive physiological functions such as veterinary therapeutic measures and monitoring of cyclicity.

  • PDF

혈청내의 Progesterone 측정을 위한 Chemiluminescence Immunoassay의 개발에 관한 연구 (Development of Chemiluminescence Immunoassay for Progesterone in Serum)

  • 이기순;서병희;이재현;김종배
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제17권1호
    • /
    • pp.87-91
    • /
    • 1990
  • Development of a solid-phase chemiluminescence immunoassay for the detection of progesterone in serum extract was described. The chemiluminescence immunoassay was establised utilizing anti-progesterone monoclonal antibody that coated on polystyrene tubes and progesterone-ABEI conjugate as tracer. The light yield generated from antibody bound conjugate was counted on clinilumat luminometer by oxidation with microperoxidase and peroxide. The chemiluminescence immunoassay was high specific and accurate and detects as little as 3.9ng/ml of progesterone. The intra-assay CV ranged from 6% to 11.5% and inter-assay CV ranged from 13.6% to 18.7%. This assay system was good correlated with conventional kit radioimmunoassay system (r=0.98).

  • PDF

단일클론항체를 이용한 Milk Progesterone Test(EIA) 측정법의 개발과 이에 의한 소의 발정 및 임신조기진단의 정확도 향상에 관한 연구 (Development of Milk Progesterone Test(EIA) using Monoclonal Antibody and It's Application to Estrus-and Early Pregnancy Detection in Dairy Cattle)

  • 김정우;홍승욱
    • 한국가축번식학회지
    • /
    • 제14권3호
    • /
    • pp.165-173
    • /
    • 1990
  • A simple and sensitive microplate enzyme immunoassay(ELISA) was developed for progesterone, based on progesterone monoclonal antibody as anti-progesterone, horseradish peroxise(HRP) as enzyme-label and tetramethylbenzidine(TMB) as substrate. The assay has a sensitivity of 5pg-120pg/well and intra- and inter assay coefficients of variation for progesterone standard curve(0.1ng-3.2ng/ml) were ranged 4.4-10.6% and 5.-12.6%, respectively. They assay is performed in less than two hours and provide reliable values to differentiate among samples from day 0(A.I.), day 14 and day 19. The discriminatory levels for early pregnancy diagnosis are [>10ng(day 19) & decreasing rate <1.5 : pregnancy] and [ 7ng & decreasing rate 1.5 : non-pregnancy]. The accuracy of the pregnancy diagnosis for cows classified as positive(pregnancy) and negative(non-pregnancy) were 96% and 100%, respectively.

  • PDF

혈청 Progesterone 측정을 위한 효소면역분석법 개발에 관한 연구 (Studies on Development of Microplate-EIA for the Determination of Serum Progesterone)

  • 김정우;이욱연
    • 한국가축번식학회지
    • /
    • 제17권4호
    • /
    • pp.347-356
    • /
    • 1994
  • A simpled and sensitive microplate enzyme immunoassay(EIA) was developed for the determination of progesterone concentration in serum, based on progesterone monoclonal antibody as anti-progesterone, horseradish peroxidase(HRP) as enzyme-label and tetramethylbenzidine(TMB) as substrate. The assay has a sensitivity of 5 pg-120pg/well and intra- and inter-assay coefficients of variation for progesterone standard curve (1.0ng~10.0ng/ml) were ranged 2.5~9.9% and 1.7.8.0%, respectively, determination coefficient of the regressio equation of our standard curve(R2=0.990$\pm$0.007) were high, and this is the same level as that of commercial kit(Hormonost Bio-Lab, Germany, R2=0.98~0.99). The progesterone concentration of serum determined by both kits (Work & Bio-Lab) were significantly correlated (r=0.95, P<0.01) although a little higher value were resulted in our kit than that of commercial kit. It generally is these results indicated that the microplate-EIA can be cused for the determination of progesterone in serum, as well as, for the determination of the early pregnancy diagnosis.

  • PDF

PLASMA AND MILK PROGESTERONE CONCENTRATIONS AND EARLY PREGNANCY IN ZEBU COWS

  • Alam, M.G.S.;Ghosh, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제7권1호
    • /
    • pp.131-136
    • /
    • 1994
  • In an effort to confirm true oestrus and to detect early pregnancy in Zebu cows (Bos indicus), sequential blood and milk samples were collected at the day of imsemination (Day 0) and days 14, 20 and 24 after insemination. Progesterone was determined in skimmed milk and plasma by solid phase radioimmunoassay (RIA). Of the cows thought to be in oestrus plasma, (n = 46) and milk (n = 58) samples demonstrated low progesterone concentrations ($0.99{\pm}0.11$ and $2.02{\pm}0.14nmol/l$) in 42 (91%) and 52 (90%) cases respectively. Thirty two (76%) and 30 (71%) cows were thought to be pregnant by plasma progesterone RIA ($20.23{\pm}1.03$ and $20.48{\pm}1.01nmol/l$) at days 20 and 24 respectively. At the same period, 40 (77%) and 37 (71%) cows were thought to be pregnant by milk progesterone RIA ($27.82{\pm}1.28$and $28.02{\pm}1.27nmol/l$). Assuming 100% accuracy for rectal examination of pregnancy diagnosis between days 60-65 postservice, the RIA was found to be 84% and 90% accurate for plasma and 84% and 92% accurate for milk at day 20 and 24, respectively. All cows thought to be non pregnant by progesterone measurement were correctly diagnosed. Progesterone assay at 24 days after oestrus may therefore be accurate for early diagnosis of pregnancy in Zebu cows.

흰쥐 자궁에서의 Cytosolic Progesterone 수용체 측정에 관한 연구 (Determination of Potimal Conditions for Cytosolic Progesterone Receptor Assay in Rat Uterus)

  • 박찬규;박기현;서경;이건수;윤미정;유경자
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제13권2호
    • /
    • pp.187-193
    • /
    • 1986
  • The purpose of this study was to establish optimal conditions for progesterone receptor assay using rat uterus, therby applying this system to understand action mechanism of progesterone in female reproductive organ and to evaluate physiological and pathological conditions in female reproduction. The results obtained were as follows 1. $^3H-R5020$ seemed to be more stable than 3H-progesterone as a ligand. 2. Optimal incubation time for ligand and receptor binding was 4-5 hrs at $4^{\circ}C$. 3. For the separation of bond and free ligand, optimal charcoal incubation time was 20 mins. 4. 2-3 mg cytosolic protein/ml was optimal for the binding of ligand. 5. Endogenous progesterone did not influence binding of ligand and receptor unless endogenous progesterone levels were extremely high as in case of pregnancy. 6. Dissociation rate for progesterone receptor was 1.22 nM. 7. $^3H-R5020$ did not bind to corticoid binding globulin (CBG), suggesting that addition of cortisol is saturate CBG was, not necessary as far as $^3H-R5020$ was used as a radioligand. It is, therefore, considered that this assay system established with these conditions might be used for the research as well as clinical routine purposes.

  • PDF

Establishment for Improving Productivity of Cattle by Fecal Steroid and Milk Urea Nitrogen Analysis - I. Development of Enzyme-linked Immunosorbent Assay for Progesterone and Milk Urea Nitrogen Analysis in Cattle

  • Chung-Boo Kang;Woo-Song Ha;Ji-In Kwon;Young-Sang Yu;Chul-Ho Kim;Soo-Dong Kwak
    • 대한의생명과학회지
    • /
    • 제8권4호
    • /
    • pp.235-244
    • /
    • 2002
  • This study was carried out to determine the blood and milk progesterone by enzyme-linked immunosorbent assay (ELISA), and milk urea nitrogen (MUN) in cows. MUN and protein concentration were determined using automated infared procedures. The optimum conditions of ELISA system was investigated including the first and second antibody titres, bound percent, and enzyme conjugate and also the factors on MUN and protein concentration by sampling procedures and addition of preservatives. Progesterone antibodies did not react to pregnenlone, testosterone, estrone, estradiol-l7$\beta$, aldosterone, cortisol, corticosterone and 11$\alpha$-dehydroxycortisone (DOC), but reacted with only progesterone. The intra and inter-assay coefficient of variation 4.5%, 6.1~9.4% when used of bovine serum. The morning, MUN concentration (17.6$\pm$2.8 mg/100 ml) in the 13 herds was similar to that of evening MUN concentration of the lactating cows from the same herd. A significant relationship between morning and evening milk samples of upper parameters was found r=0.93. Difference in MUN concentration with sampling procedures and using of preservatives were investigated.

  • PDF