• Title/Summary/Keyword: Profilometer

Search Result 144, Processing Time 0.026 seconds

Etch Characteristics of MgO Thin Films in Cl2/Ar, CH3OH/Ar, and CH4/Ar Plasmas

  • Lee, Il Hoon;Lee, Tea Young;Chung, Chee Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.387-387
    • /
    • 2013
  • Currently, the flash memory and the dynamic random access memory (DRAM) have been used in a variety of applications. However, the downsizing of devices and the increasing density of recording medias are now in progress. So there are many demands for development of new semiconductor memory for next generation. Magnetic random access memory (MRAM) is one of the prospective semiconductor memories with excellent features including non-volatility, fast access time, unlimited read/write endurance, low operating voltage, and high storage density. MRAM is composed of magnetic tunnel junction (MTJ) stack and complementary metal-oxide semiconductor (CMOS). The MTJ stack consists of various magnetic materials, metals, and a tunneling barrier layer. Recently, MgO thin films have attracted a great attention as the prominent candidates for a tunneling barrier layer in the MTJ stack instead of the conventional Al2O3 films, because it has low Gibbs energy, low dielectric constant and high tunneling magnetoresistance value. For the successful etching of high density MRAM, the etching characteristics of MgO thin films as a tunneling barrier layer should be developed. In this study, the etch characteristics of MgO thin films have been investigated in various gas mixes using an inductively coupled plasma reactive ion etching (ICPRIE). The Cl2/Ar, CH3OH/Ar, and CH4/Ar gas mix were employed to find an optimized etching gas for MgO thin film etching. TiN thin films were employed as a hard mask to increase the etch selectivity. The etch rates were obtained using surface profilometer and etch profiles were observed by using the field emission scanning electron microscopy (FESEM).

  • PDF

THE EFFECT OF ADHESIVE CURING TIMING ON THE DIRECTION OF POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN (상아질 접착제의 중합 시간 조절에 따른 복합레진의 중합 수축 방향의 변화)

  • 배지현;오명환;김창근;손호현;엄정문;조병훈;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.316-325
    • /
    • 2001
  • The purpose of this study was to evaluate the effect of adhesive curing timing on the direction of polymerization shrinkage of light-curing composite resin. In this study, the curing times of adhesive and composite resin were measured by differential scanning calorimeter(DSC). 28 extracted human molars were embedded in clear resin and box-type cavities were prepared. Based on DSC data, the experimental teeth were divided into 4 groups. Group 1: no bond; Group 2: late curing; Group 3: Intermediate curing; Group 4: Early curing. After treating with adhesive, the buccal cavities were filled with Z-100 hybrid composite resin and the lingual ones were filled with AEliteflo flowable composite resin. The depressions at the surface were measured by surface profilometer, then the specimens were embedded in clear resin and sectioned. Impressions were obtained and used to get epoxy resin replicas. The epoxy replicas were gold-coated and observed under SEM. Average Maximum Gap(AMG), Gap Proportion(GP), Average Marginal Index(AMI) were used to compare the shrinkage gap of each group. The results were statistically analyzed using the Kruskal-Wallis One Way ANOVA, Student-Newman-Keuls method. The results of this study were as follows. 1. Average Maximum Gap, Gap Proportion, Average Marginal Index and depression at the surface or Z-100 hybride composite resin were smaller than those of AEliteflo flowable composite resin(P<0.05). 2. When the bonding between composite resin and tooth structure was strong, the shrinkage gap was small, and depression at the surface was deep(P<0.05). 3. In the well-bonded group, light-curing composite resin shrank toward bonded cavity wall, not toward light source. The result suggested that the direction of polymerization shrinkage was affected by the quality of bonding in the dentin-resin interface. The strong was the bonding between composite resin and tooth structure, the smaller was the gap and the deeper was the depression at the surface. Then the flow to compensate the polymerization shrinkage proceeded from surface to bonded cavity wall.

  • PDF

A COMPARATIVE STUDY OF SURFACE CHARACTERISTICS OF DIRECT RELINE RESINS (의치상 직접 이장재의 표면 특성에 관한 비교 연구)

  • An Jong-Kwan;Lee Joon-Kyu;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.49-57
    • /
    • 2001
  • The use of autopolymerizing-cured resin and light-cured resin for direct introral relining of complete and partial dentures has been popular. The purpose of this investigation was to determine the surface characteristics of autopolymerizing-cured reline resins(Tokuso rebase, Mild rebaron, Meta base) and light-cured reline resin(Mild rebaron LC). Acrylic resin slab specimens(1.0cm in diameter at the bottom, and 0.3cm high) were made against glass according to the instructions of the manufacturer following normal procedures for each of direct reline resins and examined the surface characteristics by use of surface profilometer and the other specimens which were made intraorally for each of direct reline resins were examined by use of scanning electron microscopy. The results were as follows : 1. Each surface roughness(Rz) of hard relin resins was $0.14{\pm}0.04{\mu}m$ in Tokuso rebase, $0.37{\pm}0.11{\mu}m$ in Mild Rebaron, $0.79{\pm}0.44{\mu}m$ in Mild Rebaron LC, $6.36{\pm}3.40{\mu}m$ in Meta base. There were significant differences between the surface roughness of Meta base and those of other reline resins(p<0.05) 2. The generation of porosity was the most in Tokuso Rebase and followed by Meta base, Mild Rebaron and Mild Rebaron LC in the order respectively. 3. Light-cured reline resin(Mild rebaron LC) was denser in surface than any other autopolymerizing-cured reline resins. Tokuso rebase and Mild rebaron was denser than Meta base. Conclusively, light-cured reline resin(Mild rebaron LC) had less porosity and better surface density than any other autopolymerizing-cured reline resins.

  • PDF

AN IN-VITRO WEAR STUDY OF CEROMER AND HUMAN ENAMEL (Ceromer (Targis)에 의한 법랑질 마모에 관한 연구)

  • Kim, Jeong-Min;Lee, Sun-Hyung;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.4
    • /
    • pp.438-445
    • /
    • 2000
  • The ideal restorative material should mimic the properties of the tissues it replaces. Dental composite resins have been used widely as restorative materials due to its advantages such as excellent esthetics and ease of manipulation. But inadequate wear resistance has been a major factor limiting the use of composite restorative materials. Improved manufacturing techniques have allowed the development of hybrid composites, with a greater percentage volume filler loading, which have improved physical and mechanical properties. However they are lacking in the study of wear resistance. The purpose of this study was to evaluate the wear of human enamel against ceromer by the use of a pin-on-disk type wear testers. Discs of ceromer(Targis ; lvoclar Vivadent, Amherst. NY) and discs of type III gold alloy as a control were used f9r test specimens. Intact cusp of premolar and molar were used for enamel specimens. The wear of enamel was determined by weigh-ing the cusp before and after each test, and the weight converted to volumes by average densi-ty of enamel. Surface profilometer was used to quantify wear of the ceromer and gold specimens. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces The results were as follows; 1. Ceromer produced less enamel wear than gold(p<0.05) 2. The wear volume of ceromer was greater than that of gold(p<0.01) 3. The hardess of ceromer was lower than that of gold, but there was no correlation between the hardness and wear of the ceromer and gold. 4. SEM analysis revealed that there were many voids and microcracks in the wear tract of ceromer In gold group, many minute V-shaped grooves were examined.

  • PDF

Study on methodology for the assessment of internal and marginal adaptation on fixed dental prosthesis (고정성 보철물의 내면 및 변연적합도를 평가하는 방법에 대한 고찰)

  • Pyo, Se-Wook;Lee, Jun-Jae;Han, Jung-Suk;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.158-168
    • /
    • 2016
  • This article is to review various methods used to investigate internal and marginal adaptation of fixed dental prostheses, and to summarize a merit, worth, and limitation of each method, using some results of previous studies. The methods of measuring internal and marginal gap are divided into two categories in this study; in vivo and in vitro. In vivo methods are clinical evaluations, including exploration, radiography, and impression technique. In vitro methods are laboratory evaluations such as direct view, cross-sectioning, and silicone replica technique using microscope. Measuring by micro computed tomography (CT) or profilometer is also in vitro methods. In recent years, the development of scanning systems is able to analyze 3-dimensional internal and marginal space in detail. As measuring and analyzing technology become more advanced, the ability to thoroughly examine crown adaptation is becoming both simpler and more efficient.

Evaluation of antibacterial activity and osteoblast-like cell viability of TiN, ZrN and $(Ti_{1-x}Zr_x)N$ coating on titanium

  • Ji, Min-Kyung;Park, Sang-Won;Lee, Kwangmin;Kang, In-Chol;Yun, Kwi-Dug;Kim, Hyun-Seung;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.166-171
    • /
    • 2015
  • PURPOSE. The aim of this study was to evaluate antibacterial activity and osteoblast-like cell viability according to the ratio of titanium nitride and zirconium nitride coating on commercially pure titanium using an arc ion plating system. MATERIALS AND METHODS. Polished titanium surfaces were used as controls. Surface topography was observed by scanning electron microscopy, and surface roughness was measured using a two-dimensional contact stylus profilometer. Antibacterial activity was evaluated against Streptococcus mutans and Porphyromonas gingivalis with the colony-forming unit assay. Cell compatibility, mRNA expression, and morphology related to human osteoblast-like cells (MG-63) on the coated specimens were determined by the XTT assay and reverse transcriptase-polymerase chain reaction. RESULTS. The number of S. mutans colonies on the TiN, ZrN and $(Ti_{1-x}Zr_x)N$ coated surface decreased significantly compared to those on the non-coated titanium surface (P<0.05). CONCLUSION. The number of P. gingivalis colonies on all surfaces showed no significant differences. TiN, ZrN and $(Ti_{1-x}Zr_x)N$ coated titanium showed antibacterial activity against S. mutans related to initial biofilm formation but not P. gingivalis associated with advanced periimplantitis, and did not influence osteoblast-like cell viability.

Effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material

  • Ozarslan, Mehmet Mustafa;Buyukaplan, Ulviye Sbnem;Barutcigil, Cagtay;Arslan, Merve;Tuker, Nurullah;Barutcigil, Kubilay
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.16-20
    • /
    • 2016
  • PURPOSE. Polymer infiltrated ceramic network (PICN) materials, also called hybrid ceramics, are new materials in dental market. The manufacturer of the PICN material VITA Enamic suggests 3 different finishing procedures for this new material. In the present study, surface roughness and color differences caused from different finishing procedures of VITA Enamic were investigated. MATERIALS AND METHODS. 120 specimens were prepared in dimensions $2{\times}10{\times}12mm$ from VITA Enamic hybrid ceramic blocks with 'high translucency' and 'translucency 2M2' shades. The specimens were divided into 8 groups. For each group, different finishing procedures suggested by the manufacturer were performed. Surface roughness values were determined by a tactile portable profilometer. Color changes were evaluated using a clinical spectrophotometer. The data were analyzed using one-way ANOVA and Tukey's post-hoc comparison. The significance level was set at ${\alpha}=0.05$. RESULTS. The roughest surfaces were observed in Glaze Groups. Their surface roughness values were similar to that of the control group. Clinical Kit and Technical Kit groups did not show a statistically significant difference regarding surface roughness (P>.05). The largest color difference regarding ${\Delta}E_{00}$ was observed in Clinical Kit finishing groups. There were also statistically significant color changes between the groups (P<.05). However, all the groups showed clinically acceptable color change (${\Delta}E_{00}$<2.25) except Clinical Kit Groups (${\Delta}E_{00}$>2.25). CONCLUSION. Within the limitations of the present study, it may be suggested that finishing the VITA Enamic restorations by Technical Kit instead of Glaze and Clinical Kit gives better clinical performance in regard to surface roughness and shade matching.

SURFACE ROUGHNESS OF UNIVERSAL COMPOSITES AFTER POLISHING PROCEDURES (전.구치 겸용 혼합형 복합레진의 두 가지 연마법에 따른 표면조도)

  • Lee, Jae-Yong;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.5
    • /
    • pp.369-377
    • /
    • 2003
  • The aim of this study was to evaluate the effect of two polishing methods and chemical conditioning on the surface of hybrid composites. Ninety cylindrical specimens (diameter:8mm, depth:2mm) were made with three hybrid composites-Filtek Z250, Tetric Ceram. DenFil. Specimens for each composite were randomly divided into three treatment subgroups $^{\circled1}$ Mylar strip (no treatment). $^{\circled2}$ Sof-Lex XT system, $^{\circled3}$ PoGo system. Average surface roughness(Ra) was taken using a surface profilometer at the time of setting and after immersion into 0.02N lactic acid for 1 week and 1 month. Representative specimens were examined by scanning electron microscopy. The data were analyzed using ANOVA and Scheffe's tests at 0.05% significance level. The results were as follows:1. Mylar strip resulted in smoother surface than PoGo and Sof-Lex system (p<0.001). Sof-Lex system gave the worst results. 2. Tetric Ceram was smoother than DenFil and Z250 when cured under only mylar strip. However, it was significantly rougher than other materials when polished with PoGo system. 3. All materials showed rough surface after storage in 0.02N lactic acid, except groups polished with a PoGo system. The PoGo system gave a superior polish than Sof-Lex system for the three composites. However. the correlation to clinical practice may be limited, since there are several processes. such as abrasive, fatigue, and corrosive mechanisms. Thus. further studies are needed for polishing technique under in vivo conditions.

Effects of different surface finishing protocols for zirconia on surface roughness and bacterial biofilm formation

  • Lee, Du-Hyeong;Mai, Hang-Nga;Thant, Phyu Pwint;Hong, Su-Hyung;Kim, Jaewon;Jeong, Seung-Mi;Lee, Keun-Woo
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.1
    • /
    • pp.41-47
    • /
    • 2019
  • PURPOSE. Surface finishing of a zirconia restoration is essential after clinical adjustment. Herein, we investigated the effects of a surface finishing protocol for monolithic zirconia on final roughness and bacterial adherence. MATERIALS AND METHODS. Forty-eight disk-shaped monolithic zirconia specimens were fabricated and divided into four groups (n = 12) based on initial surface treatment, finishing, and polishing protocols: diamond bur+polishing bur (DP group), diamond bur+stone grinding bur+polishing bur (DSP group), no diamond bur+polishing bur (NP group), and no diamond bur+stone grinding bur+polishing bur (NSP group). Initial and final surface roughness was measured with a profilometer, and shown using scanning electron microscope. Bacterial adhesion was evaluated by quantifying Streptococcus mutans in the biofilm. Kruskal-Wallis and Mann-Whitney U tests were used to compare results among groups, and two-way analysis of variance was used to evaluate the effects of grinding burs on final roughness (${\alpha}=.05$). RESULTS. The DP group had the highest final Ra value, followed by the DSP, NP, and NSP groups. Use of the stone grinding bur as a coarse-finishing step significantly decreased final Ra values when a diamond bur was used (P<.001). Omission of the stone grinding bur increased biofilm formation on specimen surfaces. Combining a stone grinding bur with silicone polishing burs produced the smallest final biofilm values, regardless of the use of a diamond bur in initial surface treatment. CONCLUSION. Coarse finishing of monolithic zirconia with a stone grinding bur significantly decreased final Ra values and bacterial biofilm formation when surfaces had been roughened by a diamond bur.

Effects of different surface treatments on the shear bond strength of veneering ceramic materials to zirconia

  • Abdullah, Adil Othman;Hui, Yu;Sun, Xudong;Pollington, Sarah;Muhammed, Fenik Kaml;Liu, Yi
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.1
    • /
    • pp.65-74
    • /
    • 2019
  • PURPOSE. To evaluate and compare the effect of different materials and techniques on the shear bond strength of veneering ceramic materials to zirconia. MATERIALS AND METHODS. 136 sintered zirconia cubes were prepared and randomly divided into four study groups according to corresponding methods of surface treatment and materials: GLN (grinding followed by laser scanning using Noritake Cerabien ZR), SLN (sandblasting followed by laser scanning using Noritake Cerabien ZR), GLV (grinding followed by laser scanning using VITA VM 9), and SLV (sandblasting followed by laser scanning using VITA VM 9). Spraying technique was performed to coat the core. Profilometer, SEM, XRD, EDS, universal testing machine, and stereomicroscope were used to record surface roughness Ra, surface morphology, phase transformation, elemental compositions, shear bond strength SBS values, and failure types, respectively. Specimens were investigated in unaged (not immersed in artificial saliva) and aged (stored in artificial saliva for a month) conditions to evaluate SBS values. RESULTS. Grinding and GLN as first and second surface treatments provided satisfactory Ra values in both conditions ($1.05{\pm}0.24{\mu}m$, $1.30{\pm}0.21{\mu}m$) compared to sandblasting and other groups (P<.05). The group GLN showed the highest SBS values in both conditions ($30.97{\pm}3.12MPa$, $29.09{\pm}4.17MPa$), while group SLV recorded the lowest ($23.96{\pm}3.60MPa$, $22.95{\pm}3.68Mpa$) (P<.05). Sandblasting showed phase transformation from t-m. Mixed failure type was the commonest among all groups. CONCLUSION. GLN showed to be a reliable method which provided satisfactory bond strength between the veneer ceramic and zirconia. This method might preserve the integrity of fixed dental crowns.