• Title/Summary/Keyword: Profile measurements

Search Result 541, Processing Time 0.033 seconds

Verification of Dose Distribution for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 방사선 수술의 선량분포의 실험적 확인)

  • Park Kyung Ran;Kim Kye Jun;Chu Sung Sil;Lee Jong Young;Joh Chul Woo;Lee Chang Geol;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.421-430
    • /
    • 1993
  • The calculation of dose distribution in multiple arc stereotactic radiotherapy is a three-dimensional problem and, therefore, the three-dimensional dose calculation algorithm is important and the algorithm's accuracy and reliability should be confirmed experimentally. The aim of this study is to verify the dose distribution of stereotactic radiosurgery experimentally and to investigate the effect of the beam quality, the number of arcs of radiation, and the tertiary collimation on the resulting dose distribution. Film dosimetry with phantom measurements was done to get the three-dimensional orthogonal isodose distribution. All experiments were carried out with a 6 MV X-ray, except for the study of the effects of beam energy on dose distribution, which was done for X-ray energies of 6 and 15 MV. The irradiation technique was from 4 to 11 arcs at intervals of from 15 to 45 degrees between each arc with various field sizes with additional circular collimator. The dose distributions of square field with linear accelerator collimator compared with the dose distributions obtained using circular field with tertiary collimator. The parameters used for comparing the results were the shape of the isodose curve, dose fall-offs fom $90\%$ to $50\%$ and from $90\%\;to\;20\%$ isodose line for the steepest and shallowest profile, and $A=\frac{90\%\;isodose\;area}{50\%\;isodose\;area-90\%\;isodose\;area}$(modified from Chierego). This ratio may be considered as being proportional to the sparing of normal tissue around the target volume. The effect of beam energy in 6 and 15 MV X-ray indicated that the shapes of isodose curves were the same. The value of ratio A and the steepest and shallowest dose fall-offs for 6 MV X-ray was minimally better than that for 15 MV X-ray. These data illustrated that an increase in the dimensions of the field from 10 to 28 mm in diameter did not significantly change the isodose distribution. There was no significant difference in dose gradient and the shape of isodose curve regardless of the number of arcs for field sizes of 10, 21, and 32 mm in diameter. The shape of isodose curves was more circular in circular field and square in square field. And the dose gradient for the circular field was slightly better than that for the square field.

  • PDF

STUDY ON LATERAL CEPHALOGRAM OF CHILDREN WITH NORMAL OCCLUSION IN THE PRIMARY DENTITION (유치열기 정상교합아동의 측모두부방사선 계측연구)

  • Kim, Ji-Youn;Kwon, Jang-Hyuk;Kim, Kyung-Ho;Park, Ki-Tae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.649-656
    • /
    • 2005
  • The present study was designed to formulate cephalometric norms of normal occlusion for usage in orthodontic diagnosis of malocclusion in Korean children. Thirty two children, aged 4 to 6, with normal occlusion were chosen for this study, Sagittal and vertical relations were analyzed using lateral cephalogram and clinical photos and the measurements were compared with those of adults. On skeletal sagittal analysis, the mean values of the SNA and SNB angles were $83^{\circ}\;and\;78.72^{\circ}$. It showed that the mandible was retrognathic and retropositioned in comparison to those of adults. On skeletal vertical analysis, the mean values of the genial angle was $127^{\circ}$. This showed high angle pattern in children and reduction of genial angle due to counterclockwise rotation of the mandible is expected with growth. On soft tissue analysis, children showed convex pronto, obtuse nasolabial angle. On dental analysis, the mean values of the U1 to SN and IMPA were $91.04^{\circ}\;and\;86.57^{\circ}$. This showed retroclined upper and lower deciduous teeth in comparison to adults. For skeletal values, the liner values were generally greater in males than females.

  • PDF

A Performance Analysis of an Adaptive Sector Cell System using the Measured Urban Wireless Channel Data (도심 무선채널의 실측데이터를 이용한 적응 섹터 셀 시스템의 성능분석)

  • Ko, Hak-Lim;Park, Byeong-Hoon;Lee, Jong-Heon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.1
    • /
    • pp.24-30
    • /
    • 2008
  • In this paper we analyze the performance of an adaptive sector cell system, which is adopted to maintain the traffic balance between sectors and to utilize the cell resources effectively, using the data collected from real channel environments. In the data measurements, we transmitted the QPSK modulated signal with carrier frequency of 1.95GHz and received the signals using the 8x4 array antenna equipped on the top of buildings in the urban area. We analyzed the angular distribution and the delay spread of a user signal and analyzed angular distribution of mobile users in a cell using the collected data. Also, we propose the vector channel modeling using the estimated pdf(probability distribution function) of the analyzing results. Through the proposed channel modeling the improvement of the call blocking rate was analyzed when using the adaptive sector cell system, and computer simulations show that the call blocking rate of the adaptive sector cell system was much lower than that of the fixed sector cell system. Additionally, it shows that the call blocking rate increases severely in the fixed sector cell system while the difference of the call blocking rate was smaller in the adaptive sector cell system, as the user density of the spatial distribution increases.

  • PDF

CHANGE OF LATERAL SOFT TISSUE PROFILE AFTER SURGICAL CORRECTION OF MANDIBULAR PROGNATHISM (하악전돌증의 악교정수술후 연조직 변화에 관한 연구)

  • Lee, Sang-Chull;Kim, Yeo-Gab;Ryu, Dong-Mok;Lee, Wan-Kee
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.14 no.3
    • /
    • pp.217-227
    • /
    • 1992
  • The purpose of this paper is to investigate changes in soft tissue in 22 patients treated by vertical ramus osteotomy and sagittal split ramus osteotomy for the correction of mandibular prognathism. 22 individuals, 12 males and 10 females, were selected from the patients with mandibular prognathism at the Department of Oral and Maxillofacial Surgery, Colledge of Dentistry, Kyung Hee University. Patient were analyzed with cephalogram taken 1 week before and at least 6 weeks after surgery under the same condition. Measurements were made constructed hard tissue and sop tissue points located on each before-and-after film tracing. Comparision were made of these figures to estimate the amount that the soft tissue followed the hard tissue structures in each surgical procedure : ratio of sop and hard tissue changes were formulated. The results were as follows. 1. The horizontal changes of Pogs and Bs as a ratio of the horizontal changes of Pog and B point were 1.02 and 1.16 respectively. 2. One millimeter of posterior changes at Pog resulted in 0.86mm of posterior change at Li and 0.09mm of posterior change at Ls. The greatest amount of sop tissue change occurred at Pogs, with substantially less posterior displacement at Bs, even less at Li and at least at Ls. 3. The ratio of LI to Li was 1:0.81 and the ratio of LI to Ls was not significant.(1 : 0.17) 4. The ULA(Cm-Sn-Ls) and the relative lower lip projection (LLP) was incnease4 but the relative upper lip projection (ULP) was slightly decreased 5. The angular change of the upper lip inclined angle (Ls-Sn/ANS-PNS) and lower lip inclined angle(Li-Pogs/Me-Go) expressed as a ratio of the posterior change of Pog were 0.57 and 0.20 respectively. 6. The ratio of the lower anterior facial height change of the soft tissue(Sn-Mes) to the hard tissue(ANS-Gn) were 0.78 and and the ratio of vertical height changes of the hard tissue and sop tissue to the posterior change of the Pog were 0.18 and 0.19 respectively. 7. The sop tissue angular change of facial convexity(G-Sn-Pogs) expressed as a ratio of the angular change of the hard tissue angle of facial convexity(N-A-Pog) was 1.24.

  • PDF

Development of Tomographic SASW Method to Evaluate Two-Dimensional Variability of Shear Stiffness (지반 및 구조물의 이차원적 전단강성 평가를 위한 토모그래픽 SASW 기법의 개발)

  • 조성호
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.2
    • /
    • pp.29-42
    • /
    • 1999
  • The SASW (Spectral-Analysis-of-Surface-Waves) method, which evaluates the stiffness structure of the subsurface and structures nonintrusively and nondestructively, has been successfully used in the civil engineering applications. However, the SASW method assumes that the subsurface or structures consist of horizontal multi-layers, so that the method has some difficulty in continuously evaluating the integrity of a tunnel lining and a pavement system. This difficulty prevents the SASW method from being used to generate a tomographic image of stiffness for the subsurface or structures. Recently, the GPR technique which has the advantage of continuously evaluating integrity of the subsurface and structures has been popular. This advantage of GPR technique initiated the efforts to make the SASW method, which is superior to GPR and other nondestructive testing methods due to its capability of evaluating stiffness and modulus, be able to do continuous evaluation of stiffness structure, and the efforts finally lead to the development of \ulcornerTomographic SASW Technique.\ulcorner Tomographic SASW technique is a variation of the SASW method, and can generate a tomographic image of stiffness structure along the measurement line. The tomographic SASW technique was applied to the investigation of lateral variability of a sand box placed by the raining method for the purpose of verifying its effectiveness. Tomographic SASW measurements on the sand box revealed that the investigated sand box has different shear stiffness along the measurement line, which gave a clue of how to make a better raining device.

  • PDF

A COMPARATIVE STUDY ON THE CANAL CONFIGURATION AFTER SHAPING BY PROFILE, PROTAPERTM AND K-FLEXOFILE IN SIMULATED CANALS WITH DIFFERENT ANGLES OF CURVATURE (ProFile, ProTaperTM K-Flexofile 근관 성형시 근관의 만곡도에 따른 근관 형태 변화 비교연구)

  • Lee, Bo-Kum;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.294-302
    • /
    • 2005
  • The purpose of this study was to evaluate the canal configuration after shaping by ProFile. ProTaper and K-Flexofile in simulated resin canals with different angles of curvature. Three types of instruments were used: ProFile. ProTaper. K-Flexofile. Simulated root canals. which were made of epoxy resin. were prepared by ProFile. ProTaper with rotary instrument using a crown-down pressureless technique. and hand instrumentation was performed by K-Flexofile using a step-back technique. All simulated. canals were prepared up to size 25 file at end-point of preparation. Pre and post instrumentation images were recorded with Scanner. Assessment of canal shape was completed with Image Analysis program. Measurements were made at 1. 2. 3. 4. 5. 6. 7. 8. 9 and 10mm from the apex. At each level. outer canal width. inner canal width. total canal width. and amount of transportation from original axis were recorded. Instrument deformation and fracture were recorded. Data were analyzed by means of one-way ANOVA analysis of variance and the Sheffe's test. The result was that ProFile and ProTaper maintain original canal shape regardless of the increase of angle of curvature than K-Flexofile. ProFile show significantly less canal transportation and maintained original canal shape better than ProTaper.

Design and Application of Acrylic Electron Wedge to Improve Dose Inhomogeneities at the Junction of Electron Fields (전자선 조사야 결합부분의 선량분포 개선을 위한 Acrylic Electron Wedge의 제작 및 사용)

  • Kim Young Bum;Kwon Young Ho;Whang Woong Ku;Kim You Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.60-68
    • /
    • 1998
  • Treatment of a large diseased area with electron often requires the use of two or more adjoining fields. In such cases, not only electron beam divergence and lateral scattering but also fields overlapping and separation may lead to significant dose inhomogeneities(${\pm}20\%$) at the field junction area. In this study, we made Acrylic Electron Wedges to improve dose homogeneities(${\pm}5\%$) in these junction areas and considered application it to clinical practices. All measurements were made using 6, 9, 12, 16, 20MeV Electron beams from a linear accelerator for a $10{\times}10cm$ field at 100cm SSD. Adding a 1 mm sheet of acryl gradually from 1 mm to 15 mm, We acquired central axis depth dose beam profile and isodose curves in water phantom. As a result, for all energies, the practical range was reduced by approximately the same distance as the thickness of the acryl insert, e.g. a 1 mm thick acryl insert reduce the practical range by approximately 1 mm. For every mm thickness of acryl inserted, the beam energy was reduced by approximately 0.2MeV. These effects were almost independent of beam energy and field size. The use of Acrylic Electron Wedges produced a small increase $(less\;than\;3\%)\;in\;the\;surface\;dose\;and\;a\;small\;Increase(less\;than\;1\%)$ in X-ray contamination. For acryl inserts, thickness of 3 mm or greater, the penumbra width increased nearly linear for all energies and isodose curves near the beam edge were nearly parallel with the incident beam direction, and penumbra width was $35\;mm{\sim}40\;mm$. We decide heel thickness and angle of the wedge at this point. These data provide the information necessary to design Acrylic Electron Wedge which can be use to improve dose uniformity at electron field junctions and it will be effectively applicated in clinical practices.

  • PDF

$TiO_2$ Thin Film Patterning on Modified Silicon Surfaces by MOCVD and Microcontact Printing Method

  • 강병창;이종현;정덕영;이순보;부진효
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.77-77
    • /
    • 2000
  • Titanium oxide (TiO2) thin films have valuable properties such as a high refractive index, excellent transmittance in the visible and near-IR frequency, and high chemical stability. Therefore it is extensively used in anti-reflection coating, sensor, and photocatalysis as electrical and optical applications. Specially, TiO2 have a high dielectric constant of 180 along the c axis and 90 along the a axis, so it is highlighted in fabricating dielectric capacitors in micro electronic devices. A variety of methods have been used to produce patterned self-assembled monolayers (SAMs), including microcontact printing ($\mu$CP), UV-photolithotgraphy, e-beam lithography, scanned-probe based micro-machining, and atom-lithography. Above all, thin film fabrication on $\mu$CP modified surface is a potentially low-cost, high-throughput method, because it does not require expensive photolithographic equipment, and it produce micrometer scale patterns in thin film materials. The patterned SAMs were used as thin resists, to transfer patterns onto thin films either by chemical etching or by selective deposition. In this study, we deposited TiO2 thin films on Si (1000 substrateds using titanium (IV) isopropoxide ([Ti(O(C3H7)4)] ; TIP as a single molecular precursor at deposition temperature in the range of 300-$700^{\circ}C$ without any carrier and bubbler gas. Crack-free, highly oriented TiO2 polycrystalline thin films with anatase phase and stoichimetric ratio of Ti and O were successfully deposited on Si(100) at temperature as low as 50$0^{\circ}C$. XRD and TED data showed that below 50$0^{\circ}C$, the TiO2 thin films were dominantly grown on Si(100) surfaces in the [211] direction, whereas with increasing the deposition temperature to $700^{\circ}C$, the main films growth direction was changed to be [200]. Two distinct growth behaviors were observed from the Arhenius plots. In addition to deposition of THe TiO2 thin films on Si(100) substrates, patterning of TiO2 thin films was also performed at grown temperature in the range of 300-50$0^{\circ}C$ by MOCVD onto the Si(100) substrates of which surface was modified by organic thin film template. The organic thin film of SAm is obtained by the $\mu$CP method. Alpha-step profile and optical microscope images showed that the boundaries between SAMs areas and selectively deposited TiO2 thin film areas are very definite and sharp. Capacitance - Voltage measurements made on TiO2 films gave a dielectric constant of 29, suggesting a possibility of electronic material applications.

  • PDF

A Study on the Improvement of Wavefront Sensing Accuracy for Shack-Hartmann Sensors (Shack-Hartmann 센서를 이용한 파면측정의 정확도 향상에 관한 연구)

  • Roh, Kyung-Wan;Uhm, Tae-Kyoung;Kim, Ji-Yeon;Park, Sang-Hoon;Youn, Sung-Kie;Lee, Jun-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.383-390
    • /
    • 2006
  • The SharkHartmann wavefront sensors are the most popular devices to measure wavefront in the field of adaptive optics. The Shack-Hartmann sensors measure the centroids of spot irradiance distribution formed by each corresponding micro-lens. The centroids are linearly proportional to the local mean slopes of the wavefront defined within the corresponding sub-aperture. The wavefront is then reconstructed from the evaluated local mean slopes. The uncertainty of the Shack-Hartmann sensor is caused by various factors including the detector noise, the limited size of the detector, the magnitude and profile of spot irradiance distribution, etc. This paper investigates the noise propagation in two major centroid evaluation algorithms through computer simulation; 1st order moments of the irradiance algorithms i.e. center of gravity algorithm, and correlation algorithm. First, the center of gravity algorithm is shown to have relatively large dependence on the magnitudes of noises and the shape & size of irradiance sidelobes, whose effects are also shown to be minimized by optimal thresholding. Second, the correlation algorithm is shown to be robust over those effects, while its measurement accuracy is vulnerable to the size variation of the reference spot. The investigation is finally confirmed by experimental measurements of defocus wavefront aberrations using a Shack-Hartmann sensor using those two algorithms.

The Correlation Between Smartphone Addiction and Sensory Processing Feature Depending on Gender in College Students (작업치료전공 대학생의 성별에 따른 스마트폰 중독과 감각처리와의 관련성)

  • Hong, Eunkyoung;Lee, Hyerim
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.16 no.3
    • /
    • pp.1-10
    • /
    • 2018
  • Objective : The purpose of this study was to investigate smartphone addition and sensory processing character depend on gender for occupational therapy (OT) students, and to identify the correlation between smartphone addiction and sensory processing feature. Methods : Participants of this study were 168 (70 male/90 female) students majoring occupational therapy. Measurements in this study were a questionnaire about general information of subject, smartphone addiction scale, and adult/adolescent sensory profile. Data collection period was from November 2017 to March 2018. Methods for the data analysis included descriptive statistics, independent t-test and Pearson correlation of SPSS 22.0. Results : In term of the purpose of using smartphone, majority response was communication and gaming ranked in next. There were difference between male and female in the total smartphone addition, cyberspace-oriented relationship, withdrawal and tolerance. The result showed that all sensory processing are related with total smartphone addition (r = .236 ~ .603) for man. And for women, total smartphone addition is little related with the taste/smell processing (r= .290), visual processing (r= .324), touch processing (r= .214), low registration (r= .214), sensory sensitivity (r= .243), and sensory avoiding (r= .217). Conclusion : This study found that there is difference between male and female in terms of relation between smartphone addition and sensory processing feature according for occupational therapy students.